Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Cardiovasc Surg (Torino) ; 63(6): 742-748, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36168952

RESUMEN

BACKGROUND: Ascending aorta manipulation during on-pump coronary artery bypass grafting (CABG) surgery can release embolic matter and may cause stroke. Strategies for lowering the stroke rate associated with coronary artery bypass grafting surgery include off-pump surgery without cardiopulmonary bypass and pump-assisted surgery with minimal aortic manipulation (i.e., without aortic cross-clamping). We examined whether one approach is superior to the other in reducing stroke and perioperative mortality rates. METHODS: We reviewed consecutive elective, urgent, and emergency off-pump/no-bypass and pump-assisted/no-clamp coronary artery bypass grafting procedures performed by a single surgeon at our institution from June 2011 through October 2017. RESULTS: Of 570 patients analyzed, 395 (69.3%) underwent off-pump/no-bypass surgery, 43 (7.5%) underwent pump-assisted/no-clamp surgery, and 132 (23.2%) transitioned mid-procedure from off-pump/no-bypass to pump-assisted/no-clamp surgery. Patients who were >70 years old, were female, or had diabetes, cardiomegaly, or a history of myocardial infarction or congestive heart failure were more likely to undergo pump-assisted/no-clamp surgery or the combined technique. None of the pump-assisted/no-clamp patients had a stroke, versus 0.3% of the off-pump/no-bypass patients and 0.8% of the combination patients. Stroke and in-hospital mortality rates did not differ by technique. CONCLUSIONS: A hybrid strategy incorporating off-pump, pump-assisted, and combined off-pump/pump-assisted techniques achieved very low stroke rates in patients undergoing coronary revascularization. Perioperative mortality was similar for all three techniques. Avoiding aortic clamping may be crucial for decreasing CABG-related stroke rates. Off-pump/no-bypass surgery had no significant advantage over the pump-assisted/no-clamp or combined techniques in reducing the stroke rate after coronary artery bypass grafting surgery.


Asunto(s)
Complicaciones Posoperatorias , Accidente Cerebrovascular , Humanos , Femenino , Anciano , Masculino , Complicaciones Posoperatorias/etiología , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Puente Cardiopulmonar/efectos adversos , Accidente Cerebrovascular/etiología , Aorta , Resultado del Tratamiento
2.
Ann Thorac Surg ; 114(5): 1944-1950, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35921854

RESUMEN

PURPOSE: We examined the hemodynamic effects of a new, implantable, direct cardiac assist device in an ovine heart failure model. DESCRIPTION: The device, which encompasses both left and right ventricles, is inserted through the pericardial apex and self-expands to encompass the heart without suturing. The intact pericardium anchors the device in place. The device has 2 concentric chamber layers: an internal chamber layer filled with fluid to conform to the heart and an external chamber layer filled with air that provides external compression and negative pressure to aid relaxation. EVALUATION: The device was implanted in 7 sheep with heart failure induced by microsphere embolization. Cardiac performance was assessed for 6 to 8 hours. The cardiac assist device provided cardiac systolic and diastolic assistance, as shown by pressure tracings of the left ventricle and aorta, pulmonary artery flow, and +dP/dt. Central venous pressure decreased during cardiac assistance. No anatomic damage was noted postmortem. CONCLUSIONS: Systolic and diastolic cardiac assistance can be achieved with this device that compresses and relaxes in synchrony with the native cardiac cycle.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Animales , Ovinos , Diástole , Ventrículos Cardíacos , Hemodinámica , Insuficiencia Cardíaca/cirugía , Presión Venosa Central
3.
Interact Cardiovasc Thorac Surg ; 34(3): 470-477, 2022 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-34966937

RESUMEN

OBJECTIVES: Dialysis is considered a contraindication to continuous-flow left ventricular assist device (CF-LVAD) implantation. We evaluated clinical outcomes and survival in carefully selected, low-risk patients with renal failure who required dialysis before CF-LVAD implantation. METHODS: We extracted medical record data of patients who underwent CF-LVAD placement at our centre between 1 January 2006 and 31 August 2017, with 2 clinical scenarios: those who required long-term (>14 days) dialysis and those who required short-term (≤14 days) dialysis immediately before implantation. Demographic, clinical and intraoperative characteristics and survival outcomes were assessed. RESULTS: Of 621 patients who underwent CF-LVAD implantation during the study period, 31 underwent dialysis beforehand. Of these, 17 required long-term dialysis (13 haemodialysis, 4 peritoneal dialysis), and 14 underwent short-term haemodialysis. Compared with the long-term dialysis patients, the short-term dialysis patients were more likely to be Interagency Registry for Mechanically Assisted Circulatory Support profile 1-2 (92.9% vs 70.6%; P < 0.001), to have needed preoperative mechanical circulatory support (78.6% vs 70.6%; P < 0.01) and to have higher in-hospital mortality (85.7% vs 29.4%; P = 0.01). Patients stable on long-term dialysis had acceptable overall survival and markedly better 6-month and 1-year survival than those with short-term dialysis before implantation (64.7% vs 14.3% and 58.8% vs 7.1%, respectively; P < 0.001). CONCLUSIONS: Carefully selected patients who are stable on long-term dialysis have acceptable survival rates after CF-LVAD implantation. Patients with acute renal failure had much poorer outcomes than those with chronic end-stage renal disease.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Ann Thorac Surg ; 110(4): 1316-1323, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32194033

RESUMEN

BACKGROUND: The long-term results of heterotopic cardiac transplantation have not been well defined. Patient survival rates and the fate of the native heart remain unclear. METHODS: This study is a retrospective review of all 46 heterotopic cardiac transplantations performed at a single institution, the Texas Heart Institute in Houston, Texas, between 1982 and 2017. Four patients who underwent heterotopic transplantation as an emergency procedure for cardiogenic shock were excluded. Three of the procedures were repeat transplantations in patients who had previously undergone heterotopic transplantation; the 3 repeat transplantations were excluded, but the original procedures were not. Follow-up was 100% complete for mortality and 77% complete (30 of 39 patients) for assessment of preoperative indication for surgery and postoperative cardiac function. RESULTS: For the 39 patients, the 1-year, 5-year, and 10-year survival rates were 69%, 36%, and 21%, respectively. One patient remains alive 25 years after the transplantation procedure. The most frequent indication for heterotopic transplantation was pulmonary vascular resistance greater than 4 Wood units (n = 11), followed by weight greater than 112.5 kg (n = 7). In most patients, native heart left ventricular ejection fraction stabilized over time to between 10% and 30%. Sinus rhythm was preserved in 87% (26 of 30) of native hearts at long-term follow-up. CONCLUSIONS: Heterotopic cardiac transplantation is an acceptable procedure that should be considered for obese patients (especially those heavier than 112.5 kg) and patients with elevated pulmonary vascular resistance (especially those with pulmonary vascular resistance >4.0 Wood units). After heterotopic transplantation, native cardiac function appears to stabilize, and there is potential for native heart recovery.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Trasplante Heterotópico , Adulto , Índice de Masa Corporal , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Retrospectivos , Volumen Sistólico , Tasa de Supervivencia , Resultado del Tratamiento , Resistencia Vascular
5.
J Thorac Cardiovasc Surg ; 151(1): 192-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26344685

RESUMEN

OBJECTIVE: Ventricular reconditioning and device weaning in select patients with continuous-flow left ventricular assist devices (CF LVADs) has been shown to be feasible. However, little is known regarding the outcomes associated with different surgical methods of device removal. We examined the effect of surgical explantation approach on early and late outcomes. METHODS: We retrospectively reviewed data from all patients who underwent successful ventricular weaning and CF LVAD explantation at our center. Patients were stratified by surgical approach. Descriptive univariate statistics, multivariate regression, and survival analyses were performed. Patients were censored by transplant, device reimplantation, or end of follow-up. RESULTS: Twenty-seven patients were identified who underwent successful removal of a CF LVAD (25 HeartMate II, 2 HeartWare) after 532 ± 424 days of support (range, 42-1937 days). Four approaches were used that vary primarily in the degree of retained pump material: complete pump removal with plug ventriculotomy closure (n = 13; 48%), pump housing explant with ligation of the inflow and outflow grafts (n = 7; 26%), ligation of the outflow graft and driveline transection (n = 5; 19%), and driveline transection alone (n = 2; 7%). Mean overall postexplant survival was 1286 ± 947 days (range, 143-3072 days). Overall time-to-event and survival analyses showed no significant association between surgical approach and postoperative length of stay (P = .7), stroke (P = .12), reoperation (P = .4), or survival (P = .12). CONCLUSIONS: For patients who receive device therapy, pump deactivation and removal represents a favorable outcome. All methods are feasible and produce similar early and late survival and clinical outcomes.


Asunto(s)
Remoción de Dispositivos/métodos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Función Ventricular Izquierda , Adulto , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/mortalidad , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Persona de Mediana Edad , Análisis Multivariante , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Recuperación de la Función , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Texas , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
7.
Eur J Cardiothorac Surg ; 44(3): 573-4, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23456013

RESUMEN

The HeartMate II is a continuous-flow left ventricular assist device that can be explanted from patients after cardiac recovery. We implanted a HeartMate II in a 21-year-old man who had idiopathic cardiomyopathy. A year later, he developed thyrotoxicosis, presumably secondary to amiodarone administered for ventricular fibrillation. Four months after the diagnosis of thyrotoxicosis, thyroid hormone levels had returned to normal, and native cardiac function had improved remarkably. After a support period of 24 months, the HeartMate II was explanted. Six years later, the patient continues to be in New York Heart Association functional Class I. Amiodarone-induced thyrotoxicosis may have contributed to myocardial recovery.


Asunto(s)
Cardiomiopatías/tratamiento farmacológico , Cardiomiopatías/cirugía , Corazón Auxiliar , Tirotoxicosis/fisiopatología , Amiodarona/efectos adversos , Amiodarona/uso terapéutico , Humanos , Masculino , Tirotoxicosis/inducido químicamente , Tirotoxicosis/diagnóstico , Fibrilación Ventricular/tratamiento farmacológico , Fibrilación Ventricular/prevención & control , Adulto Joven
8.
Tex Heart Inst J ; 38(4): 418-20, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21841873

RESUMEN

Left ventricular reconstruction is advocated as a surgical option for patients with severe congestive heart failure. Despite initial enthusiasm for this procedure, reports of long-term results are sparse. Herein, we describe a particularly gratifying case of left ventricular reconstruction in a 43-year-old man, who continues to have excellent left ventricular function 10 years postoperatively. This approach may be a reasonable alternative to cardiac transplantation in patients who lack other treatment options.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Disfunción Ventricular Izquierda/cirugía , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Recuperación de la Función , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda
9.
J Heart Lung Transplant ; 30(8): 849-53, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21530318

RESUMEN

BACKGROUND: In this study we investigated gastrointestinal (GI) bleeding and its relationship to arteriovenous malformations (AVMs) in patients with the continuous-flow HeartMate II (HMII) left ventricular assist device (LVAD). METHODS: The records of 172 patients who received HMII support between November 2003 and June 2010 were reviewed. Patients were considered to have GI bleeding if they had 1 or more of the following symptoms: guaiac-positive stool; hematemesis; melena; active bleeding at the time of endoscopy or colonoscopy; and blood within the stomach at endoscopy or colonoscopy. The symptom(s) had to be accompanied by a decrease of >1 g/dl in the patient's hemoglobin level. The location of the bleeding was identified as upper GI tract, lower GI tract or both according to esophagogastroduodenoscopy, colonoscopy, small-bowel enteroscopy or mesenteric angiography. Post-LVAD implantation anti-coagulation therapy consisted of warfarin, aspirin and dipyridamole. RESULTS: Thirty-two of the 172 patients (19%) had GI bleeding after 63 ± 62 (range 8 to 241) days of HMII support. Ten patients had GI bleeding from an AVM; these included 3 patients who had 2 bleeding episodes and 2 patients who had 5 episodes each. Sixteen patients had upper GI bleeding (10 hemorrhagic gastritis, 4 gastric AVM, 2 Mallory-Weiss syndrome), 15 had lower GI bleeding (6 diverticulosis, 6 jejunal AVM, 1 drive-line erosion of the colon, 1 sigmoid polyp, 1 ischemic colitis) and 1 had upper and lower GI bleeding (1 colocutaneous and gastrocutaneous fistula). All GI bleeding episodes were successfully managed medically. CONCLUSIONS: Arteriovenous malformations can cause GI bleeding in patients with continuous-flow LVADs. In all cases in this series, GI bleeding was successfully managed without the need for surgical intervention.


Asunto(s)
Malformaciones Arteriovenosas/complicaciones , Malformaciones Arteriovenosas/epidemiología , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/etiología , Corazón Auxiliar , Disfunción Ventricular Izquierda/terapia , Adolescente , Adulto , Anciano , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Transfusión de Eritrocitos , Femenino , Hemorragia Gastrointestinal/terapia , Humanos , Masculino , Persona de Mediana Edad , Plasma , Prevalencia , Estudios Retrospectivos , Tromboembolia/prevención & control , Resultado del Tratamiento , Privación de Tratamiento , Adulto Joven
10.
N Engl J Med ; 364(15): 1395-406, 2011 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-21463154

RESUMEN

BACKGROUND: Mitral-valve repair can be accomplished with an investigational procedure that involves the percutaneous implantation of a clip that grasps and approximates the edges of the mitral leaflets at the origin of the regurgitant jet. METHODS: We randomly assigned 279 patients with moderately severe or severe (grade 3+ or 4+) mitral regurgitation in a 2:1 ratio to undergo either percutaneous repair or conventional surgery for repair or replacement of the mitral valve. The primary composite end point for efficacy was freedom from death, from surgery for mitral-valve dysfunction, and from grade 3+ or 4+ mitral regurgitation at 12 months. The primary safety end point was a composite of major adverse events within 30 days. RESULTS: At 12 months, the rates of the primary end point for efficacy were 55% in the percutaneous-repair group and 73% in the surgery group (P=0.007). The respective rates of the components of the primary end point were as follows: death, 6% in each group; surgery for mitral-valve dysfunction, 20% versus 2%; and grade 3+ or 4+ mitral regurgitation, 21% versus 20%. Major adverse events occurred in 15% of patients in the percutaneous-repair group and 48% of patients in the surgery group at 30 days (P<0.001). At 12 months, both groups had improved left ventricular size, New York Heart Association functional class, and quality-of-life measures, as compared with baseline. CONCLUSIONS: Although percutaneous repair was less effective at reducing mitral regurgitation than conventional surgery, the procedure was associated with superior safety and similar improvements in clinical outcomes. (Funded by Abbott Vascular; EVEREST II ClinicalTrials.gov number, NCT00209274.).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Anciano , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Insuficiencia de la Válvula Mitral/clasificación , Insuficiencia de la Válvula Mitral/mortalidad , Complicaciones Posoperatorias , Diseño de Prótesis , Calidad de Vida , Retratamiento , Resultado del Tratamiento
11.
Eur J Cardiothorac Surg ; 40(1): 227-32, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21273086

RESUMEN

OBJECTIVE: Off-pump coronary artery bypass surgery (OPCAB) and beating-heart coronary artery bypass grafting (BH-CAB) performed with cardiopulmonary bypass support are used with increasing frequency in the treatment of coronary artery occlusive disease. The utility of OPCAB and BH-CAB in treating high-risk patients has been studied, but the effects of these procedures on ventricular function have not been thoroughly investigated. METHODS: Data were collected from a database encompassing all patients who underwent isolated coronary revascularization performed by a single surgeon between August 2002 and March 2007. All procedures (n = 507) began as OPCAB operations, but 99 were converted to BH-CAB during surgery. Each patient's ejection fraction (EF) was measured preoperatively and postoperatively (median, 5.0 days after surgery). RESULTS: We found that although the BH-CAB patients tended to be in worse health and to have a lower preoperative EF than the OPCAB patients, both groups of patients had similar improvements in postoperative EF (6.8% vs 5.4%; p = 0.65). In addition, multivariable linear regression showed that a lower preoperative EF, age ≥ 70 years, and cardiomegaly predicted less postoperative EF improvement after coronary revascularization by either OPCAB or BH-CAB. CONCLUSIONS: Both OPCAB and BH-CAB procedures produce significant and similar short-term improvement in EF in patients with coronary disease. This change in EF may account for the subjective clinical improvements seen early after both procedures.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/métodos , Paro Cardíaco Inducido , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/complicaciones , Anciano , Biomarcadores/sangre , Contraindicaciones , Forma MB de la Creatina-Quinasa/sangre , Electrocardiografía , Femenino , Humanos , Masculino , Periodo Posoperatorio , Estudios Prospectivos , Sístole/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología
12.
J Thorac Cardiovasc Surg ; 140(5): 1181-8, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20546799

RESUMEN

OBJECTIVE: Controversy exists regarding the optimal pumping method for left ventricular assist devices. The purpose of this investigation was to test the hypothesis that pulsatile left ventricular assist synchronized to the cardiac cycle provides superior left ventricular unloading and circulatory support compared with continuous-flow left ventricular assist devices at the same level of ventricular assist device flow. METHODS: Seven male pigs were used to evaluate left ventricular assist device function using the TORVAD synchronized pulsatile-flow pump (Windmill Cardiovascular Systems, Inc, Austin, Tex) compared with the Bio-Medicus BPX-80 continuous-flow centrifugal pump (Medtronic, Inc, Minneapolis, Minn). Experiments were carried out under general anesthesia, and animals were instrumented via a median sternotomy. Hemodynamic measurements were obtained in the control state and with left ventricular assistance using the TORVAD and BPX-80 individually. Left ventricular failure was induced with suture ligation of the mid-left anterior descending coronary artery, and hemodynamic measurements were repeated. RESULTS: During left ventricular assist device support, mean aortic pressure and total cardiac output were higher and left atrial pressure was lower with pulsatile compared with continuous flow at the same ventricular assist device flow rate. During ischemic left ventricular failure, pulsatile left ventricular support resulted in higher total cardiac output (5.58 ± 1.58 vs 5.12 ± 1.19, P < .05), higher mean aortic pressure (67.8 ± 14 vs 60.2 ± 10, P < .05), and lower left atrial pressure (11.5 ± 3.5 vs 13.9 ± 6.0, P < .05) compared with continuous flow at the same left ventricular assist device flow rate. CONCLUSION: Synchronized, pulsatile left ventricular assistance produces superior left ventricular unloading and circulatory support compared with continuous-flow left ventricular assist at the same flow rates.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemodinámica , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Enfermedad Aguda , Animales , Aorta/fisiopatología , Función del Atrio Izquierdo , Presión Sanguínea , Gasto Cardíaco , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/fisiopatología , Masculino , Diseño de Prótesis , Flujo Pulsátil , Sus scrofa , Factores de Tiempo , Disfunción Ventricular Izquierda/fisiopatología
13.
Ann Thorac Surg ; 89(1): 24-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20103200

RESUMEN

BACKGROUND: Coronary artery shunting during off-pump coronary artery bypass OPCAB procedures has been addressed only infrequently. To assess the protective effect of shunting, we examined CABG patients' postoperative cardiac enzyme levels and preoperative and postoperative ejection fractions. METHODS: During OPCAB, we selectively shunted the left anterior descending coronary artery (LAD) to provide myocardial protection when ischemia developed. We prospectively gathered data from 408 consecutive patients who underwent OPCAB. Data on shunt status were available for 386 of these patients. A "flow-through" shunt providing perfusion to the distal LAD was used whenever ST-segment elevations greater than 2 mm occurred or when patients had hemodynamic compromise unexplained by cardiac manipulation. Ejection fraction was assessed 1 to 3 days preoperatively and again 3 to 10 days postoperatively. Creatine kinase (muscle/brain) levels were assessed postoperatively for 24 hours. RESULTS: During OPCAB, 99 patients required shunting for presumed ischemia. Thirty-day cardiac mortality was 1.4% (4 of 296 without a shunt; 0 of 90 with a shunt). In patients without a LAD shunt, the mean peak creatine kinase index was 5.3; in patients who needed a shunt, the index was 5.2. Mean ejection fraction improved from 0.536 to 0.589 in the shunted patients and from 0.53.5 to 0.586 in the nonshunted patients. CONCLUSIONS: Selective shunting of the LAD during OPCAB provides effective protection against myocardial ischemia when ischemia is detected by electrocardiogram or when hypotension develops that is unexplained by cardiac manipulation.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/métodos , Anastomosis Interna Mamario-Coronaria/métodos , Isquemia Miocárdica/cirugía , Anciano , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Estudios Prospectivos , Volumen Sistólico , Tasa de Supervivencia , Resultado del Tratamiento , Estados Unidos/epidemiología
14.
Ann Thorac Surg ; 89(1): 72-80; discussion p 80, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20103209

RESUMEN

BACKGROUND: Percutaneous mitral repair with the MitraClip device (Evalve, Menlo Park, CA) has been reported. Preserving conventional surgical options in the event of percutaneous treatment failure is important. We describe surgical treatment at varying intervals after the MitraClip procedure in 32 patients. METHODS: One hundred seven patients with moderate-to-severe or severe mitral regurgitation who were either symptomatic (91%) or, if asymptomatic (9%), had evidence of left ventricular dysfunction were enrolled as part of the Endovascular Valve Edge-to-Edge REpair STudy (EVEREST) phase I registry study or as "roll-in" subjects in the EVEREST II study. Thirty-two of the 107 patients (30%) underwent surgery after an attempted MitraClip procedure. RESULTS: Of the 32 patients undergoing post-clip mitral valve surgery, 23 patients (72%) had one or more clips implanted and 9 patients (28%) received no clip implant. The indications for mitral valve surgery in the 23 patients with a clip included partial clip detachment (n = 10), residual or recurrent mitral regurgitation greater than 2+ (n = 9), and other (atrial septal defect [n = 2], device malfunction [n = 1], and incorrectly diagnosed mitral stenosis [n = 1]). Twenty-seven of 31 patients (87%) underwent the surgical procedure planned before surgery (planned procedure unknown in 1 patient). Four of 25 patients (16%) with planned repair underwent mitral valve replacement. CONCLUSIONS: Standard surgical options were preserved in patients who had surgery after percutaneous repair with the MitraClip device. Successful repair was feasible in the majority of patients after the MitraClip procedure, with repair performed as late as 18 months after clip implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Reoperación/métodos , Técnicas de Sutura/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Recurrencia , Factores de Tiempo , Insuficiencia del Tratamiento
15.
J Heart Lung Transplant ; 27(7): 710-7, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18582798

RESUMEN

BACKGROUND: We hypothesized that not all subtypes of alpha- and beta-adrenoreceptors undergo similar upregulation and redistribution in human myocardium after mechanical unloading with an assist device. METHODS: We obtained core biopsy samples of the left ventricle in 19 patients before and after removal of a Jarvik or Thoratec left ventricular assist device (LVAD) to study the effect of mechanical unloading on the distribution of alpha- and beta-adrenoreceptors. Fresh, embedded tissue sections were incubated with receptor blockers and antibodies before the fluorescent labeling of receptors. Images were obtained by fluorescence deconvolution microscopy, and composite tissue renditions were made from the stacked images. Multiple adrenoreceptor subtypes were studied. RESULTS: We saw a reversal of myocyte hypertrophy in all patients, but the upregulation of receptors was not seen in all post-LVAD tissue samples. Furthermore, we noted receptor relocalization from an initial punctate/clumped pattern to a normal homogeneous distribution in many patients. Significant differences were seen in the distribution of beta(2)- and alpha(1)-receptors and in alpha(1A) subtypes. CONCLUSIONS: In this study we show not only the expected reversal of myocyte hypertrophy and the increase in adrenoreceptors after ventricular unloading, but also the relocalization of specific receptor subtypes.


Asunto(s)
Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/terapia , Miocardio/patología , Receptores Adrenérgicos alfa , Receptores Adrenérgicos beta , Adulto , Biopsia con Aguja , Femenino , Trasplante de Corazón , Corazón Auxiliar , Humanos , Masculino , Persona de Mediana Edad
16.
Tex Heart Inst J ; 33(2): 229-31, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16878634

RESUMEN

Left ventricular remodeling is becoming a frequent treatment for severe heart failure, but its use in combination with other surgical techniques is controversial. We report a case in which left ventricular remodeling was combined with coronary artery bypass grafting and mitral valve repair to treat a patient with severely depressed ejection fraction, mitral insufficiency, coronary artery disease, and a recent history of myocardial infarction. Cardiac function improved after the combined treatment. This case suggests that left ventricular remodeling can be used safely and effectively in conjunction with other surgical techniques.


Asunto(s)
Puente de Arteria Coronaria , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Válvula Mitral/cirugía , Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca/epidemiología , Humanos , Hipertensión Pulmonar/epidemiología , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Prótesis e Implantes
17.
Circulation ; 111(22): 3007-13, 2005 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-15939834

RESUMEN

New surgical procedures, imaging modalities, and medical devices have improved therapy for many patients and made treatment possible for others who have had few options in the past. In February 2004, the National Heart, Lung, and Blood Institute's (NHLBI) Advisory Council proposed that the institute evaluate the status and future directions in cardiac surgery. In response to this recommendation, the NHLBI convened a working group of cardiac surgeons on May 7 and 8, 2004, to assess the state of cardiac surgery research, identify critical gaps in current knowledge, determine areas of opportunity, and obtain specific recommendations for future research activities. The working group discussed surgical revascularization, novel surgical approaches, valvular research directions, biotechnology and cell-based therapy, heart failure, imaging modalities, and barriers to clinical research and presents its recommendations here.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/normas , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/tendencias , Trasplante de Células , Diagnóstico por Imagen/métodos , Predicción , Cardiopatías/patología , Cardiopatías/terapia , Humanos , Complicaciones Posoperatorias/prevención & control , Investigación
18.
Ann Thorac Surg ; 76(4): 1167-70, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14530006

RESUMEN

BACKGROUND: The Jarvik 2000 axial flow left ventricular assist device (LVAD), under development for the past decade, has the potential to support patients temporarily until cardiac transplantation or as a permanent circulatory support, without the size limitations of other implantable systems. METHODS: To assess its ability to perfuse the kidneys and liver, we monitored renal and hepatic function in 10 patients who received the Jarvik 2000 LVAD as a bridge to transplantation. Left ventricular assistance was maintained for up to 214 days (> 6 months), and renal and hepatic function were monitored at least weekly. RESULTS: Renal function before LVAD implantation in these patients was normal in 7 (creatinine, < 1.5) and moderately impaired in 3 (creatinine, 1.2 to 2.0). Hepatic function was normal in 7 patients before LVAD implantation (total bilirubin< 1.2; serum glutamic-oxaloacetic transaminase (SGOT), < 40; serum glutamic-pyruvic transaminase (SGPT), < 50) and normal at the time of transplantation in all 10 patients. Of the 3 patients with abnormal hepatic function before LVAD implantation, 1 patient had also had moderate renal dysfunction. CONCLUSIONS: Despite reduced pulsatility, the Jarvik 2000 LVAD improves or maintains excellent renal and hepatic function during periods of circulatory assistance in patients awaiting transplantation.


Asunto(s)
Corazón Auxiliar , Riñón/irrigación sanguínea , Hígado/irrigación sanguínea , Adulto , Anciano , Alanina Transaminasa/sangre , Aspartato Aminotransferasas/sangre , Bilirrubina/sangre , Cardiomiopatías/terapia , Creatinina/sangre , Femenino , Humanos , Riñón/fisiología , Hígado/fisiología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo
19.
Ann Thorac Surg ; 76(4): 1289-91, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14530033

RESUMEN

Reports of cardiac transplantation after successful cardiomyoplasty are rare. We report the case of a 63-year-old man with intractable heart failure who underwent successful orthotopic cardiac transplantation 30 months after dynamic cardiomyoplasty.


Asunto(s)
Cardiomioplastia , Trasplante de Corazón/métodos , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad
20.
Circulation ; 107(4): 538-44, 2003 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-12566363

RESUMEN

BACKGROUND: There are currently no data on the accuracy of intravenous myocardial contrast echocardiography (MCE) in detecting myocardial hibernation in man and its comparative accuracy to dobutamine echocardiography (DE) or thallium 201 (Tl(201)) scintigraphy. METHODS AND RESULTS: Twenty patients with coronary artery disease and ventricular dysfunction underwent MCE 1 to 5 days before bypass surgery and repeat echocardiography at 3 to 4 months. Patients also underwent DE (n=18) and rest-redistribution Tl(201) tomography (n=16) before revascularization. MCE was performed using continuous Optison infusion (12 to 16 cc/h) with intermittent pulse inversion harmonics and incremental triggering (1:1 to 1:8). Myocardial contrast intensity (MCI) replenishment curves were constructed to derive quantitative MCE indices of blood velocity and flow. Recovery of function occurred in 38% of dysfunctional segments. MCE parameters of perfusion in hibernating myocardium were similar to segments with normal function and higher than dysfunctional myocardium without recovery of function (P<0.001). The best MCE parameter for predicting functional recovery was Peak MCIxbeta, an index of myocardial blood flow (area under the curve, 0.83). MCE parameters were higher in segments with contractile reserve and Tl(201) uptake > or =60% (P<0.05) and identified viable segments without contractile reserve by DE. The sensitivity of Peak MCIxbeta >1.5 dB/s for recovery of function was 90% and was similar to Tl(201) scintigraphy (92%) and any contractile reserve (80%); specificity was higher than for Tl(201) and DE (63%, 45%, and 54%, respectively; P<0.05). CONCLUSIONS: MCE with intravenous contrast identifies myocardial hibernation in humans. Prediction of viable myocardium with MCE is best using quantification of myocardial blood flow and provides improved accuracy compared with DE and Tl(201) scintigraphy.


Asunto(s)
Medios de Contraste/administración & dosificación , Dobutamina , Ecocardiografía , Aturdimiento Miocárdico/diagnóstico , Radioisótopos de Talio , Anciano , Velocidad del Flujo Sanguíneo , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Circulación Coronaria , Femenino , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Aturdimiento Miocárdico/diagnóstico por imagen , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Cintigrafía , Recuperación de la Función , Sensibilidad y Especificidad , Disfunción Ventricular/diagnóstico , Disfunción Ventricular/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA