Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
JAMA Cardiol ; 7(11): 1160-1169, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36197675

RESUMEN

Importance: The risk of adverse events from ascending thoracic aorta aneurysm (TAA) is poorly understood but drives clinical decision-making. Objective: To evaluate the association of TAA size with outcomes in nonsyndromic patients in a large non-referral-based health care delivery system. Design, Setting, and Participants: The Kaiser Permanente Thoracic Aortic Aneurysm (KP-TAA) cohort study was a retrospective cohort study at Kaiser Permanente Northern California, a fully integrated health care delivery system insuring and providing care for more than 4.5 million persons. Nonsyndromic patients from a regional TAA safety net tracking system were included. Imaging data including maximum TAA size were merged with electronic health record (EHR) and comprehensive death data to obtain demographic characteristics, comorbidities, medications, laboratory values, vital signs, and subsequent outcomes. Unadjusted rates were calculated and the association of TAA size with outcomes was evaluated in multivariable competing risk models that categorized TAA size as a baseline and time-updated variable and accounted for potential confounders. Data were analyzed from January 2018 to August 2021. Exposures: TAA size. Main Outcomes and Measures: Aortic dissection (AD), all-cause death, and elective aortic surgery. Results: Of 6372 patients with TAA identified between 2000 and 2016 (mean [SD] age, 68.6 [13.0] years; 2050 female individuals [32.2%] and 4322 male individuals [67.8%]), mean (SD) initial TAA size was 4.4 (0.5) cm (828 individuals [13.0% of cohort] had initial TAA size 5.0 cm or larger and 280 [4.4%] 5.5 cm or larger). Rates of AD were low across a mean (SD) 3.7 (2.5) years of follow-up (44 individuals [0.7% of cohort]; incidence 0.22 events per 100 person-years). Larger initial aortic size was associated with higher risk of AD and all-cause death in multivariable models, with an inflection point in risk at 6.0 cm. Estimated adjusted risks of AD within 5 years were 0.3% (95% CI, 0.3-0.7), 0.6% (95% CI, 0.4-1.3), 1.5% (95% CI, 1.2-3.9), 3.6% (95% CI, 1.8-12.8), and 10.5% (95% CI, 2.7-44.3) in patients with TAA size of 4.0 to 4.4 cm, 4.5 to 4.9 cm, 5.0 to 5.4 cm, 5.5 to 5.9 cm, and 6.0 cm or larger, respectively, in time-updated models. Rates of the composite outcome of AD and all-cause death were higher than for AD alone, but a similar inflection point for increased risk was observed at 6.0 cm. Conclusions and Relevance: In a large sociodemographically diverse cohort of patients with TAA, absolute risk of aortic dissection was low but increased with larger aortic sizes after adjustment for potential confounders and competing risks. Our data support current consensus guidelines recommending prophylactic surgery in nonsyndromic individuals with TAA at a 5.5-cm threshold.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Humanos , Masculino , Femenino , Anciano , Aneurisma de la Aorta Torácica/epidemiología , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Estudios de Cohortes , Disección Aórtica/diagnóstico , Incidencia
2.
JAMA Cardiol ; 7(4): 386-395, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35195663

RESUMEN

IMPORTANCE: Early detection and characterization of increased left ventricular (LV) wall thickness can markedly impact patient care but is limited by under-recognition of hypertrophy, measurement error and variability, and difficulty differentiating causes of increased wall thickness, such as hypertrophy, cardiomyopathy, and cardiac amyloidosis. OBJECTIVE: To assess the accuracy of a deep learning workflow in quantifying ventricular hypertrophy and predicting the cause of increased LV wall thickness. DESIGN, SETTINGS, AND PARTICIPANTS: This cohort study included physician-curated cohorts from the Stanford Amyloid Center and Cedars-Sinai Medical Center (CSMC) Advanced Heart Disease Clinic for cardiac amyloidosis and the Stanford Center for Inherited Cardiovascular Disease and the CSMC Hypertrophic Cardiomyopathy Clinic for hypertrophic cardiomyopathy from January 1, 2008, to December 31, 2020. The deep learning algorithm was trained and tested on retrospectively obtained independent echocardiogram videos from Stanford Healthcare, CSMC, and the Unity Imaging Collaborative. MAIN OUTCOMES AND MEASURES: The main outcome was the accuracy of the deep learning algorithm in measuring left ventricular dimensions and identifying patients with increased LV wall thickness diagnosed with hypertrophic cardiomyopathy and cardiac amyloidosis. RESULTS: The study included 23 745 patients: 12 001 from Stanford Health Care (6509 [54.2%] female; mean [SD] age, 61.6 [17.4] years) and 1309 from CSMC (808 [61.7%] female; mean [SD] age, 62.8 [17.2] years) with parasternal long-axis videos and 8084 from Stanford Health Care (4201 [54.0%] female; mean [SD] age, 69.1 [16.8] years) and 2351 from CSMS (6509 [54.2%] female; mean [SD] age, 69.6 [14.7] years) with apical 4-chamber videos. The deep learning algorithm accurately measured intraventricular wall thickness (mean absolute error [MAE], 1.2 mm; 95% CI, 1.1-1.3 mm), LV diameter (MAE, 2.4 mm; 95% CI, 2.2-2.6 mm), and posterior wall thickness (MAE, 1.4 mm; 95% CI, 1.2-1.5 mm) and classified cardiac amyloidosis (area under the curve [AUC], 0.83) and hypertrophic cardiomyopathy (AUC, 0.98) separately from other causes of LV hypertrophy. In external data sets from independent domestic and international health care systems, the deep learning algorithm accurately quantified ventricular parameters (domestic: R2, 0.96; international: R2, 0.90). For the domestic data set, the MAE was 1.7 mm (95% CI, 1.6-1.8 mm) for intraventricular septum thickness, 3.8 mm (95% CI, 3.5-4.0 mm) for LV internal dimension, and 1.8 mm (95% CI, 1.7-2.0 mm) for LV posterior wall thickness. For the international data set, the MAE was 1.7 mm (95% CI, 1.5-2.0 mm) for intraventricular septum thickness, 2.9 mm (95% CI, 2.4-3.3 mm) for LV internal dimension, and 2.3 mm (95% CI, 1.9-2.7 mm) for LV posterior wall thickness. The deep learning algorithm accurately detected cardiac amyloidosis (AUC, 0.79) and hypertrophic cardiomyopathy (AUC, 0.89) in the domestic external validation site. CONCLUSIONS AND RELEVANCE: In this cohort study, the deep learning model accurately identified subtle changes in LV wall geometric measurements and the causes of hypertrophy. Unlike with human experts, the deep learning workflow is fully automated, allowing for reproducible, precise measurements, and may provide a foundation for precision diagnosis of cardiac hypertrophy.


Asunto(s)
Amiloidosis , Cardiomiopatía Hipertrófica , Aprendizaje Profundo , Anciano , Amiloidosis/diagnóstico , Amiloidosis/diagnóstico por imagen , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
JACC Case Rep ; 3(9): 1177-1181, 2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-34401754

RESUMEN

Coronary artery vasospasm is typically managed through avoidance of triggers and with symptomatic treatments with calcium channel blockers and long-acting nitrates. Here, we report a rare case of medically refractory coronary artery vasospasm associated with genetic predispositions that initially required cardiac autotransplantation followed paradoxically by nicotine for long-term symptomatic control. (Level of Difficulty: Intermediate.).

4.
Front Immunol ; 11: 587089, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33072134

RESUMEN

Autoimmune and autoinflammatory diseases of the medium and large arteries, including the aorta, cause life-threatening complications due to vessel wall destruction but also by wall remodeling, such as the formation of wall-penetrating microvessels and lumen-stenosing neointima. The two most frequent large vessel vasculitides, giant cell arteritis (GCA) and Takayasu arteritis (TAK), are HLA-associated diseases, strongly suggestive for a critical role of T cells and antigen recognition in disease pathogenesis. Recent studies have revealed a growing spectrum of effector functions through which T cells participate in the immunopathology of GCA and TAK; causing the disease-specific patterning of pathology and clinical outcome. Core pathogenic features of disease-relevant T cells rely on the interaction with endothelial cells, dendritic cells and macrophages and lead to vessel wall invasion, formation of tissue-damaging granulomatous infiltrates and induction of the name-giving multinucleated giant cells. Besides antigen, pathogenic T cells encounter danger signals in their immediate microenvironment that they translate into disease-relevant effector functions. Decisive signaling pathways, such as the AKT pathway, the NOTCH pathway, and the JAK/STAT pathway modify antigen-induced T cell activation and emerge as promising therapeutic targets to halt disease progression and, eventually, reset the immune system to reestablish the immune privilege of the arterial wall.


Asunto(s)
Arteritis de Células Gigantes/inmunología , Transducción de Señal/inmunología , Arteritis de Takayasu/inmunología , Animales , Arteritis de Células Gigantes/patología , Humanos , Arteritis de Takayasu/patología
5.
Curr Rheumatol Rep ; 22(10): 68, 2020 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-32845392

RESUMEN

PURPOSE OF REVIEW: Giant cell arteritis (GCA) and Takayasu arteritis (TAK) are auto-inflammatory and autoimmune diseases with a highly selective tissue tropism for medium and large arteries. In both diseases, CD4+ T cells and macrophages form granulomatous lesions within the arterial wall, a tissue site normally protected by immune privilege. Vascular lesions can be accompanied by an extravascular component, typically an intense hepatic acute phase response that produces well-known laboratory abnormalities, e.g., elevated ESR and CRP. It is unclear whether GCA and TAK lie on a spectrum of disease or whether they represent fundamentally different disease processes. RECENT FINDINGS: GCA and TAK share many clinical features, but there are substantial differences in genetics, epidemiology, disease mechanisms, response to treatment, and treatment complications that give rise to different disease trajectories. A significant difference lies in the composition of the wall-infiltrating immune cell compartment, which in TAK includes a significant population of CD8+ T cells as well as natural killer cells, specifying disparate disease effector pathways mediating tissue damage and vessel wall remodeling. Despite the similarities in tissue tropism and histomorphology, GCA and TAK are two distinct vasculitides that rely on separate disease mechanisms and require disease-specific approaches in diagnosis and management.


Asunto(s)
Arteritis de Células Gigantes , Arteritis de Takayasu , Linfocitos T CD8-positivos , Diagnóstico Diferencial , Arteritis de Células Gigantes/diagnóstico , Arteritis de Células Gigantes/patología , Humanos , Células Asesinas Naturales , Macrófagos , Arteritis de Takayasu/diagnóstico , Arteritis de Takayasu/patología
6.
Front Immunol ; 11: 621098, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33717054

RESUMEN

Autoimmune diseases can afflict every organ system, including blood vessels that are critically important for host survival. The most frequent autoimmune vasculitis is giant cell arteritis (GCA), which causes aggressive wall inflammation in medium and large arteries and results in vaso-occlusive wall remodeling. GCA shares with other autoimmune diseases that it occurs in genetically predisposed individuals, that females are at higher risk, and that environmental triggers are suspected to beget the loss of immunological tolerance. GCA has features that distinguish it from other autoimmune diseases and predict the need for tailored diagnostic and therapeutic approaches. At the core of GCA pathology are CD4+ T cells that gain access to the protected tissue niche of the vessel wall, differentiate into cytokine producers, attain tissue residency, and enforce macrophages differentiation into tissue-destructive effector cells. Several signaling pathways have been implicated in initiating and sustaining pathogenic CD4+ T cell function, including the NOTCH1-Jagged1 pathway, the CD28 co-stimulatory pathway, the PD-1/PD-L1 co-inhibitory pathway, and the JAK/STAT signaling pathway. Inadequacy of mechanisms that normally dampen immune responses, such as defective expression of the PD-L1 ligand and malfunction of immunosuppressive CD8+ T regulatory cells are a common theme in GCA immunopathology. Recent studies are providing a string of novel mechanisms that will permit more precise pathogenic modeling and therapeutic targeting in GCA and will fundamentally inform how abnormal immune responses in blood vessels lead to disease.


Asunto(s)
Inmunidad Adaptativa , Arteritis de Células Gigantes/inmunología , Inmunidad Innata , Traslado Adoptivo , Animales , Anticuerpos Monoclonales Humanizados/uso terapéutico , Presentación de Antígeno , Arterias/trasplante , Antígeno B7-H1/fisiología , Células Dendríticas/inmunología , Trampas Extracelulares/inmunología , Femenino , Arteritis de Células Gigantes/tratamiento farmacológico , Arteritis de Células Gigantes/patología , Humanos , Memoria Inmunológica , Activación de Linfocitos , Subgrupos Linfocitarios/inmunología , Macrófagos/inmunología , Macrófagos/patología , Masculino , Metaloproteinasa 9 de la Matriz/fisiología , Ratones , Ratones SCID , Monocitos/inmunología , Monocitos/patología , Receptor de Muerte Celular Programada 1/fisiología , Investigación Biomédica Traslacional
7.
J Thorac Cardiovasc Surg ; 158(4): 1058-1068, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30803776

RESUMEN

OBJECTIVE: To quantify the effects of annuloplasty rings designed to treat ischemic/functional mitral regurgitation on left ventricular septal-lateral (S-L) and commissure-commissure (C-C) dimensions. METHODS: Radiopaque markers were placed as opposing pairs on the S-L and C-C aspects of the mitral annulus and the basal, equatorial, and apical level of the left ventricle (LV) in 30 sheep. Ten true-sized Carpentier-Edwards Physio (PHY), Edwards IMR ETlogix (ETL), and GeoForm (GEO; all from Edwards Lifesciences, Irvine, Calif) annuloplasty rings were inserted in a releasable fashion. After 90 seconds of left circumflex artery occlusion with the ring implanted (RING), 4-dimensional marker coordinates were obtained using biplane videofluoroscopy. After ring release, another data set was acquired after another 90 seconds of left circumflex artery occlusion (NO RING). S-L and C-C diameters were computed as the distances between the respective marker pairs at end-diastole. Percent change in diameters was calculated between RING versus NO RING as 100 × (diameter in centimeters [RING] - diameter in centimeters [NO RING])/diameter in centimeters [NO RING]). RESULTS: Compared with NO RING, all ring types (PHY, ETL, and GEO) reduced mitral annular S-L dimensions by -20.7 ± 5.6%, -26.8 ± 3.9%, and -34.5 ± 3.8%, respectively. GEO reduced the S-L dimensions of the LV at the basal level only by -2.3 ± 2.4%, whereas all other S-L dimensions of the LV remained unchanged with all 3 rings implanted. PHY, ETL, and GEO reduced mitral annular C-C dimensions by -17.5 ± 4.8%, -19.6 ± 2.5, and -8.3 ± 4.9%, respectively, but none of the rings altered the C-C dimensions of the LV. CONCLUSIONS: Despite radical reduction of mitral annular size, disease-specific ischemic/functional mitral regurgitation annuloplasty rings do not induce relevant changes of left ventricular dimensions in the acutely ischemic ovine heart.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Isquemia Miocárdica/complicaciones , Animales , Modelos Animales de Enfermedad , Marcadores Fiduciales , Fluoroscopía/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos/fisiopatología , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Diseño de Prótesis , Oveja Doméstica , Función Ventricular Izquierda
8.
J Thorac Cardiovasc Surg ; 150(1): 59-68, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25956338

RESUMEN

OBJECTIVE: To evaluate the role of commissure orientation on downstream blood flow patterns and ascending aortic wall shear stress (WSS) in patients with bicuspid aortic valves (BAV) after valve-sparing aortic root replacement (V-SARR). METHODS: Nineteen BAV patients after V-SARR (9 Sievers' type 1/LR [type 1 valve with fusion of the left and right cusps] and 10 Sievers' type 0/LAT ["naturally perfect"; type 0 valve without the presence of a raphe, and with the 2 commissures oriented right-anterior-to-left-posterior]) were imaged using time-resolved 3-D phase contrast magnetic resonance imaging. A control group of 5 unoperated tricuspid aortic valve patients were used for comparison purposes. Wall shear stress and eccentricity of flow normalized to aortic diameter were measured in planes placed perpendicular to the axis of the ascending aorta at the level of the sinotubular junction (proximal ascending), main pulmonary artery (mid-ascending), and origin of the brachiocephalic (distal ascending). RESULTS: The ratio of WSS along the outer curvature to that along the inner curvature was greater in Sievers' type 1/LR patients compared with Sievers' type 0/LAT patients in the proximal (3.8 ± 1.6 vs 2.1 ± 0.9, P = .009) and mid- ascending aorta (4.5 ± 2.4 vs 2.4 ± 1.3, P = .027). Relative to control normal tricuspid patients, Sievers' type 1/LR BAV patients had a higher WSS ratio in the mid-ascending aorta (4.5 ± 2.4 vs 1.2 ± 1.2, P = .007). Conversely, WSS in Sievers' type 0/LAT patients was not different than in normal tricuspid patients. CONCLUSIONS: After V-SARR, BAV cusp morphology has a major impact on the pattern of blood flow and WSS in the ascending aorta.


Asunto(s)
Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Flujo Sanguíneo Regional , Estrés Mecánico , Adulto , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Adulto Joven
9.
Interact Cardiovasc Thorac Surg ; 19(3): 375-81; discussion 381, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24903440

RESUMEN

OBJECTIVES: A 180/180° configuration has been reported to increase repair durability after valve-sparing aortic root replacement (V-SARR) for bicuspid aortic valve (BAV) disease. We studied the impact of commissural angular configuration (CAC) and of BAV type on valve performance after V-SARR. METHODS: A total of 85 BAV patients (68 males, age 44 ± 11 years) underwent Tirone David-V V-SARR between 1997 and 2013. BAV type was documented intraoperatively, and CAC determined from pre- and postoperative computed tomography scans as the angle subtended by the non-fused cusp. Transthoracic echocardiogram was performed at 6 ± 3 days and at 2.9 ± 2.1 years. Functional end-points included freedom from aortic regurgitation (AR) 1+, AR 2+ and freedom from AR progression (0 to 1+, or 1+ to 2+). Tested variables included preoperative CAC (>160 vs <160°) and changes in CAC after V-SARR (Δ > 30° vs Δ < 30°) and Sievers' BAV type (SØ or S1). RESULTS: CAC in SØ-BAV (n = 26) changed minimally from 164 ± 12 to 171 ± 11° (mean Δ = 7.2 ± 16°, P = 0.044), whereas in S1-BAV (n = 59) CAC changed substantially from 132 ± 19 to 156 ± 18° (mean Δ = 27 ± 21°, P < 0.001). Larger postoperative CAC angles were not linked to better mid-term valve performance, but Sievers' BAV type had a major effect on valve performance: mild AR in S1/i BAV progressed more often (76 vs 32% at 4 years, P = 0.017) and 1+ AR was more frequent (70 vs 36% at 4 years, P = 0.008) compared with SØ-BAV. CONCLUSIONS: BAV type, including number of raphes, sinuses and commissures (SØ superior to S1) but not commissure geometry within the neoroot alone, appears to be linked to functional outcomes after V-SARR for BAV.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/anomalías , Implantación de Prótesis Vascular/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Adulto , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Enfermedad de la Válvula Aórtica Bicúspide , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
10.
J Thorac Cardiovasc Surg ; 147(1): 169-77, 178.e1-178.e3, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24176278

RESUMEN

OBJECTIVE: The study objective was to determine whether recurrent or residual mild aortic regurgitation, which occurs after valve-sparing aortic root replacement, progresses over time. METHODS: Between 2003 and 2008, 154 patients underwent Tirone David-V valve-sparing aortic root replacement; 96 patients (62%) had both 1-year (median, 12 ± 4 months) and mid-term (62 ± 22 months) transthoracic echocardiograms available for analysis. Age of patients averaged 38 ± 13 years, 71% were male, 31% had a bicuspid aortic valve, 41% had Marfan syndrome, and 51% underwent aortic valve repair, predominantly cusp free margin shortening. RESULTS: Forty-one patients (43%) had mild aortic regurgitation on 1-year echocardiogram. In 85% of patients (n = 35), mild aortic regurgitation remained stable on the most recent echocardiogram (median, 57 ± 20 months); progression to moderate aortic regurgitation occurred in 5 patients (12%) at a median of 28 ± 18 months and remained stable thereafter; severe aortic regurgitation developed in 1 patient, eventually requiring reoperation. Five patients (5%) had moderate aortic regurgitation at 1 year, which did not progress subsequently. Two patients (2%) had more than moderate aortic regurgitation at 1 year, and both ultimately required reoperation. CONCLUSIONS: Although mild aortic regurgitation occurs frequently after valve-sparing aortic root replacement, it is unlikely to progress over the next 5 years and should not be interpreted as failure of the valve-preservation concept. Further, we suggest that mild aortic regurgitation should not be considered nonstructural valve dysfunction, as the 2008 valve reporting guidelines would indicate. We need 10- to 15-year follow-up to learn the long-term clinical consequences of mild aortic regurgitation early after valve-sparing aortic root replacement.


Asunto(s)
Aorta/cirugía , Insuficiencia de la Válvula Aórtica/epidemiología , Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Reimplantación/efectos adversos , Adolescente , Adulto , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/métodos , Distribución de Chi-Cuadrado , Niño , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estimación de Kaplan-Meier , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Recurrencia , Reoperación , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
11.
J Thorac Cardiovasc Surg ; 145(1): 117-26, 127.e1-5; discussion 126-7, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23083792

RESUMEN

OBJECTIVE: Although implicitly accepted by many that the durability of valve-sparing aortic root replacement in patients with bicuspid aortic valve disease and connective tissue disorders will be inferior, this hypothesis has not been rigorously investigated. METHODS: From 1993 to 2009, 233 patients (27% bicuspid aortic valve, 40% Marfan syndrome) underwent Tirone David valve-sparing aortic root replacement. Follow-up averaged 4.7 ± 3.3 years (1102 patient-years). Freedom from adverse outcomes was determined using log-rank calculations. RESULTS: Survival at 5 and 10 years was 98.7% ± 0.7% and 93.5% ± 5.1%, respectively. Freedom from reoperation (all causes) on the aortic root was 92.2% ± 3.6% at 10 years; 3 reoperations were aortic valve replacement owing to structural valve deterioration. Freedom from structural valve deterioration at 10 years was 96.1% ± 2.1%. No significant differences were found in survival (P = .805, P = .793, respectively), reoperation (P = .179, P = .973, respectively), structural valve deterioration (P = .639, P = .982, respectively), or any other functional or clinical endpoints when patients were stratified by valve type (tricuspid aortic valve vs bicuspid aortic valve) or associated connective tissue disorder. At the latest echocardiographic follow-up (95% complete), 202 patients (94.8%) had none or trace aortic regurgitation, 10 (4.7%) mild, 0 had moderate to severe, and 1 (0.5%) had severe aortic regurgitation. Freedom from greater than 2+ aortic regurgitation at 10 years was 95.3% ± 2.5%. Six patients sustained acute type B aortic dissection (freedom at 10 years, 90.4% ± 5.0%). CONCLUSIONS: Tirone David reimplantation valve-sparing aortic root replacement in carefully selected young patients was associated with excellent clinical and echocardiographic outcome in patients with either a tricuspid aortic valve or bicuspid aortic valve. No demonstrable adverse influence was found for Marfan syndrome or connective tissue disorder on durability, clinical outcome, or echocardiographic results.


Asunto(s)
Aorta/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis Vascular , Cardiopatías Congénitas/cirugía , Síndrome de Marfan/complicaciones , Adolescente , Adulto , Anciano , Válvula Aórtica/anomalías , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Distribución de Chi-Cuadrado , Niño , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/mortalidad , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Síndrome de Marfan/mortalidad , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Reoperación , Reimplantación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
J Thorac Cardiovasc Surg ; 145(3 Suppl): S35-40.e1-2, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23260433

RESUMEN

OBJECTIVES: The durability of valve-sparing aortic root replacement with or without cusp repair in patients with bicuspid aortic valve (BAV) disease is questioned. We analyzed the results of 75 patients with a BAV undergoing Tirone David reimplantation valve-sparing aortic root replacement. METHODS: Average age was 45 ± 10 years; 80% were male; 31% had 2+ or greater aortic regurgitation (AR); annular diameter averaged 28 ± 3 mm; 32% had a Sievers' type 0 BAV, and 66% underwent concomitant cusp repair (usually cusp free margin shortening) to correct prolapse. Early (6 ± 3 days) and late (2.9 ± 1.7, 1-10 years) postoperative echocardiographic results were compared (cumulative echocardiographic follow-up, 190 patient-years; median late interval, 2 years [interquartile range, 0.68, 4.2]). Seven patients remained at risk beyond 6 years. Clinical outcome and valve function were analyzed using log-rank calculations. RESULTS: Actuarial survival was 99% ± 2%; freedom from reoperation was 90% ± 5%, infection 98% ± 2%, and stroke 100% at 6 years. After initial improvement in degree of AR (P < .001), minor subclinical progression of AR was observed (P > .5); however, freedom from AR of more than 2+ was 100%. Cusp free margin shortening was not associated with valve deterioration, but commissural suspensory polytetrafluoroethylene neochord creation (n = 4) portended a higher probability of recurrent AR (P = .025). CONCLUSIONS: After David procedure and cusp repair in patients with a BAV, midterm clinical and valve function outcomes were favorable out to 6 years. More follow-up is required to determine long-term valve durability and the hazard of other clinically important late adverse events, including eventual reoperation, to beyond 10 years.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis Vascular , Anuloplastia de la Válvula Cardíaca , Cardiopatías Congénitas/cirugía , Reimplantación , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Anuloplastia de la Válvula Cardíaca/efectos adversos , Anuloplastia de la Válvula Cardíaca/mortalidad , Enfermedades Transmisibles/etiología , Enfermedades Transmisibles/cirugía , Supervivencia sin Enfermedad , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/fisiopatología , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación , Reimplantación/efectos adversos , Reimplantación/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía , Adulto Joven
13.
Ultrasound Med Biol ; 37(12): 2037-54, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22014856

RESUMEN

We present a method for real-time, freehand 3D ultrasound (3D-US) reconstruction of moving anatomy, with specific application towards guiding the catheter ablation procedure in the left atrium. Using an intracardiac echo (ICE) catheter with a pose (position/orientation) sensor mounted to its tip, we continually mosaic 2D-ICE images of a left atrium phantom model to form a 3D-US volume. Our mosaicing strategy employs a probabilistic framework based on simultaneous localization and mapping (SLAM), a technique commonly used in mobile robotics for creating maps of unexplored environments. The measured ICE catheter tip pose provides an initial estimate for compounding 2D-ICE image data into the 3D-US volume. However, we simultaneously consider the overlap-consistency shared between 2D-ICE images and the 3D-US volume, computing a "corrected" tip pose if need be to ensure spatially-consistent reconstruction. This allows us to compensate for anatomic movement and sensor drift that would otherwise cause motion artifacts in the 3D-US volume. Our approach incorporates 2D-ICE data immediately after acquisition, allowing us to continuously update the registration parameters linking sensor coordinates to 3D-US coordinates. This, in turn, enables real-time localization and display of sensorized therapeutic catheters within the 3D-US volume for facilitating procedural guidance.


Asunto(s)
Algoritmos , Ablación por Catéter/métodos , Ecocardiografía Tridimensional/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Interpretación de Imagen Asistida por Computador/métodos , Cirugía Asistida por Computador/métodos , Humanos , Aumento de la Imagen/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
J Thorac Cardiovasc Surg ; 141(2): 345-53, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21241857

RESUMEN

OBJECTIVE: The study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia. METHODS: Radiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion. Marker coordinates were obtained using biplane videofluoroscopy with ring inserted at baseline (RING_BL) and after 90 seconds of left circumflex artery occlusion (RING_ISCH). After ring release, another dataset was acquired before (No_Ring_BL) and after left circumflex artery occlusion (No_Ring_ISCH). Anterior and posterior mitral leaflet tenting areas were computed at mid-systole from sums of marker triangles with the midpoint between the annular markers being the vertex for all triangles. RESULTS: Compared with No_Ring_BL, mitral regurgitation grades and all tenting areas significantly increased with No_Ring_ISCH. Compared with No_Ring_ISCH, (1) all rings significantly prevented mitral regurgitation and reduced all tenting areas; (2) Edwards IMR ETLogix and GeoForm rings reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, to a significantly greater extent than the Carpentier-Edwards Physio ring; and (3) Edwards IMR ETLogix and GeoForm rings affected tenting areas similarly. CONCLUSIONS: In response to acute left ventricular ischemia, disease-specific functional/ischemic mitral regurgitation rings (Edwards IMR ETLogix, GeoForm) more effectively reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, compared with true-sized physiologic rings (Carpentier-Edwards Physio). Despite its radical 3-dimensional shape and greater amount of mitral annular septal-lateral downsizing, the GeoForm ring did not reduce tenting areas more than the Edwards IMR ETLogix ring, suggesting that further reduction in tenting areas in patients with FMR/IMR may not be effectively achieved on an annular level.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/prevención & control , Válvula Mitral/cirugía , Isquemia Miocárdica/fisiopatología , Animales , Modelos Animales de Enfermedad , Fluoroscopía , Hemodinámica , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , Diseño de Prótesis , Ovinos , Función Ventricular Izquierda , Grabación en Video
15.
Artículo en Inglés | MEDLINE | ID: mdl-19964395

RESUMEN

We present a method for registering real-time ultrasound of the left atrium to an outdated, anatomic surface mesh model, whose shape differs from that of the anatomy. Using an intracardiac echo (ICE) catheter with mounted 6DOF electromagnetic position/orientation sensor (EPS), we acquire images of the left atrium and determine where the ICE catheter must be positioned relative to the surface mesh to generate similar, "virtual" ICE images. Further, we use an affine warping model to infer how the shape of the surface mesh differs from that of the atrium. Our registration and warping algorithm allows us to display EPS-sensorized catheters inside the surface mesh, facilitating guidance for left atrial procedures. By solving for the atrium-to-mesh warping parameters, we ensure that tissue contact in the anatomy is properly displayed as tissue contact in the mesh. After considering less than thirty seconds worth of ICE data, we are able to accurately localize EPS measurements within the surface mesh, despite surface mesh warpings of up to +/-20% along and about the principal axes of the left atrium. Further, because our estimation framework is iterative and continuous, our accuracy improves as new data is acquired.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Ablación por Catéter/instrumentación , Atrios Cardíacos/anatomía & histología , Atrios Cardíacos/cirugía , Magnetismo/instrumentación , Modelos Anatómicos , Cirugía Asistida por Computador/métodos , Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Magnetismo/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/instrumentación
16.
Int J Comput Assist Radiol Surg ; 4(5): 425-37, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20033525

RESUMEN

INTRODUCTION: The catheter ablation procedure is a minimally invasive surgery used to treat atrial fibrillation. Difficulty visualizing the catheter inside the left atrium anatomy has led to lengthy procedure times and limited success rates. In this paper, we present a set of algorithms for reconstructing 3D ultrasound data of the left atrium in real-time, with an emphasis on automatic tissue classification for improved clarity surrounding regions of interest. METHODS: Using an intracardiac echo (ICE) ultrasound catheter, we collect 2D-ICE images of a left atrium phantom from multiple configurations and iteratively compound the acquired data into a 3D-ICE volume. We introduce two new methods for compounding overlapping US data-occupancy-likelihood and response-grid compounding-which automatically classify voxels as "occupied" or "clear," and mitigate reconstruction artifacts caused by signal dropout. Finally, we use the results of an ICE-to-CT registration algorithm to devise a response-likelihood weighting scheme, which assigns weights to US signals based on the likelihood that they correspond to tissue-reflections. RESULTS: Our algorithms successfully reconstruct a 3D-ICE volume of the left atrium with voxels classified as "occupied" or "clear," even within difficult-to-image regions like the pulmonary vein openings. We are robust to dropout artifact that plagues a subset of the 2D-ICE images, and our weighting scheme assists in filtering out spurious data attributed to ghost-signals from multi-path reflections. By automatically classifying tissue, our algorithm precludes the need for thresholding, a process that is difficult to automate without subjective input. Our hope is to use this result towards developing 3D ultrasound segmentation algorithms in the future.


Asunto(s)
Algoritmos , Ablación por Catéter , Ecocardiografía Tridimensional , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Cirugía Asistida por Computador , Atrios Cardíacos/cirugía , Humanos , Tamaño de los Órganos , Fantasmas de Imagen , Reproducibilidad de los Resultados
17.
Sens Actuators A Phys ; 147(1): 83-92, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-19759806

RESUMEN

Catheter-based interventions are a form of minimally invasive surgery that can decrease hospitalization time and greatly lower patient morbidity compared to traditional methods. However, percutaneous catheter procedures are hindered by a lack of precise tip manipulation when actuation forces are transmitted over the length of the catheter. Active catheters with local shape-memory-alloy (SMA) actuation can potentially provide the desired manipulation of a catheter tip, but hysteresis makes it difficult to control the actuators. A method to integrate small-volume, compliant sensors on an active catheter to provide position feedback for control would greatly improve the viability of SMA-based active catheters. In this work, we describe the design, fabrication, and performance of resistance-based position sensors that are laser-machined from superelastic SMA tubing. Combining simple material models and rapid prototyping, we can develop sensors of appropriate stiffness and sensitivity with simple modifications in sensor geometry. The sensors exhibit excellent linearity over the operating range and are designed to be easily integrated onto an active catheter substrate.

19.
Semin Thorac Cardiovasc Surg ; 20(4): 333-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19251174

RESUMEN

Cardiovascular imaging technology is continuously evolving and provides an increasing array of tests to evaluate cardiovascular morphology and function. A basic understanding of imaging technology is helpful to select the best modality to answer a specific clinical question. This article provides a brief overview of recent technical developments in computed tomography (CT), magnetic resonance (MR), and echocardiography, which have increased our diagnostic understanding and may modulate treatment planning of patients with cardiovascular diseases: electrocardiographically (ECG)-gated CT, 4D-flow magnetic resonance imaging (MRI), and three-dimensional (3D) echocardiography.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Ecocardiografía/tendencias , Imagen por Resonancia Magnética/tendencias , Tomografía Computarizada por Rayos X/tendencias , Medios de Contraste , Electrocardiografía , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Dosis de Radiación
20.
Semin Thorac Cardiovasc Surg ; 20(4): 365-73, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19251178

RESUMEN

Valve-sparing aortic root repair (V-SARR) using the David reimplantation method is an increasingly popular alternative to composite valve graft aortic root replacement in patients with aortic root aneurysms or dissections who wish to avoid anticoagulation. Computed tomography (CT) with retrospective electrocardiograph (ECG)-gating has become routine before and following V-SARR at Stanford. CT allows accurate measurement of aortic dimensions and provides unprecedented three-dimensional (3D) images of the sinuses, the aortic valve cusps, and coronary arteries in patients with the Marfan syndrome (MFS), with a bicuspid aortic valve (BAV), or other aortic diseases. This helps the surgeon to conceptualize the size of the aortic grafts required and how much reduction is necessary proximally (aortic annulus) and distally. These maneuvers are used to reduce the aortic annular diameter (when necessary) and replace the sinuses and ascending aorta (T. David-V, Stanford modification V-SARR). Postoperative ECG-gated CT confirms the reconstructed geometry and reliably detects coronary or other anastomotic problems.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/cirugía , Velocidad del Flujo Sanguíneo , Implantación de Prótesis Vascular/métodos , Electrocardiografía , Humanos , Imagenología Tridimensional , Interpretación de Imagen Radiográfica Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA