Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Molecules ; 28(23)2023 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-38067644

RESUMEN

Contaminants of Emerging Concern (CECs), a new category of contaminants currently in the limelight, are a major issue of global concern. The pervasive nature of CECs and their harmful effects, such as cancer, reproductive disorders, neurotoxicity, etc., make the situation alarming. The perilous nature of CECs lies in the fact that even very small concentrations of CECs can cause great impacts on living beings. They also have a nature of bioaccumulation. Thus, there is a great need to have efficient sensors for the detection of CECs to ensure a safe living environment. Electrochemical sensors are an efficient platform for CEC detection as they are highly selective, sensitive, stable, reproducible, and prompt, and can detect very low concentrations of the analyte. Major classes of CECs are pharmaceuticals, illicit drugs, personal care products, endocrine disruptors, newly registered pesticides, and disinfection by-products. This review focusses on CECs, including their sources and pathways, health effects caused by them, and electrochemical sensors as reported in the literature under each category for the detection of major CECs.


Asunto(s)
Plaguicidas , Contaminantes Químicos del Agua , Contaminantes Químicos del Agua/análisis , Plaguicidas/análisis , Monitoreo del Ambiente
2.
Materials (Basel) ; 16(22)2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-38004995

RESUMEN

Super-sensitive malathion detection was achieved using a nonenzymatic electrochemical sensor based on a CuO/ZnO-modified glassy carbon electrode (GCE). Due to the high affinity between the Cu element and the sulfur groups in malathion, the developed CuO-ZnO/GCE sensor may bond malathion with ease, inhibiting the redox signal of the Cu element when malathion is present. In addition to significantly increasing the ability of electron transfer, the addition of 3D-flower-like ZnO enhances active sites of the sensor interface for the high affinity of malathion, giving the CuO-ZnO/GCE composite an exceptional level of sensitivity and selectivity. This enzyme-free CuO-ZnO/GCE malathion sensor demonstrates outstanding stability and excellent detection performance under optimal operating conditions with a wide linear range of malathion from 0 to 200 nM and a low detection limit of 1.367 nM. A promising alternative technique for organophosphorus pesticide (OP) determination is offered by the analytical performance of the proposed sensor, and this method can be quickly and sensitively applied to samples that have been contaminated with these pesticides.

3.
Nat Microbiol ; 3(5): 622-631, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29662128

RESUMEN

Insulin resistance is a risk factor for obesity and diabetes and predisposes individuals to Staphylococcus aureus colonization; however, the contribution of S. aureus to insulin resistance remains unclear. Here, we show that S. aureus infection causes impaired glucose tolerance via secretion of an insulin-binding protein extracellular domain of LtaS, eLtaS, which blocks insulin-mediated glucose uptake. Notably, eLtaS transgenic mice (eLtaS trans ) exhibited a metabolic syndrome similar to that observed in patients, including increased food and water consumption, impaired glucose tolerance and decreased hepatic glycogen synthesis. Furthermore, transgenic mice showed significant metabolic differences compared to their wild-type counterparts, particularly for the early insulin resistance marker α-hydroxybutyrate. We subsequently developed a full human monoclonal antibody against eLtaS that blocked the interaction between eLtaS and insulin, which effectively restored glucose tolerance in eLtaS trans and S. aureus-challenged mice. Thus, our results reveal a mechanism for S. aureus-induced insulin resistance.


Asunto(s)
Proteínas Bacterianas/química , Proteínas Bacterianas/genética , Resistencia a la Insulina , Insulina/metabolismo , Infecciones Estafilocócicas/complicaciones , Staphylococcus aureus/patogenicidad , Animales , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/farmacología , Proteínas Bacterianas/metabolismo , Sitios de Unión , Línea Celular , Femenino , Células Hep G2 , Humanos , Hidroxibutiratos/metabolismo , Síndrome Metabólico/tratamiento farmacológico , Síndrome Metabólico/genética , Síndrome Metabólico/metabolismo , Ratones , Ratones Transgénicos , Ratas , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/metabolismo , Staphylococcus aureus/metabolismo
4.
Eur J Obstet Gynecol Reprod Biol ; 214: 150-155, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28535400

RESUMEN

OBJECTIVES: This study was designed to compare the Cervista high risk (HR) human papillomavirus (HPV) test with Luminex XMAP technology for the detection of the relationship between HPV infection and cervical intraepithelial neoplasia. METHODS: In total, 3280 patients in a cervical specialty clinic were divided into two groups for either Cervista (1855 patients) or Luminex (1425 patients). Subsequent colposcopy examinations were performed in 1270 women with cytologic results showing ASCUS or higher level lesions. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were evaluated. RESULTS: The positive rates of the Cervista and Luminex groups were 61.48% and 67.43%, respectively, and occurrence in those 30-40 years old was most common. The typing of HPV showed that A9 positive cases were the most prevalent genotype (33.53%), followed by A5/A6 (16.44%) and A7 (11.37%) in the Cervista group, and HPV-16 was the most prevalent genotype (25.81%), followed by HPV-18 (18.6%) and HPV-31 (8.6%) in the Luminex group. Moreover, the overall concordance rate was 96.26% (95% confidence interval, 93.51-99.00%) in the 187 women with cytologic results of ASCUS or higher. There were no significant differences in the positive rates of HPV between the Cervista and Luminex groups, and both had a high sensitivity and NPV. CONCLUSIONS: The results showed a high good concordance between the two methods in diagnostic accuracy. Among the patients in the cervical specialty clinic, both the A9 group of HPV and HPV-16 showed the highest positive rate. Cervista and Luminex shared similar a clinical value in the detection of CIN2 or higher.


Asunto(s)
Sondas de ADN de HPV , Juego de Reactivos para Diagnóstico , Displasia del Cuello del Útero/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico , Adolescente , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Neoplasias del Cuello Uterino/virología , Adulto Joven , Displasia del Cuello del Útero/virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA