Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Small ; : e2400939, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38618653

RESUMEN

Heterodimers of metal nanocrystals (NCs) with tailored elemental distribution have emerged as promising candidates in the field of electrocatalysis, owing to their unique structures featuring heterogeneous interfaces with distinct components. Despite this, the rational synthesis of heterodimer NCs with similar elemental composition remains a formidable challenge, and their impact on electrocatalysis has remained largely elusive. In this study, Pd@Bi-PdBi heterodimer NCs are synthesized through an underpotential deposition (UPD)-directed growth pathway. In this pathway, the UPD of Bi promotes a Volmer-Weber growth mode, allowing for judicious modulation of core-satellite to heterodimer structures through careful control of supersaturation and growth kinetics. Significantly, the heterodimer NCs are employed in the electrocatalytic process of ethylene glycol (EG) with high activity and selectivity. Compared with pristine Pd octahedra and common PdBi alloy NC, the unique heterodimer structure of the Pd@Bi-PdBi heterodimer NCs endows them with the highest electrocatalytic performance of EG and the best selectivity (≈93%) in oxidizing EG to glycolic acid (GA). Taken together, this work not only heralds a new strategy for UPD-directed synthesis of bimetallic NCs, but also provides a new design paradigm for steering the selectivity of electrocatalysts.

2.
BMC Musculoskelet Disord ; 24(1): 881, 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37953269

RESUMEN

PURPOSE: This study was to investigate the feasibility and treatment effect of using modified Kirschner wire (K-wire) percutaneous rotation prying reduction combined with Elastic Stable Intramedullary Nailing (ESIN) in children with Judet IV radial neck fracture. METHODS: A retrospective analysis was conducted on 47 children with Judet IV radial neck fracture who underwent treatment with modified K-wire percutaneous rotation prying reduction combined with ESIN from April 2019 to November 2022, including 25 males and 22 females, with an average age of 8.79 years old (ranging from 5 to 14). The study recorded the surgical time, fluoroscopy time, reduction time, and reduction quality evaluated according to the Metaizeau radiological standard. During the last follow-up, the flexion-extension and forearm rotation function of the affected and healthy sides were recorded, and the Mayo Elbow Performance index was used to evaluate the elbow joint function. RESULTS: The average duration of the operation was 25.51 min (ranging from 14 to 43 min), with a mode of 2 reset times (ranging from 1 to 5) and 8 fluoroscopic times (ranging from 4 to 15). Based on the Metaizeau radiological standard for assessing reduction quality, 45 cases were deemed excellent, while 2 cases were considered good. Following 3-4 weeks of postoperative long-arm cast immobilization, exercises were performed to promote elbow joint and forearm rotation. The ESIN was removed after satisfactory fracture healing around 4 months postoperatively. The average follow-up period was 26.79 months (ranging from 5 to 48). At the final follow-up, the range of motion for the affected limb in flexion, extension, pronation, and supination was (140.23 ± 4.80)°, (4.43 ± 3.98)°, (84.09 ± 4.97)°, and (83.83 ± 4.55)°, respectively. There was no statistically significant difference compared to the healthy side, which had a range of motion of (141.36 ± 3.27)°, (5.28 ± 2.25)°, (85.66 ± 3.20)°, and (84.98 ± 2.57)° (P > 0.05). According to the Mayo Elbow Performance index, 44 cases were rated as excellent and 1 case was considered good. CONCLUSION: The modified K-wire percutaneous rotation prying reduction combined with ESIN is an effective treatment for severe radial neck fractures in children. This technique offers several advantages, including the ability to easily "capture" significantly displaced radial heads, achieve rapid and accurate reduction, and reduce radiation exposure.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas Radiales de Cabeza y Cuello , Fracturas del Radio , Masculino , Femenino , Humanos , Niño , Hilos Ortopédicos , Fijación Intramedular de Fracturas/métodos , Clavos Ortopédicos , Estudios Retrospectivos , Resultado del Tratamiento , Fijación Interna de Fracturas/métodos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Extremidad Superior , Rango del Movimiento Articular
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(10): 1214-1219, 2023 Oct 15.
Artículo en Chino | MEDLINE | ID: mdl-37848315

RESUMEN

Objective: To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents. Methods: The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient's upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint. Results: The operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones ( P<0.05). Except for the extension range of motion of the healthy elbow joint ( P<0.05), there was no significant difference in other indicators between the two sides ( P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%. Conclusion: Computer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.


Asunto(s)
Articulación del Codo , Fracturas del Húmero , Deformidades Adquiridas de la Articulación , Deformidades Congénitas de las Extremidades , Masculino , Femenino , Humanos , Adolescente , Preescolar , Niño , Codo , Fracturas del Húmero/cirugía , Estudios Retrospectivos , Deformidades Adquiridas de la Articulación/etiología , Deformidades Adquiridas de la Articulación/cirugía , Articulación del Codo/cirugía , Osteotomía/métodos , Cabeza Humeral , Rango del Movimiento Articular , Computadores , Resultado del Tratamiento
4.
J Orthop Surg Res ; 18(1): 595, 2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37568239

RESUMEN

PURPOSE: This study aims to evaluate the feasibility of using ultrasound-guided Kirschner wire or elastic intramedullary nail for fixation in the treatment of acute Monteggia fracture in children. METHODS: A retrospective analysis was conducted on 31 cases of acute Monteggia fracture in children treated with ultrasound-guided Kirschner wire or elastic intramedullary nail fixation between April 2020 and December 2022, including 14 cases of Kirschner wire fixation and 17 cases of elastic intramedullary nail fixation. During the operation, soft tissue compression and nerve and vascular injuries were explored, fracture reduction was performed under ultrasound guidance, and operation time was recorded. After the operation, X-ray examination was conducted to assess the quality of fracture reduction. At the last follow-up, the flexion, extension, pronation, and supination angles of both affected and unaffected elbow joints were measured, and the Mayo score was used to evaluate elbow joint function. RESULTS: The average duration of surgery was 50.16 ± 19.21 min (ranging from 20 to 100 min). Based on the evaluation criteria for assessing reduction quality, 28 cases were deemed excellent, while 3 cases were considered good. After immobilization with long-arm cast for 4-6 weeks postoperatively, elbow and forearm rotation exercises were performed. Kirschner wires were removed after an average of 6.64 ± 0.93 weeks (ranging from 6 to 9 weeks) postoperatively, and elastic intramedullary nails were removed after an average of 5.12 ± 1.54 months (ranging from 4 to 10 months) postoperatively. The average follow-up time was 19.13 ± 11.22 months (ranging from 4 to 36 months). During the final follow-up, the affected limb's range of motion in flexion, extension, pronation, and supination was (141.16 ± 4.24)°, (4.61 ± 2.81)°, (84.52 ± 3.74)°, and (84.23 ± 3.69)°, respectively. There was no notable variance when compared to the healthy limb, which had a range of motion of (141.81 ± 2.99)°, (4.81 ± 2.50)°, (85.61 ± 3.12)°, and (85.03 ± 2.73)° (P > 0.05). The Mayo Elbow Performance index classified 29 cases as excellent and 2 cases as good. CONCLUSION: Ultrasound-guided Kirschner wire or elastic intramedullary nail fixation can be used for the treatment of acute Monteggia fracture in children, which can explore the surrounding nerves, blood vessels, and soft tissue compression, reduce the difficulty of reduction, and cause minimal trauma. It can greatly reduce the risk of radiation exposure and complications such as vascular and nerve injury during the operation.


Asunto(s)
Articulación del Codo , Fractura de Monteggia , Humanos , Niño , Fractura de Monteggia/diagnóstico por imagen , Fractura de Monteggia/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Hilos Ortopédicos , Articulación del Codo/cirugía , Fijación Interna de Fracturas , Rango del Movimiento Articular
5.
Front Oncol ; 11: 737760, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34568073

RESUMEN

BACKGROUND: The prognostic and clinicopathological value of Ki-67 in melanoma is controversial. The purpose of this meta-analysis was to determine the prognostic role of Ki-67 in melanoma patients. MATERIALS AND METHODS: The PubMed, Cochrane Library, Web of Science, and Embase databases were searched systematically up to April 9, 2021. We calculated the pooled hazard ratios (HRs) and 95% confidence intervals (CIs) to determine the relationship between Ki-67 overexpression and survival outcomes. We also calculated the combined odds ratios (ORs) and 95% CIs to determine the relationship between Ki-67 expression levels and clinicopathologic parameters. All data were statistically analyzed by Stata 11.0. RESULTS: A total of 10 studies involving 929 patients were included in our meta-analysis. The pooled HR showed that Ki-67 overexpression was connected with poor overall survival rates (HR=2.92, 95% CI=2.17-3.91, p<0.000). However, there was no correlation between Ki-67 overexpression and the PFS (HR=0.999, 95% CI =0.958-1.041, P =0.958; I2 = 21.80%, P =0.258) or RFS (HR=1.14, 95% CI = 0.42-3.11, P =0.993; I2 = 85.00%, P =0.01) rates. Ki-67 expression levels were associated with tumor thickness, but not sex, location, ulceration or vascular invasion. CONCLUSION: Ki-67 is a useful poor prognostic indicator for melanoma patients.

6.
Clin Cancer Res ; 27(18): 5028-5037, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-34210683

RESUMEN

PURPOSE: M-protein is a well-established biomarker used for multiple myeloma monitoring. Current improvements in multiple myeloma treatment created the need to monitor minimal residual disease (MRD) with high sensitivity. Measuring residual levels of M-protein in serum by MS was established as a sensitive assay for disease monitoring. In this study we evaluated the performance of EasyM-a noninvasive, sensitive, MS-based assay for M-protein monitoring. EXPERIMENTAL DESIGN: Twenty-six patients enrolled in MCRN-001 clinical trial of two high-dose alkylating agents as conditioning followed by lenalidomide maintenance were selected for the study. All selected patients achieved complete responses (CR) during treatment, whereas five experienced progressive disease on study. The M-protein of each patient was first sequenced from the diagnostic serum using our de novo protein sequencing platform. The patient-specific M-protein peptides were then measured by targeted MS assay to monitor the response to treatment. RESULTS: The M-protein doubling over 6 months measured by EasyM could predict the relapse in 4 of 5 relapsed patients 2 to 11 months earlier than conventional testing. In 21 disease-free patients, the M-protein was still detectable by EasyM despite normal FLC and MRD negativity. Importantly, of 72 MRD negative samples with CR status, 62 were positive by EasyM. The best sensitivity achieved by EasyM, detecting 0.58 mg/L of M-protein, was 1,000- and 200-fold higher compared with serum protein electrophoresis and immunofixation electrophoresis, respectively. CONCLUSIONS: EasyM was demonstrated to be a noninvasive, sensitive assay with superior performance compared with other assays, making it ideal for multiple myeloma monitoring and relapse prediction.


Asunto(s)
Mieloma Múltiple , Humanos , Lenalidomida , Espectrometría de Masas , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/tratamiento farmacológico , Recurrencia Local de Neoplasia/tratamiento farmacológico , Neoplasia Residual
7.
J Proteome Res ; 20(8): 4176-4185, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34242034

RESUMEN

The amino acid sequence of the M-protein for multiple myeloma is unique compared to the polyclonal antibodies in patients' blood. This uniqueness is exploited to develop an ultrasensitive M-protein detection method utilizing mass spectrometry (MS). The method involves the de novo amino acid sequencing of the full-length M-protein, and a targeted MS/MS assay to detect and quantify the unique M-protein sequence in serum samples. Healthy control serum spiked with NISTmAb and serial samples from an MM patient were used to demonstrate the ability of the platform to sequence and monitor a target M-protein. The de novo NISTmAb protein sequence obtained matched the published sequence, confirming the ability of the platform to accurately sequence a target M-protein in serum. NISTmAb was quantified down to 0.0002 g/dL in serum, a level hundreds of times more sensitive than conventional blood-based tests such as SPEP and IFE. The M-protein in the patient sample could be quantified throughout complete remission, demonstrating the utility of the assay to track M-protein considerably beyond the sensitivities of current blood-based tests. Notably, the assay detected a 2-fold rise in M-protein levels 10 months before any changes were detected by conventional IFE. The MS-based assay is highly sensitive, noninvasive, and requires only a small amount of serum, less than 100 µL. Sequencing data is deposited into PRIDE with identifier PXD022784, and quantification data can be found in Panorama Public with identifier PXD022980.


Asunto(s)
Mieloma Múltiple , Secuencia de Aminoácidos , Humanos , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/genética , Espectrometría de Masas en Tándem
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 261: 120002, 2021 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-34090095

RESUMEN

The utilization and residue of pesticides exist multifaceted non-restrictive effects on food safety and ecological protection. Exploitation of rapid and sensitive pesticide detection technology is imperative and will be helpful to better control the detriment of pesticides. Here, a novel flexible film has been prepared based on organic-inorganic composite materials (coumarin-3-carboxylic acid and GdF3:Sm3+), which exhibits good optical performance and can well realize the timely and maneuverable detection for different pesticides. The spectra and luminescence properties of each composition in the composite have been analyzed systematically, and the coordinated fluorescence emission of Sm3+ and coumarin-3-carboxylic acid is revealed at an excitation wavelength of 373 nm. Besides, the energy transfer mechanism is also researched by both experiment and theoretical calculation. The actual detection of different pesticides reveals differential fluorescence influence degree. Meanwhile, the flexible film still possesses sensitive recognition in the presence of micro concentration of pesticides. Results indicate that the flexible film with good optical performance can produce visual detection ability and provide a promising strategy for wider detection applications.


Asunto(s)
Plaguicidas , Cumarinas , Luminiscencia , Plaguicidas/análisis , Espectrometría de Fluorescencia
9.
Psychogeriatrics ; 21(1): 32-41, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33179396

RESUMEN

BACKGROUND: The Functional Assessment Of Chronic Illness Therapy-Spiritual Well-Being-Expanded (FACIT-Sp-Ex) scale can simultaneously evaluate the quality of life and spiritual health level of patients with chronic orthopaedic diseases. We performed the FACIT-Sp-Ex scale in Chinese, and tested its reliability and validity in patients with chronic orthopaedic diseases. METHODS: There were 249 patients with chronic orthopaedic diseases who were selected for the questionnaire survey. AMOS 23.0 and SPSS 25.0 were used for statistical analysis to calculate the reliability and validity of the Chinese version of the scale. RESULTS: The Chinese version of FACIT-Sp-Ex scale showed that root mean square error of approximation (RMSEA) was 0.06. Cronbach's alpha coefficient was 0.83, the subscale was 0.72 ~ 0.82. The meaning, peace, relational subscales and total scale of the FACIT-Sp-Ex were negatively correlated with hospital anxiety and depression scale (HADS) and positively correlated with health-related quality of life (HRQOL). All four subdomains were inversely associated with HADS anxiety symptoms, the peace and relational subscales were inversely associated with HADS depressive symptoms. Elderly female patients score higher than male patients in faith subscale. The highest-scoring disease in FACIT-Sp-Ex faith scale was osteoarthritis, which in FACIT-Sp-Ex total scale are piriformis syndrome and osteoarthritis. CONCLUSION: The Chinese version of FACIT-Sp-Ex scale has good reliability and validity, which can be used as an evaluation tool for the spiritual status and quality of life of Chinese elderly chronic orthopaedic patients.


Asunto(s)
Enfermedad Crónica , Enfermedades Musculoesqueléticas , Neoplasias , Espiritualidad , Anciano , Femenino , Humanos , Masculino , Enfermedades Musculoesqueléticas/complicaciones , Enfermedades Musculoesqueléticas/psicología , Psicometría , Calidad de Vida , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
10.
RSC Adv ; 9(36): 20778-20785, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35515559

RESUMEN

Herein, uniform Ag nanocube@NaYF4:Yb3+,Tm3+ multifunctional nanocomposites were constructed by a facile synthetic strategy. Following the successful synthesis of Ag nanocubes, cubic phase NaYF4:Yb3+,Tm3+ upconversion luminescent nanocrystals were modified on the surface of the Ag nanocubes, enhanced the mutual assistance of energy and versatility of the materials. Upon irradiation with a near-infrared laser, the nanocomposites exhibited excellent upconversion fluorescence and good photothermal conversion capability. Furthermore, the potential biological applications and biosafety of the Ag@NaYF4:Yb3+,Tm3+ nanocomposites were also demonstrated; the obtained nanocomposites could achieve a good bactericidal performance and photothermal treatment of cancer cells, and they could be potentially applied in the biomedical field as a promising agent. Furthermore, this method provides a facile approach for synthesizing a multifunctional nanocomposite with different properties.

11.
Int J Mol Sci ; 15(7): 12714-30, 2014 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-25046745

RESUMEN

This paper presents studies on the characteristics of gas molecular mean freepath in nanopores by molecular dynamics simulation. Our study results indicate that themean free path of all molecules in nanopores depend on both the radius of the nanoporeand the gas-solid interaction strength. Besides mean free path of all molecules in thenanopore, this paper highlights the gas molecular mean free path at different positions ofthe nanopore and the anisotropy of the gas molecular mean free path at nanopores. Themolecular mean free path varies with the molecule's distance from the center of thenanopore. The least value of the mean free path occurs at the wall surface of the nanopore.The present paper found that the gas molecular mean free path is anisotropic when gas isconfined in nanopores. The radial gas molecular mean free path is much smaller than themean free path including all molecular collisions occuring in three directions. Our studyresults also indicate that when gas is confined in nanopores the gas molecule number densitydoes not affect the gas molecular mean free path in the same way as it does for the gas inunbounded space. These study results may bring new insights into understanding the gasflow's characteristic at nanoscale.


Asunto(s)
Gases/química , Simulación de Dinámica Molecular , Nanoporos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA