1.
Eur Radiol ; 33(3): 1629-1640, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36323984

RESUMEN

OBJECTIVES: To compare the image quality and hepatic metastasis detection of low-dose deep learning image reconstruction (DLIR) with full-dose filtered back projection (FBP)/iterative reconstruction (IR). METHODS: A contrast-detail phantom consisting of low-contrast objects was scanned at five CT dose index levels (10, 6, 3, 2, and 1 mGy). A total of 154 participants with 305 hepatic lesions who underwent abdominal CT were enrolled in a prospective non-inferiority trial with a three-arm design based on phantom results. Data sets with full dosage (13.6 mGy) and low dosages (9.5, 6.8, or 4.1 mGy) were acquired from two consecutive portal venous acquisitions, respectively. All images were reconstructed with FBP (reference), IR (control), and DLIR (test). Eleven readers evaluated phantom data sets for object detectability using a two-alternative forced-choice approach. Non-inferiority analyses were performed to interpret the differences in image quality and metastasis detection of low-dose DLIR relative to full-dose FBP/IR. RESULTS: The phantom experiment showed the dose reduction potential from DLIR was up to 57% based on the reference FBP dose index. Radiation decreases of 30% and 50% resulted in non-inferior image quality and hepatic metastasis detection with DLIR compared to full-dose FBP/IR. Radiation reduction of 70% by DLIR performed inferiorly in detecting small metastases (< 1 cm) compared to full-dose FBP (difference: -0.112; 95% confidence interval [CI]: -0.178 to 0.047) and full-dose IR (difference: -0.123; 95% CI: -0.182 to 0.053) (p < 0.001). CONCLUSION: DLIR enables a 50% dose reduction for detecting low-contrast hepatic metastases while maintaining comparable image quality to full-dose FBP and IR. KEY POINTS: • Non-inferiority study showed that deep learning image reconstruction (DLIR) can reduce the dose to oncological patients with low-contrast lesions without compromising the diagnostic information. • Radiation dose levels for DLIR can be reduced to 50% of full-dose FBP and IR for detecting low-contrast hepatic metastases, while maintaining comparable image quality. • The reduction of radiation by 70% by DLIR is clinically acceptable but insufficient for detecting small low-contrast hepatic metastases (< 1 cm).


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Humanos , Algoritmos , Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos
2.
Eur J Radiol ; 141: 109825, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34144309

RESUMEN

OBJECTIVE: To assess the diagnostic performance and reader confidence in determining the resectability of pancreatic cancer at computed tomography (CT) using a new deep learning image reconstruction (DLIR) algorithm. METHODS: A retrospective review was conduct of on forty-seven patients with pathologically confirmed pancreatic cancers who underwent baseline multiphasic contrast-enhanced CT scan. Image data sets were reconstructed using filtered back projection (FBP), hybrid model-based adaptive statistical iterative reconstruction (ASiR-V) 60 %, and DLIR "TrueFidelity" at low(L), medium(M), and high strength levels(H). Four board-certified abdominal radiologists reviewed the CT images and classified cancers as resectable, borderline resectable, or unresectable. Diagnostic performance and reader confidence for categorizing the resectability of pancreatic cancer were evaluated based on the reference standards, and the interreader agreement was assessed using Fleiss k statistics. RESULTS: For prediction of margin-negative resections(ie, R0), the average area under the receiver operating characteristic curve was significantly higher with DLIR-H (0.91; 95 % confidence interval [CI]: 0.79, 0.98) than FBP (0.75; 95 % CI:0.60, 0.86) and ASiR-V (0.81; 95 % CI:0.67, 0.91) (p = 0.030 and 0.023 respectively). Reader confidence scores were significantly better using DLIR compared to FBP and ASiR-V 60 % and increased linearly with the increase of DLIR strength level (all p < 0.001). Among the image reconstructions, DLIR-H showed the highest interreader agreement in the resectability classification and lowest subject variability in the reader confidence. CONCLUSIONS: The DLIR-H algorithm may improve the diagnostic performance and reader confidence in the CT assignment of the local resectability of pancreatic cancer while reducing the interreader variability.


Asunto(s)
Aprendizaje Profundo , Neoplasias Pancreáticas , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
3.
Phys Med Biol ; 60(14): 5699-710, 2015 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-26147244

RESUMEN

The purpose of this study was two-fold: (a) to measure the dose to the brain using clinical protocols at our institution, and (b) to develop a scanner-independent dosimetry method to estimate brain dose. Radiation dose was measured with a pediatric anthropomorphic phantom and MOSFET detectors. Six current neuroradiology protocols were used: brain, sinuses, facial bones, orbits, temporal bones, and craniofacial areas. Two different CT vendor scanners (scanner A and B) were used. Partial volume correction factors (PVCFs) were determined for the brain to account for differences between point doses measured by the MOSFETs and average organ dose. The CTDIvol and DLP for each protocol were recorded. The dose to the brain (mGy) for scanners A and B was 10.7 and 10.0 for the brain protocol, 7.8 and 3.2 for the sinus, 10.2 and 8.6 for the facial bones, 7.4 and 4.7 for the orbits and 1.6 and 1.9 for the temporal bones, respectively. On scanner A, the craniofacial protocol included a standard and high dose option; the dose measured for these exams was 3.9 and 16.9 mGy, respectively. There was only one craniofacial protocol on scanner B; the brain dose measured on this exam was 4.8 mGy. A linear correlation was found between DLP and brain dose with the conversion factors: 0.049 (R(2) = 0.87), 0.046 (R(2) = 0.89) for scanner A and B, and 0.048 (R(2) = 0.89) for both scanners. The range of dose observed was between 1.8 and 16.9 mGy per scan. This suggests that brain dose estimates may be made from DLP.


Asunto(s)
Encéfalo/diagnóstico por imagen , Neurorradiografía/métodos , Fantasmas de Imagen , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/métodos , Encéfalo/efectos de la radiación , Preescolar , Simulación por Computador , Estudios de Factibilidad , Humanos , Dosis de Radiación
4.
AJR Am J Roentgenol ; 204(5): W579-85, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25905965

RESUMEN

OBJECTIVE: The purpose of this study is to measure the organ doses and effective dose (ED) for parathyroid 4D CT and scintigraphy and to estimate the lifetime attributable risk of cancer incidence associated with imaging. MATERIALS AND METHODS: Organ radiation doses for 4D CT and scintigraphy were measured on the basis of imaging with our institution's protocols. An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was scanned to measure CT organ dose. Organ doses from the radionuclide were based on International Commission for Radiological Protection report 80. ED was calculated for 4D CT and scintigraphy and was used to estimate the lifetime attributable risk of cancer incidence for patients differing in age and sex with the approach established by the Biologic Effects of Ionizing Radiation VII report. A 55-year-old woman was selected as the standard patient according to the demographics of patients with primary hyperparathyroidism. RESULTS: Organs receiving the highest radiation dose from 4D CT were the thyroid (150.6 mGy) and salivary glands (137.8 mGy). For scintigraphy, the highest organ doses were to the colon (41.5 mGy), gallbladder (39.8 mGy), and kidneys (32.3 mGy). The ED was 28 mSv for 4D CT, compared with 12 mSv for scintigraphy. In the exposed standard patient, the lifetime attributable risk for cancer incidence was 193 cancers/100,000 patients for 4D CT and 68 cancers/100,000 patients for scintigraphy. Given a baseline lifetime incidence of cancer of 46,300 cancers/100,000 patients, imaging results in an increase in lifetime incidence of cancer over baseline of 0.52% for 4D CT and 0.19% for scintigraphy. CONCLUSION: The ED of 4D CT is more than double that of scintigraphy, but both studies cause negligible increases in lifetime risk of cancer. Clinicians should not allow concern for radiation-induced cancer to influence decisions regarding workup in older patients.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Inducidas por Radiación/etiología , Enfermedades de las Paratiroides/diagnóstico por imagen , Dosis de Radiación , Femenino , Humanos , Incidencia , Masculino , Neoplasias Inducidas por Radiación/epidemiología , Fantasmas de Imagen , Cintigrafía , Medición de Riesgo , Factores de Riesgo
5.
AJR Am J Roentgenol ; 201(5): W730-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24063388

RESUMEN

OBJECTIVE: The purpose of this study was to measure the organ doses and estimate the effective dose for the standard brain perfusion CT protocol and erroneous protocols. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. Protocol 1 used a standard brain perfusion protocol with 80 kVp and fixed tube current of 200 mA. Protocol 2 used 120 kVp and fixed tube current of 200 mA. Protocol 3 used 120 kVp with automatic tube current modulation (noise index, 2.4; minimum, 100 mA; maximum, 520 mA). RESULTS: Compared with protocol 1, the effective dose was 2.8 times higher with protocol 2 and 7.8 times higher with protocol 3. For all protocols, the peak dose was highest in the skin, followed by the brain and calvarial marrow. Compared with protocol 1, the peak skin dose was 2.6 times higher with protocol 2 and 6.7 times higher with protocol 3. The peak skin dose for protocol 3 exceeded 3 Gy. The ocular lens received significant scatter radiation: 177 mGy for protocol 2 and 435 mGy for protocol 3, which were 4.6 and 11.3 times the dose for protocol 1, respectively. CONCLUSION: Compared with the standard protocol, erroneous protocols of increasing the tube potential from 80 kVp to 120 kVp will lead to a three- to fivefold increase in organ doses, and concurrent use of high peak kilovoltage with incorrectly programmed tube current modulation can increase dose to organs by 7- to 11-fold. Tube current modulation with a low noise index can lead to doses to the skin and ocular lens that are close to thresholds for tissue reactions.


Asunto(s)
Encéfalo/diagnóstico por imagen , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/instrumentación
6.
J Endourol ; 27(10): 1187-91, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23734577

RESUMEN

OBJECTIVE: To compare the effective doses (EDs) associated with imaging modalities for follow-up of patients with urolithiasis, including stone protocol non-contrast computed tomography (NCCT), kidney, ureter, and bladder radiograph (KUB), intravenous urogram (IVU), and digital tomosynthesis (DT). METHODS: A validated Monte-Carlo simulation-based software PCXMC 2.0 (STUK) designed for estimation of patient dose from medical X-ray exposures was used to determine the ED for KUB, IVU (KUB scout plus three tomographic images), and DT (two scouts and one tomographic sweep). Simulations were performed using a two-dimensional stationary field onto the corresponding body area of the built-in digital phantom, with actual kVp, mAs, and geometrical parameters of the protocols. The ED for NCCT was determined using an anthropomorphic male phantom that was placed prone on a 64-slice GE Healthcare volume computed tomography (VCT) scanner. High-sensitivity metal oxide semiconductor field effect transistors dosimeters were placed at 20 organ locations and used to measure organ radiation doses. RESULTS: The ED for a stone protocol NCCT was 3.04±0.34 mSv. The ED for a KUB was 0.63 and 1.1 mSv for the additional tomographic film. The total ED for IVU was 3.93 mSv. The ED for DT performed with two scouts and one sweep (14.2°) was 0.83 mSv. CONCLUSIONS: Among the different imaging modalities for follow-up of patients with urolithiasis, DT was associated with the least radiation exposure (0.83 mSv). This ED corresponds to a fifth of NCCT or IVU studies. Further studies are needed to demonstrate the sensitivity and specificity of DT for the follow-up of nephrolithiasis patients.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos , Urolitiasis/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Fantasmas de Imagen
7.
J Urol ; 190(6): 2117-23, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23764073

RESUMEN

PURPOSE: Computerized tomography use increased exponentially in the last 3 decades, and it is commonly used to evaluate many urological conditions. Ionizing radiation exposure from medical imaging is linked to the risk of malignancy. We measured the organ and calculated effective doses of different studies to determine whether the dose-length product method is an accurate estimation of radiation exposure. MATERIALS AND METHODS: An anthropomorphic male phantom validated for human organ dosimetry measurements was used to determine radiation doses. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations to measure specific organ doses. For each study the phantom was scanned 3 times using our institutional protocols. Organ doses were measured and effective doses were calculated on dosimetry. Effective doses measured by a metal oxide semiconductor field effect transistor dosimeter were compared to calculated effective doses derived from the dose-length product. RESULTS: The mean±SD effective dose on dosimetry for stone protocol, chest and abdominopelvic computerized tomography, computerized tomography urogram and renal cell carcinoma protocol computerized tomography was 3.04±0.34, 4.34±0.27, 5.19±0.64, 9.73±0.71 and 11.42±0.24 mSv, respectively. The calculated effective dose for these studies Was 3.33, 2.92, 5.84, 9.64 and 10.06 mSv, respectively (p=0.8478). CONCLUSIONS: The effective dose varies considerable for different urological computerized tomography studies. Renal stone protocol computerized tomography shows the lowest dose, and computerized tomography urogram and the renal cell carcinoma protocol accumulate the highest effective doses. The calculated effective dose derived from the dose-length product is a reasonable estimate of patient radiation exposure.


Asunto(s)
Técnicas de Diagnóstico Urológico/normas , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/normas , Humanos , Masculino
8.
J Urol ; 189(6): 2142-6, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23261481

RESUMEN

PURPOSE: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults. MATERIALS AND METHODS: We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation doses. The nonobese and obese models have an approximate body mass index of 24 and 30 kg/m(2), respectively. Three runs of renal stone protocol computerized tomography were performed on each phantom under automatic tube current modulation. Organ specific absorbed doses were measured and effective doses were calculated. RESULTS: The bone marrow of each model received the highest dose and the skin received the second highest dose. The mean ± SD effective dose for the nonobese and obese models was 3.04 ± 0.34 and 10.22 ± 0.50 mSv, respectively (p <0.0001). CONCLUSIONS: The effective dose of stone protocol computerized tomography in obese patients is more than threefold higher than the dose in nonobese patients using automatic tube current modulation. The implication of this finding extends beyond the urological stone population and adds to our understanding of radiation exposure from medical imaging.


Asunto(s)
Obesidad/complicaciones , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Carga Corporal (Radioterapia) , Índice de Masa Corporal , Humanos , Masculino , Modelos Teóricos , Nefrolitiasis/diagnóstico por imagen , Monitoreo de Radiación/métodos , Recurrencia , Valores de Referencia , Tomografía Computarizada por Rayos X/métodos
9.
AJR Am J Roentgenol ; 199(1): W65-73, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22733933

RESUMEN

OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT. MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose. Noise was measured to evaluate image quality. Breast tissue location across the anterior aspect of the thorax was retrospectively assessed in 100 consecutive thoracic MDCT examinations. RESULTS: There was a 17-47% decrease (p = < 0.05) in anterior thoracic organ dose and a maximum 52% increase (p = < 0.05) in posterior thoracic organ dose using organ-based dose modulation compared with tube current modulation. Effective dose (SD) for tube current modulation and organ-based dose modulation were 5.25 ± 0.36 mSv and 4.42 ± 0.30 mSv, respectively. Radiochromic film analysis showed a 30% relative midline anterior-posterior gradient. There was no statistically significant difference in image noise. Adult female breast tissue was located within an average anterior angle of 155° (123-187°). CONCLUSION: Organ-based dose modulation CT using an anterior 120° arc can reduce the organ dose in the anterior aspect of the thorax with a compensatory organ dose increase posteriorly without impairment of image quality. Laterally located breast tissue will have higher organ doses than medially located breast tissue when using organ-based dose modulation. The benefit of this dose reduction must be clinically determined on the basis of the relationship of the irradiated organs to the location of the prescribed radial arc used in organ-based dose modulation.


Asunto(s)
Exposición a Riesgos Ambientales/análisis , Dosis de Radiación , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Mama , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica , Dosificación Radioterapéutica , Estudios Retrospectivos , Tórax , Adulto Joven
10.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528904

RESUMEN

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Asunto(s)
Dosis de Radiación , Protección Radiológica/instrumentación , Glándula Tiroides/efectos de la radiación , Tomografía Computarizada por Rayos X , Carga Corporal (Radioterapia) , Femenino , Humanos , Cuello , Fantasmas de Imagen , Radiometría , Programas Informáticos
11.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22358002

RESUMEN

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Asunto(s)
Cuello/diagnóstico por imagen , Tomografía Computarizada Espiral/métodos , Adulto , Humanos , Fantasmas de Imagen , Dosis de Radiación , Protección Radiológica , Interpretación de Imagen Radiográfica Asistida por Computador , Valores de Referencia
12.
AJR Am J Roentgenol ; 195(2): 433-8, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20651201

RESUMEN

OBJECTIVE: The purpose of this study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for routine CT of the brain. MATERIALS AND METHODS: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in the brain of a male anthropomorphic phantom scanned three times with a routine clinical brain CT protocol on four scanners from one manufacturer in four configurations and on one 64-MDCT scanner from another manufacturer. Absorbed organ doses were measured for skin, cranium, brain, lens of the eye, mandible, and thyroid. Effective dose was calculated on the basis of the dose-length product recorded on each scanner. RESULTS: Organ dose ranges were as follows: cranium, 2.57-3.47 cGy; brain, 2.34-3.78 cGy; lens, 2.51-5.03 cGy; mandible 0.17-0.48 cGy; and thyroid, 0.03-0.28 cGy. Statistically significant differences between scanners with respect to dose were recorded for brain and lens (p < 0.05). Absorbed doses were lowest on the single-detector scanner. In the comparison of MDCT scanners, the highest doses were found on the 4-MDCT scanner and the dual-source 64-MDCT scanner not capable of gantry tilt. Effective dose ranged from 1.22 to 1.86 mSv. CONCLUSION: According to the phantom data, patients are subject to different organ doses in the lens and brain depending on scanner assignment. At our institution with existing protocols, absorbed doses at brain CT are lowest with the single-detector CT scanner, followed by MDCT scanners capable of gantry tilt. On scanners without gantry tilt, CT of the brain should be performed with careful head positioning and shielding of the orbits. These precautions are especially true for patients who need repeated scanning and for pediatric patients.


Asunto(s)
Carga Corporal (Radioterapia) , Encéfalo/diagnóstico por imagen , Dosis de Radiación , Radiometría/estadística & datos numéricos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adulto , Niño , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
AJR Am J Roentgenol ; 193(4): 1141-7, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19770340

RESUMEN

OBJECTIVE: The objective of our study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for common body CT studies. MATERIALS AND METHODS: Twenty metal oxide semiconductor field effect transistor dosimeters were placed in a medium-sized anthropomorphic phantom of a man. Pulmonary embolism and chest, abdomen, and pelvis protocols were used to scan the phantom three times with GE Healthcare scanners in four configurations and one 64-MDCT Siemens Healthcare scanner. Organ doses were averaged, and effective doses were calculated with weighting factors. RESULTS: The mean effective doses for the pulmonary embolism protocol ranged from 9.9 to 18.5 mSv and for the chest, abdomen, and pelvis protocol from 6.7 to 18.5 mSv. For the pulmonary embolism protocol, the mean effective dose from the Siemens Healthcare 64-MDCT scanner was significantly lower than that from the 16- and 64-MDCT GE Healthcare scanners (p < 0.001). The mean effective dose from the GE 4-MDCT scanner was significantly lower than that for the GE 16-MDCT scanner (p < 0.001) but not the GE 64-MDCT scanner (p = 0.02). For the chest, abdomen, and pelvis protocol, all mean effective doses from the GE scanners were significantly different from one another (p < 0.001), the lowest mean effective dose being found with use of a single-detector CT scanner and the highest with a 4-MDCT scanner. For the chest, abdomen, and pelvis protocols, the difference between the mean effective doses from the GE Healthcare and Siemens Healthcare 64-MDCT scanners was not statistically significant (p = 0.89). CONCLUSION: According to phantom data, patients are subject to different radiation exposures for similar body CT protocols depending on scanner assignment. In general, doses are lowest with use of 64-MDCT scanners.


Asunto(s)
Carga Corporal (Radioterapia) , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Recuento Corporal Total/métodos , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Masculino , Fantasmas de Imagen , Efectividad Biológica Relativa
14.
AJR Am J Roentgenol ; 192(1): 244-53, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19098206

RESUMEN

OBJECTIVE: The purpose of this study was to assess whether radiation dose savings using a lower peak kilovoltage (kVp) setting, bismuth breast shields, and automatic tube current modulation could be achieved while preserving the image quality of MDCT scans obtained to assess for pulmonary embolus (PE). MATERIALS AND METHODS: CT angiography (CTA) examinations were performed to assess for the presence or absence of pulmonary artery emboli using a 64-MDCT scanner with automatic tube current modulation (noise level=10 HU), two kVp settings (120 and 140 kVp), and bismuth breast shields. Absorbed organ doses were measured using anthropomorphic phantoms and metal oxide semiconductor field effect transistor (MOSFET) detectors. Image quality was assessed quantitatively as well as qualitatively in various anatomic sites of the thorax. RESULTS: Using a lower kVp (120 vs 140 kVp) and automatic tube current modulation resulted in a dose savings of 27% to the breast and 47% to the lungs. The use of a lower kVp (120 kVp), automatic tube current modulation, and bismuth shields placed directly on the anterior chest wall reduced absorbed breast and lung doses by 55% and 45%, respectively. Qualitative assessment of the images showed no change in image quality of the lungs and mediastinum when using a lower kVp, bismuth shields, or both. CONCLUSION: The use of bismuth breast shields together with a lower kVp and automatic tube current modulation will reduce the absorbed radiation dose to the breast and lungs without degradation of image quality to the organs of the thorax for CTA detection of PE.


Asunto(s)
Carga Corporal (Radioterapia) , Embolia Pulmonar/diagnóstico por imagen , Protección Radiológica/instrumentación , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Dosis de Radiación , Efectividad Biológica Relativa
15.
EMBO J ; 27(14): 1932-43, 2008 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-18566586

RESUMEN

The target of rapamycin (TOR), as part of the rapamycin-sensitive TOR complex 1 (TORC1), regulates various aspects of protein synthesis. Whether TOR functions in this process as part of TORC2 remains to be elucidated. Here, we demonstrate that mTOR, SIN1 and rictor, components of mammalian (m)TORC2, are required for phosphorylation of Akt and conventional protein kinase C (PKC) at the turn motif (TM) site. This TORC2 function is growth factor independent and conserved from yeast to mammals. TM site phosphorylation facilitates carboxyl-terminal folding and stabilizes newly synthesized Akt and PKC by interacting with conserved basic residues in the kinase domain. Without TM site phosphorylation, Akt becomes protected by the molecular chaperone Hsp90 from ubiquitination-mediated proteasome degradation. Finally, we demonstrate that mTORC2 independently controls the Akt TM and HM sites in vivo and can directly phosphorylate both sites in vitro. Our studies uncover a novel function of the TOR pathway in regulating protein folding and stability, processes that are most likely linked to the functions of TOR in protein synthesis.


Asunto(s)
Proteína Quinasa C/metabolismo , Proteínas Quinasas/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo , Proteínas Adaptadoras Transductoras de Señales/metabolismo , Secuencias de Aminoácidos , Animales , Proteínas Portadoras/metabolismo , Línea Celular , Embrión de Mamíferos/citología , Fibroblastos/metabolismo , Humanos , Ratones , Modelos Moleculares , Complejos Multiproteicos/metabolismo , Pliegue de Proteína , Proteína Quinasa C/química , Proteínas Proto-Oncogénicas c-akt/química , Serina-Treonina Quinasas TOR
16.
Radiology ; 245(3): 742-50, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17923509

RESUMEN

PURPOSE: To measure prospectively and directly both organ dose and effective dose (ED) for adult cardiac and pulmonary computed tomographic (CT) angiography by using current clinical protocols for 64-detector CT in an anthropomorphic female phantom and to estimate lifetime attributable risk of breast and lung cancer incidence on the basis of measured ED and organ dose. MATERIALS AND METHODS: Cardiac and pulmonary 64-detector CT angiography was performed by using current clinical protocols to evaluate the pulmonary veins (electrocardiographically [ECG] gated, 64 sections at 0.625-mm collimation, 120 kVp, 300 mA, 0.35-second tube rotation), native coronary arteries (ECG gated; 64 sections at 0.625 mm; 120 kVp; maximum current, 500-750 mA; minimum, 100-350 mA; 0.35-second tube rotation) and pulmonary embolus (64 sections at 1.25 mm, 140 kVp, 645 mA, 0.5-second tube rotation). Absorbed organ doses were measured by using an anthropomorphic female phantom and metal oxide semiconductor field effect transistor detectors. ED was calculated from measured organ doses and the dose-length product. RESULTS: ED for current adult cardiac and pulmonary 64-detector CT angiography protocols were 12.4-31.8 mSv. Overall, skin, breast, and esophagus and heart had the highest recorded absorbed organ doses. Relative risk for breast cancer incidence for girls and women was 1.004-1.042 for a single examination. Relative risk for lung cancer incidence for men and women was 1.005-1.076 from a single examination. CONCLUSION: EDs and organ doses from 64-detector CT are higher than those previously reported for adult cardiac and pulmonary CT angiography protocols. Risk for breast and lung cancer induction from these studies is greatest for the younger patient population.


Asunto(s)
Angiografía/efectos adversos , Angiografía/métodos , Neoplasias de la Mama/epidemiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Neoplasias Pulmonares/epidemiología , Neoplasias Inducidas por Radiación/epidemiología , Fantasmas de Imagen , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/instrumentación , Protocolos Clínicos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Femenino , Humanos , Incidencia , Estudios Prospectivos , Dosis de Radiación , Medición de Riesgo
17.
J Comput Assist Tomogr ; 31(4): 544-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17882029

RESUMEN

PURPOSE: To determine the organ doses and total body effective dose (ED) delivered to an anthropomorphic phantom by multidetector array computed tomography (MDCT) when using standard clinical adult body imaging protocols. MATERIALS AND METHODS: Metal oxide semiconductor field effect transistor (MOSFET) technology was applied during the scanning of a female anthropomorphic phantom to determine 20 organ doses delivered during clinical body computed tomography (CT) imaging protocols. A 16-row MDCT scanner (LightSpeed, General Electric Healthcare, Milwaukee, Wis) was used. Effective dose was calculated as the sum of organ doses multiplied by a weighting factor determinant found in the International Commission on Radiological Protection Publication 60. Volume CT dose index and dose length product (DLP) values were recorded at the same time for the same scan. RESULTS: Effective dose (mSv) for body MDCT imaging protocols were as follows: standard chest CT, 6.80 +/- 0.6; pulmonary embolus CT, 13.7 +/- 0.4; gated coronary CT angiography, 20.6 +/- 0.4; standard abdomen and pelvic CT, 13.3 + 1.0; renal stone CT, 4.51 + 0.45. Effective dose calculated by direct organ measurements in the phantom was 14% to 37% greater than those determined by the DLP method. CONCLUSIONS: Effective dose calculated by the DLP method underestimates ED as compared with direct organ measurements for the same CT examination. Organ doses and total body ED are higher than previously reported for MDCT clinical body imaging protocols.


Asunto(s)
Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Antropometría , Femenino , Humanos , Planificación de la Radioterapia Asistida por Computador , Transistores Electrónicos
18.
AJR Am J Roentgenol ; 189(1): 12-8, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17579144

RESUMEN

OBJECTIVE: The purpose of our study was to determine a dose range for cardiac-gated CT angiography (CTA) in children. MATERIALS AND METHODS: ECG-gated cardiac CTA simulating scanning of the heart was performed on an anthropomorphic phantom of a 5-year-old child on a 16-MDCT scanner using variable parameters (small field of view; 16 x 0.625 mm configuration; 0.5-second gantry cycle time; 0.275 pitch; 120 kVp at 110, 220, and 330 mA; and 80 kVp at 385 mA). Metal oxide semiconductor field effect transistor (MOSFET) technology measured 20 organ doses. Effective dose calculated using the dose-length product (DLP) was compared with effective dose determined from measured absorbed organ doses. RESULTS: Highest organ doses included breast (3.5-12.6 cGy), lung (3.3-12.1 cGy), and bone marrow (1.7-7.6 cGy). The 80 kVp/385 mA examination produced lower radiation doses to all organs than the 120 kVp/220 mA examination. MOSFET effective doses (+/- SD) were as follows: 110 mA: 7.4 mSv (+/- 0.6 mSv), 220 mA: 17.2 mSv (+/- 0.3 mSv), 330 mA: 25.7 mSv (+/- 0.3 mSv), 80 kVp/385 mA: 10.6 mSv (+/- 0.2 mSv). DLP effective doses for diagnostic runs were as follows: 110 mA: 8.7 mSv, 220 mA: 19 mSv, 330 mA: 28 mSv, 80 kVp/385 mA: 12 mSv. DLP effective doses exceeded MOSFET effective doses by 9.7-17.2%. CONCLUSION: Radiation doses for a 5-year-old during cardiac-gated CTA vary greatly depending on parameters. Organ doses can be high; the effective dose may reach 28.4 mSv. Further work, including determination of size-appropriate mA and image quality, is important before routine use of this technique in children.


Asunto(s)
Angiografía , Carga Corporal (Radioterapia) , Radiometría/métodos , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X , Recuento Corporal Total/métodos , Preescolar , Electrocardiografía , Humanos , Dosis de Radiación , Protección Radiológica/métodos , Radiometría/instrumentación , Efectividad Biológica Relativa
19.
Radiology ; 222(1): 278-83, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11756737

RESUMEN

Fifty-two patients with known or suspected hypervascular malignancy were examined to determine the technical feasibility of performing single-breath-hold dynamic subtraction computed tomography (CT) of the liver with multi-detector row helical CT. The precontrast and hepatic arterial CT scans, which were acquired during the same breath hold, were subtracted. The mean liver-to-muscle contrast ratio on the precontrast, hepatic arterial, and subtracted images was 1.3, 1.4, and 2.3, respectively. In 13 patients with lesions, the subtracted images showed a 2.5-fold increase in mean lesion contrast compared with the hepatic arterial CT scans.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Neovascularización Patológica/diagnóstico por imagen , Estudios Prospectivos , Técnica de Sustracción