Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Knee Surg ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38677298

RESUMEN

Printed porous titanium metaphyseal cones have become a mainstay for managing bone loss in revision total knee arthroplasty (rTKA). A short or long stem is routinely used when implanting a cone to augment fixation and offload stresses. This retrospective analysis compared the short-term survivorships and functional outcomes for use of a short or long stem with a metaphyseal cone.A total of 179 cases using metaphyseal cones and stems with median follow-up of 1.95 years (interquartile range, 1.00-2.14) were compared based on stem type. There were 55 cases with long stem(s) and 124 cases with short stem(s). Cases with both long and short stems were excluded. Demographics, Kaplan-Meier survivorships, and preoperative and 1-year postoperative patient-reported outcome measures (PROMs; 2011 Knee Society Score [KSS] objective knee score, function, and satisfaction scores; EuroQol five-dimension scale; and Short Form Survey Physical Component Summary and Mental Component Summary scores) were compared using t-tests with a significance level of α = 0.05. There were no significant differences in body mass index (mean ± standard deviation) or sex (men [%]) between the short and long stem cohorts (32.3 ± 5.3, 36.3% and 31.5 ± 5.5, 38.2%, respectively; p > 0.05). Patients who had short stems were younger (65.9 ± 8.8 vs. 69.0 ± 9.4, p = 0.0323).Revision-free survivorship for the femoral or tibial component was 100% for long stems and 98.2% for short stems at 1 and 2 years, respectively (log-rank p = 0.6330). The two revisions in the short group were for infection, thus the survivorship for aseptic loosening was 100% at 2 years for both cohorts. There were no significant differences in preoperative or postoperative PROMs.This study demonstrated that highly porous printed metaphyseal cones provided rTKA with excellent early survivorship and similar PROMs whether a short or long stem was used. Additional studies will be needed to discern longer term differences.

2.
J Biomed Mater Res B Appl Biomater ; 112(2): e35388, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38334714

RESUMEN

The trace element strontium (Sr) enhances new bone formation. However, delivering Sr, like other materials, in a sustained manner from a ceramic bone graft substitute (BGS) is difficult. We developed a novel ceramic BGS, polyphosphate dicalcium phosphate dehydrate (P-DCPD), which delivers embedded drugs in a sustained pattern. This study assessed the in vitro and in vivo performance of Sr-doped P-DCPD. In vitro P-DCPD and 10%Sr-P-DCPD were nontoxic and eluents from 10%Sr-P-DCPD significantly enhanced osteoblastic MC3T3 cell differentiation. A sustained, zero-order Sr release was observed from 10%Sr-P-DCPD for up to 70 days. When using this BGS in a rat calvaria defect model, both P-DCPD and 10% Sr-P-DCPD were found to be biocompatible and biodegradable. Histologic data from decalcified and undecalcified tissue showed that 10%Sr-P-DCPD had more extensive new bone formation compared with P-DCPD 12-weeks after surgery and the 10%Sr-P-DCPD had more organized new bone and much less fibrous tissue at the defect margins. The new bone was formed on the surface of the degraded ceramic debris within the bone defect area. P-DCPD represented a promising drug-eluting BGS for repair of critical bone defects.


Asunto(s)
Sustitutos de Huesos , Fosfatos de Calcio , Fosfatos , Polifosfatos , Ratas , Animales , Polifosfatos/farmacología , Sustitutos de Huesos/farmacología , Estroncio/farmacología , Cerámica/farmacología , Cráneo
3.
J Arthroplasty ; 38(7S): S247-S251, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37084923

RESUMEN

BACKGROUND: Recently, a state-wide registry identified fracture as a major cause of total hip arthroplasty revision. There were 52.8% of revisions occurring within 6 months (fracture leading cause). Registry sites have a 'surgeon champion' who acts as liaison and advocate. This study evaluated the effect of surgeon volume and role of 'surgeon champion' on fracture rates. METHODS: There were 95,948 cases from 2012 to 2019 queried with peri-implant femoral fractures identified (within 6 months). Funnel plots were generated to compare individual surgeon-specific fracture rates. Surgeons who had a fracture rate below the confidence interval were labeled 'green' (lower than mean), within were 'yellow' (no difference), and above were 'red' (significantly higher). RESULTS: For all surgeons, 19.6% were red, 72.1% yellow, and 8.3% green. There were 17.2% 'surgeon champions' and 6.2% 'nonchampions' that were green (P = .01), while 20.7 and 19.3% were red (P = .82). There was a significant association between volume and performance (P < .01). No surgeons in the lower two quartiles (<84; 84 to 180 cases), while 4 and 29% of higher-volume surgeons (181 to 404; >404 cases) were green. There was no statistical difference in red status by volume (P = .53). CONCLUSION: 'Surgeon champions' and high-volume surgeons were more likely to be high performers but not less likely to be low performers. Active involvement in quality improvement and/or high volume was associated with better outcomes but did not impart complication immunity. 'Green' surgeons should mentor colleagues to help reduce fractures by re-evaluating modifiable factors. Analyzing outcomes to promote quality and decrease complications is paramount.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Humanos , Mejoramiento de la Calidad , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fémur/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Sistema de Registros , Reoperación
4.
J Arthroplasty ; 38(7 Suppl 2): S221-S226.e2, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36889526

RESUMEN

BACKGROUND: Outcome data for newer uncemented total knee arthroplasty (TKA) designs has been mixed. Registry studies showed worse survivorship, but clinical trials have not demonstrated differences compared to cemented designs. There has been renewed interest in uncemented TKA with modern designs and improved technology. The utilizations of uncemented knees in Michigan, 2-year outcomes, and the effects of age and sex were evaluated. METHODS: A statewide database from 2017 through 2019 was analyzed for incidence, distribution, and early survivorship of cemented versus uncemented TKAs. There was 2-year minimum follow-up. Kaplan-Meier survival analysis was used to generate time to first revision cumulative percent revision curves. The impacts of age and sex were examined. RESULTS: Use of uncemented TKAs increased from 7.0 to 11.3%. Uncemented TKAs were more commonly men, younger, heavier, American Society of Anesthesiologists score > 2, and opioid users (P < .05). At 2 years, overall cumulative percent revision was higher in uncemented (2.44% [2.00, 2.99]) versus cemented (1.76% [1.64, 1.89]), particularly in women uncemented (2.41 [1.87, 3.12]) versus cemented (1.64 [1.50, 1.80]). Revision rates were greater with uncemented women >70 years (1.2% 1 year, 1.02% 2 years) versus < 70 years (0.56%, 0.53%), notably uncemented were inferior in both groups (P < .05). Men, regardless of age, had similar survivorships with both cemented and uncemented designs. CONCLUSION: The use of an uncemented TKA had an increased risk of early revision compared to cemented. This finding, however, was only apparent in women, especially those >70 years old. Surgeons should consider cement fixation in women >70 years.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Masculino , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Supervivencia , Michigan , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Falla de Prótesis , Reoperación/efectos adversos , Sistema de Registros , Cementos para Huesos/uso terapéutico
5.
Arthroplast Today ; 15: 115-119, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35514365

RESUMEN

Background: For geriatric hip fractures, the current American College of Surgeons guideline recommends surgery within 48 hours. We sought to identify which factors delayed a patient's progression to definitive surgery at 2 associated level II trauma centers using chart abstraction. Methods: We reviewed all geriatric patients who underwent a surgical procedure for a hip fracture. Data regarding age, length of stay, procedure, and minutes from emergency department arrival to operating room (OR) were evaluated. Chart abstraction determined if cardiac or medical clearance and an echocardiogram were obtained. For patients that entered the OR over 24 hours, a reason was identified for the delay. Analysis of variance was used to compare continuous data, and chi-squared tests were used for categorical data. Results: Of 477 patients, 288 (60%) presented to the OR in under 24 hours, 114 (24%) between 24 and 36 hours, and 75 (16%) over 36 hours. There was a significant increase in length of stay for patients, over 36 hours. Patients presenting to the OR between 24 and 36 hours were often delayed due to facility reasons such as OR or surgeon availability while patients presenting over 36 hours were delayed due to medical comorbidities. Of all patients in the under-24-hours group, 34.7% had an echocardiogram compared with 56.1% and 69.3%, respectively. Similarly, 17.7% of patients received cardiac clearance in the under-24-hours group, compared with 31.8% and 48%, respectively. Conclusions: The timeliness of presentation of hip fractures to the OR is a multidisciplinary effort and requires cooperation between a variety of services to increase safety and efficiency as well as to control costs.

6.
J Arthroplasty ; 37(7S): S616-S621, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35278671

RESUMEN

BACKGROUND: While total hip arthroplasty (THA) is extremely successful, early failures do occur. The purpose of this study was to determine the cause of revision in specific patient demographic groups at 3 time points to potentially help decrease the revision risk. METHODS: Data for cases performed between 2012 and 2018 from a statewide, quality improvement arthroplasty registry were used. The database included 79,205 THA cases and 1,433 revisions with identified etiology (1,584 in total). All revisions performed at <5 years from the primary THA were reviewed. Six groups, men/women, <65, 65-75, and >75 years, were compared at revision time points <6 months, <1 year, and <5 years. RESULTS: There were obvious and significant differences between subgroups based on demographics and time points (P < .0001). Seven hundred and fifty-six (53%) of all revisions occurred within 6 months. The most common etiologies within 6 months (756 revisions) were fracture (316, 41.8%), dislocation/instability (194, 25.7%), and infection (98, 12.9%). At this early time point, the most common revision cause was fracture for all age/gender-stratified groups, ranging from 27.6% in young men to 60% in older women. Joint instability became the leading cause for revision after 1 year in all groups. CONCLUSION: This quality improvement project demonstrated clinically meaningful differences in the reason for THA revision between gender, age, and time from surgery. Strategies based on these data should be employed by surgeons to minimize the factors that lead to revision.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Anciano , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Factores de Riesgo
7.
J Biomed Mater Res B Appl Biomater ; 110(2): 412-421, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34302429

RESUMEN

Designing hydrogels for controlled drug delivery remains a big challenge. We developed a calcium polyphosphate hydrogel (CPP) as matrix for delivery of vancomycin (VCM) and erythromycin (EM) by unique ionic binding and physical wrapping. In this continuing study, we investigated if gel discs prepared by mechanical compaction (at 3000 psi pressure, C-discs) is superior to that of discs prepared by regular manual compaction (M-discs) for the release of VCM and EM (10 wt.%). Data demonstrated a significant reduction of burst release of VCM and EM in C-discs (1.8% and 5%, respectively) as compared to that from M-discs within 72 hr (55% and 60%, respectively, p < 0.05). In addition, C-discs significantly extended the VCM release (1500 hr) and EM (800 hr) as compared to M-discs (160 and 96 hr, respectively, p < 0.05). The VCM released from C-discs retained its bactericidal activity much longer (1500 hr) than that from M-discs (700 hr, p < 0.05). Raman Spectroscopy indicated an ionic bond of both VCM and EM with fully hydrated polyphosphate chains of CPP hydrogel matrix for both M-discs and C-discs. Micro CT showed that C-discs had much denser microstructures and less number/depth of microcracks as a result of high pressure. We propose that CPP hydrogel represents an excellent tool for the controllable and sustained delivery of VCM and EM. Extensive experiments are currently underway to evaluate the potential impacts of the modification of compaction techniques, other antibiotics, gel concentrations on the drug release, degradation behavior and infection control both in vitro and in vivo.


Asunto(s)
Eritromicina , Vancomicina , Antibacterianos/química , Antibacterianos/farmacología , Calcio , Eritromicina/farmacología , Hidrogeles/química , Hidrogeles/farmacología , Polifosfatos , Vancomicina/química , Vancomicina/farmacología
8.
J Knee Surg ; 34(9): 924-929, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31905413

RESUMEN

Readmission penalties have encouraged the implementation of protocols to reduce readmission rates. We hypothesized that by keeping postoperative patients, who return to the emergency department (ED) in a clinical decision unit (CDU) until being evaluated by the orthopaedic team, there would be a reduction in the readmission rate after total joint arthroplasty (TJA) at our institution. Our institution mandated the use of the CDU for all potential orthopaedic TJA readmissions. A retrospective review of prospectively collected data was performed on 365 patients who presented to the ED after either total hip arthroplasty (THA) or total knee arthroplasty (TKA). Patients presenting in the year prior to the implementation of the CDU program were compared with patients presenting in the year after implementation. Demographics, length of stay, comorbidities, and 30-day readmission rates were recorded. Additionally, a financial analysis was performed. Overall, for THA and TKA, there were a combined 141 ED visits prior to the implementation of the CDU program and 224 afterward; of these, 40 were readmitted before the CDU program and only 13 were readmitted afterward (p < 0.01). The financial analysis found that the overall 90-day cost for patients in the postoperative period was nearly $800 lower on average (p = 0.027) post-CDU implementation.During the first year of the CDU project at our institution, we significantly reduced the readmission rates following TJA and demonstrated significant cost saving. This is a Level III, prognostic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Unidades de Observación Clínica , Humanos , Tiempo de Internación , Readmisión del Paciente , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Factores de Riesgo
9.
J Knee Surg ; 33(12): 1232-1237, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31288268

RESUMEN

Pulmonary emboli (PEs) occur in medical and postoperative total joint arthroplasty (TJA) patients. These are different patient populations, yet both undergo identical diagnosis and treatment regardless of PEs size and quantity. To date, there has been no analysis of the location, size, and quantity of emboli that occur postoperatively in TJA compared with general medical patients. We hypothesized TJA patients would have different size and distribution of PEs per event compared with medical patients. A retrospective chart review was conducted of patients who underwent total hip or knee arthroplasty in comparison to general medical patients at our institution from 2006 to 2011 with a PE diagnosis. Medical co-morbidities, sex, age, procedure, postoperative day, size, and location of PE using spiral computed tomography were recorded using a novel mapping scheme. Embolus size was defined based on blockage level in the pulmonary arterial tree. Of the 4,178 TJA patients reviewed, 51 were diagnosed with a PE. A total of 67% of TJA patients were women, yet women represented 90% (n = 46) of TJA PE patients (p < 0.0001). Medical patients had an equal distribution of men and women with PEs. Orthopaedic patients averaged more (4.0 vs. 2.2, p < 0.0001) and smaller PEs compared with medical patients (p < 0.0001). In conclusion, women undergoing TJA had significantly higher risk of developing PE compared with male arthroplasty or medical patients. Differences were observed in size and distribution of PEs between medical and TJA patients, which suggest a different nature of embolic phenomenon.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Embolia Pulmonar/diagnóstico por imagen , Adulto , Anciano , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/etiología , Estudios Retrospectivos , Factores Sexuales , Tomografía Computarizada por Rayos X
10.
J Knee Surg ; 33(6): 560-564, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31049916

RESUMEN

Ambient temperature and time to implantation can affect the material properties of polymethylmethacrylate bone cement, and cement intrusion depth has been shown to affect implant fixation. The purpose of this study was to examine the effects of ambient temperature and time to implantation on depth of intrusion, and the effect of ambient temperature on setting time. Two types of cements were evaluated: cement A (Simplex P,medium Q7 viscosity) and cement B (Palacos R, high viscosity). Dough, working and setting times were determined, as well as intrusion depth, at different temperatures per American Society of Testing and Materials (ASTM) protocol F451. A vacuum mixer was used in a temperature- and humidity-controlled environment at 60, 65, and 70°F. At each temperature, the cement was placed into an intrusion mold at 0, 50, and 100% of working time. Increasing ambient temperature resulted in a significant decrease in dough and working and setting times for both cements (p = 0.038 - < 0.001). At each working time point and temperature, cement A showed significantly more intrusion than cement B (p = 0.044 - < 0.001). There was no effect of temperature on intrusion depth regardless of working time to implantation for either cement with the exception of cement B when comparing 60 versus 70°F at 0% working time (p = 0.004). Both cements showed a significant decrease in intrusion as time to implantation increased (p < 0.001). In conclusion, there are large inherent differences in properties of commercially available cements, and these properties are affected by such variables as time to implantation and ambient temperatures. An understanding of these properties may aid the surgeon in optimizing surgical outcomes.


Asunto(s)
Cementos para Huesos , Metilmetacrilato , Polimetil Metacrilato , Temperatura , Ensayo de Materiales , Prótesis e Implantes , Viscosidad
11.
J Biomed Mater Res B Appl Biomater ; 108(2): 475-483, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31070858

RESUMEN

Calcium polyphosphate (CPP) hydrogel is used to load erythromycin (EM) and vancomycin (VCM) by means of two loading methods: they are either added directly to the formed CPP hydrogel (Gel Mixture method) or mixed with CPP powders, followed by the formation of CPP-antibiotic hydrogel (Powder Mixture method). The release of loaded antibiotics from CPP hydrogel is measured up to 48 hr. Compared to Powder Mixture method, Gel Mixture method significantly reduced the burst release of embedded antibiotics. A significant change in CPP hydrogel Raman characteristic peaks is observed only in Gel Mixture method, indicating a close interaction between embedded antibiotics with CPP hydrogel matrix. In contrast, a similarity between characteristic peaks of CPP hydrogel and Powder Mixture method shows that antibiotic incorporation does not interfere with CPP gel formation, resulting in no ionic interaction between antibiotic and polyphosphate chains. Rheometer analysis further confirms that the hydrophobic nature of EM impacts the viscoelastic properties of CPP hydrogel, whereas the hydrophilic VCM exhibits a higher loading efficiency. The potential application of CPP hydrogel as a ceramic matrix for sustained drug release warrants further investigation.


Asunto(s)
Antibacterianos/química , Fosfatos de Calcio/química , Portadores de Fármacos/química , Eritromicina/química , Hidrogeles/química , Polímeros/química , Vancomicina/química , Antibacterianos/farmacología , Composición de Medicamentos , Liberación de Fármacos , Quimioterapia Combinada , Eritromicina/farmacología , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Reología , Vancomicina/farmacología , Viscosidad
12.
Orthopedics ; 42(6): 355-360, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31505015

RESUMEN

Historically, cementless total knees were associated with early failure, which made cemented total knee arthroplasty the gold standard. Manufacturers have introduced newer uncemented technologies that provide good initial stability and use highly porous substrates for bony in-growth. The authors hypothesized that the implants would have equivalent 90-day clinical and economic outcomes. Prospectively collected data on 252 uncemented knees in the Michigan Arthroplasty Registry Collaborative Quality Initiative database were reviewed. Ninety-day outcomes, demographics, length of stay, complications, emergency department visits, readmissions, and financial data were compared with those of an age-matched group of cemented knees. Uncemented knees had shorter length of stay (1.58 vs 1.87 days; P<.01), were more frequently discharged home (90.48% vs 68.75%; P<.0001), and used less home care (6.35% vs 19.14%; P<.0001) or extended care facilities (2.78% vs 11.72%; P=.0001). More uncemented knees had "no complications." Moreover, there were no re-operations in uncemented knees, compared with 19 reoperations in cemented knees. Uncemented knees were better than age-matched counterparts for Knee injury and Osteoarthritis Outcome Score (63.69 vs 47.10, n=85 and n=43, P<.0001) and Patient-Reported Outcomes Measurement Information System (PROMIS) T-Physical and T-Mental scores (44.12 vs 39.45, P<.0001; 51.84 vs 47.82, P=.0018). Cemented cases were more expensive overall, and surgical ($6806.43 vs $5710.78; P<.01) and total hospital ($8347.65 vs $7016.11; P<.01) costs were higher. The 90-day readmission and hospital outpatient costs were not significantly different between designs. Uncemented total knee arthroplasty, when using modern technologies, is successful and economically viable for an at-risk bundle. The results of this study should alleviate fears of increased cost, early failure, complications, or poor outcomes with the use of a modern uncemented total knee arthroplasty. [Orthopedics. 2019; 42(6):355-360.].


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Resultado del Tratamiento
13.
J Knee Surg ; 32(7): 659-666, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29991080

RESUMEN

Total knee prostheses are routinely redesigned to improve performance, longevity, and to closer mimic the native kinematics of the knee. Despite continued improvements, all knee implants, even those with proven design features, have failures. We identified a cohort of patients with isolated tibial component failures that occurred in a popular and successful knee system. Our purpose was to (1) characterize the observed radiographic failure pattern; (2) investigate the biologic response that may have contributed to the failure; and (3) to determine if the failure mechanism was of a biological or a mechanical nature. Twenty-one knees from 19 patients met the inclusion criteria of isolated tibial component failure in a single knee implant system. Radiographs from the primary and revision knee surgery were analyzed for implant positioning and the failure pattern. Inflammatory biomarkers interleukin (IL)-1ß, IL-6, and tumor necrosis factor (TNF)-α were available in 16/21 knees and peripheral CD14+/16+ monocytes were measured in 14 of the aforementioned 16 knee revisions. Serum CD3, CD4, and CD19 were measured in 10 of the aforementioned 14 knees. Additionally, white blood cell (WBC) count, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were measured to rule out infection as a cause of the cytokine upregulation. Radiographic findings demonstrated that all of the 21 tibial components were implanted in either neutral or 2 to 3 degrees varus in the coronal plane, and none of the revisions was implanted in valgus. All tibias showed obvious radiographic loosening and the implant failed into varus. The inflammatory biomarkers IL-1ß, IL-6, and TNF-α were negative. WBC, ESR, and CRP were normal. Serum CD3, CD4, and CD19 flow cytometry analyses were found to be in the normal range. Peripheral CD14+/16+ and total CD16+ monocytes measurements were consistent with previous findings of patients with osteoarthritis, rather than particulate-induced inflammatory loosening. The findings support the implant failure observed in our study occurred by a different mechanism than the wear debris-induced aseptic loosening. We believe that a mechanical failure can occur based on our findings. The loosening, collapse, and debonding from the cement may have been related to the implantation technique, stresses due to favorable rotational freedoms of the implant, or patient characteristics/behavior. Continued exploration into implant failure mechanisms and particularly into the biologic response associated with failure is ongoing.


Asunto(s)
Inflamación/complicaciones , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla/efectos adversos , Falla de Prótesis/etiología , Tibia/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Fenómenos Biomecánicos , Cementos para Huesos , Ensayo de Inmunoadsorción Enzimática , Femenino , Citometría de Flujo , Humanos , Rodilla/cirugía , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis/cirugía , Diseño de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Tibia/cirugía
14.
J Bone Joint Surg Am ; 100(22): e143, 2018 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-30480606

RESUMEN

The Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) is a regional quality improvement effort that is focused on hip and knee arthroplasty. From its inception in 2012, MARCQI has grown to include data from 66 hospitals and surgery centers, and contains over 209,000 fully abstracted cases in its database. Using high-quality risk-standardized outcomes data, MARCQI drives quality improvement through a collaborative and nonpunitive structure. Quality improvement initiatives have included transfusion reduction, infection prevention, venous thromboembolism reduction, and reduction of discharge to nursing homes. In addition, MARCQI focuses on postmarket surveillance of implants by computing revision-risk estimates based on the cases that were registered prior to the end of 2016. This paper describes the impact of MARCQI on the quality of hip and knee arthroplasty care in the state of Michigan since its inception in 2012, and it briefly summarizes the recently released 5-year report.


Asunto(s)
Artroplastia de Reemplazo de Cadera/normas , Artroplastia de Reemplazo de Rodilla/normas , Mejoramiento de la Calidad , Sistema de Registros , Humanos , Michigan
15.
Orthopedics ; 41(3): e424-e431, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29708567

RESUMEN

The purpose of this study was to compare blood leukocyte profiles and metal ion concentrations between hip resurfacing arthroplasty (articular surface replacement) patients with and without revision. A total of 25 articular surface replacement patients were recruited (10 with stable implants and 15 undergoing revision). Blood concentrations of chromium (Cr) and cobalt (Co) were measured. Flow cytometry was used to quantify the subpopulations of leukocytes, including CD14+ monocytes, CD16+ monocytes, CD3+ T-lymphocytes, CD19+ B-lymphocytes, CD4+ helper T-cells, and CD45+RA memory vs naïve T-cells. Patients undergoing revision had higher blood Co (mean, 10.85 µg/L) and Cr (mean, 3.19 µg/L) levels than patients with stable implants (mean Co, 3.06 µg/L; mean Cr, 1.07 µg/L) (P<.05). The number of CD4+ helper T-cells was higher in patients with stable implants (mean, 842±311 cells/µL) than in patients undergoing revision (mean, 591±208 cells/µL) (P<.05). There was a significant association between total metal ion levels (Co+Cr) and the number of CD14+ monocytes (P=.045) and inflammatory CD16+ monocytes (P=.046). The authors observed that the increase in blood metal ions was associated with an increase in CD16+ monocytes. They believe that continued analysis of blood leukocyte profiles may be helpful in defining differences among failed articular surface replacement, stable articular surface replacement, and failed metal-on-polyethylene implants. [Orthopedics. 2018; 41(3):e424-e431.].


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cromo/sangre , Cobalto/sangre , Prótesis de Cadera , Leucocitos/metabolismo , Prótesis Articulares de Metal sobre Metal , Reoperación , Anciano , Biomarcadores/sangre , Femenino , Citometría de Flujo , Humanos , Iones , Masculino , Persona de Mediana Edad
16.
J Mech Behav Biomed Mater ; 79: 226-234, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29331590

RESUMEN

We previously described the gelation mechanism of calcium polyphosphate (CPP) in the presence of water. In this study, we developed novel and injectable poly-dicalcium phosphate dihydrate (P-DCPD) forming cement by the reaction of acidic CPP gel with alkali tetracalcium phosphate (TTCP). The setting reaction mechanism of P-DCPD is due to the intermolecular interaction between CPP gel and TTCP that was supported by XRD, AFM, Raman spectra analysis and SEM. The setting mechanism of P-DCPD is completely different from the classical calcium phosphate cement (CPC) that achieves crystallization by monophosphates reaction. P-DCPD represents a new type of poly-CPCs with significant advantages, including strong mechanical strength, excellent cohesion and easy of handling. More extensive experiments are currently underway to further evaluate the performance of P-DCPD cements, including biocompatibility, degradation behavior and bone defect hearing efficacy, among others.


Asunto(s)
Cementos para Huesos/química , Fosfatos de Calcio/química , Fuerza Compresiva , Ensayo de Materiales , Microscopía de Fuerza Atómica
17.
J Biomed Mater Res B Appl Biomater ; 106(8): 2827-2840, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29282858

RESUMEN

The influence of calcium polyphosphate (CPP) gel incorporation on the release of vancomycin and tobramycin from polymethyl methacrylate (PMMA) cement (Simplex P, SP) has been studied. Adding 10% CPP gel to SP led to a much lower burst release of vancomycin and considerably extended release of both vancomycin and tobramycin up to 24 weeks. Antibiotics released from this new material retain their bactericidal activity for up to 15 weeks. The improvement in the antibiotic release is mainly due to the molecular interactions of antibiotics with embedded CPP polyphosphate chains as confirmed by Raman spectroscopy analysis. The inclusion of CPP hydrogel also increased the SP surface roughness and pore sizes, leading to a higher release rate of antibiotics. The new material is biocompatible and has similar handling properties and mechanical strength as compared to SP cements. We believe that incorporating CPP gel provides a better and usable drug carrier for PMMA cement. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2827-2840, 2018.


Asunto(s)
Hidrogeles , Staphylococcus aureus Resistente a Meticilina/crecimiento & desarrollo , Ácidos Polimetacrílicos , Polifosfatos , Tobramicina , Vancomicina , Preparaciones de Acción Retardada/química , Preparaciones de Acción Retardada/farmacocinética , Preparaciones de Acción Retardada/farmacología , Hidrogeles/química , Hidrogeles/farmacología , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/farmacología , Polifosfatos/química , Polifosfatos/farmacología , Tobramicina/química , Tobramicina/farmacocinética , Tobramicina/farmacología , Vancomicina/química , Vancomicina/farmacocinética , Vancomicina/farmacología
18.
J Arthroplasty ; 32(9S): S259-S262, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28578845

RESUMEN

BACKGROUND: Recent health care policy changes require hospitals and physicians to demonstrate improved quality. In 2012, a prospective database was formed with the Blue Cross and Blue Shield of Michigan to improve quality of care. The purpose of this study was to analyze patient preoperative medication as predictors of outcomes after total joint arthroplasty. METHODS: Data were collected on patient's preoperative medications from 2012 to 2015 using a total joint arthroplasty database. Medications were categorized as antiplatelet, antimicrobial, anticoagulant, narcotic, steroid, insulin, or oral diabetes medication. Outcomes included hospital length of stay (LOS), discharge disposition/destination, and 90-day readmission. Univariate and multivariate regression analyses were performed. RESULTS: A total of 3959 patients were studied. Eighty percent (3163 patients) were discharged home. The remainder (795) went to an extended-care facility (ECF). Patients discharged to an ECF were taking more medications (1.13 vs 0.80 in total knee arthroplasty; 1.18 vs 0.83 in total hip arthroplasty; P <.001). Patients who were readmitted took more medications (1.0 vs 0.85; P <.01). There were more discharges to an ECF in narcotic, steroid, and diabetes medication users. Patients taking anticoagulants, narcotics, insulin, and antiplatelets had greater readmission rates. There was a significant correlation between the number of medications and an increased LOS. CONCLUSION: Patients taking more medications were more frequently discharged to an ECF and had increased LOS and readmission rates. Narcotics and diabetic medications had the greatest influence. Category and quantity of preoperative medications can be used as predictors of outcomes after arthroplasty surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Anciano , Antiinfecciosos/efectos adversos , Anticoagulantes/efectos adversos , Bases de Datos Factuales , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Tiempo de Internación , Masculino , Michigan , Persona de Mediana Edad , Narcóticos/efectos adversos , Alta del Paciente , Readmisión del Paciente , Inhibidores de Agregación Plaquetaria/efectos adversos , Periodo Preoperatorio , Estudios Prospectivos , Mejoramiento de la Calidad , Instituciones de Cuidados Especializados de Enfermería , Esteroides/efectos adversos , Resultado del Tratamiento
19.
J Arthroplasty ; 32(5): 1414-1417, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28041771

RESUMEN

BACKGROUND: As the annual demand and number of total joint arthroplasty cases increase, so do concerns of outcomes of patient with specific comorbidities relative to outcomes and costs of care. METHODS: The study cohort included 2009 primary total knee arthroplasty (TKA) patients and 905 total hip arthroplasty patients. Discharge disposition was classified as discharge to any facility or home. The comorbidities of the patients who were readmitted and those without a 90-day event were also evaluated. RESULTS: In the TKA population, age, female gender, nonsmoking status, venous thromboembolism (VTE) history, and diabetes were significantly associated with discharge to extended care facility (ECF) on univariate analysis, unlike body mass index. With multivariate analyses, female gender, age, VTE history, and diabetes were associated with ECF placement, but smoking was not. In the total hip arthroplasty population, age, female gender, and nonsmoking status were significantly associated with discharge to ECF on univariate analysis, whereas body mass index, diabetes, and VTE history were not. On multivariate analyses, female gender and age were associated with ECF, but smoking was not. The only significant finding for the readmission data was an increased rate of readmission for TKA patients of older age. CONCLUSION: The potential of projecting patient discharge and readmission allows physicians to counsel patients and improve patient expectations.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Alta del Paciente/estadística & datos numéricos , Readmisión del Paciente/estadística & datos numéricos , Tromboembolia Venosa/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Estudios de Cohortes , Comorbilidad , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Instituciones de Cuidados Especializados de Enfermería
20.
J Arthroplasty ; 32(4): 1272-1279, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28065625

RESUMEN

BACKGROUND: Monofilament and barbed monofilament sutures have been shown in in vitro models to have less bacterial adherence than braided suture. This study evaluates bacterial adherence to suture materials and tissue reactivity with an in vivo contaminated wound mouse model. METHODS: Staphylococcus aureus was used to create an in vivo contaminated wound model at 2 amounts (106 colony-forming units [CFU] and 108 CFU) using a mouse air pouch. Three types of commonly used absorbable suture were evaluated: braided, monofilament, and barbed monofilament. Bacterial suture adherence was evaluated with suture culture, a photon-capturing camera system, and scanning electron microscopy. Tissue reactivity was assessed through histology and protein expression. RESULTS: The braided suture group with the high amount of S aureus exhibited frank purulence and air pouch hypertrophy in all 8 mice. A significant difference was found between suture groups inoculated with 108 CFU (P < .05) as measured by bacterial culture concentration using the optical density method. The braided suture hosted more bacteria than either monofilament (P < .005) or barbed monofilament suture (P < .005). No difference was appreciated between the monofilament and barbed monofilament groups. Kruskal-Wallis test demonstrated a significant difference between groups in regard to levels of tumor necrosis factor-α (P < .05) and interleukin-1 (P < .05). CONCLUSION: Our in vivo contaminated wound model demonstrated that barbed monofilament suture performed similarly to monofilament suture and better than braided suture in terms of bacterial adherence, biofilm formation, and tissue reactivity.


Asunto(s)
Adhesión Bacteriana , Infecciones Estafilocócicas/prevención & control , Infección de la Herida Quirúrgica/prevención & control , Suturas , Animales , Biopelículas , Femenino , Interleucina-1/metabolismo , Ratones Endogámicos BALB C , Microscopía Electrónica de Rastreo , Infecciones Estafilocócicas/metabolismo , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus , Infección de la Herida Quirúrgica/metabolismo , Técnicas de Sutura , Factor de Necrosis Tumoral alfa/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA