JTCVS Open ; 17: 111-120, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420560

RESUMEN

Background: Tricuspid valve disease significantly affects 1.6 million Americans. The gold standard treatment for tricuspid disease is the implantation of annuloplasty devices. These ring-like devices come in various shapes and sizes. Choices for both shape and size are most often made by surgical intuition rather than scientific rationale. Methods: To understand the impact of shape and size on valve mechanics and to provide a rational basis for their selection, we used a subject-specific finite element model to conduct a virtual case study. That is, we implanted 4 different annuloplasty devices of 6 different sizes in our virtual patient. After each virtual surgery, we computed the coaptation area, leaflet end-systolic angles, leaflet stress, and chordal forces. Results: We found that contoured devices are better at normalizing end-systolic angles, whereas the one flat device, the Edwards Classic, maximized the coaptation area and minimized leaflet stress and chordal forces. We further found that reducing device size led to increased coaptation area but also negatively impacted end-systolic angles, stress, and chordal forces. Conclusions: Based on our analyses of the coaptation area, leaflet motion, leaflet stress, and chordal forces, we found that device shape and size have a significant impact on valve mechanics. Thereby, our study also demonstrates the value of simulation tools and device tests in "virtual patients." Expanding our study to many more valves may, in the future, allow for universal recommendations.

2.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36951551

RESUMEN

OBJECTIVES: Pathophysiology of function tricuspid regurgitation (FTR) is incompletely understood. We set out to comprehensively evaluate geometric and tissue remodelling of the tricuspid valve complex in ovine FTR. METHODS: Twenty adult sheep underwent left thoracotomy and pulmonary artery banding (PAB) to induce right heart pressure overload and FTR. After 8 weeks, 17 surviving animals and 10 healthy controls (CTL) underwent sternotomy, echocardiography and implantation of sonomicrometry crystals on right ventricle and tricuspid valvular apparatus. Haemodynamic and sonomicrometry data were acquired in all animals after weaning from cardiopulmonary bypass. Leaflet tissue was harvested for pentachrome histologic analysis and biomechanical testing. RESULTS: Animal weight was 62 ± 5 and 63 ± 3 kg for CTL and PAB, respectively (P = 0.6). At terminal procedure, systolic pulmonary artery pressure was 22 ± 3 and 40 ± 7 mmHg for CTL and PAB, respectively (P = 0.0001). The mean TR grade (+0-4) was 0.8 ± 0.4 and 3.2 ± 1.2 (P = 0.0001) for control and banded animals, respectively. Right ventricle volume (126 ± 13 vs 172 ± 34 ml, P = 0.0019), tricuspid annular area (651 ± 109 vs 865 ± 247 mm2, P = 0.037) and area between papillary muscle tips (162 ± 51 vs 302 ± 75 mm2, P = 0.001) increased substantially while systolic excursion of anterior leaflet decreased significantly (23.8 ± 6.1° vs 7.4 ± 4.5°, P = 0.001) with banding. Total leaflet surface area increased from 806 ± 94 to 953 ± 148 mm2 (P = 0.009), and leaflets became thicker and stiffer. CONCLUSIONS: Detailed analysis of the tricuspid valve complex revealed significant ventricular, annular, subvalvular and leaflet remodelling to be associated with ovine functional tricuspid regurgitation. Durable surgical repair of severe FTR may require a multi-level approach to the valvular apparatus.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Ovinos , Animales , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Ecocardiografía , Ventrículos Cardíacos , Catéteres
3.
Semin Thorac Cardiovasc Surg ; 33(2): 356-364, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32977016

RESUMEN

Functional tricuspid regurgitation (FTR) is thought to arise due to annular dilation and alteration of right ventricular (RV) geometry in the presence of normal leaflets, yet mitral leaflets have been shown to remodel significantly in functional mitral regurgitation. We set out to evaluate tricuspid valve anterior leaflet deformations in ovine FTR. Eleven animals (FTR group) underwent implantation of a pacemaker with high rate pacing to induce biventricular dysfunction and at least moderate TR. Subsequently, both FTR (n = 11) and Control (n = 12) animals underwent implantation of 6 sonomicrometry crystals around the tricuspid annulus, 4 on the anterior leaflet, and 14 on RV epicardium. Tricuspid valve geometry and anterior leaflet strains were calculated from crystal coordinates. Left ventricular ejection fraction and RV fractional area change were significantly lower in FTR animals versus Control. Tricuspid annular area, septo-lateral diameter, RV pressures were all significantly greater in the FTR group. Mean TR grade (+0-3) was 0.7 ± 0.5 in Control and 2.4 ± 0.5 in FTR (P = < 0.001). The anterior leaflet area and length increased significantly. Global radial leaflet strain was significantly lower in FTR mostly driven by decreased free edge leaflet strain. Global circumferential anterior leaflet strain was also significantly lower in FTR with more remarkable reduction in the belly region. Rapid ventricular pacing in sheep resulted in a clinically pertinent model of RV and annular dilation with FTR and leaflet enlargement. Both circumferential and radial anterior leaflet strains were significantly reduced with FTR. Functional TR may be associated with alteration of leaflet mechanical properties.


Asunto(s)
Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Animales , Ovinos , Volumen Sistólico , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Función Ventricular Izquierda
4.
Elife ; 92020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33320094

RESUMEN

Over 1.6 million Americans suffer from significant tricuspid valve leakage. In most cases this leakage is designated as secondary. Thus, valve dysfunction is assumed to be due to valve-extrinsic factors. We challenge this paradigm and hypothesize that the tricuspid valve maladapts in those patients rendering the valve at least partially culpable for its dysfunction. As a first step in testing this hypothesis, we set out to demonstrate that the tricuspid valve maladapts in disease. To this end, we induced biventricular heart failure in sheep that developed tricuspid valve leakage. In the anterior leaflets of those animals, we investigated maladaptation on multiple scales. We demonstrated alterations on the protein and cell-level, leading to tissue growth, thickening, and stiffening. These data provide a new perspective on a poorly understood, yet highly prevalent disease. Our findings may motivate novel therapy options for many currently untreated patients with leaky tricuspid valves.


Asunto(s)
Matriz Extracelular/metabolismo , Insuficiencia Cardíaca/complicaciones , Hemodinámica , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/metabolismo , Función Ventricular Izquierda , Función Ventricular Derecha , Adaptación Fisiológica , Animales , Modelos Animales de Enfermedad , Metabolismo Energético , Matriz Extracelular/genética , Matriz Extracelular/patología , Colágenos Fibrilares/genética , Colágenos Fibrilares/metabolismo , Regulación de la Expresión Génica , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Masculino , Oveja Doméstica , Transducción de Señal , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/metabolismo , Insuficiencia de la Válvula Tricúspide/fisiopatología
5.
Ann Thorac Surg ; 110(5): 1605-1614, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32251659

RESUMEN

BACKGROUND: Functional tricuspid regurgitation due to annular and ventricular dilatation is increasingly recognized as a significant source of morbidity and mortality. To repair the annulus, surgeons implant one of many annuloplasty devices that differ in size, 3-dimensional (3D) shape, and stiffness. However, there have been no quantitative comparisons between various available devices. METHODS: Three-dimensional scanning, micro-computed tomography imaging, analytical methods, and mechanical tests were used to compare 3 Edwards Lifesciences (Irvine, CA) and 3 Medtronic (Minneapolis, MN) annuloplasty devices of all available sizes. We measured in-plane metrics of maximum diameter, perimeter, area, height, as well as elevation and curvature profiles. Furthermore, we computed bending stiffness as well as the maximum and minimum axes of the bending stiffness. RESULTS: Most annular prostheses differed little in their in-plane geometries but varied significantly in height. In-plane properties deviated significantly from measurements of healthy human tricuspid annuli. Height of the Edwards' MC3 and Medtronic's Contour 3D resembled healthy human tricuspid valve annuli, whereas the Edwards' Physio and Classic, and Medtronic's TriAd, did not. Additionally, the elevation profiles of the MC3 and Contour 3D and curvature profiles between all devices were consistent and matched those of healthy human annuli. The tested devices also differed in their bending stiffness, both in terms of absolute values and their maximum and minimum axes. CONCLUSIONS: Contoured devices, such as Edwards' MC3 and Medtronic's Contour 3D, most accurately resembled the healthy human tricuspid annulus but differed significantly in bending stiffness. To what extent prosthesis properties and shape affect tricuspid valve function remains to be determined.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Fenómenos Biomecánicos , Diseño de Equipo , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología