Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Ir J Med Sci ; 193(1): 257-263, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37450259

RESUMEN

BACKGROUND: The widespread use of intraoperative fluoroscopy in orthopaedic procedures has revolutionised surgical practice. However, there are risks associated with using ionising radiation. Efforts to reduce radiation exposure include low-dose imaging protocols and lead protective equipment. Current communication during fluoroscopic procedures can be inefficient and lead to excessive radiation exposure for patients and staff. AIMS: This study aims to implement a communication tool with standardised commands to reduce radiation exposure in an Irish orthopaedic department. METHODS: Radiation exposure was evaluated using dose-area product (DAP) measured in uGy/m2. A control group was recorded before implementing the communication tool. Training sessions were conducted and posters of the standardised commands were displayed. Feedback was collected from surgeons and radiographers via surveys. Statistical analysis was performed to compare pre- and post-intervention groups. RESULTS: A total of 673 surgical cases were included over 6 months. The post-intervention group showed a mean reduction in radiation exposure from 59.8 to 36.4 uGy/m2 (p < 0.011). Subset analyses revealed reduced radiation exposure for ORIF of the distal radius, ankle, humerus, and phalanges. Surgeons and radiographers recognised the need for improved communication and expressed willingness to learn the new tool. CONCLUSIONS: Implementation of a standardised communication tool effectively reduced patient and staff radiation exposure. It was also believed to have a positive effect on theatre staff morale. Incorporating a universal language tool into training programmes could be beneficial. Surgeons and radiographers provided several suggestions to improve the effectiveness and implementation of this tool into other units.


Asunto(s)
Procedimientos Ortopédicos , Exposición a la Radiación , Humanos , Dosis de Radiación , Procedimientos Ortopédicos/métodos , Comunicación , Fluoroscopía/métodos
2.
Injury ; 55(2): 111185, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38070327

RESUMEN

INTRODUCTION: Hip fractures have become a major public health priority due to their increasing incidence. Intramedullary (IM) nailing has gained popularity as a surgical technique for managing these fractures. However, comparative studies with extramedullary devices indicate potentially increased mechanical complications associated with IM nailing. Specifically, there have been recent reports of early implant fracture associated with the TFNA system. This study compares the rate of mechanical complications between 3 implants. Secondarily, we analysed the factors associated with implant fracture and all other mechanical complications. METHODS: This retrospective study included 803 IM nails performed between 2008-2021 for the fixation of proximal femur fractures at a level 1 trauma centre. We recorded patient demographics, AO fracture classification, implant specification and intra-operative parameters such as tip-apex distance, Cleveland index, reduction quality, presence of medial calcar integrity, neck-shaft angle. The outcomes analysed included implant fracture, lag screw cut-out, >10 mm backing out, autodynamisation, periprosthetic fracture, non-union at 6 months and time to revision surgery. RESULTS: The overall implant fracture rate was 3.1 % (25/803), with no statistically significant difference between the three devices (p = 0.51). The TFNA group included 183 patients with a median follow-up of 1.6 years. The TFNA fracture rate was 2.2 % (4/183) which occurred at 207 +/- 16.66 days post-operatively. The rate of all mechanical complications was 4.9 % in the TFNA group, 12.9 % in the InterTAN group and 17 % in the IMHS group. Non-union (p < 0.001) and increasing lag screw length (p < 0.02) were identified as risk factors for implant fracture and other mechanical complications. The reverse oblique fracture pattern (AO 31 A3.1) was associated with mechanical complications only (p < 0.01). The cumulative survival rates without revision for the TFNA, InterTAN, IMHS groups were 97.8 %, 95.5 % and 87.9 % respectively at 2.5 years. DISCUSSION: The rates of implant fracture were comparable between the three nailing systems. The TFNA provides effective fixation for proximal femur fractures using a traditional screw without cement augmentation. The TFNA was associated with an overall reduction in mechanical complications compared to the InterTAN and IMHS. Previously reported mechanical complications associated with IM Nails may relate to older device designs.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Fracturas Femorales Proximales , Humanos , Fijación Intramedular de Fracturas/métodos , Clavos Ortopédicos/efectos adversos , Estudios Retrospectivos , Tornillos Óseos
3.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4773-4781, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37516985

RESUMEN

PURPOSE: The Attune® total knee arthroplasty system was introduced in 2013 to address lingering issues of patient dissatisfaction. However, recent literature reports concerns of early tibial tray debonding. The aim of this study was to compare the incidence of radiolucent lines, survivorship and patient reported outcome-measures between the Attune® system and the well-established Triathlon® system. METHODS: This retrospective database review was conducted at a single institution in Cork, Ireland. All primary Attune® (N = 445) and Triathlon® (N = 285) systems implanted between 2015 and 2016 were reviewed. Radiolucent lines were assessed for those with a minimum two-year radiological follow-up (Attune® = 338; Triathlon® = 231). X-rays were taken post op, at 6 months, 2 years and 5 years. Radiolucent lines were documented using the Modern Knee Society Radiographic System. Five-year survival was assessed using Kaplan-Meier analysis with the Log Rank method to determine statistical significance. The Oxford Knee Score and EQ-5D-5L, were collected pre-op, at 6 months, 2 years and 5 years post-operatively and compared using the Kruskal-Wallis Test. RESULTS: The Attune® had a higher proportion of radiolucent lines at the tibial tray [87.1% (54/62) vs 61.4% (27/44); p = 0.001] and at the implant-cement interface [62.9% (39/62) vs 43.2% (19/44); p = 0.02]. Conversely, the Triathlon® had a higher proportion AT the femur [38.6% (17/44) vs 12.9% (8/62); p = 0.001] and at the cement-bone interface [56.8% (25/44) vs 37.1% (23/62); p = 0.02]. The overall frequency of radiolucent lines was similar in both the Attune® and Triathlon® groups [17.8%, (60/338) vs 17.7%, (41/231); p = 0.49]. There was no difference in revision-free survival analysis at 5 years (Attune® 97.8% vs Triathlon® 95.8%; p = 0.129). The Attune® performed better at 5 years in the Oxford Knee Score [Attune® = 42.6 (SD 5.2) vs Triathlon® = 41 (SD 6.4); p = 0.001] and in the EQ-5D [Attune® = 0.773 (SD 0.187) vs Triathlon® = 0.729 (SD 0.218); p = 0.013]. There was no difference at 5 years in the EQ-VAS [Attune® = 80.4 (SD 13.7) vs Triathlon® = 78.5 (SD 15.3); p = 0.25]. CONCLUSION: The Attune® system exhibited a higher incidence of  radiolucent lines at the tibial tray. However, this did not lead to decreased survivorship at medium term follow-up compared to the Triathlon®. Furthermore, improvements in patient reported outcomes modestly favoured the Attune® system. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Radiografía , Diseño de Prótesis , Cementos para Huesos , Falla de Prótesis , Resultado del Tratamiento
4.
Surgeon ; 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37455209

RESUMEN

In response to appeals from the WHO and The Lancet, a collaborative statement from over 200 medical journals was published in September 2021, advising international governments to combat the "catastrophic harm to health" from climate change. Healthcare, specifically surgery, constitutes a major contributor to environmental harm that remains unaddressed. This article provides practical guidance that can be instituted at a departmental, hospital and national level to institute transformative, sustainable efforts into practice. We also aim to provoke healthcare leaders to discuss policy-making with respect to this issue and highlight the necessity for sustainability to become a core domain of quality improvement. The average orthopaedic service produces 60% more waste than any other surgical specialty. Fortunately, simple measures such as a comprehensive education programme can decrease waste disposal costs by 20-fold. Other simple and effective "green" measures include integrating carbon literacy into surgical training, prioritising regional anaesthesia and conducting recycling audits. Furthermore, industry must take accountability and be incentivised to limit the use of single-item packaging and single-use items. National policymakers should consider the benefits of reusable implants, reusable surgical drapes and refurbishing crutches as these are proven cost and climate-effective interventions. It is crucial to establish a local sustainability committee to maintain these interventions and to bridge the gap between clinicians, industry and policymakers.

5.
Int J Surg Case Rep ; 106: 108192, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37105027

RESUMEN

INTRODUCTION AND IMPORTANCE: Chondroblastoma is a benign cartilaginous tumour that usually presents in the epiphysis of long bones in patients aged 10-20 years old. Only 4 % of primary chondroblastoma occur in the talus. Recurrence is rare, especially in the foot and ankle and there is no consensus regarding how it is best managed. This unique case and literature review add to a limited evidence base. CASE PRESENTATION: A 21-year-old male was referred to our elective orthopaedic clinic with persistent anterior ankle pain exacerbated by weight-bearing. Radiographs and MRI revealed a 2.5 cm non-homogenous mass in the anteromedial talus with expansion of overlying bone consistent with chondroblastoma-ABC. Our patient was initially managed by intralesional curettage and autologous bone grafting but had recurrence 4.5 months postoperatively. Subsequent en bloc resection of the talar neck with talonavicular and calcaneocuboid joint fusion resulted in excellent functional outcomes and disease-free survival at 2 years follow-up. CLINICAL DISCUSSION: There are few reports discussing treatment options for recurrence in the foot and ankle. Successful treatment of primary and recurrent lesions depends on complete local resection. Repeat curettage or en bloc resection are effective options depending on tumour size and location. Type of bone graft or void filler should be considered on a case-by-case basis. Novel therapies (e.g. phenol instillation) may be beneficial. CONCLUSION: This case details successful management of recurrent chondroblastoma with en bloc resection of the talar neck and hindfoot reconstruction. We review the efficacy and outcomes of all previously reported recurrent chondroblastoma in the foot and ankle. We highlight multiple potential treatment options.

7.
Int J Surg Case Rep ; 72: 494-498, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32698273

RESUMEN

INTRODUCTION: Schwannomas are slow-growing, benign tumours normally originating from the schwann cells of the nerve sheath. Intraosseous schwannomas account for 0.175% of primary bone tumours and are extremely rare, especially outside the axial skeleton. Monoclonal gammopathy has been associated with soft tissue schwannomas but never with the intraosseous variety. PRESENTATION OF CASE: A 55-year-old woman with a background of monoclonal gammopathy of undetermined significance (MGUS) presented with a 2-year history of right thigh pain. CT scan showed a well defined, lytic lesion with a thin peripheral rim of sclerosis in the midshaft of the femur. MRI displayed a hyperintense, well marginated and homogenous lesion. Definitive diagnosis was made based on the classical histopathological appearance of schwannoma. We managed our patient with local curettage and prophylactic cephalomedullary nailing based on her high mirel score. DISCUSSION: Intraosseous schwannomas are poorly understood but most commonly reported in middle-aged women. Radiologically, their differential diagnosis includes malignant bone tumours, solitary bone cysts, aneurysmal bone cysts and giant cell tumours. As a result, they are usually diagnosed incidentally on histology. Although malignant transformation is possible in soft tissue schwannomas, all intraosseous schwannomas reported to date have been benign. CONCLUSION: This case demonstrates the importance of suspecting intraosseous schwannoma as a differential diagnosis for lytic bone lesions to avoid the overtreatment of patients. We also highlight monoclonal gammopathy of undetermined significance as a potential risk factor for a poorly understood disease and make recommendations about the appropriate management of these lesions.

8.
Int J Surg Case Rep ; 72: 245-250, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32553937

RESUMEN

INTRODUCTION: Posterior sternoclavicular joint fracture-dislocations are a rare and often missed diagnosis. They represent <1% of shoulder girdle injuries and are nine times less common than anterior dislocations. These injuries can be associated with life-threatening complications such as compression of the superior mediastinal structures including the great vessels and brachial plexus. PRESENTATION OF CASE: This case describes a 23-year-old woman who was initially discharged from the emergency department but represented 8 days later with symptoms of venous and neurogenic thoracic outlet syndrome as a result of posterior displacement of a Salter 2 fracture-dislocation at the sternoclavicular joint. Multidisciplinary consensus and patient preference resulted in the conservative management of her injuries with intensive rehabilitation and close outpatient follow-up. DISCUSSION: The evidence regarding this rare injury is evolving. It currently suggests all posteriorly displaced fracture-dislocations at the sternoclavicular joint are reduced. Closed reduction is often unsuccessful and open reduction is high risk and must be undertaken in the presence of a cardiothoracic surgeon which may not always be appropriate or in line with patient preferences. There are limited reports of successful conservative management of these injuries and none in the setting of thoracic outlet syndrome. CONCLUSION: This unique case report is the first to describe outcomes of a conservatively managed, posteriorly displaced fracture-dislocation at the sternoclavicular joint with associated venous and neurogenic thoracic outlet syndrome. This information will benefit select patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA