1.
Med Intensiva ; 39(9): 552-62, 2015 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-26183121

RESUMEN

In recent years, several safety alerts have questioned or restricted the use of some pharmacological alternatives to allogeneic blood transfusion in established indications. In contrast, there seems to be a promotion of other alternatives, based on blood products and/or antifibrinolytic drugs, which lack a solid scientific basis. The Multidisciplinary Autotransfusion Study Group and the Anemia Working Group España convened a multidisciplinary panel of 23 experts belonging to different healthcare areas in a forum for debate to: 1) analyze the different safety alerts referred to certain transfusion alternatives; 2) study the background leading to such alternatives, the evidence supporting them, and their consequences for everyday clinical practice, and 3) issue a weighted statement on the safety of each questioned transfusion alternative, according to its clinical use. The members of the forum maintained telematics contact for the exchange of information and the distribution of tasks, and a joint meeting was held where the conclusions on each of the items examined were presented and discussed. A first version of the document was drafted, and subjected to 4 rounds of review and updating until consensus was reached (unanimously in most cases). We present the final version of the document, approved by all panel members, and hope it will be useful for our colleagues.


Asunto(s)
Anemia/terapia , Enfermedad Crítica/terapia , Hemorragia/terapia , Anemia/tratamiento farmacológico , Antifibrinolíticos/efectos adversos , Antifibrinolíticos/uso terapéutico , Aprotinina/efectos adversos , Aprotinina/uso terapéutico , Factores de Coagulación Sanguínea/efectos adversos , Factores de Coagulación Sanguínea/uso terapéutico , Transfusión Sanguínea/normas , Ensayos Clínicos como Asunto , Soluciones Cristaloides , Eritropoyetina/efectos adversos , Eritropoyetina/uso terapéutico , Hematínicos/efectos adversos , Hematínicos/uso terapéutico , Humanos , Derivados de Hidroxietil Almidón/efectos adversos , Derivados de Hidroxietil Almidón/uso terapéutico , Hierro/efectos adversos , Hierro/uso terapéutico , Soluciones Isotónicas/efectos adversos , Soluciones Isotónicas/uso terapéutico , Metaanálisis como Asunto , Estudios Observacionales como Asunto , Sustitutos del Plasma/efectos adversos , Sustitutos del Plasma/uso terapéutico , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/uso terapéutico , Ácido Tranexámico/efectos adversos , Ácido Tranexámico/uso terapéutico , Reacción a la Transfusión
2.
Rev Esp Anestesiol Reanim ; 61(3): 133-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24439525

RESUMEN

INTRODUCTION AND OBJECTIVE: Occupational exposure to sevoflurane should not exceed 2 ppm. During inhalation sedation with sevoflurane using the anaesthetic conserving device (AnaConDa(®)) in the post-anaesthesia care unit, waste gases can be reduced by gas extraction systems or scavenging devices such as CONTRAfluran™. However, the efficacy of these methods has not been clearly established. To determine the safest scenario for healthcare workers during inhalation sedation with sevoflurane in the post-surgical intensive care unit. MATERIALS AND METHODS: An experimental study on occupational exposure was conducted in a post-cardiothoracic care unit during March-August 2009. The measurements were performed in four post-cardiac surgery sedated adults in post-surgical intensive care unit and four nurses at the bedside, and at four points: scenario A, inhalation sedation without gas extraction system or contrafluran as a reference scenario; scenario B, applying a gas extraction system to the ventilator; scenario C, using contrafluran; and scenario 0, performing intravenous isolation sedation. Sevoflurane concentrations were measured in the nurses' breathing area during patient care, and at 1.5 and 8 m from the ventilator using diffusive passive monitor badges. RESULTS: All badges corresponding to the nurses' breathing area were below 2 ppm. Levels of sevoflurane detected using prevention systems were lower than that in the control situation. Only one determination over 2 ppm was found, corresponding to the monitor placed nearest the gas outlet of the ventilator in scenario A. Trace concentrations of sevoflurane were found in scenario 0 during intravenous sedation. CONCLUSIONS: Administration of sevoflurane through the AnaConDa(®) system during inhalation sedation in post-surgical intensive care units is safe for healthcare workers, but gas extraction systems or scavenging systems, such as CONTRAfluran™ should be used to reduce occupational exposure as much as possible.


Asunto(s)
Contaminantes Ocupacionales del Aire/efectos adversos , Anestesia por Inhalación/instrumentación , Anestésicos por Inhalación/efectos adversos , Depuradores de Gas , Hipnóticos y Sedantes/efectos adversos , Unidades de Cuidados Intensivos , Éteres Metílicos/efectos adversos , Enfermeras y Enfermeros , Exposición Profesional , Contaminantes Ocupacionales del Aire/análisis , Anestésicos por Inhalación/administración & dosificación , Diseño de Equipo , Gases , Humanos , Hipnóticos y Sedantes/administración & dosificación , Hipnóticos y Sedantes/análisis , Exposición por Inhalación/efectos adversos , Exposición por Inhalación/análisis , Éteres Metílicos/análisis , Sala de Recuperación , Sevoflurano , Ventiladores Mecánicos