Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
AJNR Am J Neuroradiol ; 42(7): 1320-1326, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33985956

RESUMEN

BACKGROUND AND PURPOSE: Head and neck paragangliomas have been reported to be associated with mutations of the succinate dehydrogenase enzyme family. The aim of this study was to assess whether radiologic features could differentiate between paragangliomas in the head and neck positive and negative for the succinate dehydrogenase mutation. MATERIALS AND METHODS: This single-center retrospective review from January 2015 to January 2020 included 40 patients with 48 paragangliomas (30 tumors positive for succinate dehydrogenase mutation in 23 patients and 18 tumors negative for the succinate dehydrogenase mutation in 17 patients). ADC values and tumor characteristics on CT and MR imaging were evaluated by 2 radiologists. Differences between the 2 cohorts in the diagnostic performance of ADC and normalized ADC (ratio to ADC in the medulla oblongata) values were evaluated using the independent samples t test. P < .05 was considered significant. RESULTS: ADCmean (1.07 [SD, 0.25]/1.04 [SD, 0.12] versus 1.31 [SD, 0.16]/1.30 [SD, 0.20]× 10-3 mm2/s by radiologists 1 and 2; P < .001), ADCmaximum (1.49 [SD, 0.27]/1.49 [SD, 0.20] versus 2.01 [SD, 0.16]/1.87 [SD, 0.20] × 10-3 mm2/s; P < .001), normalized ADCmean (1.40 [SD, 0.33]/1.37 [SD, 0.16] versus 1.73 [SD, 0.22]/1.74 [SD, 0.27]; P < .001), and normalized ADCmaximum (1.95 [SD, 0.37]/1.97 [SD, 0.27] versus 2.64 [SD, 0.22]/2.48 [SD, 0.28]; P < .001) were significantly lower in succinate dehydrogenase mutation-positive than mutation-negative tumors. ADCminimum, normalized ADCminimum, and tumor characteristics were not statistically significant. CONCLUSIONS: ADC is a promising imaging biomarker that can help differentiate succinate dehydrogenase mutation-positive from mutation-negative paragangliomas in the head and neck.


Asunto(s)
Paraganglioma , Adulto , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/genética , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Paraganglioma/diagnóstico por imagen , Paraganglioma/genética , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
2.
AJNR Am J Neuroradiol ; 39(10): 1932-1937, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30213810

RESUMEN

BACKGROUND AND PURPOSE: Despite the development of neuroimaging, identification of focal cortical dysplasia remains challenging. The purpose of this study was to show the longitudinal changes of MR imaging and FDG-PET in patients with West syndrome and subtle focal cortical dysplasia. MATERIALS AND METHODS: Among 52 consecutive patients with West syndrome, 4 were diagnosed with subtle focal cortical dysplasia on 3T MR imaging. MR imaging and PET findings were evaluated longitudinally at onset and at 12 and 24 months of age. RESULTS: At the onset of West syndrome, MR imaging demonstrated focal signal abnormalities of the subcortical white matter in 2 patients. In the other 2 patients, focal subcortical high-intensity signals became visible on follow-up T2WI as myelination progressed. PET at onset showed focal cortical hypometabolism in 3 patients, with 1 of these patients also having focal hypermetabolism and 1 having normal findings. On PET at 24 months, hypometabolism persisted in 2 patients and disappeared in 1, and hypermetabolism disappeared in 1. In 1 patient with normal MR imaging and PET findings at onset, focal hyperintensity and hypometabolism first appeared at 24 months of age. The findings on MR imaging and PET in these patients evolved differently with brain maturation and the clinical course. CONCLUSIONS: Subtle focal cortical dysplasia can be undetectable on MR imaging at the onset of West syndrome and is not always accompanied by hypometabolism or hypermetabolism on PET. Longitudinal MR imaging and PET studies may be useful for detecting such lesions. Even in West syndrome with a congenital structural abnormality, PET findings evolve differently with brain maturation and the clinical condition.


Asunto(s)
Malformaciones del Desarrollo Cortical/diagnóstico por imagen , Espasmos Infantiles/diagnóstico por imagen , Femenino , Humanos , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Malformaciones del Desarrollo Cortical/patología , Neuroimagen , Tomografía de Emisión de Positrones , Espasmos Infantiles/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
3.
Clin Radiol ; 71(3): 203-10, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26703117

RESUMEN

AIM: To compare the multidetector-row computed tomography (MDCT) findings of IgG4-related sclerosing cholangitis (IgG4-SC) and extrahepatic cholangiocarcinoma (EH-CCA). MATERIALS AND METHODS: Two radiologists who had no knowledge of the patients' clinical information retrospectively evaluated the CT findings of patients with IgG4-SC (n=33) and EH-CCA (n=39) on a consensus basis. Another radiologist measured the biliary lesions. IgG4-SC was diagnosed using the Japan Biliary Association criteria (2012) or the Mayo Clinic's HISORt criteria. EH-CCA was diagnosed based on surgical findings. RESULTS: Compared with EH-CCA, IgG4-SC exhibited the following findings significantly more frequently: (a) wall thickening alone, (b) concentric wall thickening, (c) smooth inner margins, (d) homogeneous attenuation in the arterial phase, (e) a lesion involving the intrapancreatic bile duct, (f) smooth outer margins, (g) fully visible lumen, (h) a funnel-shaped proximal bile duct, (i) skip lesions, and (j) abnormal pancreatic findings. Conversely, (k) dual-layered attenuation in all phases was significantly more common in EH-CCA. The specificity values of parameters (e-k) were >80%. Regarding dimensions, (l) the biliary lesions were longer in IgG4-SC than in EH-CCA. (m) The diameters of the dilated proximal common bile duct and (n) the dilated proximal intrahepatic bile duct were smaller in IgG4-SC than in EH-CCA. CONCLUSION: A number of CT findings are useful for differentiating between IgG4-SC and EH-CCA. CT findings (e-k) are particularly useful for this purpose.


Asunto(s)
Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Extrahepáticos , Colangiocarcinoma/diagnóstico por imagen , Colangitis Esclerosante/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de los Conductos Biliares/inmunología , Neoplasias de los Conductos Biliares/cirugía , Colangiocarcinoma/inmunología , Colangiocarcinoma/cirugía , Colangitis Esclerosante/inmunología , Colangitis Esclerosante/cirugía , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
4.
Br J Radiol ; 87(1042): 20140030, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25117626

RESUMEN

OBJECTIVE: To determine the prevalence and clinical features of pathologically proven incidental cancer (IC) detected by whole-body fluorine-18 fludeoxyglucose ((18)F-FDG) positron emission tomography (PET)/CT, as well as the incidence of false-positive and false-negative results. METHODS: We retrospectively reviewed reports derived from (18)F-FDG PET/CT images of 3079 consecutive patients with known or suspected malignancies for 3 years. Discrete focal uptake indicating IC was identified from reports as well as pathological or clinical diagnoses, and the clinical courses were investigated. The false-positive result was defined as uptake indicating IC but not pathologically confirmed as malignant during follow-up. The false-negative result was defined as pathologically proven IC detected by another modality at initial clinical work-up or diagnosed during the follow-up period. RESULTS: We found (18)F-FDG uptake indicating IC in 6.7% of all patients, and IC was pathologically proven in 2.2% of all patients. The most common sites were the colon, lung and stomach. The median survival duration of patients with IC was 42 months. The results were false positive in 4.5% of all patients, and the results were false negative in 2.3% of all patients. CONCLUSION: (18)F-FDG PET/CT is a valuable tool for detecting IC. The rates of false-positive and false-negative results are within acceptable range. ADVANCES IN KNOWLEDGE: This is the first report to describe the survival of patients with IC, and the detailed features of false-negative results at actual clinical settings.


Asunto(s)
Neoplasias Colorrectales/diagnóstico por imagen , Hallazgos Incidentales , Neoplasias Pulmonares/diagnóstico por imagen , Imagen Multimodal , Tomografía de Emisión de Positrones/métodos , Anciano , Anciano de 80 o más Años , Errores Diagnósticos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos , Estudios Retrospectivos
5.
J Laryngol Otol ; 128(2): 192-4, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24495479

RESUMEN

OBJECTIVE: We report three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging findings in a patient with relapsing polychondritis. METHOD: Case report. RESULT: A 76-year-old woman initially presented with bilateral auricular swelling together with dyspnoea. Three months later, she experienced left hearing loss and recurrent vertigo. A biopsy of the auricle was performed and relapsing polychondritis was diagnosed. The patient underwent three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging 4 hours after intravenous injection of a standard dose of gadolinium. Gadolinium enhancement was visible throughout the vestibule and the endolymphatic space could not be visualised, suggesting breakdown of the blood-labyrinth barrier. CONCLUSION: This is the first radiological report to demonstrate breakdown of the blood-labyrinth barrier in a case of relapsing polychondritis with inner ear impairment.


Asunto(s)
Policondritis Recurrente/diagnóstico , Anciano , Biopsia , Medios de Contraste , Pabellón Auricular/patología , Femenino , Gadolinio , Pérdida Auditiva/etiología , Humanos , Imagen por Resonancia Magnética/métodos , Policondritis Recurrente/complicaciones , Policondritis Recurrente/patología , Vestíbulo del Laberinto/patología
6.
Clin Radiol ; 67(3): 224-31, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21944774

RESUMEN

AIM: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. MATERIALS AND METHODS: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. RESULTS: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20mm (n=32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n=31), not hyperdense during the portal-venous and delayed phases (n=36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n=27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. CONCLUSIONS: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.


Asunto(s)
Adenocarcinoma Mucinoso/diagnóstico por imagen , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares Intrahepáticos/diagnóstico por imagen , Carcinoma Papilar/diagnóstico por imagen , Colangiocarcinoma/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Dilatación Patológica/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Phys Med Biol ; 56(17): 5525-34, 2011 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-21813962

RESUMEN

We aimed to estimate the scattered radiation from dental metallic crowns during head and neck radiotherapy by irradiating a jaw phantom with external photon beams. The phantom was composed of a dental metallic plate and hydroxyapatite embedded in polymethyl methacrylate. We used radiochromic film measurement and Monte Carlo simulation to calculate the radiation dose and dose distribution inside the phantom. To estimate dose variations in scattered radiation under different clinical situations, we altered the incident energy, field size, plate thickness, plate depth and plate material. The simulation results indicated that the dose at the incident side of the metallic dental plate was approximately 140% of that without the plate. The differences between dose distributions calculated with the radiation treatment-planning system (TPS) algorithms and the data simulation, except around the dental metallic plate, were 3% for a 4 MV photon beam. Therefore, we should carefully consider the dose distribution around dental metallic crowns determined by a TPS.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Coronas , Neoplasias de Cabeza y Cuello/radioterapia , Metales/química , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador/métodos , Dispersión de Radiación , Algoritmos , Carcinoma de Células Escamosas/diagnóstico por imagen , Simulación por Computador , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Fotones/uso terapéutico , Dosis de Radiación , Radiografía , Radiometría/métodos , Radioterapia de Alta Energía/efectos adversos , Sensibilidad y Especificidad , Carcinoma de Células Escamosas de Cabeza y Cuello
9.
Clin Radiol ; 65(9): 735-43, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20696301

RESUMEN

AIM: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). MATERIALS AND METHODS: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. RESULTS: The pancreas showed diffuse enlargement (n=16; 32%), focal enlargement (n=18; 36%), or no enlargement (n=16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n=45; 90%) and hyperattenuation during the delayed phase (n=39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n=24; 48%); no visualization of the main pancreatic duct lumen (n=48; 96%); ductal enhancement (n=26; 52%); upstream dilatation of the main pancreatic duct (n=27; 54%); upstream atrophy of the pancreatic parenchyma (n=27; 54%); calcification (n=7; 14%); and cysts (n=5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n=40; 80%); peripancreatic (n=8; 16%) or para-aortic (n=10; 20%) soft-tissue proliferation; and renal involvement (n=15; 30%). CONCLUSION: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.


Asunto(s)
Enfermedades Autoinmunes/diagnóstico por imagen , Medios de Contraste , Pancreatitis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Enfermedades Autoinmunes/patología , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patología , Pancreatitis/patología , Estudios Retrospectivos
11.
Clin Otolaryngol ; 31(2): 110-5, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16620329

RESUMEN

OBJECTIVE: To investigate Schwartze sign with measurements of blood flow to the promontory in patients with cochlear otosclerosis. DESIGN: Prospective clinical study. SETTING: Tertiary referral centre. PARTICIPANTS: Five patients with cochlear otosclerosis and five control subjects. Significant decalcification around the cochlea was observed by computed tomography (CT) in patients with cochlear otosclerosis. However, no recognizable lesion was observed at the oval window in two patients. One patient had mixed hearing loss and four patients had sensorineural hearing loss without an air-bone gap. MAIN OUTCOME MEASURES: The relationship between CT findings and the presence or absence of Schwartze sign was investigated. Blood flow to the promontory was measured through the tympanic membrane using laser speckle flowgraphy and laser Doppler flowmetry. RESULTS: The Schwartze sign correlated significantly with otosclerotic lesions invading the promontory. Patients with otosclerosis exhibited elevated and pulsating blood flow to the promontory with the Schwartze sign. CONCLUSIONS: Computed tomography demonstrated that cochlear otosclerosis can exist without the oval window lesion. Schwartze sign can be used as a sign of the otosclerotic invasion to the promontory. The reddening of the Schwartze sign is likely due to increased blood flow.


Asunto(s)
Cóclea/irrigación sanguínea , Oído Medio/irrigación sanguínea , Otosclerosis/fisiopatología , Adulto , Estudios de Casos y Controles , Cóclea/patología , Oído Medio/patología , Femenino , Humanos , Flujometría por Láser-Doppler , Masculino , Persona de Mediana Edad , Otosclerosis/diagnóstico , Estudios Prospectivos , Flujo Sanguíneo Regional , Tomografía Computarizada por Rayos X
12.
Gene Ther ; 12(24): 1769-77, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16079886

RESUMEN

Immunization involving a DNA vaccine prime followed by an adenovirus type 5 (Ad5) boost elicited a protective immune response against SHIV challenge in monkeys. However, the hepatocellular tropism of Ad5 limits the safety of this viral vector. This study examines the safety and immunogenicity of a replication-defective chimeric Ad5 vector with the Ad35 fiber (Ad5/35) in BALB/c mice and rhesus monkeys. This novel Ad5/35 vector showed minimal hepatotoxicity after intramuscular administration with the novel Ad5/35 vector. In addition, an Ad5/35 vector expressing HIV Env gp160 protein (Ad5/35-HIV) generated strong HIV-specific immune responses in both animal models. Priming with a DNA vaccine followed by Ad5/35-HIV boosting yielded protection against a gp160-expressing vaccinia virus challenge in BALB/c mice. The Ad5/35-HIV vector was significantly less susceptible to the pre-existing Ad5 immunity than a comparable Ad5 vector. These findings indicate that an Ad5/35 vector-based HIV vaccine may be of considerable value for clinical use.


Asunto(s)
Vacunas contra el SIDA/administración & dosificación , Terapia Genética/métodos , Infecciones por VIH/prevención & control , VIH-1 , Inmunización/métodos , Vacunas de ADN/administración & dosificación , Adenoviridae/genética , Animales , Anticuerpos Antivirales/sangre , ADN Viral/administración & dosificación , Femenino , Vectores Genéticos/administración & dosificación , Vectores Genéticos/genética , VIH-1/genética , VIH-1/inmunología , Inmunización Secundaria , Macaca mulatta , Masculino , Ratones , Ratones Endogámicos BALB C , Modelos Animales , Pruebas de Neutralización , Virus Vaccinia/fisiología , Proteínas Virales/genética , Fenómenos Fisiológicos de los Virus
13.
Neuroradiology ; 45(9): 626-30, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12904928

RESUMEN

There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion.


Asunto(s)
Acueducto Coclear/patología , Pérdida Auditiva Sensorineural/etiología , Pérdida Auditiva Sensorineural/patología , Imagen por Resonancia Magnética/métodos , Acúfeno/etiología , Acúfeno/patología , Vértigo/etiología , Vértigo/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador
14.
Hepatogastroenterology ; 48(40): 923-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11490841

RESUMEN

Recent improvements in imaging techniques have made it possible to improve the diagnostic accuracy for detection, staging, and indicating surgical resectability of pancreatic cancer. The latest advance in the computed tomography technique, is the introduction of subsecond multislice helical scanning that improves z-axis resolution in the reformatted images and three-dimensional rendering with a large volume data. Magnetic resonance imaging provides versatile information including magnetic resonance cholangiopancreatography that allows noninvasive delineation of the pancreatic and biliary duct systems. The presence of pancreatic cancer may best be evaluated by dynamic computed tomography or dynamic magnetic resonance imaging with administration of intravenous contrast material. Both computed tomography and magnetic resonance imaging are valuable for the preoperative assessment of local invasion and vascular involvement. Multislice helical computed tomography is currently considered as the best single modality for the diagnosis of pancreatic cancer as it provides excellent image quality. When advanced magnetic resonance imaging equipment is used as a primary modality, in the future, it may have a possibility to replace other imaging modalities.


Asunto(s)
Adenocarcinoma/diagnóstico , Imagen por Resonancia Magnética , Neoplasias Pancreáticas/diagnóstico , Tomografía Computarizada por Rayos X , Adenocarcinoma/diagnóstico por imagen , Humanos , Interpretación de Imagen Asistida por Computador , Invasividad Neoplásica , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología
15.
AJNR Am J Neuroradiol ; 22(6): 1179-85, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11415916

RESUMEN

BACKGROUND AND PURPOSE: MR cisternography has been used as the noninvasive screening tool of the cerebellopontine angle. The purpose of this study was to directly compare two currently dominant types of sequences for heavily T2-weighted MR cisternography. METHODS: Three-dimensional fast asymmetric spin-echo (3D-FASE) sequences, which are 3D half-Fourier rapid acquisition with relaxation enhancement and 3D constructive interference in the steady-state (3D-CISS) sequences, were compared on a clinical 1.5-T MR unit using the same scan times. In five healthy volunteers, the contrast-to-noise ratio (C/N) between CSF and the cerebellum was measured at three locations. Then, for qualitative analysis, the quality of the labyrinth was scored on the original source multiplanar reformatted images, the virtual endoscopic images, and the maximum intensity projection (MIP) images. In 20 consecutive patients with suspected cerebellopontine angle tumors, visualization of the tumors was evaluated using 3D contrast-enhanced spoiled gradient-echo imaging as the standard of reference. RESULTS: Both sequences showed comparable mean C/N values; however, in qualitative analysis, the scores for 3D-CISS on the source, virtual endoscopic, and MIP images were significantly lower than those on the images obtained with 3D-FASE, owing to more prominent flow and magnetic susceptibility artifacts on the 3D-CISS sequences. In all subjects, discontinuity of the semicircular canals was seen on the virtual endoscopic and MIP images obtained with 3D-CISS, owing to susceptibility artifacts, but not on those obtained with 3D-FASE. All 12 tumors were detected by both sequences, but 3D-CISS gave one false-positive result. CONCLUSION: 3D-FASE is considered the method of choice because artifacts are reduced and specificity is increased.


Asunto(s)
Neoplasias Cerebelosas/diagnóstico , Imagen Eco-Planar , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética , Neumoencefalografía , Adulto , Artefactos , Ángulo Pontocerebeloso/patología , Acueducto Coclear/patología , Nervio Coclear/patología , Endoscopía , Femenino , Análisis de Fourier , Humanos , Masculino , Persona de Mediana Edad , Neuroma Acústico/diagnóstico , Valores de Referencia , Sensibilidad y Especificidad , Nervio Trigémino/patología , Interfaz Usuario-Computador
16.
J Magn Reson Imaging ; 13(5): 792-6, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11329203

RESUMEN

Virtual endoscopy (VE) of the labyrinth was performed using three-dimensional (3D)-fast asymmetric spin-echo MR imaging. The spatial resolution requirements and the usefulness of zero-fill interpolation (ZIP) were evaluated, and VE was used to examine three patients. The (0.6-mm) voxel data with ZIP satisfies the minimum requirements for VE for evaluation of the complex 3D anatomy and pathology of the labyrinth. J. Magn. Reson. Imaging 2001;13:792-796.


Asunto(s)
Oído Interno/patología , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética , Otoscopios , Interfaz Usuario-Computador , Adolescente , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Neuroma Acústico/diagnóstico , Valor Predictivo de las Pruebas , Canales Semicirculares/anomalías , Canales Semicirculares/patología , Vestíbulo del Laberinto/patología
17.
Radiat Med ; 18(3): 177-85, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10972548

RESUMEN

PURPOSE: To evaluate the use of endovascular stent-graft placement to repair pseudoaneurysm of the aorta. METHODS: Six patients were treated with stent-grafts for pseudoaneurysms located in the thoracic aorta (n=2), thoracoabdominal aorta (n=3), and abdominal aorta (n=1). Etiologies of the pseudoaneurysms included leakage from surgical graft, penetrating atherosclerotic ulcer, pneumonia, perforated esophageal ulcer, and mycotic aneurysm. All patients were clinically considered to be at high surgical risk. RESULTS: Stent-grafts were successfully placed in all patients. There was one death in the perioperative period due to massive hemoptysis before stent-grafting. Two patients died of persistent infection. One patient with persistent perigraft leak died of rupture. Two other patients needed no further therapy for pseudoaneurysm. CONCLUSION: Stent-graft placement for pseudoaneurysm of the aorta can play the role of a temporizing method prior to surgical repair in high-risk cases and be a therapeutic alternative in cases without infection or perigraft leakage.


Asunto(s)
Aneurisma Falso/terapia , Aneurisma de la Aorta/terapia , Radiografía Intervencional , Stents , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/etiología , Femenino , Humanos , Masculino
18.
Radiat Med ; 18(3): 187-91, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10972549

RESUMEN

Arachnoid granulations (AGs), protrusions into the cerebral venous sinus lumen, have been reported on cerebral venography, contrast enhanced CT, and conventional MR imaging. Although thin-sliced high-resolution MR images and diffusion-weighted images are frequently obtained, there have been no detailed reports concerning AGs on these images. In this study, the frequency and positional distribution of AGs in the transverse sinus was investigated on thin-sliced high-resolution MR images, and their appearance on diffusion-weighted MR images was evaluated. At least one AG was found in 107 of 151 subjects (70.9%). No statistically significant differences were noticed between males and females or between the right and left sides. No significant correlations between age and size or between age and the number of AGs were noted. On diffusion-weighted images, all AGs showed iso-intensity to normal brain tissue, which was higher than the reported signal intensity of arachnoid cyst and lower than that of epidermoids. In conclusion, AGs are normal structures that are frequently found in the cerebral venous sinuses on high-resolution MR images. Knowledge regarding their frequency and normal appearance would be helpful to avoid confusion between pathological processes and AGs. It is also important to know that AGs are frequently found even in the younger population.


Asunto(s)
Aracnoides/anatomía & histología , Senos Craneales/anatomía & histología , Tejido de Granulación/anatomía & histología , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Aracnoides/patología , Niño , Senos Craneales/patología , Diagnóstico Diferencial , Femenino , Tejido de Granulación/patología , Humanos , Enfermedades del Laberinto/patología , Masculino , Persona de Mediana Edad , Valores de Referencia
19.
Radiat Med ; 18(1): 71-9, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10852660

RESUMEN

A real-time interactive MR imaging system (real-time MRI) is an MR scanner which has a fast image updating cycle and the ability to freely change slice orientation, just like an ultrasound imaging system. Recently, such a system has been developed and installed on a clinical 1.5-Tesla system. The purpose of this study was to optimize the pulse sequences for clinical use and to evaluate the clinical usefulness and basic functionality of real-time MRI. For T1-weighted imaging, FLASH (fast low angle shot) can be selected, and up to 5 frames per second can be acquired depending on the matrix size. For T2-weighted imaging, true FISP (fast imaging with steady-state precession) can be selected, and up to 4 frames per second can be acquired. Maximum C/N between liver and spleen was obtained at a flip angle of 20 degrees on FLASH. Maximum C/N between cardiac cavity and wall was obtained at a flip angle of 60 degrees on true FISP. Localization of the right and left coronary arteries could be performed within 30 seconds in three volunteers. Although the present real-time MRI system has drawbacks such as low spatial resolution and relatively low contrast resolution, we expect real-time MRI to be one of the most important tools for future clinical MRI.


Asunto(s)
Sistemas de Computación , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Artefactos , Carcinoma Hepatocelular/diagnóstico , Medios de Contraste , Vasos Coronarios/anatomía & histología , Deglución/fisiología , Diseño de Equipo , Estudios de Evaluación como Asunto , Movimientos Oculares/fisiología , Corazón/anatomía & histología , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/instrumentación , Hígado/anatomía & histología , Neoplasias Hepáticas/diagnóstico , Angiografía por Resonancia Magnética/instrumentación , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/instrumentación , Masculino , Fracturas Orbitales/fisiopatología , Procesamiento de Señales Asistido por Computador , Bazo/anatomía & histología , Vejiga Urinaria/fisiología , Micción/fisiología
20.
AJNR Am J Neuroradiol ; 20(6): 1143-7, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10445459

RESUMEN

High-resolution MR cisternography performed with 3D fast asymmetric spin-echo imaging (3D fast spin-echo with an ultra-long echo train length and asymmetric Fourier imaging) was optimized in a 0.35-T open MR imaging unit. The 0.35- and 1.5-T images of the two volunteers and three patients with acoustic schwannomas were then compared. The optimal parameters for images obtained by 3D fast asymmetric spin-echo imaging at 0.35 T were as follows: field of view, 15 cm; matrix, 256 x 256 x 40; section thickness, 1 mm; echo train length, 76; and imaging time, 10 minutes 44 seconds. Scans obtained from both normal volunteers showed the facial, cochlear, and superior and inferior vestibular nerves separately in the internal auditory canal on both 0.35- and 1.5-T images. All three acoustic schwannomas were depicted on both 0.35- and 1.5-T images. Screening for disease at the cerebellopontine angle and in the internal auditory canal, without the administration of contrast material on a low-field open MR imaging unit and within a clinically acceptable imaging time, may be possible. Further controlled prospective studies are required, however, before implementation on a wide basis. If proved effective, this may be of particular value for reducing healthcare costs and for imaging claustrophobic and pediatric patients in an open system.


Asunto(s)
Cisterna Magna/patología , Imagen por Resonancia Magnética , Neuroma Acústico/diagnóstico , Ángulo Pontocerebeloso , Oído Interno/patología , Humanos , Imagen por Resonancia Magnética/métodos , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA