Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
2.
Front Cardiovasc Med ; 9: 952255, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36148066

RESUMEN

Background: Mechanical heart valves (MHVs) are preferred prosthesis types in many, especially younger patients who need surgical valve replacement. Although echocardiography is most frequently performed for prosthesis assessment during follow-up, ultrasound artifacts usually preclude a precise investigation of prosthesis function. Cinefluoroscopy (CF) is a simple and effective method to analyze and quantify opening and closing of prosthesis leaflets but requires careful visualization of the valve using optimal viewing angles. Here, we investigated the quality of CF studies in clinical routine and their suitability for quantitative analysis of prosthesis function. Methods and results: We retrospectively identified 94 patients with 118 cinefluoroscopies performed by 31 different investigators in one tertiary center from 2012 to 2021. Of 150 MHVs (98% bi-leaflet prostheses), 87 (58%) were aortic, 53 (34%) mitral, 7 (5%) tricuspid, and 5 (3%) pulmonary valve prostheses, respectively. CF studies were categorized by their suitability to quantitatively assess opening and closing angles. Visualization of valve function was "sufficient" in 23%, "suboptimal" in 46%, and "unsuitable" in 31% of the cases. Conclusion: In clinical routine, only one-fourth of CF studies allow for a complete assessment of leaflet motion of MHVs. Although this may be in part due to the varying experience of operators, the high number of unsuitable studies suggests that optimal viewing angles may not be achievable in all patients. Further research is required to investigate standard viewing angles and anatomy after MHV implantation to improve the quality of CF studies and reduce radiation exposure of patients and operators.

3.
Internist (Berl) ; 63(5): 545-550, 2022 May.
Artículo en Alemán | MEDLINE | ID: mdl-35195756

RESUMEN

Here, we report on a patient with deep vein thrombosis of the right leg, in whom diagnostic work-up revealed a previously unknown chondrosarcoma of the tibia. Physical examination revealed a firm, nondisplaceable mass on the dorsal side of the right knee that appeared as a cystic formation on ultrasound. X­ray, computed tomography, and magnetic resonance imaging were consistent with chondrosarcoma, which had likely provoked the thrombosis by local compression or paraneoplastic mechanisms. After resection of the tumor, anticoagulation was continued. In a review of all findings, a final diagnosis of highly differentiated chondrosarcoma with thrombosis of the popliteal vein was made.


Asunto(s)
Neoplasias Óseas , Condrosarcoma , Trombosis , Trombosis de la Vena , Neoplasias Óseas/complicaciones , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/cirugía , Humanos , Ultrasonografía/métodos , Trombosis de la Vena/diagnóstico , Trombosis de la Vena/etiología
4.
JACC Cardiovasc Interv ; 15(3): 297-304, 2022 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-35144785

RESUMEN

OBJECTIVES: This study sought to evaluate the differences in cardiogenic shock patient characteristics in trial patients and real-life patients. BACKGROUND: Cardiogenic shock (CS) is a leading cause of mortality in patients presenting with acute myocardial infarction (AMI). However, the enrollment of patients into clinical trials is challenging and may not be representative of real-world patients. METHODS: We performed a systematic review of studies in patients presenting with AMI-related CS and compared patient characteristics of those enrolled into randomized controlled trials (RCTs) with those in registries. RESULTS: We included 14 RCTs (n = 2,154) and 12 registries (n = 133,617). RCTs included more men (73% vs 67.7%, P < 0.001) compared with registries. Patients enrolled in RCTs had fewer comorbidities, including less hypertension (61.6% vs 65.9%, P < 0.001), dyslipidemia (36.4% vs 53.6%, P < 0.001), a history of stroke or transient ischemic attack (7.1% vs 10.7%, P < 0.001), and prior coronary artery bypass graft surgery (5.4% vs 7.5%, P < 0.001). Patients enrolled in RCTs also had lower lactate levels (4.7 ± 2.3 mmol/L vs 5.9 ± 1.9 mmol/L, P < 0.001) and higher mean arterial pressure (73.0 ± 8.8 mm Hg vs 62.5 ± 12.2 mm Hg, P < 0.001). Percutaneous coronary intervention (97.5% vs 58.4%, P < 0.001) and extracorporeal membrane oxygenation (11.6% vs 3.4%, P < 0.001) were used more often in RCTs. The in-hospital mortality (23.9% vs 38.4%, P < 0.001) and 30-day mortality (39.9% vs 45.9%, P < 0.001) were lower in RCT patients. CONCLUSIONS: RCTs in AMI-related CS tend to enroll fewer women and lower-risk patients compared with registries. Patients enrolled in RCTs are more likely to receive aggressive treatment with percutaneous coronary intervention and extracorporeal membrane oxygenation and have lower in-hospital and 30-day mortality.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Infarto del Miocardio , Intervención Coronaria Percutánea , Oxigenación por Membrana Extracorpórea/efectos adversos , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
5.
Artif Organs ; 45(10): 1240-1249, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34152637

RESUMEN

Extracorporeal membrane oxygenation (ECMO) is frequently used in many centers around the globe for various indications. However, prognosis is often poor even with all supportive therapies, and in many cases, clinical deterioration is associated with inflammation. Hemoadsorption with CytoSorb is a novel approach to limit the inflammatory response, and the device can be safely and easily installed into ECMO circuits. CytoSorb has been used more than 130.000 times to date, but because randomized controlled trials are largely lacking, there is substantial debate on its use. Here, experts from critical care medicine, cardiology, cardiac surgery, and perfusion technology discuss the pros and cons of this novel therapy and outline the future aspects for its clinical application and research.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Hemofiltración/instrumentación , Absorción Fisicoquímica , Oxigenación por Membrana Extracorpórea/efectos adversos , Hemofiltración/métodos , Humanos , Inflamación
6.
Ann Cardiothorac Surg ; 10(2): 255-267, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33842220

RESUMEN

BACKGROUND: Worse outcomes in women compared to men undergoing left ventricular assist device (LVAD) implantation remain an underestimated problem in heart failure (HF) patients. With device miniaturization, less-invasive LVAD implantation techniques have gained relevance, but their impact on outcomes in women is unknown. This study investigates sex-related differences in patients undergoing LVAD implantation through less-invasive procedures. METHODS: This retrospective single-center cohort study included patients who underwent isolated LVAD implantation between 2011 and 2018 through less-invasive techniques. Propensity score matching (PSM) was utilized to balance preoperative heterogeneity. Primary endpoint was two-year survival, and secondary endpoints included long-term survival, surgical outcomes and postoperative adverse events. RESULTS: Baseline analysis of 191 patients (females 18.3%) showed differences in terms of age [female (median, 52; IQR, 47-61); male (median, 58.5; IQR, 49-66); P=0.005], underlying diagnosis (P<0.001), INTERMACS profile (P=0.009), history of previous cardiac surgery (P=0.049) and preoperative creatinine values [female (median, 110; IQR, 71-146); male (median, 126; IQR, 9-168); P=0.049]. Over a follow-up of 460.68 patient-years, Kaplan-Meyer analysis showed better survival in females (P=0.027) and a similar probability of cardiac transplantation (P=0.288). After PSM, females showed higher needs for intraoperative fresh frozen plasma (P=0.044) and platelets (P=0.001) but comparable postoperative outcomes. No sex-related differences were noticed regarding two-year outcomes, long-term survival and adverse events. LVAD-related infections remained the most common complication with males experiencing more pump infections than women (P=0.050). CONCLUSIONS: Patients receiving less-invasive LVAD implantation do not show significant sex-related differences in short and long-term outcomes and survival. Prospective studies are needed to evaluate the role of less-invasive techniques in reducing sex-based disparities after LVAD implantation.

8.
Cardiovasc Revasc Med ; 28S: 189-192, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32950404

RESUMEN

Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, and available devices and surgical techniques have strongly evolved over time. Adequate recompensation of patients before surgery is important for optimal surgical outcomes. However, patients with terminal heart failure frequently suffer from cardiorenal syndrome, which complicates recompensation by medical means. Here, we report on the use of an Impella 5.5 microaxial pump for supporting a patient with severely decompensated heart failure before LVAD implantation, which resulted in hemodynamic stabilization and effective recompensation prior to surgery.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos
10.
J Am Heart Assoc ; 8(15): e010881, 2019 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-31311438

RESUMEN

Background Clinical characteristics and outcomes of takotsubo syndrome (TTS) patients with malignancy have not been fully elucidated. This study sought to explore differences in clinical characteristics and to investigate short- and long-term outcomes in TTS patients with or without malignancy. Methods and Results TTS patients were enrolled from the International Takotsubo Registry. The TTS cohort was divided into patients with and without malignancy to investigate differences in clinical characteristics and to assess short- and long-term mortality. A subanalysis was performed comparing long-term mortality between a subset of TTS patients with or without malignancy and acute coronary syndrome (ACS) patients with or without malignancy. Malignancy was observed in 16.6% of 1604 TTS patients. Patients with malignancy were older and more likely to have physical triggers, but less likely to have emotional triggers compared with those without malignancy. Long-term mortality was higher in patients with malignancy (P<0.001), while short-term outcome was comparable (P=0.17). In a subanalysis, long-term mortality was comparable between TTS patients with malignancies and ACS patients with malignancies (P=0.13). Malignancy emerged as an independent predictor of long-term mortality. Conclusions A substantial number of TTS patients show an association with malignancy. History of malignancy might increase the risk for TTS, and therefore, appropriate screening for malignancy should be considered in these patients. Clinical Trial Registration URL: http://www.clinicaltrial.gov. Unique identifier: NCT01947621.


Asunto(s)
Neoplasias/diagnóstico , Neoplasias/mortalidad , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/mortalidad , Anciano , Femenino , Humanos , Cooperación Internacional , Masculino , Persona de Mediana Edad , Neoplasias/complicaciones , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Cardiomiopatía de Takotsubo/complicaciones , Factores de Tiempo
11.
Cardiovasc Revasc Med ; 20(9): 827-828, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30651215

RESUMEN

Mechanical circulatory support with the Impella pump is established in many centers treating patients with cardiogenic shock. While Impella pumps usually run very stable, it may still be possible that one needs to remove the pump for using the same vascular access for different reasons. Unfortunately, until now it had been nearly impossible to remove the pump while preserving arterial access without severe bleeding. Here we describe a prototypical approach of exchanging an Impella pump in a 47-year-old female supported with veno-arterial ECMO for cardiogenic shock from myocarditis. The dysfunctional Impella pump was safely removed and replaced by a new one through the same arterial access site. Continuation of active LV unloading resolved pulmonary edema, and the patient was finally bridged to ventricular assist device surgery with favorable outcome. In general, the described approach is applicable for virtually all large-bore devices with arterial access.


Asunto(s)
Cateterismo Periférico , Remoción de Dispositivos , Arteria Femoral , Corazón Auxiliar , Falla de Prótesis , Implantación de Prótesis/instrumentación , Choque Cardiogénico/terapia , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Punciones , Recuperación de la Función , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/fisiopatología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología
12.
Thorac Cardiovasc Surg Rep ; 7(1): e30-e32, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29977736

RESUMEN

Background A rupture of the free wall of the left ventricle is a rarely seen complication of myocardial infarction and represents an absolute cardiac emergency. Case Description We hereby present a case of a 64-year-old patient with a rupture of the free left ventricular wall. The patient was treated in an emergent operation with a novel reconstruction method of the left ventricular wall and was discharged 30 days after the initial operation. Conclusion Left ventricular free wall rupture is rarely described in the literature, which might be because of high mortality in underdiagnosed cases. Therefore, early imaging by echo or computed tomography (CT) is essential for detecting this dangerous condition. Once diagnosed, urgent surgery is mandatory to save the life of the patient.

13.
Eur J Nucl Med Mol Imaging ; 45(11): 1934-1944, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29967943

RESUMEN

PURPOSE: The chemokine receptor CXCR4 is a promising target for molecular imaging of CXCR4+ cell types, e.g. inflammatory cells, in cardiovascular diseases. We speculated that a specific CXCR4 ligand, [68Ga]pentixafor, along with novel techniques for motion correction, would facilitate the in vivo characterization of CXCR4 expression in small culprit and nonculprit coronary atherosclerotic lesions after acute myocardial infarction by motion-corrected targeted PET/CT. METHODS: CXCR4 expression was analysed ex vivo in separately obtained arterial wall specimens. [68Ga]Pentixafor PET/CT was performed in 37 patients after stent-based reperfusion for a first acute ST-segment elevation myocardial infarction. List-mode PET data were reconstructed to five different datasets using cardiac and/or respiratory gating. Guided by CT for localization, the PET signals of culprit and various groups of nonculprit coronary lesions were analysed and compared. RESULTS: Ex vivo, CXCR4 was upregulated in atherosclerotic lesions, and mainly colocalized with CD68+ inflammatory cells. In vivo, elevated CXCR4 expression was detected in culprit and nonculprit lesions, and the strongest CXCR4 PET signal (median SUVmax 1.96; interquartile range, IQR, 1.55-2.31) was observed in culprit coronary artery lesions. Stented nonculprit lesions (median SUVmax 1.45, IQR 1.23-1.88; P = 0.048) and hot spots in naive remote coronary segments (median SUVmax 1.34, IQR 1.23-1.74; P = 0.0005) showed significantly lower levels of CXCR4 expression. Dual cardiac/respiratory gating provided the strongest CXCR4 PET signal and the highest lesion detectability. CONCLUSION: We demonstrated the basic feasibility of motion-corrected targeted PET/CT imaging of CXCR4 expression in coronary artery lesions, which was triggered by vessel wall inflammation but also by stent-induced injury. This novel methodology may serve as a platform for future diagnostic and therapeutic clinical studies targeting the biology of coronary atherosclerotic plaque.


Asunto(s)
Complejos de Coordinación , Regulación Neoplásica de la Expresión Génica , Movimiento , Péptidos Cíclicos , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Receptores CXCR4/metabolismo , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/fisiopatología , Respiración , Estudios Retrospectivos
14.
J Thorac Dis ; 10(Suppl 15): S1696-S1702, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30034841

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) (HVAD, Medtronic, Minneapolis, MN, USA) implantation is already a widely accepted treatment option for end-stage heart failure (HF) but also still considered as a rescue therapy for patients suffering from cardiogenic shock. Standard LVAD implantation techniques are often associated with high mortality rates and can result in severe complications, like bleeding or right heart failure (RHF). The aim of our study was to assess the outcome of Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 1 patients (so called "crash and burn" patients) undergoing a LVAD implantation by standard or less invasive surgery. METHODS: We performed a retrospective evaluation of the 1-year outcome of 32 consecutive HF patients in cardiogenic shock, who underwent LVAD implantation in our institution. A total of 32 INTERMACS 1 patients were emergently operated. Fourteen patients (group A) were operated by using the "Hannover-VAD-technique", which is widely known to be less invasive (upper hemisternotomy and a left-sided anterolateral thoracotomy). In contrast, 18 patients (group B) were implanted with LVAD by using the standard technique (full sternotomy). The primary endpoint was survival after 1 year without device-related re-operations. Secondary endpoints included combined analyses of rates of RHF, respiratory failure and bleeding during the trial period. RESULTS: Baseline characteristics were similar in both groups. Survival after 1 year was higher in group A (69.7% vs. 50.0%). Technique-related adverse events (AEs) were also lower in the minimally invasive group, including a lower RHF (35.7% vs. 61.1%) and of further postoperative bleeding requiring surgery (14.3% vs. 33.3%). CONCLUSIONS: LVAD surgery in INTERMACS 1 patients is associated with remarkably good outcome considering the already very high mortality of those patients, and compared to previously reported surgical outcomes. Our study indicates that minimally invasive LVAD implantation in cardiogenic shock decreases mortality and the incidence of postoperative AEs.

15.
Semin Thorac Cardiovasc Surg ; 30(1): 1-6, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29366876

RESUMEN

For several years, the standard implantation strategy of ventricular assist devices has involved a full sternotomy approach. However, less invasive implantation techniques are now becoming increasingly popular as they are associated with reduction of trauma, blood loss, and arrhythmogenic complications, as well as a decreased duration of intensive care unit and in-hospital stay. Thus, due to miniaturization and increasing technical improvement of ventricular assist devices, less invasive strategies for implantation, explantation, exchange, and concomitant cardiac procedures are on the rise. In this review article, we report on the state of the art of less invasive techniques for implantation, explantation, exchange, and combined cardiac procedures of ventricular assist devices.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Miniaturización , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/mortalidad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Implantación de Prótesis/mortalidad , Recuperación de la Función , Factores de Riesgo , Resultado del Tratamiento
17.
Nat Commun ; 8(1): 952, 2017 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-29038527

RESUMEN

Ischemia causes an inflammatory response that is intended to restore perfusion and homeostasis yet often aggravates damage. Here we show, using conditional genetic deletion strategies together with adoptive cell transfer experiments in a mouse model of hind limb ischemia, that blood vessels control macrophage differentiation and maturation from recruited monocytes via Notch signaling, which in turn promotes arteriogenesis and tissue repair. Macrophage maturation is controlled by Notch ligand Dll1 expressed in vascular endothelial cells of arteries and requires macrophage canonical Notch signaling via Rbpj, which simultaneously suppresses an inflammatory macrophage fate. Conversely, conditional mutant mice lacking Dll1 or Rbpj show proliferation and transient accumulation of inflammatory macrophages, which antagonizes arteriogenesis and tissue repair. Furthermore, the effects of Notch are sufficient to generate mature macrophages from monocytes ex vivo that display a stable anti-inflammatory phenotype when challenged with pro-inflammatory stimuli. Thus, angiocrine Notch signaling fosters macrophage maturation during ischemia.Molecular mechanisms of macrophage-mediated regulation of artery growth in response to ischemia are poorly understood. Here the authors show that vascular endothelium controls macrophage maturation and differentiation via Notch signaling, which in turn promotes arteriogenesis and ischemic tissue recovery.


Asunto(s)
Vasos Sanguíneos/fisiología , Diferenciación Celular/fisiología , Proteína de Unión a la Señal Recombinante J de las Inmunoglobulinas/genética , Péptidos y Proteínas de Señalización Intercelular/genética , Isquemia/genética , Macrófagos/metabolismo , Neovascularización Fisiológica/genética , Traslado Adoptivo , Animales , Proteínas de Unión al Calcio , Eliminación de Gen , Miembro Posterior/irrigación sanguínea , Ratones , Mutación , Receptores Notch , Transducción de Señal
19.
Eur J Cardiothorac Surg ; 51(5): 887-892, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28329060

RESUMEN

OBJECTIVES: Left ventricular assist device (LVAD) exchange is becoming a standard surgical procedure. The exchange procedure is an opportunity to upgrade patients to a new generation pump that offers advanced reduction of adverse events or longer battery hours. METHODS: We performed an analysis of 6 consecutive patients who underwent LVAD exchange to HeartMate 3 either from a HeartWare or HeartMate (HM) II device. Minimally invasive operations were performed through a lateral thoracotomy. Follow-up time was 6 months after LVAD exchange. RESULTS: We present 4 patients with the HM II and 2 patients with the HeartWare ventricular assist device (HVAD) who underwent LVAD exchange to HM III. The average age was 57.5 years. At the time of the LVAD exchange, all patients were classified as Interagency Registry for Mechanically Assisted Circulatory Support level 3. In 5 cases, LVAD infection led to LVAD exchange (83%, 5/6). The remaining patient underwent LVAD exchange due to pump thrombosis (16%, 1/6). The 6-month survival rate after LVAD exchange was 100% (6/6). None of the patients was postoperatively supported by extracorporeal membrane oxygenation. No patient experienced postoperative relevant bleeding. One patient suffered minor cerebral bleeding (16.6%, 1/6). At the 6-month follow-up examination, 1 patient reported a single syncope and several low-flow alarms (1/6). The remaining 5 patients showed no adverse events or technical malfunctions of the VAD (5/6). CONCLUSIONS: LVAD exchanges from HM II as well from HVAD to HM 3 are proven to be technically feasible. Due to the advantages and technical improvements of the new-generation pumps, this procedure is an excellent opportunity to give patients access to a superior generation of assist device.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Corazón Auxiliar , Reoperación , Adulto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/estadística & datos numéricos , Complicaciones Posoperatorias , Reoperación/efectos adversos , Reoperación/instrumentación , Reoperación/estadística & datos numéricos , Trombosis
20.
Thromb Haemost ; 117(1): 99-104, 2017 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-27734075

RESUMEN

Prasugrel, a potent thienopyridine, achieves stronger inhibition of platelet activation than clopidogrel. However, onset of inhibition is significantly delayed in patients with acute ST-elevation myocardial infarction (STEMI), as haemodynamic instability and morphine application seem to exhibit significant influence. Since rapid onset of effect was demonstrated in non-STEMI patients when prasugrel was administered only after percutaneous coronary intervention (PCI) without increasing cardiovascular event rates we assessed the efficacy of prasugrel loading immediately after PCI for STEMI instead of pre-loading before revascularisation. We investigated 50 consecutive patients with acute STEMI (mean age 56 ± 10 years) admitted for primary PCI. Prasugrel efficacy was assessed by platelet reactivity index (PRI; VASP assay) before, 1, 2, 4, 6, 12, and 24 hours following an oral loading dose of 60 mg immediately after PCI. High on-treatment platelet reactivity (HTPR) was defined as PRI>50 %. Prasugrel significantly and rapidly reduced platelet reactivity in acute STEMI patients (p<0.0001 at each time point vs control). Morphine application resulted in a significantly higher HTPR rate among patients having received morphine less than 1 hour before prasugrel loading (p<0.001) while concomitant metoclopramide (MCP) treatment did not significantly affect prasugrel efficacy. In conclusion, in contrast to previous reports describing a significant delay in onset of prasugrel-mediated P2Y12 inhibition in acute STEMI, we observed a rapid onset with low HTPR rates comparable to those observed in stable non-STEMI patients. Prasugrel administered directly after primary PCI might therefore be a useful therapeutic strategy in patients with STEMI to provide strong and effective P2Y12 inhibition.


Asunto(s)
Plaquetas/efectos de los fármacos , Intervención Coronaria Percutánea , Activación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Clorhidrato de Prasugrel/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Infarto del Miocardio con Elevación del ST/terapia , Administración Oral , Anciano , Analgésicos Opioides/uso terapéutico , Plaquetas/metabolismo , Antagonistas de los Receptores de Dopamina D2/uso terapéutico , Esquema de Medicación , Femenino , Humanos , Masculino , Metoclopramida/uso terapéutico , Persona de Mediana Edad , Morfina/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Pruebas de Función Plaquetaria , Clorhidrato de Prasugrel/efectos adversos , Estudios Prospectivos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Receptores Purinérgicos P2Y12/sangre , Receptores Purinérgicos P2Y12/efectos de los fármacos , Infarto del Miocardio con Elevación del ST/sangre , Infarto del Miocardio con Elevación del ST/diagnóstico , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA