Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Knee ; 46: 99-107, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38070382

RESUMEN

BACKGROUND: Uncemented trabecular metal (TM) monoblock tibial components in total knee arthroplasty (TKA) have shown excellent clinical results for up to 10 years. However, these studies were performed in highly specialized units, with few surgeons and often excluding knees with secondary osteoarthritis (OA), severe malalignments and previous surgery. The purpose of this study was to investigate implant survivorship and clinical and radiological outcome of the uncemented TM high-flex posterior stabilized (PS) monoblock tibial component in routine clinical practice. METHODS: A retrospective study of 339 knees (282 patients) operated with the implant in routine clinical practice at two hospitals on patients aged 60 years or younger between 2007 and 2015. The operations were performed by 12 surgeons and there were no specific contraindications for use of the implant. Follow up ended in 2020. The status of the implant of deceased patients at death and those not attending follow up was checked with the Swedish Knee Arthroplasty Register. Clinical follow up consisted of clinical investigation, PROMs, and knee X-ray. RESULTS: Follow up was mean (range) 8.5 (5-13.8) years, and the 8-year survival rate was 0.98 (standard error 0.007). Five patients five knees) were deceased, five knees were revised (none due to aseptic loosening), and 16 patients did not attend the clinical follow up. Forty-four percent of the knees had secondary OA and 45% had had previous operations. 93% were satisfied or very satisfied with the operation and forgotten joint score (FJS) was median (interquartile range) 81 (44-94). Radiographic analysis revealed bone in close contact with the tibial tray and pegs in most cases, and in only 2% of the knees were potential radiolucent lines found. CONCLUSION: The results indicate that this uncemented implant performs excellently in routine clinical practice and also in younger patients with secondary OA or previous knee operations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Resultado del Tratamiento , Estudios Retrospectivos , Estudios de Seguimiento , Reoperación , Falla de Prótesis , Diseño de Prótesis , Metales , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía
2.
Acta Orthop ; 93: 158-163, 2022 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-34984472

RESUMEN

Background and purpose - Knowing how to interpret values obtained with patient reported outcome measures (PROMs) is essential. We estimated the substantial clinical benefit (SCB) and patient acceptable symptom state (PASS) for Forgotten Joint Score 12 (FJS) and explored differences depending on methods used for the estimates. Patients and methods - The study was based on 195 knee arthroplasties (KA) performed at a university hospital. We used 1 item from the Knee injury and Osteoarthritis Outcome Score domain quality of life and satisfaction with surgery, obtained 1-year postoperatively, to assess SCB and PASS thresholds of the FJS with anchor-based methods. We used different combinations of anchor questions for SCB and PASS (satisfied, satisfied with no or mild knee difficulties, and satisfied with no knee difficulties). A novel predictive approach and receiver-operating characteristics curve were applied for the estimates. Results - 70 and 113 KAs were available for the SCB and PASS estimates, respectively. Depending on method, SCB of the FJS (range 0-100) was 28 (95% CI 21-35) and 22 (12-45) respectively. PASS was 31 (2-39) and 20 (10-29) for satisfied patients, 40 (31-47) and 38 (32-43) for satisfied patients with no/mild difficulties, and 76 (39-80) and 64 (55-74) for satisfied patients with no difficulties. The areas under the curve ranged from 0.82 to 0.88. Interpretation - Both the SCB and PASS thresholds varied depending on methodology. This may indicate a problem using meaningful values from other studies defining outcomes after KA. This study supports the premise of the FJS as a PROM with good discriminatory ability in patients undergoing KA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Traumatismos de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente , Calidad de Vida , Resultado del Tratamiento
3.
J Orthop Res ; 40(7): 1604-1612, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34664319

RESUMEN

Polymorphisms in VEGFA and KDR encoding proteins have been associated with anterior cruciate ligament (ACL) injury risk. We leveraged a collective sample from Sweden, Poland, and Australia to investigate the association of functional polymorphisms in VEGFA and KDR with susceptibility to ACL injury risk. Using a case-control genetic association approach, polymorphisms in VEGFA and KDR were genotyped and haplotypes inferred from 765 controls, and 912 cases clinically diagnosed with ACL rupture. For VEGFA, there was a significant overrepresentation of the rs2010963 CC genotype (p = 0.0001, false discovery rate [FDR]: p = 0.001, odds ratio [OR]: 2.16, 95% confidence interval [CI]: 1.47-3.19) in the combined ACL group (18%) compared to the combined control group (11%). The VEGFA (rs699947 C/A, rs1570360 G/A, rs2010963 G/C) A-A-G haplotype was significantly (p = 0.010, OR: 0.85, 95% CI: 0.69-1.05) underrepresented in the combined ACL group (23%) compared to the combined control group (28%). In addition, the A-G-G construct was significantly (p = 0.036, OR: 0.81, 95% CI: 0.64-1.02) underrepresented in the combined ACL group (12%) compared to the combined CON group (16%). Our findings support the association of the VEGFA rs2010963 CC genotype with increased risk and (ii) the VEGFA A-A-G haplotype with a reduced risk, and are in alignment with the a priori hypothesis. Collectively identifying a genetic interval within VEGFA to be implicated in ACL risk modulation and highlight further the importance of vascular regulation in ligament biology.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Factor A de Crecimiento Endotelial Vascular , Lesiones del Ligamento Cruzado Anterior/genética , Estudios de Casos y Controles , Frecuencia de los Genes , Genotipo , Haplotipos , Humanos , Polimorfismo de Nucleótido Simple , Factor A de Crecimiento Endotelial Vascular/genética
4.
J Bone Joint Surg Am ; 103(12): 1115-1124, 2021 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-33886528

RESUMEN

BACKGROUND: Radiostereometric analysis (RSA) is a highly accurate tool to detect implant migration and predict loosening following total knee arthroplasty (TKA). However, little is known about the predisposing risk factors for implant migration, nor which migration profile should be considered physiological (i.e., merely part of an implant-settling phase) and which should be considered pathological (i.e., having a high probability for implant loosening). By pooling individual participant data from long-term follow-up RSA studies, we aimed to identify predisposing risk factors for tibial component loosening. METHODS: Individual data were collected for 630 patients from 11 RSA studies. The repeated measurements were analyzed with use of a linear mixed-effects model, determining the effect of age, sex, body mass index, diagnosis, preoperative and postoperative limb alignment, and prosthesis characteristics on tibial component migration over time, taking into account the clustering of patients within studies. RESULTS: High initial migration was found to result in early mechanical loosening in 18 cases (2.9%) and septic loosening in 2 cases (0.3%), whereas stabilization of high initial migration occurred in 17 cases (2.7%). Late loosening occurred in 13 cases (2.1%). All other 580 cases (92.1%) showed early stabilization and remained stable over time. Mixed-effects model analyses showed that for cemented prostheses, sex, diagnosis, and posterior cruciate ligament type had an effect on migration, but these differences were nonsignificant when analyzing migration from 3 months onwards. Uncemented prostheses aligned in varus showed more migration than neutrally and valgus-aligned TKAs (p = 0.031), and this difference increased over time (p < 0.001). Significantly higher migration was observed following uncemented TKA without an osseointegration-promoting surface (p < 0.001). CONCLUSIONS: For cemented prostheses, increased migration during the first 3 postoperative months was observed for female patients, patients with rheumatoid arthritis, and patients who underwent a posterior-stabilized TKA. For uncemented prostheses, both postoperative varus alignment of the lower limb and the absence of an osseointegration-promoting surface significantly increased postoperative tibial component migration. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Falla de Prótesis , Estudios de Seguimiento , Humanos , Osteoartritis de la Rodilla/cirugía , Análisis Radioestereométrico , Factores de Riesgo , Tibia , Factores de Tiempo
5.
J Sci Med Sport ; 22(11): 1219-1225, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31395468

RESUMEN

OBJECTIVES: To investigate the functional effect of genetic polymorphisms of the inflammatory pathway on structural extracellular matrix components (ECM) and the susceptibility to an anterior cruciate ligament (ACL) injury. DESIGN: Laboratory study, case-control study. METHODS: Eight healthy participants were genotyped for interleukin (IL)1B rs16944 C>T and IL6 rs1800795 G>C and classified into genetic risk profile groups. Differences in type I collagen (COL1A1), type V collagen (COL5A1), biglycan (BGN) and decorin (DCN) gene expression were measured in fibroblasts either unstimulated or following IL-1ß, IL-6 or tumor necrosis factor (TNF)-α treatment. Moreover, a genetic association study was conducted in: (i) a Swedish cohort comprised of 116 asymptomatic controls (CON) and 79 ACL ruptures and (ii) a South African cohort of 100 CONs and 98 ACLs. Participants were genotyped for COL5A1 rs12722 C>T, IL1B rs16944 C>T, IL6 rs1800795 G>C and IL6R rs2228145 G>C. RESULTS: IL1B high-risk fibroblasts had decreased BGN (p=0.020) and COL5A1 (p=0.012) levels after IL-1ß stimulation and expressed less COL5A1 (p=0.042) following TNF-α treatment. Similarly, unstimulated IL6 high-risk fibroblasts had lower COL5A1 (p=0.012) levels than IL6 low-risk fibroblasts. In the genetic association study, the COL5A1-IL1B-IL6 T-C-G (p=0.034, Haplo-score 2.1) and the COL5A1-IL1B-IL6R T-C-A (p=0.044, Haplo-score: 2.0) combinations were associated with an increased susceptibility to ACL injury in the Swedish cohort when only male participants were evaluated. CONCLUSIONS: This study shows that polymorphisms within genes of the inflammatory pathway modulate the expression of structural and fibril-associated ECM components in a genetic risk depended manner, contributing to an increased susceptibility to ACL injuries.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/genética , Matriz Extracelular/genética , Interleucina-1beta/genética , Interleucina-6/genética , Adulto , Biglicano/genética , Estudios de Casos y Controles , Células Cultivadas , Colágeno Tipo I/genética , Cadena alfa 1 del Colágeno Tipo I , Colágeno Tipo V/genética , Decorina/genética , Femenino , Fibroblastos , Estudios de Asociación Genética , Genotipo , Humanos , Inflamación , Masculino , Persona de Mediana Edad , Factores de Riesgo , Sudáfrica , Suecia , Adulto Joven
6.
Knee Surg Sports Traumatol Arthrosc ; 27(4): 1251-1258, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30361757

RESUMEN

PURPOSE: To study the pattern of migration and clinical results up to 10 years of uncemented versus cemented fixation of the femoral component in total knee arthroplasty. METHODS: Randomized controlled trial was conducted of 41 patients (23 women, 18 men) under the age of 60 years using radiostereometric analysis. RESULTS: About two-thirds of the cemented implants and half of the uncemented implants stabilized between 2 and 10 years, while the remainder displayed a small annual increase of maximum total point motion of 0.09-0.10 mm/year. At 10 years there were no statistically significant differences in migration or clinical results between the groups. CONCLUSION: Uncemented fixation with titanium fiber mesh coating of the femoral component in total knee arthroplasty works equally as well as cemented fixation up to 10 years. An annual migration of 0.1 mm seems compatible with excellent long-term performance. LEVEL OF EVIDENCE: I.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Fémur/cirugía , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Rango del Movimiento Articular/fisiología , Anciano , Femenino , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Análisis Radioestereométrico , Estudios Retrospectivos , Resultado del Tratamiento
7.
J Orthop ; 14(4): 454-460, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28819343

RESUMEN

PURPOSE: The aim of the study was to determine the 5 year migratory and wear patterns, adverse events and clinical outcomes of a cementless, porous acetabular cup. METHODS: RSA imaging of a cohort of 11 patients was retrospective analysed at 5 years post Total Hip Arthroplasty (THA). Changes in pain, function and symptoms of the hip at 5 years post-THA were compared to preoperative and 2 year postoperative assessments on the Harris Hip Score (HHS) and Hip dysfunction and Osteoarthritis Outcome Score (HOOS). RESULTS: The majority of cup migration occurred up to 6 months and stabilised thereafter (6 months to 5 years, p = 0.091-0.866, Wilcoxon Signed Rank test). The direction of rotation around the 3 axes was evenly distributed among the cups between anterior-posterior rotation, internal-external rotation and increased-decreased inclination. The majority of the cups translated proximally, at an average migration of 0.36 mm (±95%CI 0.17) at 5-years post-THA. Following initial bedding in, up to 6 months, there was no detectable polyethylene wear between 6 months and 5 years. At 5 years postoperatively, a statistically significant difference was observed across all HOOS subscales in comparison to preoperative values, with higher means reported at 5 years (p < 0.001). The total mean HHS displayed a statistically significant improvement, increasing from 'poor' preoperatively to 'good' at 5 years post-THA. CONCLUSION: Following initial migration between discharge and 6 months, the cementless porous acetabular cup demonstrated a tendency for stabilisation from 6 months up to 5 years post-THA, suggesting good mid-term fixation. Additionally, improvements in clinical outcome measures of pain, function and quality-of-life remained high following THA at 5 years post-surgery.

8.
Acta Orthop ; 88(2): 166-172, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27996349

RESUMEN

Background and purpose - Computer-assisted surgery (CAS) in total knee arthroplasty (TKA) has been used in recent years in the hope of improving the alignment and positioning of the implant, thereby achieving a better functional outcome and durability. However, the role of computer navigation in TKA is still under debate. We used radiostereometric analysis (RSA) in a randomized controlled trial (RCT) to determine whether there are any differences in migration of the tibial component between CAS- and conventionally (CONV-) operated TKA. Patients and methods - 54 patients (CAS, n = 26; CONV, n = 28) with a mean age of 67 (56-78) years and with osteoarthritis or arthritic disease of the knee were recruited from 4 hospitals during the period 2009-2011. To estimate the mechanical stability of the tibial component, the patients were examined with RSA up to 24 months after operation. The following parameters representing tibial component micromotion were measured: 3-D vector of the prosthetic marker that moved the most, representing the magnitude of migration (maximum total point motion, MTPM); the largest negative value for y-translation (subsidence); the largest positive y-translation (lift-off); and prosthetic rotations. The precision of the RSA measurements was evaluated and migration in the 2 groups was compared. Results - Both groups had most migration within the first 3 months, but there was no statistically significant difference in the magnitude of the migration between the CAS group and the CONV group. From 3 to 24 months, the MTPM (in mm) was 0.058 and 0.103 (p = 0.1) for the CAS and CON groups, respectively, and the subsidence (in mm) was 0.005 and 0.011 (p = 0.3). Interpretation - Mean MTPM, subsidence, lift-off, and rotational movement of tibial trays were similar in CAS- and CONV-operated knees.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Falla de Prótesis , Análisis Radioestereométrico/métodos , Cirugía Asistida por Computador/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología
9.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2606-13, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26708412

RESUMEN

PURPOSE: To investigate gait asymmetries and the effect of walking on compliant surfaces in individuals with unilateral total knee arthroplasty (TKA), hypothesizing that asymmetries would increase as an effect of the compliant surface. METHODS: Individuals with unilateral TKA ~19 months post-operative (n = 23, median age 59 years) recruited from one orthopaedic clinic and age- and gender-matched healthy individuals without knee complaints (n = 23, median age 56 years) walked at comfortable speed on a hard surface and on a compliant surface. 3D kinematic analyses were made for knee and hip angles in sagittal and frontal planes, stance time, step length, and gait velocity. RESULTS: Shorter stance time (p < 0.01) and less peak knee flexion (p < 0.001) at weight bearing acceptance was found in the prosthetic side compared with the contralateral side. Larger knee (p < 0.01) and hip (p < 0.001) adduction was found compared with healthy controls. Neither asymmetries between the prosthetic and the contralateral side nor differences compared with healthy controls were enhanced when walking on compliant surfaces compared with hard surfaces. CONCLUSION: The TKA group adapted their gait to compliant surfaces similarly to healthy controls. Gait asymmetries in the TKA group observed on hard surface were not enhanced, and adduction in hip and knee joints did not increase further as an effect of walking on compliant surfaces. Thus, unfavourable knee joint loading did not increase when walking on a compliant surface. This implies that recommendations for walking on soft surfaces to reduce knee joint loading are not counteracted by increased gait asymmetries and unfavourable joint loading configurations. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Marcha/fisiología , Osteoartritis de la Rodilla/cirugía , Caminata/fisiología , Adulto , Anciano , Fenómenos Biomecánicos , Estudios de Casos y Controles , Estudios Transversales , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Soporte de Peso
10.
Clin Orthop Relat Res ; 471(7): 2238-44, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23334705

RESUMEN

BACKGROUND: One cross-linked polyethylene (XLPE) liner is manufactured using a lower dose of radiation, 5 Mrad, which may result in less cross-linking. The reported in vivo wear rate of this XLPE liner in patients undergoing THA has varied, and has included some patients in each reported cohort who had greater than 0.1 mm/year of wear, which is an historical threshold for osteolysis. Previous studies have measured wear on plain radiographs, an approach that has limited sensitivity. QUESTIONS/PURPOSES: We therefore measured the amount and direction of wear at 6 years using Radiostereometric analysis (RSA) in patients who had THAs that included a cross-linked polyethylene liner manufactured using 5 Mrad radiation. METHODS: We prospectively reviewed wear in 30 patients who underwent primary THAs with the same design of cross-linked acetabular liner and a 28-mm articulation. Tantalum markers were inserted during surgery and all patients had RSA radiographic examinations at 1 week, 6 months, 1, 2, and 6 years postoperatively. RESULTS: The mean proximal, two-dimensional (2-D) and three-dimensional (3-D) wear rates calculated between 1 year and 6 years were 0.014, 0.014, and 0.018 mm/per year, respectively. The direction of the head penetration recorded between 1 week and 6 years was in a proximal direction for all patients, proximolateral for 16 of 24 patients, and proximomedial for eight of 24 patients. CONCLUSIONS: The proximal, 2-D and 3-D wear of a XLPE liner produced using 5 Mrad of radiation was low but measurable by RSA after 6 years. No patients had proximal 2-D or 3-D wear rates exceeding 0.1 mm/year. Further followup is needed to evaluate the effect of XLPE wear particles on the development of long-term osteolysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Articulación de la Cadera/cirugía , Prótesis de Cadera , Polietileno/efectos de la radiación , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Marcadores Fiduciales , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/etiología , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico , Estrés Mecánico , Tantalio , Factores de Tiempo , Resultado del Tratamiento
11.
Acta Orthop ; 83(2): 148-52, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22248172

RESUMEN

BACKGROUND AND PURPOSE: Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now report on the 10-year results. PATIENTS AND METHODS: In 8 patients, we measured wear of annealed highly crosslinked PE prospectively with radiostereometry after 10 years. Activity was assessed by UCLA activity score and a specifically designed activity score. Conventional radiographs were evaluated for osteolysis and clinical outcome by the Harris hip score (HHS). RESULTS: The mean (95% CI) proximal head penetration for highly crosslinked PE after 10 years was 0.07 (-0.015 to 0.153) mm, and the 3D wear was 0.2 (0.026 to 0.36) mm. Without creep, proximal head penetration was 0.02 (-0.026 to 0.066) mm and for 3D penetration was 0.016 (-0.47 to 0.08) mm. This represents an annual proximal wear of less than 2 µm. All cups were clinically and radiographically stable but showed a tendency of increased rotation after 5 years. INTERPRETATION: Wear for annealed highly crosslinked PE is extremely low up to 10 years. Free radicals do not affect mechanical performance or lead to clinically adverse effects. Creep stops after the first 6 months after implantation. Highly crosslinked PE is a true competitor of hard-on-hard bearings.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Cabeza Femoral/diagnóstico por imagen , Prótesis de Cadera , Polietileno/efectos adversos , Diseño de Prótesis , Análisis Radioestereométrico , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Cabeza Femoral/cirugía , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Estudios Prospectivos , Falla de Prótesis , Estudios Retrospectivos , Factores de Tiempo
12.
Acta Orthop ; 77(3): 393-401, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16819677

RESUMEN

BACKGROUND: Excellent mid-term results have stimulated the use of hemispherical porous-coated cups in hip replacement. With longer follow-up, there have been problems related to polyethylene wear and liner fixation, and osteolysis has been documented in reports of selected cases. We evaluated the clinical and radiographic results of 50 patients followed for 12 years. PATIENTS AND METHODS: 58 consecutive patients (58 hips), mean age 55 years, were operated with Harris-Galante (HG) I or II cups using line-to-line fit and additional screw fixation. Polyethylene linersgamma-sterilized in air and 32-mm ceramic heads were used. 8 patients died within 12 years, leaving 50 patients with a complete 12 year follow-up. 23 of the cups were also evaluated with radiostereometry (RSA) for migration, liner stability, and wear. RESULTS: All metal shells were still in situ after 12 years. 4 hips had been revised due to femoral loosening. In these revisions, the liner had been exchanged due to wear and/or instability, resulting in a cup survival rate of 89%. 28 cups displayed osteolytic lesions, mainly in relation to screws. RSA revealed minimum translations, but in many cases there were pronounced liner rotations suggesting unstable liners within the metal shell. The annual proximal wear was 0.09 mm and the three-dimensional wear was 0.16 mm. INTERPRETATION: RSA can predict the long-term performance of cup fixation. Low migration during the initial years after implantation indicates excellent long-term results regarding fixation of the metal shell. The main problem with this design appears to be liner instability and osteolysis, factors that are probably interrelated. Because these phenomena are clinically silent, we recommend regular follow-up of patients with HG cups to avoid sudden loosening and complicated revisions.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Tornillos Óseos , Materiales Biocompatibles Revestidos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Porosidad , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación , Propiedades de Superficie , Resultado del Tratamiento
13.
Arch Orthop Trauma Surg ; 124(6): 404-9, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15156331

RESUMEN

INTRODUCTION: Whether biochemical markers of bone metabolism can be used in assessing the conditions of implant fixation is unknown. In this study, the serum levels of three bone markers were measured prospectively in patients undergoing total knee arthroplasty (TKA) to determine if patients with different fixation conditions of the tibial component showed any differences in the levels of the markers. MATERIALS AND METHODS: The fixation of the tibial component in 40 knees (40 patients, 14 male and 26 female, average age 71 years) was assessed by radiostereometric analysis (RSA), and based upon the pattern of migration, implants with stable fixation ( n=25) and potentially unstable fixation ( n=15) were identified. Serum levels of carboxyterminal propeptide of type I procollagen (PICP), osteocalcin (OC) and cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were assessed and compared between the two fixation groups. Blood samples were obtained preoperatively (baseline) and repeated postoperatively at 1 week, 3, 6, 12, and 24 months. RESULTS: The baseline levels of the markers were statistically the same ( p>0.05) between the two fixation groups. Postoperatively, ICTP levels in the unstable group were significantly higher than in the stable group from 6 to 24 months ( p=0.02). Levels of OC in the unstable group were higher at 12 and 24 months compared with the stable group, reaching statistical significance only at 12 months ( p=0.03). No difference in the levels of PICP was found between the two groups. CONCLUSION: The findings indicate a more active bone turnover probably at the bone-cement/implant interface in knees with potentially unstable fixation. It reveals the potential value for biochemical markers in monitoring implant fixation and aseptic loosening and suggests a possibility for improving implant fixation by drugs which inhibit osteolysis.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Resorción Ósea/diagnóstico , Inestabilidad de la Articulación/diagnóstico , Osteoartritis de la Rodilla/cirugía , Osteocalcina/sangre , Fragmentos de Péptidos/sangre , Procolágeno/sangre , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Artroplastia de Reemplazo de Rodilla/efectos adversos , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Probabilidad , Pronóstico , Estudios Prospectivos , Falla de Prótesis , Sensibilidad y Especificidad , Tibia/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA