Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Ann R Coll Surg Engl ; 106(4): 338-343, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36688865

RESUMEN

INTRODUCTION: Two-week wait (TWW) volume and colorectal cancer (CRC) detection pose an increasing challenge for NHS cancer services. Primary aims were to assess the introduction of faecal immunochemical tests (FIT) into clinical practice at our centre, the impact on TWW referral volume and CRC diagnoses, and to provide an update to previously published work. A secondary aim was to correlate FIT value and investigation. METHODS: TWW CRC data following incorporation of FIT into clinical practice were analysed (1 June 2019-31 July 2021). Parameters assessed were monthly referral volume, CRC detection, primary care FIT volume and secondary care investigations. Referrals and CRC detection rates were compared with previously published data (2009-2019). Data relating to primary care FIT were collated from Berkshire and Surrey Pathology Services. RESULTS: TWW referrals increased 360% (2009-2020). CRC incidence decreased from 8.87% to 3.24%. Following incorporation into clinical practice, primary care FIT requests have increased to >450/month and accompanied 1,722/4,796 referrals. CRC incidence is static (3-4%). Patients with FIT <10µg Hb/g faeces undergo radiological imaging more commonly, whereas FIT-positive patients are more likely to undergo endoscopy, although the difference is not statistically significant. CONCLUSIONS: No significant change in CRC diagnosis was observed, despite increasing TWW referrals. Increasing utilisation of FIT in both primary and secondary care has helped maintain CRC detection while avoiding diagnostic delay. This study supports growing evidence highlighting the value of FIT in triage, referral and TWW investigation. FIT appears increasingly important for allocating secondary care resources (endoscopy), while guiding primary care referral. Additional low-cost strategies to determine prioritisation or reassurance (e.g. repeat FIT) require further evaluation.


Asunto(s)
Neoplasias Colorrectales , Humanos , Sensibilidad y Especificidad , Neoplasias Colorrectales/patología , Diagnóstico Tardío , Colonoscopía , Heces/química , Detección Precoz del Cáncer/métodos , Hemoglobinas/análisis
2.
Ann R Coll Surg Engl ; 105(6): 501-506, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36688842

RESUMEN

INTRODUCTION: A wandering spleen occurs when laxity or absence of the suspensory ligaments allows migration throughout the abdomen. Gastric outlet obstruction resulting from this abnormality is rare. We present a systematic literature search and a case that was managed successfully with surgical intervention at our centre. METHODS: A systematic search of the PubMed, Embase™, Medline® and Google Scholar™ databases was carried out employing the combined search terms "gastric outlet obstruction" AND "wandering spleen". Six results were included for final analysis. RESULTS: All six search results described a single case each. Patients underwent surgical management (open or laparoscopic) after initial investigation utilising a range of modalities. There were no mortalities reported at 90 days. The single case we present was complicated by gastric perforation; the patient made a successful recovery following open splenopexy and stapled wedge resection of the stomach. CONCLUSIONS: A wandering spleen is a rare diagnosis and there are only six reported cases of gastric outlet obstruction secondary to a wandering spleen in the literature. None report associated gastric perforation. There are a variety of presenting symptoms, intraoperative findings and operative techniques used to address the gastrosplenic abnormality. The case reported by our centre adds to this limited evidence base and demonstrates a successful outcome from definitive surgical management. We highlight the need to seek early gastro-oesophageal expertise if any gastric pathology is found together with anatomical abnormality of the spleen.


Asunto(s)
Obstrucción de la Salida Gástrica , Laparoscopía , Ectopía del Bazo , Humanos , Obstrucción de la Salida Gástrica/etiología , Obstrucción de la Salida Gástrica/cirugía , Laparoscopía/métodos , Esplenectomía/métodos , Ectopía del Bazo/complicaciones , Ectopía del Bazo/diagnóstico por imagen , Ectopía del Bazo/cirugía , Informes de Casos como Asunto
3.
Colorectal Dis ; 21(12): 1354-1363, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31243879

RESUMEN

AIM: Postoperative anastomotic leakage (AL) or bleeding (AB) significantly impacts on patient outcome following colorectal resection. To minimize such complications, surgeons can utilize different techniques perioperatively to assess anastomotic integrity. We aim to assess published anastomotic complication rates following left-sided colonic resection, comparing the use of intra-operative flexible endoscopy (FE) against conventional tests used to assess anastomotic integrity. METHODS: PubMed/MEDLINE and Embase online databases were searched for non-randomized and randomized case-control studies that investigated postoperative AL and/or AB rates in left-sided colonic resections, comparing intra-operative FE against conventional tests. Data from eligible studies were pooled, and a meta-analysis using Review Manager 5.3 software was performed to assess for differences in AL and AB rates. RESULTS: Data from six studies were analysed to assess the impact of FE on postoperative AL and AB rates (1084 and 751 patients respectively). Use of FE was associated with reduced postoperative AL and AB rates, from 6.9% to 3.5% and 5.8% to 2.4% respectively. Odds ratios favoured intra-operative FE: 0.37 (95% CI 0.21-0.68, P = 0.001) for AL and 0.35 (95% CI 0.15-0.82, P = 0.02) for AB. CONCLUSION: This meta-analysis showed that the use of intra-operative FE is associated with a reduced rate of postoperative AL and AB, compared to conventional anastomotic testing methods.


Asunto(s)
Colectomía/métodos , Colonoscopía/instrumentación , Colostomía/efectos adversos , Cuidados Intraoperatorios/métodos , Complicaciones Posoperatorias/prevención & control , Adulto , Anciano , Anastomosis Quirúrgica/efectos adversos , Fuga Anastomótica/etiología , Fuga Anastomótica/prevención & control , Estudios de Casos y Controles , Colon/cirugía , Colonoscopía/métodos , Femenino , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/prevención & control , Ensayos Clínicos Controlados Aleatorios como Asunto , Recto/cirugía
4.
Case Rep Surg ; 2017: 5878614, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28785504

RESUMEN

Dormia baskets are commonly used during endoscopic retrograde cholangiopancreatography (ERCP). One complication is basket retention, through impaction with a gallstone or wire fracture. We describe a case where the external handle of the basket snapped causing retained basket plus large gallstone impacted in the common bile duct (CBD). Following laparoscopic cholecystectomy, laparoscopic CBD exploration allowed direct stone fragmentation under vision with the choledochoscope. Fragments were removed using a choledochoscopic basket and Fogarty catheter, and the basket was withdrawn. Literature search identified 114 cases of retained baskets with management including shockwave lithotripsy (27%), papillary balloon dilatation (22%), open CBD exploration (11%), and one laparoscopic case.

5.
Ann Med Surg (Lond) ; 18: 10-13, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28480036

RESUMEN

BACKGROUND: The UK Supreme Court recently ruled that when consenting patients for treatments or procedures, clinicians must also discuss any associated material risks. We surveyed medical staff at a large UK teaching hospital in order to ascertain knowledge of consent law and current understanding of this change. MATERIALS AND METHODS: Email survey sent to medical staff in all specialities at Norfolk and Norwich University Hospital in February 2016. RESULTS: 245 responses (141 Consultants and 104 junior doctors, response rate 32%). 82% consent patients for procedures at least monthly and 23% daily. 31% were not familiar with the concept of material risk. 35% were familiar with the recent change in consent law, 41% were not. 18% were "very uncertain" and 64% "a little uncertain" that their consenting process meets current legal requirements. >92% think that landmark cases and changes in law should be discussed through professional bodies and circulated better locally. CONCLUSION: The majority were not familiar with the concept of material risk and recent legal changes. A majority were not confident that their practice meets current requirements, suggesting that recent changes in consent law may not be widely understood at this hospital. We suggest more guidance and education may be necessary than is currently available. Increased understanding of recent changes to consent law will reduce the risk taken by NHS trusts and offer patients a service compliant with Supreme Court guidance.

6.
Gastrointest Endosc ; 45(6): 493-7, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9199907

RESUMEN

BACKGROUND: Current induced in a guidewire during papillotomy poses a danger of injury to the bile duct. We measured currents induced in three commercially available guidewires and a prototype fiberglass wire during simulated sphincterotomy under standard and nonstandard conditions. METHODS: Blended current at 55 W was applied to a double-lumen papillotome grounded through a 1000 omega resistor. For extreme conditions, power was increased to 70 W using a single-lumen papillotome. Fault conditions were created with a break in the insulation at the distal end of each wire. Guidewire-induced current was measured, and safety calculations performed for adherence to accepted standards for electrosurgical devices. RESULTS: Induced current was within safety limits for all wires tested under standard conditions. With insulation faults, one of the commercially available wires was unsafe. Under extreme conditions, with or without faults, the three commercial wires produced currents ranging from 9% to 225% above acceptable levels, while only the prototype wire remained safe. CONCLUSIONS: Most guidewires contain metal cores that function as capacitors. Because its core is primarily fiberglass, the prototype wire generates less induced current under nonstandard conditions, thus achieving a greater margin of safety during wire-guided sphincterotomy.


Asunto(s)
Conductos Biliares/cirugía , Modelos Anatómicos , Esfinterotomía Endoscópica/instrumentación , Duodenoscopios , Duodenoscopía/métodos , Vidrio , Humanos , Seguridad
8.
Ann Thorac Surg ; 52(2): 182-8, 1991 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1863137

RESUMEN

The effects of left internal mammary artery (LIMA) dissection and distal division on phrenic nerve perfusion and function were examined in an adult swine model. Phrenic nerve perfusion was determined by left atrial injection of radioactively labeled microspheres. Phrenic nerve function was determined by measuring nerve and diaphragm potentials evoked by bilateral phrenic nerve stimulation. In the first group of animals (n = 9), the LIMA was dissected with ligation of all its branches. Left phrenic nerve perfusion and function decreased after LIMA dissection in every animal studied, whereas only minimal changes were observed on the right. Sixty minutes after LIMA dissection, left phrenic nerve mean perfusion decreased 71%. Left phrenic nerve and left diaphragm mean action potential amplitudes decreased 54% and 80%, respectively. In the second group of animals (n = 4), the LIMA dissection was performed without division of the pericardiacophrenic artery, a small proximal branch of the internal mammary artery that supplies the phrenic nerve. Sixty minutes after LIMA dissection, left phrenic nerve perfusion had decreased by 21% from control values, with a corresponding decrease in left phrenic nerve and diaphragm mean action potential amplitudes of 19% and 23%, respectively. These results indicate that LIMA dissection with division of all its branches in this model is associated with a significant impairment in left phrenic nerve perfusion and function and suggests a causal relationship. These results may also explain the apparent increased phrenic nerve cold sensitivity and increased incidence of phrenic nerve dysfunction associated with LIMA grafting.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Arterias Mamarias/cirugía , Nervio Frénico/irrigación sanguínea , Potenciales de Acción , Animales , Diafragma/inervación , Diafragma/fisiopatología , Disección , Hipotermia Inducida/efectos adversos , Nervio Frénico/fisiopatología , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA