1.
J Vasc Surg Cases Innov Tech ; 8(1): 19-22, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35024524

RESUMEN

Bacillus Calmette-Guérin (BCG) vaccine has been successfully used to treat bladder cancer. However, sporadic cases of mycotic arterial aneurysms have been reported. These patients typically develop a Mycobacterium bovis infection of an existing aneurysm or graft. In the present report, we have described the case of a patient with a ruptured nonaneurysmal abdominal aorta years after intravesicular BCG therapy. Emergent aortic endograft repair was successful. After subsequent evaluation confirmed M. bovis infection, the patient was treated with a prolonged course of antimycobacterial therapy. Vascular surgeons should maintain suspicion for atypical aortic ruptures in patients with exposure to intravesicular BCG therapy.

2.
Clin Infect Dis ; 74(10): 1812-1820, 2022 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-34409431

RESUMEN

BACKGROUND: The impact of remdesivir (RDV) on mortality rates in coronavirus disease 2019 (COVID-19) is controversial, and the mortality effect in subgroups of baseline disease severity has been incompletely explored. The purpose of this study was to assess the association of RDV with mortality rates in patients with COVID-19. METHODS: In this retrospective cohort study we compared persons receiving RDV with those receiving best supportive care (BSC). Patients hospitalized between 28 February and 28 May 2020 with laboratory-confirmed severe acute respiratory syndrome coronavirus 2 infection were included with the development of COVID-19 pneumonia on chest radiography and hypoxia requiring supplemental oxygen or oxygen saturation ≤94% with room air. The primary outcome was overall survival, assessed with time-dependent Cox proportional hazards regression and multivariable adjustment, including calendar time, baseline patient characteristics, corticosteroid use, and random effects for hospital. RESULTS: A total of 1138 patients were enrolled, including 286 who received RDV and 852 treated with BSC, 400 of whom received hydroxychloroquine. Corticosteroids were used in 20.4% of the cohort (12.6% in RDV and 23% in BSC). Comparing persons receiving RDV with those receiving BSC, the hazard ratio (95% confidence interval) for death was 0.46 (.31-.69) in the univariate model (P < .001) and 0.60 (.40-.90) in the risk-adjusted model (P = .01). In the subgroup of persons with baseline use of low-flow oxygen, the hazard ratio (95% confidence interval) for death in RDV compared with BSC was 0.63 (.39-1.00; P = .049). CONCLUSION: Treatment with RDV was associated with lower mortality rates than BSC. These findings remain the same in the subgroup with baseline use of low-flow oxygen.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Adenosina Monofosfato/análogos & derivados , Alanina/análogos & derivados , Humanos , Oxígeno , Estudios Retrospectivos , SARS-CoV-2
3.
Cardiol Young ; 18(3): 328-36, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18460222

RESUMEN

OBJECTIVE: In 1990, Fontan, Kirklin, and colleagues published equations for survival after the so-called "Perfect Fontan" operation. After 1988, we evolved a protocol using an internal or external polytetraflouroethylene tube of 16 to 19 millimetres diameter placed from the inferior caval vein to either the right or left pulmonary artery along with a bidirectional cava-pulmonary connection. The objective of this study was to test the hypothesis that a "perfect" outcome is routinely achievable in the current era when using a standardized surgical procedure. METHODS: Between 1 January, 1988, and 12 December, 2005, 112 patients underwent the Fontan procedure using an internal or external polytetraflouroethylene tube plus a bidirectional cava-pulmonary connection, the latter usually having been constructed as a previous procedure. This constituted 45% of our overall experience in constructing the Fontan circulation between 1988 and 1996, and 96% of the experience between 1996 and 2005. Among all surviving patients, the median follow-up was 7.3 years. We calculated the expected survival for an optimal candidate, given from the initial equations, and compared this to our entire experience in constructing the Fontan circulation. RESULTS: An internal tube was utilized in 61 patients, 97% of whom were operated prior to 1998, and an external tube in 51 patients, the latter accounting for 95% of all operations since 1999. At 1, 5, 10 and 15 years, survival of the entire cohort receiving polytetraflouroethylene tubes is superimposable on the curve calculated for a "perfect" outcome. Freedom from replacement or revision of the tube was 97% at 10 years. CONCLUSION: Using a standardized operative procedure, combining a bidirectional cavopulmonary connection with a polytetraflouroethylene tube placed from the inferior caval vein to the pulmonary arteries for nearly all patients with functionally univentricular hearts, early and late survival within the "perfect" outcome as predicted by the initial equations of Fontan and Kirklin is routinely achievable in the current era. The need for late revision or replacement of the tube is rare.


Asunto(s)
Procedimiento de Fontan , Procedimiento de Fontan/instrumentación , Procedimiento de Fontan/métodos , Procedimiento de Fontan/mortalidad , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/cirugía , Humanos , Análisis Multivariante , Politetrafluoroetileno , Reoperación , Resultado del Tratamiento
5.
Echocardiography ; 23(5): 421-7, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16686630

RESUMEN

In this report, we present 12 patients (range 14-76 years, mean 40 +/- 22.7 years) who underwent surgical repair of a ventricular septal defect (VSD). Location, size, and surrounding anatomy of the VSD were assessed prior to intervention in all patients with live/real time three-dimensional transthoracic echocardiography (3DTTE). In 9 patients, measurements of maximum dimension, circumference, and area by 3DTTE correlated well with the same measurements from intraoperative three-dimensional transesophageal echocardiographic (3DTEE) reconstruction. 3DTTE measurement of maximum dimension of VSDs also agreed well with maximum dimension by surgery in 10 patients. Live/real time 3DTTE accurately defined VSD location, size, and surrounding anatomy in all patients studied by us. VSD characterization by live 3DTTE agreed well with surgery descriptions and 3DTEE measurements.


Asunto(s)
Sistemas de Computación , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/patología , Adolescente , Adulto , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
6.
Echocardiography ; 22(2): 137-43, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15693780

RESUMEN

This preliminary study demonstrates the superiority of live three-dimensional transthoracic echocardiography (3D TTE) over two-dimensional (2D) TTE in the assessment of left atrial (LA) tumors in four patients studied by us (three myxomas, one hemangioma, all subsequently pathologically proven). Because of the unique ability of live 3D TTE to systematically section and view the contents of an intracardiac mass, LA myxomas in the three patients studied could be more confidently diagnosed by noting isolated echolucent areas consistent with hemorrhage/necrosis in the tumor mass. On the other hand, a definite echolucent area was found by 2D TTE in only two of the three patients with myxoma. In the fourth patient with a hemangioma, live 3D TTE showed much more extensive and closely packed echolucencies with little solid tissue as compared to a myxoma consistent with a highly vascularized tumor. In contrast, 2D TTE demonstrated only two isolated echolucencies in the tumor suggesting an erroneous diagnosis of myxoma.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía , Neoplasias Cardíacas/diagnóstico por imagen , Femenino , Atrios Cardíacos , Hemangioma/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Mixoma/diagnóstico por imagen
7.
Am J Geriatr Cardiol ; 13(5): 279-84, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15365294

RESUMEN

Aortic valve stenosis (AS) severity can be estimated by various modalities. Due to some of the limitations of the currently available methods, the usefulness of live three-dimensional transthoracic echocardiography (3D TTE) in the assessment of AS was explored. Live 3D TTE was able to visualize the aortic valve orifice in all 11 patients studied. Live 3D TTE correctly estimated the severity of AS in all 10 patients in whom AS severity could be evaluated at surgery. These included eight patients with severe AS and two with moderate AS. Two of these 10 patients with AS had associated hypertrophic cardiomyopathy and underwent myectomy at the time of aortic valve replacement. Aortic valve orifice area measurements by live 3D TTE correlated well with intraoperative three-dimensional transesophageal echocardiographic reconstruction measurements (r=0.85) but not as well with two-dimensional transesophageal echocardiography measurements (r=0.64). Live 3D TTE measurements of the aortic valve orifice area also did not correlate well with two-dimensional transthoracic echocardiography measurements (r=0.46) but the number of patients studied with two-dimensional transthoracic echocardiography was smaller (only seven) and four of these did not undergo two-dimensional transthoracic echocardiography at the authors' institution. Altogether, four patients with severe AS by live 3D TTE, and subsequently confirmed at surgery, were misdiagnosed as having moderate AS by two-dimensional transthoracic echocardiography. Because it is completely noninvasive and views the aortic valve in three dimensions, 3D TTE could be a useful complement to the existing modalities in the evaluation of AS severity.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Tridimensional , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Ecocardiografía Doppler en Color , Femenino , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Índice de Severidad de la Enfermedad
8.
Echocardiography ; 21(2): 199-202, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14961805

RESUMEN

Right coronary artery to coronary sinus fistula is a rare anomaly. We present a unique case of an adult patient with multiple fistulae from the right coronary artery draining into the coronary sinus near the posterior left atrium-left ventricle junction, first suspected by transthoracic two-dimensional echocardiography. The multiple openings were not seen by any invasive or noninvasive techniques and were noted only at the time of surgery. To our knowledge, this is the first case of multiple fistulae connecting the right coronary artery to the coronary sinus that has been reported in the English literature.


Asunto(s)
Anomalías de los Vasos Coronarios/diagnóstico , Ecocardiografía/métodos , Fístula/diagnóstico , Adulto , Cateterismo Cardíaco , Angiografía Coronaria , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/cirugía , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Fístula/complicaciones , Fístula/cirugía , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
9.
Echocardiography ; 20(2): 203-9, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12848691

RESUMEN

We evaluated the potential usefulness of three-dimensional (3D) transesophageal echocardiography (TEE) in assessing individual scallop/segment prolapse in 36 adult patients with mitral valve prolapse (MVP) undergoing surgical correction. Intraoperative 3D TEE correctly identified the location of scallop/segment prolapse in 34 of 36 patients (94%). However, in 6 of these patients 3D TEE images revealed more scallops or segments with prolapse than the surgeon noted intraoperatively. Prolapse of these areas was less prominent and this could possibly explain the lack of correlation with the surgical findings in these patients. In another 2 patients areas of prolapse seen by the surgeon were missed by 3D TEE because some of those scallops/segments could not be well imaged due to image "drop out" and artifacts. Thus, perfect correlation between 3D TEE and surgery was noted in 28 of 36 (78%) patients. Noncoaptation of the MV was also identified in 2 patients. The prolapsed area of posterior (n = 28 observations) and anterior (n = 9 observations) MV leaflets ranged from 1 cm2 to 9 cm2 (mean 3.50 cm2+/- 2.14) and 1.20 cm2 to 5.99 cm2 (mean 3.21 cm2+/- 1.33), respectively. Interobserver and intraobserver agreement for location and area of MVP was excellent (r = 0.97 and r = 0.99, respectively; all P values are <0.0001). In conclusion, 3D TEE is useful in identifying the location of MVP. It may also be potentially useful in assessing the extent of individual scallop/segment prolapse and identifying sites of MV noncoaptation. This information could aid the surgeon in deciding the extent of MV resection.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/patología , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/métodos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Probabilidad , Estudios Prospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
10.
Echocardiography ; 20(1): 105-9, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12848709

RESUMEN

We present two- and three-dimensional transesophageal echocardiographic findings of two adult patients who presented for reoperation after previous repair of a partial atrioventricular (AV) septal defect. Both patients had a cleft in the left AV valve with severe regurgitation. One patient had an additional 10 x 5 mm defect connecting the left ventricle to the right atrium through the AV junction. Three-dimensional echocardiography was superior to two-dimensional echocardiography in comprehensively delineating the anatomical defects in the left AV valve and the AV junction.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Adulto , Femenino , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interventricular/cirugía , Humanos , Reoperación
12.
Ultrasound Med Biol ; 28(11-12): 1389-93, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12498933

RESUMEN

As compared with two-dimensional (2-D) transesophageal echocardiography (TEE), 3-D echocardiography now permits more realistic visualization of cardiac anatomy and of intracardiac lesions. The aim of this study was to apply newer 3-D echocardiographic techniques to quantify volumes of intracardiac masses undergoing surgical resection seen during an intraoperative TEE. The calculated volumes were compared with actual in vitro measurements of surgically resected masses. A total of 14 patients (9 men; 5 women; age range between 21 and 77 years) with intracardiac mass lesions (4 tumors: 3 left atrial myxomas and 1 mitral valve fibroelastoma, and 10 vegetations: 5 aortic valve, 3 mitral valve, 1 tricuspid and 1 pulmonary valve) were studied. Using commercially available 3-D reconstruction software (TomTec v. 4.1), the volumes of intracardiac masses were estimated using both the average rotation (rotation around the long axis, AR) and disk summation (parallel short axis cuts, DS) methods. Volumes of these lesions were also measured in vitro by water submersion. They ranged from 0.20 mL to 24 mL (mean +/- SD = 8.07 +/- 9.21 mL). Both 3-D TEE AR and 3-D TEE DS calculated volumes correlated excellently with in vitro measured volumes (r = 1.00 and r = 0.98, respectively, p = < 0.0001). The correlation between 3-D TEE AR and 3-D TEE DS calculated volumes was also excellent (r = 0.98, p = < 0.0001). In conclusion, the volume assessments by 3-D TEE of intracardiac mass lesions correlated well with in vitro measured volumes of surgical specimens. This technique may prove to be valuable in further defining intracardiac pathology and is a further advancement toward the application of clinically useful 3-D echocardiography.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Neoplasias Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Adulto , Anciano , Femenino , Neoplasias Cardíacas/patología , Neoplasias Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/patología , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Mixoma/diagnóstico por imagen , Mixoma/patología , Mixoma/cirugía , Variaciones Dependientes del Observador
13.
Ann Thorac Surg ; 74(5): 1700-2, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12440639

RESUMEN

Pulmonary vasospasm and hypertension may occur after repair or palliation of congenital cardiac defects, and can be fatal in spite of conventional treatment. Nitric oxide has been shown to improve pulmonary hypertension unresponsive to conventional measures after a variety of repairs, but use has infrequently been reported after palliative systemic to pulmonary artery shunts. We report a case of pulmonary hypertension and life threatening desaturation after a modified Blalock-Taussig shunt that responded rapidly to inhaled nitric oxide. Clinical use, further study, and prospective analysis of prophylactic use of nitric oxide appear warranted.


Asunto(s)
Anomalías de los Vasos Coronarios/cirugía , Hipertensión Pulmonar/tratamiento farmacológico , Óxido Nítrico/administración & dosificación , Complicaciones Posoperatorias/tratamiento farmacológico , Arteria Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Vasoconstricción/efectos de los fármacos , Administración por Inhalación , Femenino , Humanos , Lactante , Cuidados Paliativos , Arteria Pulmonar/efectos de los fármacos , Arteria Subclavia/cirugía
14.
Rev. bras. cir. cardiovasc ; 12(2): 188-96, abr.-jun. 1997. tab, graf
Artículo en Portugués | LILACS | ID: lil-193737

RESUMEN

Estudaram-se a demanda metabólica e a distribuiçäo do fluxo coronariano na presneça de fibrilaçäo ventricular (FV), durante a reperfusäo pós-cardioplegia. Foram colocados 15 suínos em circulaçäo extracorpórea e submetidos a parada cardíaca cardioplégica sangüínea anterógrada hipotérmica intermitente, durante uma hora, seguida por reperfusäo miocárdica controlada. Os animais foram divididos em três grupos (n=5), conforme estivessem em assistolia (Grupo 1) ou em FV de curta (grupo 2) ou longa duraçäo (Grupo 3), durante os dez primeiros minutos de reperfusäo. Os valores do consumo miocárdico de oxigênio (MVO2), em ml O2/min/g (média + erro padräo) durante a reperfusäo foram de 1,325 + 0,144 (grupo 1); 2,472 + 0,208 (Grupo 2) e 2,469 + 0,228 (Grupo 3). A diferença entre o MVO2 dos coraçöes em assistolia e o dos coraçöes em FV, quer de curta ou longa duraçäo, foi significante (p<0,001). A relaçäo entre os fluxos sangüíneos endo e epicárdico, bem como o fluxo sangüíneo coronário global (ml/mim/100g) foram semelhantes nos 3 grupos. Os valores dessa última variável, em ml/mim/100g, corresponderam a, respectivamente, 169,3 + 11,7; 185,0 + 15,7 e 179,9 + 13,2. Os resultados demonstram que a auto-regulaçäo coronária está alterada durante a fase inicial de reperfusäo pós criocardioplegia, pois a perfusäo miocárdica näo aumentou em resposta à elevaçäo do consumo de oxigênio imposta pela FV. Essa constataçäo, de grande interesse clínico, sugere que a ocorrência de FV durante a fase inicial da reperfusäo possa contribuir para o desenvolvimento de lesöes teciduais em coraçöes cujo fluxo coronário já esteja previamente comprometido, por obstruçäo coronária, distensäo ou hipertrofia ventricular.


Asunto(s)
Animales , Masculino , Femenino , Circulación Coronaria , Paro Cardíaco Inducido , Reperfusión Miocárdica , Miocardio/metabolismo , Consumo de Oxígeno , Porcinos , Factores de Tiempo , Fibrilación Ventricular
16.
Echocardiography ; 13(4): 431-434, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11442951

RESUMEN

This case report describes a patient with systemic lupus erythematosus who demonstrated by transesophageal echocardiography (TEE) a flail right coronary cusp of the aortic valve causing severe aortic regurgitation. This finding was confirmed at surgery, which showed near detachment of the right coronary leaflet near the commissure. Destruction of areas of the aortic valve has been reported in one previous case report in the absence of infective endocarditis or a traumatic process. This is the second case to our knowledge and the first to describe identification by TEE. (ECHOCARDIOGRAPHY, Volume 13, July 1996)

17.
Rev. bras. cir. cardiovasc ; 10(1): 34-42, jan.-mar. 1995. graf
Artículo en Portugués | LILACS | ID: lil-164405

RESUMEN

Testou-se uma nova emulsao de perfluorocarbonos (OxygentMR, Alliance Pharmaceutical, San Diego, CA 92121, EUA) em circulaçao extracorpórea (CEC) com hipotermia de 32 graus Celsius e hematócrito de 12 por cento. Estudaram-se 42 caes, 12 dos quais nao receberam a droga e serviram de controle (Grupo 1), enquanto os demais constituíram 3 grupos de lO animais cada, tratados com doses de Oxygent de 1,5 ml/kg (Grupo 2), 3 ml/kg (Grupo 3) e 6 ml/kg (Grupo 4) as quais geraram fluorocritos de, respectivamente, 1 por cento, 2 por cento e 3 por cento. Foram analisadas variáveis do metabolismo do oxigênio (O2) em 6 diferentes fluxos de perfusao (Q), ordenados ao acaso. Reaqueceram-se os caes, interrompeu-se a CEC e acompanharam-se os animais por l hora. Diferenças intergrupos foram analisadas pelo teste das médias dos quadrados mínimos e pelo teste de Duncan, considerando-se significantes os valores de p

Asunto(s)
Femenino , Humanos , Animales , Perros , Circulación Extracorporea/métodos , Fluorocarburos , Consumo de Oxígeno , Perfusión