1.
J Heart Lung Transplant ; 40(12): 1649-1657, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34548197

RESUMEN

BACKGROUND: The prognostic value of evaluating spirometry at a fixed time point using standardized population reference has not previously been evaluated. Our aim was to assess the association between spirometric phenotype at 12 months (Spiro12M), survival and incidence of chronic lung allograft dysfunction (CLAD) in bilateral lung transplant recipients. METHODS: We conducted a retrospective cohort study of bilateral lung transplant recipients transplanted between January 2003 and September 2012. We defined Spiro12M as the mean of the 2 prebronchodilator FEV1 measurements 12-month post-transplant. Normal spirometry was defined as FEV1/FVC ≥0.7 and FEV1≥80% and FVC≥80% predicted population-based values for that recipient. Abnormal spirometry was defined as failure to attain normal function by 12-months. We used a Cox regression model to assess the association between Spiro12M, survival, and CLAD. We used logistic regression to assess potential pretransplant donor and recipient factors associated with abnormal Spiro12M RESULTS: One hundred and eleven (51%) lung transplant recipients normalized their Spiro12M. Normal Spiro12M was associated improved survival (hazard ratio [HR] 0.60, 95% confidence interval [CI] 0.41-0.88], p = 0.009. Each 10% decrement in FEV1 increased the risk of death in a stepwise fashion. Additionally, CLAD was reduced in those with normal Spiro12M (HR:0.65, 95%CI:0.46-0.92, p = 0.016). Donor smoking history (OR:2.93, 95% CI:1.21-7.09; p = 0.018) and mechanical ventilation time in hours (OR:1.03, 95% CI:1.004-1.05; p = 0.02) were identified as independent predictors of abnormal Spiro12M. CONCLUSIONS: Abnormal Spiro12M is associated with increased mortality and the development of CLAD. The effect is dose dependent with increased dysfunction corresponding to increased risk. This assessment of phenotype at 12-months can easily be incorporated into standard of care.


Asunto(s)
Rechazo de Injerto/epidemiología , Enfermedades Pulmonares/mortalidad , Enfermedades Pulmonares/cirugía , Trasplante de Pulmón/efectos adversos , Disfunción Primaria del Injerto/epidemiología , Espirometría , Adulto , Femenino , Volumen Espiratorio Forzado , Rechazo de Injerto/diagnóstico , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Disfunción Primaria del Injerto/diagnóstico , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
2.
J Card Surg ; 33(7): 412-415, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29921031

RESUMEN

A 27-year-old female with Eisenmenger's syndrome underwent closure of a patent ductus arteriosus, closure of a perimembranous ventricular septal defect and mid muscular defect and bilateral lung transplantation. Her immediate postoperative course was complicated by severe right ventricular outflow tract (RVOT) obstruction resulting in hemodynamic collapse, a condition described as suicide right ventricle. The patient was placed on central Veno-Arterial Extra-Corporeal Membrane Oxygenation as a bridge to the relief of RVOT obstruction which included a right ventricular outflow muscle resection and a right ventricle outflow tract patch. The patient made an uneventful recovery.


Asunto(s)
Anomalías Múltiples/cirugía , Ventrículos Cardíacos/fisiopatología , Enfermedades Pulmonares/cirugía , Trasplante de Pulmón/métodos , Pulmón/irrigación sanguínea , Complicaciones Posoperatorias/fisiopatología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Adulto , Conducto Arterioso Permeable/cirugía , Complejo de Eisenmenger/cirugía , Oxigenación por Membrana Extracorpórea/métodos , Femenino , Defectos del Tabique Interventricular/cirugía , Hemodinámica , Humanos , Complicaciones Posoperatorias/terapia , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/terapia
3.
Ann Thorac Surg ; 102(3): e197-e199, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27549541

RESUMEN

After lung transplantation, pulmonary vein thrombosis is a rare, potentially life-threatening adverse event arising at the pulmonary venous anastomosis that typically occurs early and presents as graft failure and hemodynamic compromise with an associated mortality of up to 40%. The incidence, presentation, outcomes, and treatment of late pulmonary vein thrombosis remain poorly defined. Management options include anticoagulant agents for asymptomatic clots, and thrombolytic agents or surgical thrombectomy for hemodynamically significant clots. We present a rare case highlighting a delayed presentation of pulmonary vein thrombosis occurring longer than 2 weeks after lung transplantation and manifesting clinically as graft failure secondary to refractory pulmonary edema. The patient was treated successfully with surgical thrombectomy and remains well. We recommend a high index of suspicion of pulmonary vein thrombosis when graft failure after lung transplantation occurs and is not responsive to conventional therapy, and consideration of investigation with transesophageal echocardiography or computed tomography with venous phase contrast in such patients even more than 2 weeks after lung transplantation.


Asunto(s)
Trasplante de Pulmón/efectos adversos , Edema Pulmonar/diagnóstico por imagen , Venas Pulmonares/patología , Trombectomía/métodos , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/cirugía , Ecocardiografía Transesofágica/métodos , Estudios de Seguimiento , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico , Fibrosis Pulmonar Idiopática/cirugía , Trasplante de Pulmón/métodos , Masculino , Persona de Mediana Edad , Edema Pulmonar/etiología , Enfermedades Raras , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Trombosis de la Vena/etiología