Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Vaccines (Basel) ; 10(4)2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35455346

RESUMEN

Vaccine-induced immune thrombotic thrombocytopenia (VITT) with venous thrombosis is a rare complication of SARS-CoV-2 vaccination with ChAdOx1 (AstraZeneca) and AD26.COV2.S (Johnson & Johnson, New Brunswick, NJ, USA) associated with high mortality. At present, there are no known differences in the pathophysiology or risk factors of VITT with the AstraZeneca vaccine (ChAdOx1) compared with the Johnson & Johnson vaccine (AD26.COV2.S). Herein, we present the case of a healthy 39-year-old patient with VITT after having received the vaccine Ad26.COV2.S. Ten days after vaccination, the patient developed a deep vein thrombosis and subsequent pulmonary embolism. A computed tomography scan of the abdomen showed adrenal gland bleeding and an adrenocorticotrophic hormone stimulation test diagnosed adrenal insufficiency. Therapy with intravenous immunoglobulin, argatroban and hydrocortisone was initiated immediately after diagnosis. The patient left the hospital 22 days after admission with the diagnosis of adrenal insufficiency but otherwise in good health. To the best of our knowledge, five cases of VITT and adrenal bleeding have been described to date in the literature but the presented case was the first to occur after immunisation with the vaccine of Johnson & Johnson. In summary, VITT-associated adrenal dysfunction is a very rare complication of vaccination with an adenoviral vector-based COVID-19 vaccine.

2.
Catheter Cardiovasc Interv ; 99(4): 1259-1267, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084083

RESUMEN

BACKGROUND: Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program. METHODS: A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single-center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol. RESULTS: Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366-1231] vs. 2265 [1517-3914] cGy·cm2 , p < 0.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (p < 0.001), reducing dose area product by 64% (95% confidence interval [57-70]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow-up. CONCLUSION: Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Exposición a la Radiación , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA