Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Med Biol ; 69(10)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38588671

RESUMEN

Objective. A novel x-ray field produced by an ultrathin conical target is described in the literature. However, the optimal design for an associated collimator remains ambiguous. Current optimization methods using Monte Carlo calculations restrict the efficiency and robustness of the design process. A more generic optimization method that reduces parameter constraints while minimizing computational load is necessary. A numerical method for optimizing the longitudinal collimator hole geometry for a cylindrically-symmetrical x-ray tube is demonstrated and compared to Monte Carlo calculations.Approach. The x-ray phase space was modelled as a four-dimensional histogram differential in photon initial position, final position, and photon energy. The collimator was modeled as a stack of thin washers with varying inner radii. Simulated annealing was employed to optimize this set of inner radii according to various objective functions calculated on the photon flux at a specified plane.Main results. The analytical transport model used for optimization was validated against Monte Carlo calculations using Geant4 via its wrapper, TOPAS. Optimized collimators and the resulting photon flux profiles are presented for three focal spot sizes and five positions of the source. Optimizations were performed with multiple objective functions based on various weightings of precision, intensity, and field flatness metrics. Finally, a select set of these optimized collimators, plus a parallel-hole collimator for comparison, were modeled in TOPAS. The evolution of the radiation field profiles are presented for various positions of the source for each collimator.Significance. This novel optimization strategy proved consistent and robust across the range of x-ray tube settings regardless of the optimization starting point. Common collimator geometries were re-derived using this algorithm while simultaneously optimizing geometry-specific parameters. The advantages of this strategy over iterative Monte Carlo-based techniques, including computational efficiency, radiation source-specificity, and solution flexibility, make it a desirable optimization method for complex irradiation geometries.


Asunto(s)
Método de Montecarlo , Rayos X , Fotones , Modelos Teóricos
2.
Int J Radiat Oncol Biol Phys ; 116(2): 295-304, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35235854

RESUMEN

PURPOSE: The American Association of Physicists in Medicine (AAPM) shares the results, conclusions, and recommendations from the initial Equity, Diversity, and Inclusion Climate Survey conducted in 2021. METHODS AND MATERIALS: The climate survey targeted medical physicists who are full members of the AAPM and included demographic inquiries and questions intended to assess the working environmental climate in terms of a sense of belonging and inclusion, experiences of discrimination and harassment, and obstacles to participation within the AAPM. The survey invitation was sent to 5,500 members. Responses were collected from 1385 members (response rate of 25%) between January and February 2021. RESULTS: Overall, the medical physics workplace climate was positive. However, some demographic and professional subgroups reported lower levels of agreement with positive characteristics of their workplace climates. Compared with men, women ranked lower 7 of 8 categories that characterized the workplace climate. Other subgroups that also ranked the workplace climate descriptors lower included individuals not originally from the United States and Canada (3/8). Most respondents strongly agreed/agreed that the climate within the AAPM was welcoming. However, 17% of respondents reported personally experiencing or witnessing microaggressions within the AAPM. Overall, medical physicists reported low levels of agreement that opportunities within the AAPM were available to them, from 34% to 60% among 8 categories, including opportunities to volunteer, join committees, and compete for leadership positions within the AAPM. Several subgroups reported even lower levels of agreement that these opportunities are available. Asian and Asian American respondents (3/8) and physicists with origins in countries outside the United States and Canada (7/8) reported fewer opportunities to participate in the AAPM. Medical physicists reported their experiences of discrimination and sexual harassment in their workplaces and within the AAPM. For those who reported personal experiences of sexual harassment, only 24% (15/63) felt comfortable reporting when it occurred within their workplaces, and 35% (9/26) felt comfortable reporting when it occurred within the AAPM. CONCLUSIONS: The report concludes with several recommendations for action.


Asunto(s)
Medicina , Acoso Sexual , Masculino , Humanos , Femenino , Estados Unidos , Física Sanitaria , Diversidad, Equidad e Inclusión , Encuestas y Cuestionarios
3.
Front Cell Infect Microbiol ; 12: 1011692, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36250048

RESUMEN

The Plasmodium vivax reticulocyte invasion process is still poorly understood, with only a few receptor-ligand interactions identified to date. Individuals with the Southeast Asian ovalocytosis (SAO) phenotype have a deletion in the band 3 protein on the surface of erythrocytes, and are reported to have a lower incidence of clinical P. vivax malaria. Based on this observation, band 3 has been put forward as a receptor for P. vivax invasion, although direct proof is still lacking. In this study, we combined functional ex vivo invasion assays and transcriptome sequencing to uncover a band 3-mediated invasion pathway in P. vivax and potential band 3 ligands. Invasion by P. vivax field isolates was 67%-71% lower in SAO reticulocytes compared with non-SAO reticulocytes. Reticulocyte invasion was decreased by 40% and 27%-31% when blocking with an anti-band 3 polyclonal antibody and a PvTRAg38 peptide, respectively. To identify new band 3 receptor candidates, we mRNA-sequenced schizont-stage isolates used in the invasion assays, and observed high transcriptional variability in multigene and invasion-related families. Transcriptomes of isolates with low or high dependency on band 3 for invasion were compared by differential expression analysis, which produced a list of band 3 ligand candidates with high representation of PvTRAg genes. Our ex vivo invasion assays have demonstrated that band 3 is a P. vivax invasion receptor and confirm previous in vitro studies showing binding between PvTRAg38 and band 3, although the lower and variable inhibition levels observed suggest the involvement of other ligands. By coupling transcriptomes and invasion phenotypes from the same isolates, we identified a list of band 3 ligand candidates, of which the overrepresented PvTRAg genes are the most promising for future research.


Asunto(s)
Malaria Vivax , Plasmodium vivax , Proteína 1 de Intercambio de Anión de Eritrocito/metabolismo , Antígenos de Protozoos , Eliptocitosis Hereditaria , Eritrocitos , Humanos , Ligandos , Malaria Vivax/genética , Péptidos/metabolismo , Proteínas Protozoarias/metabolismo , ARN Mensajero/metabolismo , Reticulocitos/metabolismo
4.
Med Phys ; 49(9): 5742-5751, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35866442

RESUMEN

PURPOSE: To fully automate CT-based cervical cancer radiotherapy by automating contouring and planning for three different treatment techniques. METHODS: We automated three different radiotherapy planning techniques for locally advanced cervical cancer: 2D 4-field-box (4-field-box), 3D conformal radiotherapy (3D-CRT), and volumetric modulated arc therapy (VMAT). These auto-planning algorithms were combined with a previously developed auto-contouring system. To improve the quality of the 4-field-box and 3D-CRT plans, we used an in-house, field-in-field (FIF) automation program. Thirty-five plans were generated for each technique on CT scans from multiple institutions and evaluated by five experienced radiation oncologists from three different countries. Every plan was reviewed by two of the five radiation oncologists and scored using a 5-point Likert scale. RESULTS: Overall, 87%, 99%, and 94% of the automatically generated plans were found to be clinically acceptable without modification for the 4-field-box, 3D-CRT, and VMAT plans, respectively. Some customizations of the FIF configuration were necessary on the basis of radiation oncologist preference. Additionally, in some cases, it was necessary to renormalize the plan after it was generated to satisfy radiation oncologist preference. CONCLUSION: Approximately, 90% of the automatically generated plans were clinically acceptable for all three planning techniques. This fully automated planning system has been implemented into the radiation planning assistant for further testing in resource-constrained radiotherapy departments in low- and middle-income countries.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Neoplasias del Cuello Uterino , Femenino , Humanos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia
5.
J Appl Clin Med Phys ; 23(8): e13647, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35580067

RESUMEN

PURPOSE: To determine the most accurate similarity metric when using an independent system to verify automatically generated contours. METHODS: A reference autocontouring system (primary system to create clinical contours) and a verification autocontouring system (secondary system to test the primary contours) were used to generate a pair of 6 female pelvic structures (UteroCervix [uterus + cervix], CTVn [nodal clinical target volume (CTV)], PAN [para-aortic lymph nodes], bladder, rectum, and kidneys) on 49 CT scans from our institution and 38 from other institutions. Additionally, clinically acceptable and unacceptable contours were manually generated using the 49 internal CT scans. Eleven similarity metrics (volumetric Dice similarity coefficient (DSC), Hausdorff distance, 95% Hausdorff distance, mean surface distance, and surface DSC with tolerances from 1 to 10 mm) were calculated between the reference and the verification autocontours, and between the manually generated and the verification autocontours. A support vector machine (SVM) was used to determine the threshold that separates clinically acceptable and unacceptable contours for each structure. The 11 metrics were investigated individually and in certain combinations. Linear, radial basis function, sigmoid, and polynomial kernels were tested using the combinations of metrics as inputs for the SVM. RESULTS: The highest contouring error detection accuracies were 0.91 for the UteroCervix, 0.90 for the CTVn, 0.89 for the PAN, 0.92 for the bladder, 0.95 for the rectum, and 0.97 for the kidneys and were achieved using surface DSCs with a thickness of 1, 2, or 3 mm. The linear kernel was the most accurate and consistent when a combination of metrics was used as an input for the SVM. However, the best model accuracy from the combinations of metrics was not better than the best model accuracy from a surface DSC as an input. CONCLUSIONS: We distinguished clinically acceptable contours from clinically unacceptable contours with an accuracy higher than 0.9 for the targets and critical structures in patients with cervical cancer; the most accurate similarity metric was surface DSC with a thickness of 1, 2, or 3 mm.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Femenino , Humanos , Ganglios Linfáticos , Pelvis , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos
6.
Mutat Res ; 824: 111772, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34923215

RESUMEN

The study of radiation effects on biological tissues is a diverse field of research with direct applications to improve human health, in particular in the contexts of radiation therapy and space exploration. Understanding the DNA damage response following radiation exposure, which is a key determinant for mutagenesis, requires reproducible methods for delivering known doses of ionizing radiation (IR) in a controlled environment. Multiple IR sources, including research X-ray and gamma-ray irradiators are routinely used in basic and translational research with cell and animal models. These systems are however not ideal when a high temporal resolution is needed, for example to study early DNA damage responses with live cell microscopy. Here, we characterize the dose rate and beam properties of a commercial, miniature, affordable, and versatile X-ray source (Mini-X). We describe how to use Mini-X on the stage of a fluorescence microscope to deliver high IR dose rates (up to 29 Gy/min) or lower dose rates (≤ 0.1 Gy/min) in live cell imaging experiments. This article provides a blueprint for radiation biology applications with high temporal resolution, with a step-by-step guide to implement a miniature X-ray system on an imaging platform, and the information needed to characterize the system.


Asunto(s)
Microscopía , Radiobiología , Animales , Radiación Ionizante , Rayos X
7.
Lancet Oncol ; 22(12): 1732-1739, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34717797

RESUMEN

BACKGROUND: The role of radiotherapy in metastatic renal cell carcinoma is controversial. We prospectively tested the feasibility and efficacy of radiotherapy to defer systemic therapy for patients with oligometastatic renal cell carcinoma. METHODS: This single-arm, phase 2, feasibility trial was done at one centre in the USA (The MD Anderson Cancer Center, Houston, TX, USA). Patients (aged ≥18 years) with five or fewer metastatic lesions, an Eastern Cooperative Oncology Group status of 0-2, and no more than one previous systemic therapy (if this therapy was stopped at least 1 month before enrolment) without limitations on renal cell carcinoma histology were eligible for inclusion. Patients were treated with stereotactic body radiotherapy (defined as ≤5 fractions with ≥7 Gy per fraction) to all lesions and maintained off systemic therapy. When lesion location precluded safe stereotactic body radiotherapy, patients were treated with hypofractionated intensity-modulated radiotherapy regimes consisting of 60-70 Gy in ten fractions or 52·5-67·5 Gy in 15 fractions. Additional rounds of radiotherapy were allowed to treat subsequent sites of progression. Co-primary endpoints were feasibility (defined as all planned radiotherapy completed with <7 days unplanned breaks) and progression-free survival. All efficacy analyses were intention-to-treat. Safety was analysed in the as-treated population. A second cohort, with the aim of assessing the feasibility of sequential stereotactic body radiotherapy alone in patients with low-volume metastatic disease, was initiated and will be reported separately. This study is registered with ClinicalTrials.gov, NCT03575611. FINDINGS: 30 patients (six [20%] women) were enrolled from July 13, 2018, to Sept 18, 2020. All patients had clear cell histology and had a nephrectomy before enrolment. All patients completed at least one round of radiotherapy with less than 7 days of unplanned breaks. At a median follow-up of 17·5 months (IQR 13·2-24·6), median progression-free survival was 22·7 months (95% CI 10·4-not reached; 1-year progression-free survival 64% [95% CI 48-85]). Three (10%) patients had severe adverse events: two grade 3 (back pain and muscle weakness) and one grade 4 (hyperglycaemia) adverse events were observed. There were no treatment-related deaths. INTERPRETATION: Sequential radiotherapy might facilitate deferral of systemic therapy initiation and could allow sustained systemic therapy breaks for select patients with oligometastatic renal cell carcinoma. FUNDING: Anna Fuller Foundation, the Cancer Prevention and Research Institute of Texas (CPRIT), and the National Cancer Institute.


Asunto(s)
Carcinoma de Células Renales/radioterapia , Neoplasias Renales/radioterapia , Radioterapia de Intensidad Modulada/mortalidad , Anciano , Carcinoma de Células Renales/epidemiología , Carcinoma de Células Renales/patología , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Renales/epidemiología , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Pronóstico , Tasa de Supervivencia , Texas/epidemiología
8.
Int J Part Ther ; 7(2): 11-20, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33274253

RESUMEN

PURPOSE: To determine the clinical outcomes and toxicities of proton beam therapy (PBT) versus 3D-conformal photon radiation therapy (XRT) in patients with testicular seminoma. MATERIALS AND METHODS: This observational study evaluated consecutive patients with testicular seminoma who were treated with inguinal orchiectomy and radiation therapy at a single, tertiary, high-volume center in 2008-19. Acute toxicity was scored with the Common Terminology Criteria for Adverse Events V 4.0. Organs at risk were contoured retrospectively by 2 investigators. Recurrences and secondary malignancies were based on routine follow-up imaging, either computed tomography or magnetic resonance imaging. RESULTS: Fifty-five patients were treated with radiation therapy, 11 in the PBT-arm and 44 in the XRT-arm, with a median follow-up interval of 61 months (interquartile range [IQR]: 32-79 months). Acute treatment-related diarrhea, grade 1 to 2, was more common among XRT-treated patients (0% vs 29.5%, P = .039), and dermatitis, grade 1, was more likely among PBT-treated patients (27.3% vs 2.3%, P = .004). Dosimetrically, PBT-treated patients, relative to XRT-treated patients, had lower dose to organs at risk including the kidney, bladder, femoral head, spinal cord, bowel, pancreas, and stomach. The 5-year overall survival rate was 100% and disease-free survival rate was 96.4% for all patients. Two patients, all in the XRT-arm, had disease recurrence: 1 in the pelvis and 1 in the lung. Three patients, all in the XRT-arm, were diagnosed with a secondary malignancy: 1 in-field pancreaticoblastoma, 1 in-field colon adenocarcinoma, and a stage IV T-cell lymphoma. CONCLUSION: Proton beam therapy for testicular seminoma resulted in excellent clinical outcomes and was associated with lower rates of acute diarrhea but higher rates of acute dermatitis. Proton beam therapy resulted in no in-field secondary malignancies and a more favorable dosimetric profile for organs at risk relative to XRT. Reduced dose to organs at risk, such as the kidneys, may result in long-term improvement in function.

9.
J Radiosurg SBRT ; 6(2): 161-163, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31641553

RESUMEN

Splenic metastases from oligometastatic ovarian carcinoma are a rare occurrence. Usual treatment for splenic metastases includes splenectomy, but some patients are either unable or unwilling to undergo surgery. Stereotactic body radiotherapy (SBRT) is an effective ablative modality for treating metastatic disease. SBRT to abdominopelvic tumors has been shown to be safe and effective for properly-selected patients and is particularly attractive in the oligometastatic setting as an alternative to radical resection. In this case study, we report a patient with an isolated splenic metastasis from ovarian carcinoma treated with 50 Gy in 10 fractions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA