Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Refract Surg ; 40(3): e142-e147, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38466767

RESUMEN

PURPOSE: To evaluate the accuracy of the Reinstein formula with hand-held ultrasound biomicroscopy (UBM) measurements for sizing of the Implantable Collamer Lens (ICL). METHODS: A total of 107 myopic eyes of 57 patients implanted with the ICL were included in the study. The size of the ICL was selected based on the manufacturer's recommendations. Agreement between the vault predicted by the Reinstein formula and the vault measured postoperatively was analyzed with Bland-Altman plots. RESULTS: A total of 95% and 81% of patients had a postoperative vault ranging from 150 to 1,000 and 250 to 750 µm, respectively. The mean vault predicted by the Reinstein formula and the postoperative vault in the current study were 580 ± 181 and 547 ± 200 µm, respectively. The size recommendations of the Reinstein formula and the formula provided by the manufacturer, the Kojima formula, and the Dougherty formula overlapped in 50%, 57%, and 49% of eyes, respectively. CONCLUSIONS: The results show that the Reinstein formula combined with a hand-held UBM provides reliable sizing predictions of the ICL. However, considering that robotic UBM measurements have demonstrated a narrower range of deviation in predicting vault depth in previous studies, a direct comparison study between robotic UBM and hand-held UBM measurements is necessary to fully assess the limitations of combining hand-held UBM with the Reinstein formula. [J Refract Surg. 2024;40(3):e142-e147.].


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Microscopía Acústica/métodos , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Miopía/cirugía , Estudios Retrospectivos
2.
BMC Ophthalmol ; 20(1): 28, 2020 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-31941474

RESUMEN

BACKGROUND: Corneal infections with antibiotic-resistant microorganisms are an increasingly difficult management challenge and chemically or photochemically cross-linking the cornea for therapy presents a unique approach to managing such infections since both direct microbial pathogens killing and matrix stabilization can occur simultaneously. The present study was undertaken in order to compare the anti-microbial efficacy, in vitro, of 5 candidate cross-linking solutions against 5 different microbial pathogens with relevance to infectious keratitis. METHODS: In vitro bactericidal efficacy studies were carried out using 5 different FARs [diazolidinyl urea (DAU), 1,3-bis(hydroxymethyl)-5,5-dimethylimidazolidine-2,4-dione (DMDM), sodium hydroxymethylglycinate (SMG), 2-(hydroxymethyl)-2-nitro-1,3-propanediol (NT = nitrotriol), 2-nitro-1-propanol (NP)] against 5 different microbial pathogens including two antibiotic-resistant species [methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), Pseudomonas aeruginosa (PA), and Candida albicans (CA)]. Standard in vitro antimicrobial testing methods were used. RESULTS: The results for MSSA were similar to those for MRSA. DAU, DMDM, and SMG all showed effectiveness with greater effects generally observed with longer incubation times and higher concentrations. Against MRSA, 40 mM SMG at 120 min showed a > 95% kill rate, p < 0.02. Against VRE, 40 mM DAU for 120 min showed a > 94% kill rate, p < 0.001. All FARs showed bactericidal effect against Pseudomonas aeruginosa, making PA the most susceptible of the strains tested. Candida showed relative resistance to these compounds, requiring high concentrations (100 mM) to achieve kill rates greater than 50%. CONCLUSION: Our results show that each FAR compound has different effects against different cultures. Our antimicrobial armamentarium could potentially be broadened by DAU, DMDM, SMG and other FARs for antibiotic-resistant keratitis. Further testing in live animal models are indicated.


Asunto(s)
Antibacterianos/farmacología , Antifúngicos/farmacología , Bacterias/efectos de los fármacos , Candida albicans/efectos de los fármacos , Formaldehído/metabolismo , Úlcera de la Córnea/tratamiento farmacológico , Úlcera de la Córnea/microbiología , Resistencia a Medicamentos , Farmacorresistencia Bacteriana , Infecciones Bacterianas del Ojo/tratamiento farmacológico , Infecciones Bacterianas del Ojo/microbiología , Infecciones Fúngicas del Ojo/tratamiento farmacológico , Infecciones Fúngicas del Ojo/microbiología , Pruebas de Sensibilidad Microbiana , Nitrocompuestos/farmacología , Propanoles/farmacología , Sarcosina/análogos & derivados , Sarcosina/farmacología , Trometamina/análogos & derivados , Trometamina/farmacología , Urea/análogos & derivados , Urea/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA