Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627820

RESUMEN

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Factores de Riesgo , Progresión de la Enfermedad
2.
J Cardiothorac Surg ; 19(1): 95, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355617

RESUMEN

BACKGROUND: Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS: This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS: There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS: The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estudios Retrospectivos , Estudios de Cohortes , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
3.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-37522885

RESUMEN

OBJECTIVES: The aim of this study was to develop a method to quantify the peel force in an in vitro model simulating repair of ascending aortic dissections with tissue glue (Bioglue). METHODS: This study adapted an adhesive T-Peel test for the determination of the peel strength of adhesives by measuring the peeling force of a T-shaped bonded tissue. Measurements were performed on iatrogenic dissected ascending porcine aorta, which has been repaired with Bioglue using different pressure levels. Four conditions were tested: zero sample pressure according to the manufacturer's recommendation (n = 10), low (504 Pa; n = 11), moderate pressure (1711 Pa; n = 24) and pressure applied by a round shaped vascular 'Borst clamp' (1764 Pa; n = 23). Non-parametric one-way analysis of variance was applied for statistical significance. RESULTS: The median peel force (lower quartile, upper quartile) of aortic samples increased depending on the applied pressure: [no pressure 0.030 N/mm (0.016, 0.057), low pressure 0.040 N/mm (0.032, 0.070) and moderate pressure 0.214 N/mm (0.050, 0.304)]. Samples pressurized with the Borst clamp reached 0.078 N/mm (0.046, 0.152), which was comparable to the peel force of the unpeeled controls [0.107 N/mm (0.087, 0.124)]. Compared to samples without pressure, Bioglue with the application of the Borst clamp (P = 0.021) and with moderate pressure (P = 0.0007) performed significantly better. CONCLUSIONS: The novel T-Peel test offers an attractive method to test tissue glues in defined in vitro environments. Bioglue peel force increased with pressure on the aortic sample in contrast to low or no pressure as per the manufacturer's recommendation. Modifying current recommended use may aid in increasing effectiveness of this approach.


Asunto(s)
Disección de la Aorta Ascendente , Adhesivos Tisulares , Porcinos , Animales , Adhesivos , Adhesivos Tisulares/farmacología , Aorta/cirugía
4.
Eur J Heart Fail ; 24(5): 899-907, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35064722

RESUMEN

AIMS: Transcatheter mitral valve implantation (TMVI) is a new treatment option for patients with symptomatic mitral valve (MV) disease. Real-world data have not yet been reported. This study aimed to assess procedural and 30-day outcomes of TMVI in a real-world patient cohort. METHOD AND RESULTS: All consecutive patients undergoing implantation of a transapically delivered self-expanding valve at 26 European centres from January 2020 to April 2021 were included in this retrospective observational registry. Among 108 surgical high-risk patients included (43% female, mean age 75 ± 7 years, mean STS-PROM 7.2 ± 5.3%), 25% was treated for an off-label indication (e.g. previous MV intervention or surgery, mitral stenosis, mitral annular calcification). Patients were highly symptomatic (New York Heart Association [NYHA] functional class III/IV in 86%) and mitral regurgitation (MR) was graded 3+/4+ in 95% (38% primary, 37% secondary, and 25% mixed aetiology). Technical success rate was 96%, and MR reduction to ≤1+ was achieved in all patients with successful implantation. There were two procedural deaths and 30-day all-cause mortality was 12%. At early clinical follow-up, MR reduction was sustained and there were significant reductions of pulmonary pressure (systolic pulmonary artery pressure 52 vs. 42 mmHg, p < 0.001), and tricuspid regurgitation severity (p = 0.013). Heart failure symptoms improved significantly (73% in NYHA class I/II, p < 0.001). Procedural success rate according to MVARC criteria was 80% and was not different in patients treated for an off-label indication (74% vs. 81% for off- vs. on-label, p = 0.41). CONCLUSION: In a real-world patient population, TMVI has a high technical and procedural success rate with efficient and durable MR reduction and symptomatic improvement.


Asunto(s)
Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Femenino , Insuficiencia Cardíaca/etiología , Enfermedades de las Válvulas Cardíacas/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
5.
Asian Cardiovasc Thorac Ann ; 30(6): 635-644, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35014877

RESUMEN

OBJECTIVE: Deep hypothermic circulatory arrest (DHCA) in aortic surgery is associated with morbidity and mortality despite evolving strategies. With the advent of antegrade cerebral perfusion (ACP), moderate hypothermic circulatory arrest (MHCA) was reported to have better outcomes than DHCA. There is no standardised guideline or consensus regarding the hypothermic strategies to be employed in open aortic surgery. Meta-analysis was performed comparing DHCA with MHCA + ACP in patients having aortic surgery. METHODS: A systematic review of the literature was undertaken. Any studies with DHCA versus MHCA + ACP in aortic surgeries were selected according to specific inclusion criteria and analysed to generate summative data. Statistical analysis was performed using STATS Direct. The primary outcomes were hospital mortality and post-operative stroke. Secondary outcomes were cardiopulmonary bypass time (CPB), post-operative blood transfusion, length of ICU stay, respiratory complications, renal failure and length of hospital stay. Subgroup analysis of primary outcomes for Arch surgery alone was also performed. RESULTS: Fifteen studies were included with a total of 5869 patients. There was significantly reduced mortality (Pooled OR = +0.64, 95% CI = +0.49 to +0.83; p = 0.0006) and stroke rate (Pooled OR = +0.62, 95% CI = +0.49 to +0.79; p < 0.001) in the MHCA group. MHCA was associated significantly with shorter CPB times, shorter duration in ICU, less pulmonary complications, and reduced rates of sepsis. There was no statistical difference between the two groups in terms of circulatory arrest times, X-Clamp times, total operation duration, transfusion requirements, renal failure and post-op hospital stay. CONCLUSION: MHCA + ACP are associated with significantly better post-operative outcomes compared with DHCA for both mortality and stroke and majority of the secondary outcomes.


Asunto(s)
Paro Cardíaco , Insuficiencia Renal , Accidente Cerebrovascular , Aorta Torácica/cirugía , Circulación Cerebrovascular , Paro Circulatorio Inducido por Hipotermia Profunda/efectos adversos , Humanos , Perfusión/efectos adversos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
7.
J Cardiothorac Surg ; 16(1): 355, 2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-34961528

RESUMEN

BACKGROUND: Sutureless prostheses may have added benefit when combined with minimal access surgery, although this has not been fully assessed in the literature. This study aims to provide a comparative analysis of the Perceval valve comparing median sternotomy (MS) with mini-sternotomy (MIS). METHODS: A retrospective analysis of prospectively collected data was conducted for all isolated aortic valve replacement (AVR), using the Perceval valve, for severe aortic stenosis cases in the period 2014 to 2019. Patients undergoing concomitant valve or revascularisation surgery were excluded. RESULTS: A total of 78 patients were included: MS group 41; MIS group 37. Operatively, bypass times were comparable between MS and MIS groups (mean 89.3 vs 83.4, p = 0.307), as were aortic cross clamp times (58.4 vs 55.9, p = 0.434). There were no operative deaths or new onset post-operative neurology. MIS was a predictor of reduced stay in the intensive care unit (coef - 3.25, 95% CI [- 4.93, - 0.59], p = 0.036) and hospital stay overall (p = 0.004). Blood transfusion units were comparable as were the incidence of heart block (n = 5 vs n = 3, p = 0.429) and new onset atrial fibrillation (n = 15 vs n = 9, p = 0.250). Follow-up echocardiography found a significant improvement in effective orifice area, left ventricular dimension and volume indices, and LVEF (p > 0.05) for all patients. Multivariate analysis found mini-sternotomy to be a predictor for reduced LV diastolic volume (coef - 0.35, 95% CI [- 1.02, - 0.05], p = 0.05). CONCLUSIONS: The combination of minimal access surgery and sutureless AVR may enhance patient recovery and provide early LV remodelling.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Esternotomía , Resultado del Tratamiento
9.
BMC Cardiovasc Disord ; 21(1): 434, 2021 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-34521355

RESUMEN

BACKGROUND: The coronavirus-disease 2019 (COVID-19) pandemic imposed an unprecedented burden on the provision of cardiac surgical services. The reallocation of workforce and resources necessitated the postponement of elective operations in this cohort of high-risk patients. We investigated the impact of this outbreak on the aortic valve surgery activity at a single two-site centre in the United Kingdom. METHODS: Data were extracted from the local surgical database, including the demographics, clinical characteristics, and outcomes of patients operated on from March 2020 to May 2020 with only one of the two sites resuming operative activity and compared with the respective 2019 period. A similar comparison was conducted with the period between June 2020 and August 2020, when operative activity was restored at both institutional sites. The experience of centres world-wide was invoked to assess the efficiency of our services. RESULTS: There was an initial 38.2% reduction in the total number of operations with a 70% reduction in elective cases, compared with a 159% increase in urgent and emergency operations. The attendant surgical risk was significantly higher [median Euroscore II was 2.7 [1.9-5.2] in 2020 versus 2.1 [0.9-3.7] in 2019 (p = 0.005)] but neither 30-day survival nor freedom from major post-operative complications (re-sternotomy for bleeding/tamponade, transient ischemic attack/stroke, renal replacement therapy) was compromised (p > 0.05 for all comparisons). Recommencement of activity at both institutional sites conferred a surgical volume within 17% of the pre-COVID-19 era. CONCLUSIONS: Our institution managed to offer a considerable volume of aortic valve surgical activity over the first COVID-19 outbreak to a cohort of higher-risk patients, without compromising post-operative outcomes. A backlog of elective cases is expected to develop, the accommodation of which after surgical activity normalisation will be crucial to monitor.


Asunto(s)
Válvula Aórtica/cirugía , COVID-19 , Procedimientos Quirúrgicos Cardíacos/tendencias , Enfermedades de las Válvulas Cardíacas/cirugía , Evaluación de Procesos y Resultados en Atención de Salud/tendencias , Pautas de la Práctica en Medicina/tendencias , Cirujanos/tendencias , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Bases de Datos Factuales , Procedimientos Quirúrgicos Electivos/tendencias , Femenino , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Londres , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
Eur J Cardiothorac Surg ; 60(1): 34-46, 2021 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-33517391

RESUMEN

OBJECTIVES: We sought to provide further evidence on the safety and efficacy of aortic valve neocuspidization (AVNeo) using autologous pericardium in adult patients with aortic valve disease by reporting clinical and echocardiographic results from the first UK experience and performing a meta-analytic comparison with other biological valve substitutes. METHODS: We reported clinical and echocardiographic outcomes of 55 patients (mean age 58 ± 15 years) undergoing AVNeo with autologous pericardium in 2 UK centres from 2018 to 2020. These results were included in a meta-analytic comparison between series on AVNeo (7 studies, 1205 patients, mean weighted follow-up 3.6 years) versus Trifecta (10 studies, 8705 patients, 3.8 years), Magna Ease (3 studies, 3137 patients, 4.1 years), Freedom Solo (4 studies, 1869 patients, 4.4 years), Freestyle (4 studies, 4307 patients, 7 years), Mitroflow (4 studies, 4760 patients, 4.1 years) and autograft aortic valve (7 papers, 3839 patients, 9.1 years). RESULTS: In the present series no patients required intraoperative conversion. After mean follow-up of 12.5 ± 0.9 months, 3 patients presented with endocarditis and 1 required reintervention. The remaining patients had absent or mild aortic valve insufficiency with very low peak and mean transvalvular gradients (16 ± 3.7 and 9 ± 2.2 mmHg, respectively). Meta-analytic estimates showed non-significant difference between AVNeo and all but Magna Ease valves with regards to structural valve degeneration, reintervention and endocarditis. When compared Magna Ease valve, AVNeo and other valve substitutes showed an excess of valve-related events. CONCLUSIONS: AVNeo is safe, associated with excellent haemodynamic profile. Its midterm risk of valve-related events is comparable to most biological valve substitutes. Magna Ease is potentially the best biological choice as far as risk of reintervention is concerned.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Persona de Mediana Edad , Pericardio/cirugía , Pericardio/trasplante , Diseño de Prótesis , Resultado del Tratamiento , Reino Unido/epidemiología
11.
Respir Med Case Rep ; 29: 100993, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31908919

RESUMEN

A 31-year-old female was referred with a history of unexplained exertional breathlessness. The patient had normal resting lung function and a CT thorax showed no significant abnormality. Closer scrutiny of the flow-volume loop confirmed an elevated Empey's index. Cardiopulmonary exercise testing with continuous laryngoscopy was conducted to evaluate the upper airway response to exercise which confirmed loud biphasic wheeze. A bronchoscopy revealed no stenosis nor intraluminal narrowing, however, a contrast CT confirmed a right-sided aortic arch and aberrant left subclavian artery. Following multidisciplinary review, the patient opted for a surgical approach to treatment however despite initially reporting an improvement in symptoms and exercise capacity continued to suffer exertional wheeze two-years post-surgery. This clinical report describes a rare vascular cause of exertional wheeze but also provides a cautionary note in terms of providing a guarded prognosis for adults undergoing surgical intervention for tracheal compression arising from congenital vascular abnormalities.

12.
World J Pediatr Congenit Heart Surg ; 10(6): 724-730, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31701826

RESUMEN

BACKGROUND: The Ozaki procedure is a surgical technique for patients with significant aortic stenosis or regurgitation or both where valve repair cannot be performed. Individual cusps are cut from glutaraldehyde-treated autologous pericardium or bovine pericardium and implanted into the aortic valve position. Encouraging results have been reported within the adult population. There are limited published data on success of this procedure in younger patients. METHODS: We present a series of five children and young adults who underwent the Ozaki procedure with neoaortic valve cusps made from CardioCel, a decellularized bovine pericardial patch treated with a monomeric glutaraldehyde. RESULTS: There were no complications in the initial postoperative period and short inpatient stay. At a mean follow-up of 29.6 months (range: 22-36 months), 4 patients had no evidence of stenosis and 3 patients had trivial or no regurgitation from the neoaortic valve. Overall, two patients had complications related to the valve and underwent reintervention during the follow-up period with a Ross procedure. One of these patients who was not taking long-term anticoagulation experienced a transient ischemic attack. CONCLUSIONS: Our experience demonstrates that the Ozaki procedure with CardioCel in pediatric and young adult patients should be approached with caution. Further research with larger groups of pediatric patients, comparison of different graft materials, and longer follow-up is required to ascertain long-term success in children.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Pericardio/trasplante , Adolescente , Adulto , Animales , Bovinos , Niño , Femenino , Humanos , Masculino , Estudios Retrospectivos , Trasplante Autólogo , Adulto Joven
13.
Braz J Cardiovasc Surg ; 34(5): 610-614, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31719012

RESUMEN

In cases of aortic valve disease, prosthetic valves have been increasingly used for valve replacement, however, there are inherent problems with prostheses, and their quality in the so-called Third World countries is lower in comparison to new-generation models, which leads to shorter durability. Recently, transcatheter aortic valve replacement has been explored as a less invasive option for patients with high-risk surgical profile. In this scenario, aortic valve neocuspidization (AVNeo) has emerged as another option, which can be applied to a wide spectrum of aortic valve diseases. Despite the promising results, this procedure is not widely spread among cardiac surgeons yet. Spurred on by the last publications, we went on to write an overview of the current practice of state-of-the-art AVNeo and its results.


Asunto(s)
Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Glutaral/uso terapéutico , Enfermedades de las Válvulas Cardíacas/cirugía , Pericardio/trasplante , Trasplante Autólogo/métodos , Humanos , Reoperación , Resultado del Tratamiento
14.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;34(5): 610-614, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1042030

RESUMEN

Abstract In cases of aortic valve disease, prosthetic valves have been increasingly used for valve replacement, however, there are inherent problems with prostheses, and their quality in the so-called Third World countries is lower in comparison to new-generation models, which leads to shorter durability. Recently, transcatheter aortic valve replacement has been explored as a less invasive option for patients with high-risk surgical profile. In this scenario, aortic valve neocuspidization (AVNeo) has emerged as another option, which can be applied to a wide spectrum of aortic valve diseases. Despite the promising results, this procedure is not widely spread among cardiac surgeons yet. Spurred on by the last publications, we went on to write an overview of the current practice of state-of-the-art AVNeo and its results.


Asunto(s)
Humanos , Válvula Aórtica/cirugía , Pericardio/trasplante , Trasplante Autólogo/métodos , Glutaral/uso terapéutico , Anuloplastia de la Válvula Cardíaca/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Reoperación , Resultado del Tratamiento
15.
Semin Thorac Cardiovasc Surg ; 31(4): 686-690, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30980933

RESUMEN

Diseases of the thoracic aorta are increasing in prevalence worldwide. Recent data indicated wide regional variation in the volume and complexity of aortic cases undertaken in United Kingdom cardiac centers, especially in case of acute type A aortic dissection (ATAAD) conditions. Patients treated in high-volume centers with a specific multidisciplinary aortic program had a significant reduction in ATAAD mortality when compared with low-volume centers. Following the initial phase of a national aortic center reorganization, the current study reflects the initial experience of a national collective of cardiothoracic surgeons with expertise in complex aortic surgery, using frozen elephant trunk as standard technique for the surgical treatment of patients affected by ATAAD. Between June 2013 and October 2017, 66 ATAAD patients (45% women) underwent hybrid aortic arch and frozen elephant trunk repair with the Thoraflex hybrid graft at 8 UK high-volume aortic centers. The in-hospital mortality accounted for 8 patients (12%). Postoperative temporary or permanent neurologic events and temporary renal replacement therapy occurred in 17% and 20% of patients, respectively. No spinal cord injury events were documented. Our data were similar to those reported in literature in the 2 largest experiences with the use of frozen elephant technique in ATAAD condition (in-hospital/30-day mortality: 11-12%). This initial experience demonstrated that frozen elephant technique can potentially be adopted as standard approach in life-threatening aortic diseases, with acceptable complication and mortality rates.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento , Reino Unido
16.
Eur J Cardiothorac Surg ; 55(5): 984-989, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30481302

RESUMEN

OBJECTIVES: Acute type A aortic dissection is an emergency associated with up to 30% of hospital mortality. It has been established that outcomes are improved with specialist aortic team care in high-volume centres. Most centres are limited to a small number of aortic specialists, thus making it logistically impractical to have a dedicated 24/7 single-centre service. In 2011, a rotational 24/7 service between 3 centres covering a geographical location was introduced including 24/7 access to a dissection 'Hotline'. METHODS: We analysed data since 2003 from a prospectively collected database. A total of 227 patients underwent surgery for acute aortic syndrome between 2003 and 2017. The results on outcomes were compared before and after the initiation of the dissection hotline and 24/7 dedicated service. RESULTS: We identified 128 patients from the pre-rotational group and 99 patients from the post-rotational group. Both groups were well matched in terms of demographics and comorbidities. In the post-rotational group, there was an increase in arch surgery (11.8% vs 20.2%, P: 0.07). The introduction of the rotational service reduced 30-day mortality (20% vs 8%, P: 0.010). The introduction of the service improved the overall long-term survival [P: 0.04, hazard ratio 1.86; confidence interval (1.03-3.38)] in the multivariable analysis. There was no difference between the groups in postoperative complications. There was an increase in the median length of hospital stay in the post-rotational group (13 days vs 20 days, P: 0.014). CONCLUSIONS: A streamlined aortic dissection service allows for centralized care. This provides the referring centres with 24/7 access to an experienced aortic team and may improve patient outcomes.


Asunto(s)
Aneurisma de la Aorta , Disección Aórtica , Cirujanos/provisión & distribución , Cirugía Torácica/organización & administración , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/mortalidad , Disección Aórtica/cirugía , Aorta/cirugía , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Admisión y Programación de Personal , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos
17.
J Cardiol Cases ; 17(6): 183-186, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30279887

RESUMEN

The combination of aortic stenosis in the context of bicuspid aortic valve, aneurysmal dilatation of the ascending aorta, and coarctation is not uncommon. This condition has conventionally been addressed either by a complex open surgical approach or by staged hybrid approach combining open surgery of the ascending aorta with subsequent endovascular stenting of the coarctation. So far, the risk of a complex open approach for the aortic valve and ascending aorta and the cumulative risk of a staged second procedure for management of the coarctation are unknown; and similarly, the risk of a complex single-staged surgical procedure as an option instead of a single-staged hybrid approach is unknown. For the first time, we present a case of a patient with bicuspid aortopathy and concomitant coarctation who was simultaneously managed with both stenting of the coarctation and subsequent surgical replacement of the aortic valve and ascending aorta in one session. This new strategy has potential to become a future standard of care with various advantages. .

18.
J Thorac Cardiovasc Surg ; 153(2): S3-S11, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27692758

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown-this is important because in proximal (Stanford type A) aortic dissections, 10% to 30% are not accepted for surgery and 30% to 50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated by using TEVAR. METHODS: Between year 2009 and 2016, 12 patients with acute, subacute, or chronic type A aortic dissection with the proximal entry tear located between the coronaries and brachiocephalic artery were treated with TEVAR at 3 centers. Various stent-graft configurations were used to seal the proximal entry tear in the ascending aorta under rapid pacing. RESULTS: A total of 12 patients (9 male, 3 female), mean age 81 ± 7 years, EuroSCORE II 9.1 ± 4.5, underwent TEVAR for the treatment of type A aortic dissection. Procedural success was achieved in 11 of 12 patients (91.7%). There was 1 minor stroke and 1 intraprocedural death. No additional deaths were reported at 30 days. At 36 months, there were 4 further deaths (all from nonaortic causes). The mean survival of these 4 deceased was 23 months (range 15-36 months). Follow-up computed tomography demonstrated favorable aortic remodeling. CONCLUSIONS: TEVAR is feasible and reveals promising early results in selected patients with type A aortic dissection who are poor candidates for surgical repair. The current iteration of stent-graft technology, however, needs to be adapted to features specific to the ascending aorta.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Procedimientos Endovasculares/métodos , Stents , Procedimientos Quirúrgicos Torácicos/métodos , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Innovations (Phila) ; 11(3): 174-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27537190

RESUMEN

OBJECTIVE: A small number of transcatheter mitral valve implants (TMVIs) have been reported using devices designed to treat secondary mitral regurgitation (MR). However, MR has many etiologies, and patients have a broad spectrum of annular size, geometry, and lesions. There are a number of technical challenges for TMVI including left ventricular outflow tract obstruction and paravalvular MR. Thirty days' outcome of first-in-man implants with a novel TMVI device is reported. METHODS: The Tendyne TMVI system consists of a porcine pericardial valve in a tethered nitinol frame. An apical tether fixed to an epicardial pad stabilizes the device. The device is fully repositionable and retrievable even after complete deployment. Preoperative assessment was performed with 3-dimensional (3D) transesophageal echocardiogram and multislice computed tomography to define annular dimensions, geometry, and guide surgical access. Three patients were deemed not to be candidates for conventional surgery or for treatment with any Conformitè Européenne-marked device by Heart Team Evaluation. They were a 68-year-old woman with prior coronary artery bypass grafts and severe functional MR; a 75-year-old man with prior coronary bypass grafts, significant renal dysfunction, and severe degenerative MR; and a frail 86-year-old man with severe degenerative MR. Each had a TMVI via a transapical approach through a left minithoracotomy. Apical tether tension was adjusted to optimize device position. RESULTS: Implantation was guided by 2D and 3D transesophageal echocardiogram. The apical pad facilitated LV apical closure. There were no procedural complications. No patient had hemodynamically significant residual MR or left ventricular outflow tract obstruction, and there was no significant mitral gradient. All patients were discharged to their own home (the third on the fifth postoperative day), all with significant improvement in their symptoms. All were alive and well 30 days after implant. Two patients with existing conduction abnormalities had cardiac resynchronisation therapy after the procedure, and one patient had para valvular leak (PVL) with evidence of hemolysis at 30 days, which reduced in severity with conservative treatment. CONCLUSIONS: The first-in-man experience with the Tendyne TMVI system is promising. Valve stabilization by an apical tether is a novel way to address some of the challenges of TMVI. The unique Tendyne design features may offer potential for its use across a wide range of mitral valve pathologies.


Asunto(s)
Insuficiencia de la Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
20.
Can J Cardiol ; 32(8): 1039.e15-7, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26860773

RESUMEN

Metabolically active mediastinal brown adipose tissue may be mistakenly diagnosed as a malignancy on 18F-fluoro-2-deoxy-D-glucose (FDG)/positron emission tomography (PET). We report the case of a patient with locally recurrent breast carcinoma in which staging PET/CT revealed a suspicious pericardial lesion for which the patient was referred to our centre. The novelty of this case resides in the fact that by tissue characterization, cardiac magnetic resonance imaging allowed the determination that the lesion corresponded to brown fat, a reassuring finding with important impact on management, because the presence of pericardial metastasis would have disqualified this patient for curative resection of her cancer recurrence.


Asunto(s)
Tejido Adiposo Pardo/patología , Imagen por Resonancia Cinemagnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/secundario , Humanos , Pericardio/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA