1.
Medicine (Baltimore) ; 98(1): e13937, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30608424

RESUMEN

INTRODUCTION: Intensive care unit-acquired weakness (ICU-AW) is often observed in critically ill patients with prolonged intensive care unit (ICU) stay. We hypothesized that evolving metabolic abnormalities during prolonged ICU stay are reflected by changing nutrient patterns in blood, urine and skeletal muscle, and that these patterns differ in patients with/without ICU-AW and between patients with/without sepsis. METHODS: In a prospective single-center observational trial, we aim to recruit 100 critically ill patients (ICU length of stay ≥ 5 days) with severe sepsis/septic shock ("sepsis group", n = 50) or severe head trauma/intracerebral hemorrhage ("CNS group", n = 50). Patients will be sub-grouped for presence or absence of ICU-AW as determined by the Medical Research Council sum score. Blood and urine samples will be collected and subjected to comprehensive nutrient analysis at different time points by targeted quantitative mass spectrometric methods. In addition, changes in muscular tissue (biopsy, when available), muscular architecture (ultrasound), electrophysiology, body composition analyses (bioimpedance, cerebral magnetic resonance imaging), along with clinical status will be assessed. Patients will be followed-up for 180 and 360 days including assessment of quality of life. DISCUSSION: Key objective of this trial is to assess changes in nutrient pattern in blood and urine over time in critically ill patients with/without ICU-AW by using quantitative nutrient analysis techniques. Peer-reviewed published NAChO data will allow for a better understanding of metabolic changes in critically ill patients on standard liquid enteral nutrition and will likely open up new avenues for future therapeutic and nutritional interventions.


Asunto(s)
Enfermedad Crítica/terapia , Nutrición Enteral/métodos , Nutrientes/sangre , Adulto , Composición Corporal/fisiología , Lesiones Encefálicas/dietoterapia , Femenino , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Masculino , Espectrometría de Masas/instrumentación , Músculos/diagnóstico por imagen , Músculos/patología , Músculos/fisiología , Nutrientes/uso terapéutico , Nutrientes/orina , Estudios Prospectivos , Calidad de Vida , Sepsis/dietoterapia
2.
EMBO J ; 37(23)2018 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-30420557

RESUMEN

A set of glutamylases and deglutamylases controls levels of tubulin polyglutamylation, a prominent post-translational modification of neuronal microtubules. Defective tubulin polyglutamylation was first linked to neurodegeneration in the Purkinje cell degeneration (pcd) mouse, which lacks deglutamylase CCP1, displays massive cerebellar atrophy, and accumulates abnormally glutamylated tubulin in degenerating neurons. We found biallelic rare and damaging variants in the gene encoding CCP1 in 13 individuals with infantile-onset neurodegeneration and confirmed the absence of functional CCP1 along with dysregulated tubulin polyglutamylation. The human disease mainly affected the cerebellum, spinal motor neurons, and peripheral nerves. We also demonstrate previously unrecognized peripheral nerve and spinal motor neuron degeneration in pcd mice, which thus recapitulated key features of the human disease. Our findings link human neurodegeneration to tubulin polyglutamylation, entailing this post-translational modification as a potential target for drug development for neurodegenerative disorders.


Asunto(s)
Carboxipeptidasas/deficiencia , Cerebelo/enzimología , Neuronas Motoras/enzimología , Nervios Periféricos/enzimología , Células de Purkinje/enzimología , Columna Vertebral/enzimología , Degeneraciones Espinocerebelosas/enzimología , Cerebelo/patología , Femenino , Proteínas de Unión al GTP , Humanos , Masculino , Neuronas Motoras/patología , Péptidos/genética , Péptidos/metabolismo , Nervios Periféricos/patología , Procesamiento Proteico-Postraduccional , Células de Purkinje/patología , D-Ala-D-Ala Carboxipeptidasa de Tipo Serina , Columna Vertebral/patología , Degeneraciones Espinocerebelosas/genética , Degeneraciones Espinocerebelosas/patología
3.
Otol Neurotol ; 37(1): 89-98, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26649610

RESUMEN

HYPOTHESIS: A multielectrode probe in combination with an optimized stimulation protocol could provide sufficient sensitivity and specificity to act as an effective safety mechanism for preservation of the facial nerve in case of an unsafe drill distance during image-guided cochlear implantation. BACKGROUND: A minimally invasive cochlear implantation is enabled by image-guided and robotic-assisted drilling of an access tunnel to the middle ear cavity. The approach requires the drill to pass at distances below 1  mm from the facial nerve and thus safety mechanisms for protecting this critical structure are required. Neuromonitoring is currently used to determine facial nerve proximity in mastoidectomy but lacks sensitivity and specificity necessaries to effectively distinguish the close distance ranges experienced in the minimally invasive approach, possibly because of current shunting of uninsulated stimulating drilling tools in the drill tunnel and because of nonoptimized stimulation parameters. To this end, we propose an advanced neuromonitoring approach using varying levels of stimulation parameters together with an integrated bipolar and monopolar stimulating probe. MATERIALS AND METHODS: An in vivo study (sheep model) was conducted in which measurements at specifically planned and navigated lateral distances from the facial nerve were performed to determine if specific sets of stimulation parameters in combination with the proposed neuromonitoring system could reliably detect an imminent collision with the facial nerve. For the accurate positioning of the neuromonitoring probe, a dedicated robotic system for image-guided cochlear implantation was used and drilling accuracy was corrected on postoperative microcomputed tomographic images. RESULTS: From 29 trajectories analyzed in five different subjects, a correlation between stimulus threshold and drill-to-facial nerve distance was found in trajectories colliding with the facial nerve (distance <0.1  mm). The shortest pulse duration that provided the highest linear correlation between stimulation intensity and drill-to-facial nerve distance was 250  µs. Only at low stimulus intensity values (≤0.3  mA) and with the bipolar configurations of the probe did the neuromonitoring system enable sufficient lateral specificity (>95%) at distances to the facial nerve below 0.5  mm. However, reduction in stimulus threshold to 0.3  mA or lower resulted in a decrease of facial nerve distance detection range below 0.1  mm (>95% sensitivity). Subsequent histopathology follow-up of three representative cases where the neuromonitoring system could reliably detect a collision with the facial nerve (distance <0.1  mm) revealed either mild or inexistent damage to the nerve fascicles. CONCLUSION: Our findings suggest that although no general correlation between facial nerve distance and stimulation threshold existed, possibly because of variances in patient-specific anatomy, correlations at very close distances to the facial nerve and high levels of specificity would enable a binary response warning system to be developed using the proposed probe at low stimulation currents.


Asunto(s)
Implantación Coclear/efectos adversos , Traumatismos del Nervio Craneal/patología , Traumatismos del Nervio Craneal/prevención & control , Nervio Facial/patología , Monitorización Neurofisiológica/métodos , Procedimientos Quirúrgicos Otológicos/métodos , Complicaciones Posoperatorias/prevención & control , Robótica , Cirugía Asistida por Computador/métodos , Animales , Estimulación Eléctrica , Electromiografía , Nervio Facial/anatomía & histología , Apófisis Mastoides/patología , Apófisis Mastoides/cirugía , Procedimientos Quirúrgicos Otológicos/efectos adversos , Ovinos , Cirugía Asistida por Computador/efectos adversos , Instrumentos Quirúrgicos
SELECCIÓN DE REFERENCIAS