Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Radiology ; 218(2): 497-502, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11161168

RESUMEN

PURPOSE: To measure the effect of biopsy device, probe size, mammographic lesion type, lesion size, and number of samples obtained per lesion on the ductal carcinoma in situ (DCIS) underestimation rate. MATERIALS AND METHODS: Nonpalpable breast lesions at 16 institutions received a histologic diagnosis of DCIS after 14-gauge automated large-core biopsy in 373 lesions and after 14- or 11-gauge directional vacuum-assisted biopsy in 953 lesions. The presence of histopathologic invasive carcinoma was noted at subsequent surgical biopsy. RESULTS: By performing the chi(2) test, independent significant DCIS underestimation rates by biopsy device were 20.4% (76 of 373) of lesions diagnosed at large-core biopsy and 11.2% (107 of 953) of lesions diagnosed at vacuum-assisted biopsy (P <.001); by lesion type, 24.3% (35 of 144) of masses and 12.5% (148 of 1,182) of microcalcifications (P <.001); and by number of specimens per lesion, 17.5% (88 of 502) with 10 or fewer specimens and 11.5% (92 of 799) with greater than 10 (P <.02). DCIS underestimations increased with lesion size. CONCLUSION: DCIS underestimations were 1.9 times more frequent with masses than with calcifications, 1.8 times more frequent with large-core biopsy than with vacuum-assisted biopsy, and 1.5 times more frequent with 10 or fewer specimens per lesion than with more than 10 specimens per lesion.


Asunto(s)
Biopsia/instrumentación , Neoplasias de la Mama/patología , Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Axila , Biopsia/métodos , Neoplasias de la Mama/epidemiología , Carcinoma Intraductal no Infiltrante/epidemiología , Carcinoma Intraductal no Infiltrante/secundario , Femenino , Humanos , Metástasis Linfática , Persona de Mediana Edad , Manejo de Especímenes/instrumentación
2.
Radiology ; 204(2): 485-8, 1997 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9240540

RESUMEN

PURPOSE: To compare histologic findings of atypical ductal hyperplasia (ADH) at 14-gauge, directional, vacuum-assisted breast biopsy (hereafter, vacuum-assisted biopsy) and at 14-gauge, automated, large-core breast biopsy (hereafter, large-core biopsy) with findings at histologic examination after surgical biopsy. MATERIALS AND METHODS: Nonpalpable breast lesions were diagnosed as ADH at histologic examination after vacuum-assisted biopsy in 88 lesions in seven institutions and after large-core biopsy in 55 previously reported lesions. Histologic findings at subsequent surgical biopsy were compared for the presence of carcinoma. RESULTS: On the basis of histologic findings of carcinoma at surgical biopsy, the diagnosis of ADH was not correct in 26 (48%) of 54 lesions sampled at large-core biopsy and in 13 (18%) of 74 lesions sampled at vacuum-assisted biopsy (Fisher exact test, P < .0004). More tissue specimens were obtained at vacuum-assisted biopsy (mean, 15.8 specimens) than at large-core biopsy (mean, 9.7 specimens). Individual specimens were twice as large at vacuum-assisted biopsy (mean, 34 mg) as at large-core biopsy (mean, 17 mg) (previously reported). CONCLUSION: ADH was diagnosed 2.7 times more reliably at vacuum-assisted biopsy than at large-core biopsy (with no increase in complications) with most of the improvement as a result of acquisition of more than 10 specimens per lesion, but carcinoma was sufficiently underestimated with both methods to necessitate surgical biopsy.


Asunto(s)
Biopsia con Aguja/métodos , Enfermedades de la Mama/patología , Neoplasias de la Mama/patología , Mama/patología , Biopsia con Aguja/instrumentación , Carcinoma in Situ/patología , Carcinoma Ductal de Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Hiperplasia , Persona de Mediana Edad , Estudios Retrospectivos , Técnicas Estereotáxicas , Vacio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA