Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Thorac Cardiovasc Surg ; 136(1): 73-81, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18603056

RESUMEN

OBJECTIVE: Complexity of mitral valve repair for myxomatous disease has led to low adoption. We report initial experience with a new ring designed specifically for myxomatous disease, the Myxo-ETlogix (Edwards Lifesciences LLC, Irvine, Calif). METHODS: From March 15, 2006, through November 19, 2007, 129 patients underwent mitral valve surgery for pure myxomatous disease, and 124 valves (96.1%) were repaired. The Myxo-ETlogix ring was used in 100 cases and the Physio ring (Edwards) in 24. The Myxo-ETlogix design includes a 3-dimensional shape to reduce systolic anterior motion and a larger orifice to accommodate elongated leaflets and decrease need for sliding plasty. Direct mitral valve measurements were made. Sizing was based on A2 height, and choice of ring type was based on unresected leaflet heights. RESULTS: There was no operative mortality or lasting perioperative morbidity. The Myxo-ETlogix group had taller A2, P1, P2, and P3 leaflet segments than the Physio group (P < or = .003). Only 1 sliding plasty was performed for asymmetry in the Myxo-ETlogix group. Predischarge and follow-up echocardiograms (n = 338 in 124 patients) disclosed transient nonobstructive chordal systolic anterior motion in 3 echocardiograms in 3 patients. No patients had 2+ or greater mitral regurgitation. At discharge, 5.7% had 1+ mitral regurgitation; this proportion was 17.3% at last follow-up (mean 6.1 +/- 4.4 months). CONCLUSION: In initial experience with the Myxo-ETlogix ring, nonobstructive systolic anterior motion has been rare and obstructive systolic anterior motion not observed. Ongoing prospective echocardiographic and clinical studies will elucidate the role of this etiology-specific ring.


Asunto(s)
Prótesis Valvulares Cardíacas , Prolapso de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Diseño de Prótesis , Ajuste de Prótesis , Resultado del Tratamiento
2.
Cardiovasc Pathol ; 10(4): 179-88, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11600335

RESUMEN

BACKGROUND: Bioprosthetic heart valve use is limited by progressive degeneration. Early degenerative changes are often occult, making assessment of tissue integrity difficult. Ultrasound tissue characterization may detect alterations in tissue structure and allow early detection of leaflet degeneration. METHODS: Using a modified echocardiographic unit (Acuson), radiofrequency (RF) integrated backscatter amplitude (IBA) (integral/RF/dt) was measured in 38 leaflets from nine explanted and six control porcine valves. Regions of interest in each leaflet were studied using four ultrasound frequencies. Radiographic gray scale mean and leaflet thickness were measured at each region of interest. Percent collagen and mineral were calculated for each region of interest using color-image processing of histologic sections and compared to IBA. RESULTS: IBA values for control vs. explanted leaflets were (mean value+/-standard deviation): 8.2+/-4.69 dB vs. -4.7+/-4.64 dB at 7.0 MHz; -5.8+/-4.34 dB vs. -3.1+/-5.34 dB at 5.0 MHz; -3.8+/-3.38 dB vs. -2.1+/-3.18 dB at 3.5 MHz; and -9.0+/-4.58 dB vs. -7.1+/-4.25 dB at 2.5 MHz. Collagen content was 27.7+/-8.50% vs. 33.2+/-10.90%, mineral content was 0.1+/-0.10% vs. 2.1+/-4.30%, and radiographic gray scale mean was 150.6+/-1.96 vs. 145.3+/-5.14 for control vs. explanted leaflets, respectively. For control and explanted leaflets IBA, collagen content, mineral content, and radiographic gray scale mean were different (control vs. explanted P<0.05). Leaflet thickness was also noted to be different between the two groups. IBA was different among explanted leaflets with low, medium, and high mineral content. CONCLUSION: IBA was found to be a useful technique to differentiate normal from explanted porcine prosthetic valves in vitro. This method may be useful in the serial assessment of bioprosthetic leaflet degenerative properties in vivo.


Asunto(s)
Bioprótesis , Ecocardiografía/métodos , Prótesis Valvulares Cardíacas , Adulto , Anciano , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Calcinosis , Calcio/análisis , Colágeno/análisis , Ecocardiografía/instrumentación , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Válvula Mitral/cirugía , Ondas de Radio , Porcinos , Factores de Tiempo , Ultrasonografía
3.
Circulation ; 92(4): 790-5, 1995 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-7641358

RESUMEN

BACKGROUND: Although serotonin has been postulated as an etiologic agent in the development of carcinoid heart disease, no direct evidence for different ambient serotonin levels in cardiac and noncardiac patients has been reported to date. METHODS AND RESULTS: The present study reviews our experience with 604 patients in the Duke Carcinoid Database. Nineteen patients with proven carcinoid heart disease (by cardiac catheterization and/or echocardiogram) were compared with the remaining 585 noncardiac patients in the database with regard to circulating serotonin and its principal metabolite, 5-hydroxyindole acetic acid (5-HIAA). No significant demographic differences existed between the cardiac and noncardiac groups; however, typical carcinoid syndrome symptoms (ie, flushing and diarrhea) were almost threefold more common in the cardiac group (P < .001). Compared with the noncardiac group, heart disease patients demonstrated strikingly higher (P < .0001) mean serum serotonin (9750 versus 4350 pmol/mL), plasma serotonin (1130 versus 426 pmol/mL), platelet serotonin (6240 versus 2700 pmol/mg protein), and urine 5-HIAA (219 versus 55.3 mg/24 h) levels. The spectrum of heart disease among the 19 patients showed a strong right-sided valvular predominance, with tricuspid regurgitation being the most common valvular dysfunction (92% by cardiac catheterization; 100% by echocardiogram). CONCLUSIONS: These data suggest that serotonin plays a major role in the pathogenesis of the cardiac plaque formation observed in carcinoid patients.


Asunto(s)
Cardiopatía Carcinoide/sangre , Cardiopatía Carcinoide/complicaciones , Cateterismo Cardíaco , Ecocardiografía , Enfermedades de las Válvulas Cardíacas/etiología , Serotonina/sangre , Cardiopatía Carcinoide/diagnóstico por imagen , Enfermedad Coronaria/complicaciones , Femenino , Insuficiencia Cardíaca/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico , Humanos , Masculino , Estudios Prospectivos , Análisis de Supervivencia
4.
Am J Cardiol ; 75(7): 485-8, 1995 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-7863994

RESUMEN

The cardiac valvular surgical experience of patients in the Duke Carcinoid Database was reviewed to assess operative outcome. Of the 604 patients in the database, 19 patients with carcinoid heart disease were identified by cardiac catheterization or echocardiography, or both. Eight of these underwent tricuspid valve replacement surgery with bioprostheses (2 also had open pulmonic valvuloplasty). Compared with patients medically managed, surgically treated patients were similar with the exception that they had higher right atrial mean (17 +/- 6 vs 9 +/- 4 mm Hg, p = 0.03) and v-wave (27 +/- 6 vs 17 +/- 7 mm Hg, p = 0.04) pressures. Of the 8 surgical patients, 5 (63%) died within 30 days. Causes of death included tricuspid valve thrombosis, cerebral vascular accident, coagulopathy, renal failure, and intractable right heart failure. High comorbidity was present in all 8 patients. There was a weak trend (p = 0.17) toward lower Charlson comorbidity indexes in survivors (6.7 +/- 0.6) compared with nonsurvivors (7.6 +/- 0.9). Age was significantly lower (p = 0.036) in survivors (46 +/- 13 years) compared with nonsurvivors (69 +/- 4 years). Extended follow-up revealed 2 patients who survived beyond a decade. Review of 47 carcinoid valve replacement cases (Duke Carcinoid Database and 39 published cases) revealed a 30-day mortality of 56% for patients > 60 years of age, and 0% for those < or = 60 years of age (p < 0.0001). Although valve replacement surgery can afford prolonged palliation from carcinoid heart disease, it is associated with a significant mortality risk. Careful preoperative risk stratification by age and comorbidity may provide a means for optimal selection of surgical candidates.


Asunto(s)
Bioprótesis , Cardiopatía Carcinoide/cirugía , Prótesis Valvulares Cardíacas , Adulto , Factores de Edad , Anciano , Cardiopatía Carcinoide/mortalidad , Cardiopatía Carcinoide/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA