Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Acta Biomater ; 151: 501-511, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35933104

RESUMEN

The osteogenic capability of mesoporous bioactive nanoparticles (MBNPs) in the SiO2CaO system has been assessed in vivo using an osteoporotic rabbit model. MBNPs have been prepared using a double template method, resulting in spherical nanoparticles with a porous core-shell structure that has a high surface area and the ability to incorporate the anti-osteoporotic drug ipriflavone. In vitro expression of the pro-inflammatory genes NF-κB1, IL-6, TNF-α, P38 and NOS2 in RAW-264.7 macrophages, indicates that these nanoparticles do not show adverse inflammatory effects. An injectable system has been prepared by suspending MBNPs in a hyaluronic acid-based hydrogel, which has been injected intraosseously into cavitary bone defects in osteoporotic rabbits. The histological analyses evidenced that MBNPs promote bone regeneration with a moderate inflammatory response. The incorporation of ipriflavone into these nanoparticles resulted in a higher presence of osteoblasts and enhanced angiogenesis at the defect site, but without showing significant differences in terms of new bone formation. STATEMENT OF SIGNIFICANCE: Mesoporous bioactive glass nanoparticles have emerged as one of the most interesting materials in the field of bone regeneration therapies. For the first time, injectable mesoporous bioactive nanoparticles have been tested in vivo using an osteoporotic animal model. Our findings evidence that MBG nanoparticles can be loaded with an antiosteoporotic drug, ipriflavone, and incorporated in hyaluronic acid to make up an injectable hydrogel. The incorporation of MBG nanoparticles promotes bone regeneration even under osteoporotic conditions, whereas the presence of IP enhances angiogenesis as well as the presence of osteoblast cells lining in the newly formed bone. The injectable device presented in this work opens new possibilities for the intraosseous treatment of osteoporotic bone using minimally invasive surgery.


Asunto(s)
Nanopartículas , Osteoporosis , Animales , Regeneración Ósea , Huesos , Vidrio/química , Ácido Hialurónico/farmacología , Hidrogeles/farmacología , Interleucina-6 , Nanopartículas/química , Nanopartículas/uso terapéutico , Osteogénesis , Osteoporosis/tratamiento farmacológico , Porosidad , Conejos , Andamios del Tejido/química , Factor de Necrosis Tumoral alfa/farmacología
2.
J Pediatr Urol ; 17(5): 753-755, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34736728

RESUMEN

INTRODUCTION/BACKGROUND: Reconstructive and ablative urologic techniques require special technical mastery, especially the intracorporeal suturing. OBJECTIVE: To report the subjective evaluation of a versatile ex-vivo model aimed to practice laparoscopic ureteric reconstructive techniques (LURT) on box-trainer. STUDY DESIGN: The model is a continuous portion of porcine urinary bladder ("dilated pelvis"), the vesico-ureteral joint ("stenosis") and healthy ureter. All 127 participants (n = 119 urologists and n = 8 paediatric surgeons) performed on the model laparoscopic Anderson-Hynes dismembered pyeloplasty, and then, in the animal model, different LURT procedures (ureteroneocystostomy, ureteric reimplantation and/or dismembered pyeloplasty). The model was subjectively evaluated (face and content validity), through a 12 items questionnaire, based on a Likert scale (1-5 points) and a global question (1-10 points). RESULTS: The total mean rating for 11/12 items was very high (>4points). Only one was rated under 3 points. The overall total mean rating from 1 to 10 points was very high (9.19 ± 0.82 points). In 10/12 items, expert's feedback (content validity) prevailed over non-experts (face validity). DISCUSSION/CONCLUSION: The model was highly accepted for the practice of LURT techniques. Additionally, it is cost-effective, easy to assemble, ethically considerate, and realistic.


Asunto(s)
Laparoscopía , Uréter , Obstrucción Ureteral , Animales , Humanos , Pelvis Renal , Porcinos , Uréter/cirugía , Obstrucción Ureteral/cirugía , Procedimientos Quirúrgicos Urológicos
3.
Mol Hum Reprod ; 26(10): 748-759, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32647896

RESUMEN

This work was designed to determine temperature conditions within the reproductive tract of the female pig and study their impact on ARTs. Temperatures were recorded using a laparo-endoscopic single-site surgery assisted approach and a miniaturized probe. Sows and gilts were used to address natural cycle and ovarian stimulation treatments, respectively. According to in vivo values, IVF was performed at three temperature conditions (37.0°C, 38.5°C and 39.5°C) and presumptive zygotes were cultured in these conditions for 20 h, while further embryo culture (EC) (21-168 h post-insemination) was maintained at 38.5°C. After 20 h, different fertility parameters were assessed. During EC, cleavage and blastocyst stages were evaluated. Sperm membrane fluidity at the experimental temperatures was studied by using differential scanning calorimetry and fluorescence recovery after photobleaching techniques. An increasing temperature gradient of 1.5°C was found between the oviduct and uterus of sows (P < 0.05) and when this gradient was transferred to pig in vitro culture, the number of poly-nuclear zygotes after IVF was reduced and the percentage of blastocysts was increased. Moreover, the temperature transition phase for the boar sperm membrane (37.0°C) coincided with the temperature registered in the sow oviduct, and sperm membranes were more fluid at 37.0°C compared with those of sperm incubated at higher temperatures (38.5°C and 39.5°C). These data suggest that there may be an impact of physiological temperature gradients on human embryo development.


Asunto(s)
Técnicas de Cultivo de Embriones/métodos , Oviductos/fisiología , Temperatura , Útero/fisiología , Animales , Biomimética , Temperatura Corporal/fisiología , Células Cultivadas , Técnicas de Cultivo de Embriones/veterinaria , Embrión de Mamíferos , Desarrollo Embrionario/fisiología , Femenino , Fertilización In Vitro/métodos , Fertilización In Vitro/veterinaria , Porcinos
4.
Acta Biomater ; 101: 544-553, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31678741

RESUMEN

Silicon-substituted hydroxyapatite (SiHA) macroporous scaffolds have been prepared by robocasting. In order to optimize their bone regeneration properties, we have manufactured these scaffolds presenting different microstructures: nanocrystalline and crystalline. Moreover, their surfaces have been decorated with vascular endothelial growth factor (VEGF) to evaluate the potential coupling between vascularization and bone regeneration. In vitro cell culture tests evidence that nanocrystalline SiHA hinders pre-osteblast proliferation, whereas the presence of VEGF enhances the biological functions of both endothelial cells and pre-osteoblasts. The bone regeneration capability has been evaluated using an osteoporotic sheep model. In vivo observations strongly correlate with in vitro cell culture tests. Those scaffolds made of nanocrystalline SiHA were colonized by fibrous tissue, promoted inflammatory response and fostered osteoclast recruitment. These observations discard nanocystalline SiHA as a suitable material for bone regeneration purposes. On the contrary, those scaffolds made of crystalline SiHA and decorated with VEGF exhibited bone regeneration properties, with high ossification degree, thicker trabeculae and higher presence of osteoblasts and blood vessels. Considering these results, macroporous scaffolds made of SiHA and decorated with VEGF are suitable bone grafts for regeneration purposes, even in adverse pathological scenarios such as osteoporosis. STATEMENT OF SIGNIFICANCE: For the first time, the in vivo behavior of scaffolds made of silicon substituted hydroxyapatites (SiHA) has been evaluated under osteoporosis conditions. In order to optimize the bone regeneration properties of these bioceramics, 3D macroporous scaffolds have been manufactured by robocasting and implanted in osteoporotic sheep. Our experimental design shed light on the important issue of the biological response of nano-sized bioceramics vs highly crystalline bioceramics, as well as on the importance of coupling vascularization and bone growth processes by decorating SiHA scaffolds with vascular endothelial growth factor.


Asunto(s)
Regeneración Ósea/efectos de los fármacos , Durapatita/farmacología , Osteoporosis/patología , Silicio/farmacología , Andamios del Tejido/química , Factor A de Crecimiento Endotelial Vascular/farmacología , Adsorción , Animales , Diferenciación Celular/efectos de los fármacos , Línea Celular , Proliferación Celular/efectos de los fármacos , Forma de la Célula/efectos de los fármacos , Células Endoteliales/efectos de los fármacos , Células Endoteliales/metabolismo , Células Endoteliales/ultraestructura , Femenino , Ratones , Nanopartículas/química , Nanopartículas/ultraestructura , Osteoblastos/citología , Osteoblastos/efectos de los fármacos , Osteoporosis/diagnóstico por imagen , Porosidad , Ovinos , Porcinos , Tomografía Computarizada por Rayos X
5.
Actas Urol Esp (Engl Ed) ; 43(7): 348-354, 2019 Sep.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31128874

RESUMEN

OBJECTIVE: The aim of this study is to prove the effectiveness of a low cost, artificial model for training of a laparoscopic urethrovesical anastomosis. MATERIALS AND METHODS: This study included urologists who attended specialised courses on laparoscopic radical prostatectomy (LRP) held during the period 2015 to 2017. They were divided into 2 groups according to their previous experience in laparoscopic surgery. The tasks performed on the artificial simulator were prostate resection, "task 1", and urethrovesical anastomosis, "task 2". Once these exercises were completed, the study participants filled in an anonymous questionnaire regarding their demographic data and experience level in laparoscopic surgery (LS). In addition, they gave their opinions about the didactic capacity of the artificial organ and evaluated its usefulness as a tool for LRP training. To demonstrate face and content validity, the participants judged the texture, consistency, morphology and evaluated its similarity to the real organ. The assessment was made with a five-point Likert scale. RESULTS: The students were divided into 2groups: 10 experts (Group E) and 12 novices (Group N). The only significant difference between the scores of novices and experts was regarding the inclusion of this tool in the training programs (Group E=5 points versus group N=4.4±0.59, P=.024). The experts' group rated all the items with higher scores than the novices' one. Regarding the general assessment of the simulation model, the novice participants gave an average score of 8.00±0.91 points out of 10, while the experts' group granted higher scores of 9.4±0,51. CONCLUSION: This artificial model has shown to have an elevated face, content and construct validity, as well being an optimal didactic tool for training in the techniques of prostate resection and laparoscopic urethrovesical anastomosis.


Asunto(s)
Laparoscopía/educación , Modelos Anatómicos , Prostatectomía/educación , Prostatectomía/métodos , Entrenamiento Simulado , Uretra/cirugía , Vejiga Urinaria/cirugía , Anastomosis Quirúrgica , Humanos , Masculino
6.
Acta Biomater ; 83: 456-466, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30445158

RESUMEN

The osteogenic and angiogenic responses to metal macroporous scaffolds coated with silicon substituted hydroxyapatite (SiHA) and decorated with vascular endothelial growth factor (VEGF) have been evaluated in vitro and in vivo. Ti6Al4V-ELI scaffolds were prepared by electron beam melting and subsequently coated with Ca10(PO4)5.6(SiO4)0.4(OH)1.6 following a dip coating method. In vitro studies demonstrated that SiHA stimulates the proliferation of MC3T3-E1 pre-osteoblastic cells, whereas the adsorption of VEGF stimulates the proliferation of EC2 mature endothelial cells. In vivo studies were carried out in an osteoporotic sheep model, evidencing that only the simultaneous presence of both components led to a significant increase of new tissue formation in osteoporotic bone. STATEMENT OF SIGNIFICANCE: Reconstruction of bones after severe trauma or tumors extirpation is one of the most challenging tasks in the field of orthopedic surgery. This scenario is even more complicated in the case of osteoporotic patients, since their bone regeneration capability is decreased. In this work we present a porous implant that promotes bone regeneration even in osteoporotic bone. By coating the implant with osteogenic bioceramics such as silicon substituted hydroxyapatite and subsequent adsorption of vascular endothelial growth factor, these implants stimulate the bone ingrowth when they are implanted in osteoporotic sheep.


Asunto(s)
Regeneración Ósea/efectos de los fármacos , Durapatita , Osteoporosis , Silicio , Titanio , Factor A de Crecimiento Endotelial Vascular , Aleaciones , Animales , Línea Celular , Proliferación Celular/efectos de los fármacos , Durapatita/química , Durapatita/farmacología , Células Endoteliales/metabolismo , Células Endoteliales/patología , Femenino , Ratones , Osteoblastos/metabolismo , Osteoblastos/patología , Osteoporosis/tratamiento farmacológico , Osteoporosis/metabolismo , Osteoporosis/patología , Ovinos , Silicio/química , Silicio/farmacología , Porcinos , Titanio/química , Titanio/farmacología , Factor A de Crecimiento Endotelial Vascular/química , Factor A de Crecimiento Endotelial Vascular/farmacología
7.
Acta Biomater ; 85: 60-74, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30500445

RESUMEN

Surgical meshes are frequently used for the treatment of abdominal hernias, pelvic organ prolapse, and stress urinary incontinence. Though these meshes are designed for tissue reinforcement, many complications have been reported. Both differentiated cell- and mesenchymal stem cell-based therapies have become attractive tools to improve their biocompatibility and tissue integration, minimizing adverse inflammatory reactions. However, current studies are highly heterogeneous, making it difficult to establish comparisons between cell types or cell coating methodologies. Moreover, only a few studies have been performed in clinically relevant animal models, leading to contradictory results. Finally, a thorough understanding of the biological mechanisms of mesenchymal stem cells in the context of foreign body reaction is lacking. This review aims to summarize in vitro and in vivo studies involving the use of differentiated and mesenchymal stem cells in combination with surgical meshes. According to preclinical and clinical studies and considering the therapeutic potential of mesenchymal stem cells, it is expected that these cells will become valuable tools in the treatment of pathologies requiring tissue reinforcement. STATEMENT OF SIGNIFICANCE: The implantation of surgical meshes is the standard procedure to reinforce tissue defects such as hernias. However, an adverse inflammatory response secondary to this implantation is frequently observed, leading to a strong discomfort and chronic pain in the patients. In many cases, an additional surgical intervention is needed to remove the mesh. Both differentiated cell- and stem cell-based therapies have become attractive tools to improve biocompatibility and tissue integration, minimizing adverse inflammatory reactions. However, current studies are incredibly heterogeneous and it is difficult to establish a comparison between cell types or cell coating methodologies. This review aims to summarize in vitro and in vivo studies where differentiated and stem cells have been combined with surgical meshes.


Asunto(s)
Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Mallas Quirúrgicas , Animales , Reacción a Cuerpo Extraño/patología , Humanos , Inflamación/patología , Trasplante de Células Madre Mesenquimatosas/efectos adversos , Prótesis e Implantes
8.
Mol Hum Reprod ; 24(5): 260-270, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29490063

RESUMEN

STUDY QUESTION: Is O2 tension in the pig oviduct and uterus affected by the estrous cycle stage and the animal's age, and can the outcome of in vitro embryo development be improved by mimicking these physiological values? SUMMARY ANSWER: O2 tension within the pig reproductive organs is affected by the animal's age, and values close to those measured in vivo have a positive impact on embryo development and quality when used during IVF and embryo culture (EC). WHAT IS KNOWN ALREADY: To obtain a healthy embryo in vitro, it is necessary to adopt a culture microenvironment that approximates physiological conditions. Despite advances in surgical procedures and sensitive probes that allow accurate assessment of in vivo O2 tension, few such studies have been conducted recently in mammals. In addition, no reference values of physiological O2 tension in the reproductive tract exist for large animal models such as pig, and the effect of O2 tension on ART outcomes is unknown. STUDY DESIGN, SIZE, DURATION: This study was conducted in pigs. We measured oviductal and uterine O2 tension (n = 29 and 13, respectively) and then examined how the use of the physiological values in pig IVF and EC affected pig ART output (n = 1447 oocytes). PARTICIPANTS/MATERIALS, SETTING, METHODS: The oviductal and uterine O2 tension at the different stages of the estrous cycle was monitored using a laparo-endoscopic single-site surgery (LESS) assisted approach along with a flexible and thin miniaturized luminescent probe. Two groups of pigs, Large-white × Landrace breed, were used: for the first group, 16 pre-pubertal gilts (5 months old and 95 kg) were induced to ovulate with equine chorionic gonadotropin (eCG) and human chorionic gonadotropin (hCG); in the second group 13 mature sows (24-48 months and 185 kg) were used. IVF and EC were performed at two different O2 tensions: Atmospheric O2 (20%) and the mean in vivo value measured (7%). At 18-20 h post-insemination (hpi), a small sample of presumptive zygotes were fixed, stained and examined under epifluorescence microscopy to assess the fertilization rates. At 48 hpi, cleavage was evaluated under the stereomicroscope. Finally, at 180 hpi, development to the blastocyst stage was quantified, blastocyst morphology was assessed, and embryos were fixed and stained to count the mean cell number per blastocyst. MAIN RESULTS AND THE ROLE OF CHANCE: The mean O2 content within the pig oviduct and uterus was always lower than in ambient air. The average O2 percentage was higher in gilts (10.0%) than in sows (7.6%) (P < 0.0001). The cleavage rate of porcine in vitro fertilized embryos maintained under 7% O2 during IVF and EC was significantly higher (60.0 ± 2.3) compared with those cultured under 20% O2 (32.0 ± 2.2) (P < 0.05). An increase in the number of cells in embryos cultured under the low O2 concentration (88.9 ± 5.9) was observed compared to those cultured under 20% O2 (59.0 ± 5.0) (P < 0.05). LARGE SCALE DATA: None. LIMITATIONS, REASONS FOR CAUTION: Although minimally invasive surgery was used the effect of anesthesia and manipulations on O2 tension within the organs are unknown. WIDER IMPLICATIONS OF THE FINDINGS: Using physiological oxygen concentrations in IVF/EC could improve ART outcomes. STUDY FUNDING AND COMPETING INTEREST(S): This study was funded by Spanish Ministry of Economy and Competitiveness (MINECO) and European Regional Development Fund (FEDER). Grants AGL2012-40180-C03-01 and AGL2015-66341-R. The authors declare no conflict of interest.


Asunto(s)
Blastocisto/fisiología , Desarrollo Embrionario/fisiología , Oviductos/fisiología , Oxígeno/fisiología , Técnicas Reproductivas Asistidas/veterinaria , Útero/fisiología , Animales , Femenino , Embarazo , Porcinos
9.
Arch Esp Urol ; 69(8): 583-594, 2016 Oct.
Artículo en Español | MEDLINE | ID: mdl-27725334

RESUMEN

The management of ureteral obstruction of malignant origin or complicated benign obstruction continues to be a challenge for the urological community. In this sense, the use of metallic stents could be considered a useful alternative to the conventional drainage techniques, because it accomplishes the resolution of obstruction in a single procedure, without external diversions and without the adverse effects of current diversions. Another important advantage they offer is that they do not need replacement as frequently as double J catheters or nephrostomy tubes require. From their first applications in the upper urinary tract until now the design of metallic stents has experienced a notable evolution. The main obstacle at the beginning was the use of stents intended for other organic territories, which caused a high rate of failures, since they did not take into consideration in their designs the hostile environment represented by urine for this type of devices, neither the existence of ureteral peristaltism. Thanks to subsequent metallic designs (Memokath, Uventa, Allium Medical URS-stent, Resonance), the current generation of ureteral metallic stents has improved the success rate in comparison to classical designs, accommodating to ureteral dynamics and improving the coating and alloys. Despite these advances, today, their application is limited to very selected patients due to the onset of undesirable effects still associated with theses stents, such as obstructive urothelial hyperplasia, encrustation or migration. The precise knowledge of the physiopathological mechanisms responsible for the cited adverse effects, together with the application of Bioengineering enabling the development of drug eluting metallic stents, biocoated stents, or new biodegradable metallic materials that mitigate or diminish their effects, may be the key to allow the development of the ideal metallic stent.


Asunto(s)
Stents , Uréter/cirugía , Predicción , Humanos , Diseño de Prótesis , Stents/efectos adversos , Stents/tendencias
10.
Int J Oral Maxillofac Surg ; 45(7): 836-41, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26850940

RESUMEN

The traditional method of surgical training has followed the 'observe, practice, and teach' model, which is useful for open surgery, but is insufficient for minimally invasive surgery. This study presents the validation of a new simulator designed for TMJ arthroscopy training. A group of 10 senior maxillofacial surgeons performed an arthroscopy procedure using the simulator. They then completed a questionnaire analyzing the realism of the simulator, its utility, and the educational quality of the audiovisual software. The mean age of the 10 surgeons was 42.6 years, and they had performed a mean 151 arthroscopies. With regard to the realism of the simulator, 80% reported that it was of an appropriate size and design and 70% referred to the very realistic positions and relationships between the internal structures. Regarding its educational potential, 80% reported the simulator to be very useful for acquiring the basic skills and to acquire the sensation of depth during access to the TMJ. Finally, 90% reported the prototype to be very useful for TMJ arthroscopy training. These preliminary results showed a high degree of approval. The general opinion of the group of experts was that the experience was rewarding and inspiring, and that the prototype has the educational potential for the achievement of basic TMJ arthroscopy skills.


Asunto(s)
Artroscopía/educación , Artroscopía/instrumentación , Modelos Anatómicos , Articulación Temporomandibular/cirugía , Adulto , Artroscopía/métodos , Femenino , Humanos , Masculino , Encuestas y Cuestionarios
11.
Surg Endosc ; 30(10): 4489-98, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26895907

RESUMEN

BACKGROUND: The aim of this study was to develop an easy-to-induce and reproducible model of gastric submucosal tumor in swine to compare minilaparoscopy (ML) with single-incision (SI) intragastric surgery. METHODS: Twelve healthy female pigs (weight 30.94 ± 2.49 kg) underwent a transparietal injection of sterile alginate at the level of Z-line (n = 6) and at the pre-pyloric area (n = 6) creating a model of gastric submucosal pseudotumor. The operative procedures included intragastric resection with ML and SI approaches of cardiac and pre-pyloric lesions, with gastroscopic assistance. After resection, the gastric mucosal layer was closed using intracorporeal sutures. The operative time, complication rate and clinical evolution after 1 month were compared in the four groups that the pigs were arranged. RESULTS: The pseudotumors ranged in size from 3 to 6 cm in diameter. The access of the gastric cavity and resection of the experimental SMP and suturing of the mucosa were performed successfully in 12 animals using both approaches. Mean time to perform the exeresis of gastric cardia tumors was significantly higher in single-incision approach. No significant differences were observed in the surgical time during pyloric surgery. Minilaparoscopic approach reduced significantly the mucosa closure time in esophagogastric and pyloric pseudotumors. One month after, no alterations were shown in the abdominal cavity using exploratory laparotomy. CONCLUSIONS: The technical feasibility of performing safe and efficient intragastric approach of submucosal pseudotumors in swine model was verified in this study. Intragastric ML has advantages over SI, namely regarding the reduction in total surgical times and the fewer technical difficulties.


Asunto(s)
Mucosa Gástrica/cirugía , Neoplasias Gástricas/cirugía , Animales , Femenino , Gastrectomía/métodos , Gastroscopía/métodos , Laparoscopía/métodos , Modelos Animales , Tempo Operativo , Distribución Aleatoria , Suturas , Porcinos
12.
Actas Urol Esp ; 40(4): 237-44, 2016 May.
Artículo en Inglés, Español | MEDLINE | ID: mdl-26811021

RESUMEN

OBJECTIVE: To assess a training model focused on laparoscopic nephrectomy. MATERIAL AND METHODS: 16 residents participated in the study, who attended a training program with a theoretical session (1hour) and a dry (7hours) and a wet lab (13hours). During animal training, the first and last nephrectomies were assessed through the completion time and the global rating scale "Objective and Structured Assessment of Technical Skills" (OSATS). Before and after the course, they performed 3 tasks on the virtual reality simulator LAPMentor (1) eye-hand coordination; 2) hand-hand coordination; and 3) transference of objects), registering time and movement metrics. All participants completed a questionnaire related to the training components on a 5-point rating scale. RESULTS: The participants performed the last nephrectomy faster (P<.001) and with higher OSATS scores (P<.001). After the course, they completed the LAPMentor tasks faster (P<.05). The number of movements decreased in all tasks (1) P<.001, 2) P<.05, and 3) P<.05), and the path length in tasks 1 (P<.05) and 2 (P<.05). The movement speeds increased in tasks 2 (P<.001) and 3 (P<.001). With regards to the questionnaire, the usefulness of the animal training and the necessity of training on them prior to their laparoscopic clinical practice were the questions with the highest score (4.92±.28). CONCLUSIONS: The combination of physical simulation and animal training constitute an effective training model for improving basic and advanced skills for laparoscopic nephrectomy. The component preferred by the urology residents was the animal training.


Asunto(s)
Laparoscopía/educación , Nefrectomía/educación , Adulto , Competencia Clínica , Simulación por Computador , Femenino , Humanos , Masculino , Modelos Animales , Modelos Educacionales
13.
Actas Urol Esp ; 40(1): 55-63, 2016.
Artículo en Inglés, Español | MEDLINE | ID: mdl-26321191

RESUMEN

CONTEXT AND OBJECTIVE: The acquisition and improvement of surgical skills constitute a fundamental element in the training of any practitioner. At present, however, the assessment of these skills is a scarcely developed area of research. The aim of this study was to analyse the peculiarities of the various assessment systems and establish the minimum criteria that a skills and knowledge assessment system should meet as a method for assessing surgical skills in urological surgery. ACQUISITION OF EVIDENCE: Scientific literature review aimed at the various currently available assessment systems for skills and competencies (technical and nontechnical), with a special focus on the systematic reviews and prospective studies. SUMMARY OF THE EVIDENCE: After conducting the review, we found that the various assessment systems for surgical competence have, in our opinion, a number of shortcomings. There is a certain degree of subjectivity in the assessment of surgeons by the evaluators. The assessment of nontechnical competencies is not formally recorded. There is no description of a follow-up assessment or any basic parameters associated with healthcare quality. There is no registration of associated competencies associated with the various surgical techniques. There is also no ranking of these competencies and the specific peculiarities for their application. CONCLUSIONS: We believe that the development of a new assessment system for surgical competencies (technical and nontechnical) aimed at assessing urologists in the various surgical techniques is necessary. To this end, our team has worked on developing the Evaluation System for Surgical Competencies on Laparoscopy, which is based on the definition, ranking and assessment of competencies demonstrated by surgeons.


Asunto(s)
Competencia Clínica , Laparoscopía/normas , Procedimientos Quirúrgicos Urológicos/métodos , Procedimientos Quirúrgicos Urológicos/normas , Humanos
14.
Vet Rec Open ; 2(2): e000153, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26568831

RESUMEN

Laparoscopic ovariohysterectomy using single-portal access was performed in nine selected owned dogs admitted for elective ovariohysterectomy and the surgical technique and outcomes were detailed. A multiport device (SILS Port, Covidien, USA) was placed at the umbilical area through a single 3 cm incision. Three cannulae were introduced in the multiport device through the access channels and laparoscopic ovariohysterectomy was performed using a 5-mm sealing device, a 5-mm articulating grasper and a 5-mm 30° laparoscope. The mean total operative time was 52.66±15.20 minutes and the mean skin incision during surgery was 3.09±0.20 cm. Of the nine cases examined, in the one with an ovarian tumour, the technique was converted to multiport laparoscopy introducing an additional 5-mm trocar. No surgical complications were encountered and intraoperative blood loss was minimum in all animals. Clashing of the instruments and reduced triangulation were the main limitations of this technique. The combination of articulated and straight instruments facilitated triangulation towards the surgical field and dissection capability. One month after surgery a complete wound healing was observed in all animals. The present data showed that ovariohysterectomy performed with a single-port access is technically feasible in dogs. The unique abdominal incision minimises the abdominal trauma with good cosmetic results.

15.
Eur J Surg Oncol ; 40(6): 713-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24560464

RESUMEN

OBJECTIVE: To investigate the feasibility and safety of laparoscopy-assisted transvaginal resection of sigmoid cancer. METHODS: From 2009 to 2011 we performed 21 laparoscopy-assisted transvaginal resections of sigmoid cancers. RESULTS: The resected tumours were T1(6), T2(7) and T3(8). The median number of resected lymph nodes was 15. Median operative time was 150 min and no conversion to open technique was necessary. A total of eighteen patients tolerated a liquid diet 24 h after surgery. The average VAS pain score (0 = no pain, 10 = unbearable pain) was 1.8 after 24 h and 1.1 after 48 h. One patient experienced a postoperative ileus, two patients had vaginal spotting with serous flow and three patients suffered urinary tract infections. One patient developed a hernia at the umbilical trocar site that was operated on. None of the sexually active patients reported any differences in sexual activity pre-op and postop on a postoperative questionnaire. After a median of 25 (10-41) months of follow-up, all patients are alive and well, with no evidence of recurrent disease. CONCLUSION: Laparoscopy-assisted transvaginal resection of sigmoid cancer is feasible and safe in a selected group of patients.


Asunto(s)
Laparoscopía/métodos , Neoplasias del Colon Sigmoide/cirugía , Anciano , Estudios de Factibilidad , Femenino , Humanos , Escisión del Ganglio Linfático , Estadificación de Neoplasias , Tempo Operativo , Dimensión del Dolor , Complicaciones Posoperatorias/epidemiología , Neoplasias del Colon Sigmoide/patología , Resultado del Tratamiento , Vagina
16.
Surg Endosc ; 28(4): 1314-20, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24337915

RESUMEN

BACKGROUND: Adding to the ergonomic inconveniences already presented by traditional laparoscopy (LAP), laparoendoscopic single-site (LESS) surgery has been found to entail other more specific problems, including greater reduction in movement freedom, in-line vision with loss of triangulation, and greater proximity of instruments. The objective of this study was to evaluate surgeons' ergonomy during LESS surgery, through the study of muscular activity, wrist angle, and hand movements, and compare it with conventional laparoscopy. METHODS: The study group was composed by 14 experienced laparoscopic surgeons, all right-handed. Each one performed dissection tasks on a physical simulator through LAP and LESS approaches. For LAP, straight laparoscopic scissors and dissector were used, whilst for LESS articulating tip scissors and dissector were chosen. During both tasks, muscular activity of biceps brachii, triceps brachii, forearm flexors and extensors, and trapezius muscles was registered through surface electromyography. Simultaneously right-hand movements and wrist angles were obtained through a motion capture data glove (CyberGlove(®)), which allowed for the use of a modified RULA test applied to the recorded angles with subsequent establishment of risk levels for the wrist joint. RESULTS: Muscular activity for trapezius (LAP 6.94 ± 4.12 vs. LESS 11.32 ± 4.68; p ≤ 0.05) and forearm extensor muscles (LAP 9.2 ± 2.45 vs. LESS 37.07 ≤ 16.05; p ≤ 0.001) was significantly lower in conventional laparoscopy compared with LESS approach. No statistical significance was obtained between the different sensors, except in 3 of the 11 analyzed CyberGlove(®) sensors. The modified RULA test showed a score of 3 for laparoscopy (unacceptable), whereas for LESS a score of 2 was obtained (acceptable), with statistically significant differences between them (p ≤ 0.05). CONCLUSIONS: The LESS approach entails greater level of muscular activity in the trapezius and forearm extensor muscles, but we have found evidences of a better wrist position during LESS compared with traditional laparoscopy.


Asunto(s)
Disección/métodos , Electromiografía/métodos , Ergometría/métodos , Antebrazo/fisiología , Laparoscopía , Músculo Esquelético/fisiología , Médicos , Humanos , Persona de Mediana Edad , Movimiento (Física)
17.
Stem Cell Rev Rep ; 9(2): 184-9, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23397451

RESUMEN

Several clinical trials are currently evaluating the safety and efficacy of mesenchymal stem cells (MSCs) in different diseases. The MSCs are guided by inflammatory mediators and specific interactions with immune cells occur, especially between MSCs and the cells of the innate immune system. At the present many of these interactions remain to be determined. This review summarizes the current knowledge in relation to the susceptibility of MSCs to NK cell mediated lysis as well as the immunomodulatory activity of MSCs and its control over NK cell function. Here we hypothesize that the inflammatory context will regulate the outcome of NK-MSC interactions.


Asunto(s)
Inmunomodulación , Células Asesinas Naturales/inmunología , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/inmunología , Comunicación Celular/inmunología , Muerte Celular , Ensayos Clínicos como Asunto , Citocinas/inmunología , Humanos , Células Asesinas Naturales/citología , Células Madre Mesenquimatosas/citología
18.
Rev Esp Anestesiol Reanim ; 59(7): 363-9, 2012.
Artículo en Español | MEDLINE | ID: mdl-22766278

RESUMEN

OBJECTIVE: To compare the airway pressures obtained before the endotracheal tube with the intratracheal ones in the continuous flow ventilation mode, in thoracoscopic surgery for one lung ventilation, in a paediatric model in animals. MATERIAL AND METHODS: A simple prospective observational study was conducted. Ten Large White pigs weighing 4.6 ± 0.8 kg were used. The animals were ventilated in neonatal mode (continuous flow) with a Temel Supra ventilator. Using tracheotomy, we completely sealed the respiratory system in order to use tubes without special endotracheal cuffs, which would enable tracheal pressures to be registered without interfering with ventilation. Collapse of the right lung was performed by videothoracoscopy and was maintained for 120 min. The variables were measured at 10 time periods: start and 5 min with both lungs, after collapse at 5, 15, 30, 60, 90 and 120 min, and 5 and 15 min after lung re-expansion. We recorded the baseline, peak, plateau and positive end expiratory pressure in the mouth of the animal and intratracheal. RESULTS: The mean peak pressure in the mouth of the animal in one lung ventilation was 23.38 mmHg and tracheal ventilation was 21.24 mmHg, while the mean plateau pressure in the mouth of the animal in one lung ventilation it was 21.88 mmHg and tracheal was 21.39 mmHg, respectively, with significant differences in all of them (P<.05). We found statistically significant differences (P<.05) for peak and plateau pressure on comparing the record in the animal mouth with the tracheal record. The difference in absolute value was higher for the peak pressure record. CONCLUSIONS: The pressure parameters recorded in the animal mouth were acceptable for surgery, with a suitable respiratory and haemodynamic stability being maintained. We can state that the continuous flow mode according to the pressures study may be suitable for this type of surgery, and that the mouth of the animal (patient) record for the peak pressure does not reflect what really happens in the alveoli, but we can give a suitable clinical estimate for the plateau pressure.


Asunto(s)
Presión del Aire , Manometría/métodos , Modelos Animales , Pediatría/métodos , Pruebas de Función Respiratoria/métodos , Toracoscopía/métodos , Resistencia de las Vías Respiratorias , Animales , Humanos , Boca , Ventilación Unipulmonar , Estudios Prospectivos , Alveolos Pulmonares , Sus scrofa , Porcinos
19.
Vet Immunol Immunopathol ; 147(1-2): 104-12, 2012 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-22521281

RESUMEN

Mesenchymal stem cells have demonstrated their potentiality for therapeutic use in treating diseases or repairing damaged tissues. However, in some cases, the results of clinical trials have been disappointing or have not worked out as well as hoped. These disappointing results can be attributed to an inadequate or insufficient preclinical study. For medical and surgical purposes, the similarities between the anatomy of pig and human make this animal an attractive preclinical model. In this sense, for mesenchymal stem cell-based therapy, it is strongly necessary to have well characterized animal-derived mesenchymal stem cell lines to validate preclinical effectiveness of these cells. In this work, porcine mesenchymal stem cells (pMSCs) were isolated from bone marrow, adipose tissue and peripheral blood and compared in terms of differentiation potential, cell surface markers and gene expression. Our results demonstrated that the isolation and in vitro expansion protocols were feasible and effective. The data presented in this work are relevant because they provide an extensive phenotypic characterization; genetic study and differentiation behavior of the most commonly used stem cell lines for clinical practices. These pMSCs are widely available to scientists and could be a valuable tool to evaluate the safety and efficacy of adoptively transferred cells.


Asunto(s)
Células Madre Mesenquimatosas/citología , Adipogénesis , Animales , Diferenciación Celular , Separación Celular , Condrogénesis , Humanos , Modelos Animales , Osteogénesis , Fenotipo , Reacción en Cadena en Tiempo Real de la Polimerasa , Porcinos , Investigación Biomédica Traslacional
20.
Int J Comput Assist Radiol Surg ; 7(6): 881-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22492427

RESUMEN

PURPOSE: Surgical simulators are currently essential within any laparoscopic training program because they provide a low-stakes, reproducible and reliable environment to acquire basic skills. The purpose of this study is to determine the training learning curve based on different metrics corresponding to five tasks included in SINERGIA laparoscopic virtual reality simulator. METHODS: Thirty medical students without surgical experience participated in the study. Five tasks of SINERGIA were included: Coordination, Navigation, Navigation and touch, Accurate grasping and Coordinated pulling. Each participant was trained in SINERGIA. This training consisted of eight sessions (R1-R8) of the five mentioned tasks and was carried out in two consecutive days with four sessions per day. A statistical analysis was made, and the results of R1, R4 and R8 were pair-wise compared with Wilcoxon signed-rank test. Significance is considered at P value <0.005. RESULTS: In total, 84.38% of the metrics provided by SINERGIA and included in this study show significant differences when comparing R1 and R8. Metrics are mostly improved in the first session of training (75.00% when R1 and R4 are compared vs. 37.50% when R4 and R8 are compared). In tasks Coordination and Navigation and touch, all metrics are improved. On the other hand, Navigation just improves 60% of the analyzed metrics. Most learning curves show an improvement with better results in the fulfillment of the different tasks. CONCLUSIONS: Learning curves of metrics that assess the basic psychomotor laparoscopic skills acquired in SINERGIA virtual reality simulator show a faster learning rate during the first part of the training. Nevertheless, eight repetitions of the tasks are not enough to acquire all psychomotor skills that can be trained in SINERGIA. Therefore, and based on these results together with previous works, SINERGIA could be used as training tool with a properly designed training program.


Asunto(s)
Simulación por Computador , Educación de Pregrado en Medicina/métodos , Laparoscopía , Curva de Aprendizaje , Desempeño Psicomotor , Interfaz Usuario-Computador , Adulto , Competencia Clínica , Femenino , Humanos , Masculino , Análisis y Desempeño de Tareas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA