Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Med Phys ; 50(12): 7441-7461, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37830895

RESUMEN

BACKGROUND: The Tomosynthesis Mammography Imaging Screening Trial (TMIST), EA1151 conducted by the Eastern Cooperative Oncology Group (ECOG)/American College of Radiology Imaging Network (ACRIN) is a randomized clinical trial designed to assess the effectiveness for breast cancer screening of digital breast tomosynthesis (TM) compared to digital mammography (DM). Equipment from multiple vendors is being used in the study. PURPOSE: For the findings of the study to be valid and capture the true capacities of the two technology types, it is important that all equipment is operated within appropriate parameters with regard to image quality and dose. A harmonized QC program was established by a core physics team. Since there are over 120 trial sites, a centralized, automated QC program was chosen as the most practical design. This report presents results of the weekly QC testing program. A companion paper will review quality monitoring based on data from the headers of the patient images. METHODS: Study images are collected centrally after de-identification using the "TRIAD" application developed by ACR. The core physics team devised and implemented a minimal set of quality control (QC) tests to evaluate the tomosynthesis and 2D mammography systems. Weekly, monthly and annual testing is performed by the site mammography technologists with images submitted directly to the physics core. The weekly physics QC tests are described: SDNR of a low-contrast mass object, artifact spread, spatial resolution, tracking of technical factors, and in-slice noise power spectra. RESULTS: As of December 31, 2022 (5 years), 145 sites with 411 machines had submitted QC data. A total of 136 742 TMIST participant screening imaging studies had been performed. The 5th and 95th percentile mean glandular doses for a single tomosynthesis exposure to a 4.0 cm thick PMMA phantom ("standard breast phantom") were 1.24 and 1.68 mGy respectively. The largest sources of QC non-conformance were: operator error, not following the QC protocol exactly, unreported software updates and preventive maintenance activities that affected QC setpoints. Noise power spectra were measured, however, standardization of performance targets across machine types and software revisions was difficult. Nevertheless, for each machine type, test measurement results were very consistent when the protocol was followed. Deviations in test results were mostly related to software and hardware changes. CONCLUSION: Most systems performed very consistently. Although this is a harmonized program using identical phantoms and testing protocols, it is not appropriate to apply universal threshold or target metrics across the machine types because the systems have different non-linear reconstruction algorithms and image display filters. It was found to be more useful to assess pass/fail criteria in terms of relative deviations from baseline values established when a system is first characterized and after equipment is changed. Generally, systems which needed repair failed suddenly, but in retrospect, for a few cases, drops in SDNR and increases in mAs were observed prior to tube failure. TMIST is registered as NCT03233191 by Clinicaltrials.gov.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Mamografía/métodos , Mama , Neoplasias de la Mama/diagnóstico por imagen , Algoritmos , Control de Calidad , Fantasmas de Imagen
2.
Med Phys ; 50(12): 7427-7440, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37824821

RESUMEN

PURPOSE: A comprehensive, centrally-monitored physics quality control (QC) program was developed for the Tomosynthesis Imaging Screening Trial (TMIST), a randomized controlled trial of digital breast tomosynthesis (TM) versus digital mammography (DM) for cancer screening. As part of the program, in addition to a set of phantom-based tests, de-identified data on image acquisition and processing parameters were captured from the DICOM headers of all individual patient images in the trial. These data were analyzed to assess the potential usefulness of header data from digital mammograms and tomosynthesis images of patients for quality assurance in breast imaging. METHODS: Data were automatically extracted from the headers of all de-identified patient mammograms and tomosynthesis images in the TMIST study. Image acquisition parameters and estimated radiation doses were tracked for individual sites, systems and across system types. These parameters included (among others) kV, target/filter use, number of acquired views per examination, AEC mode, compression thickness and force and detector temperature. Consistency of manually entered study data parameters (subject ID, screening time-point) from TMIST was evaluated. Preliminary observations from the program are presented. RESULTS: We report on data from 812 651 images from 135 525 examinations acquired between October, 2017 and December, 2022. Data came from 6 system models from 3 manufacturers. There was greater variability both in the number of views used and in the estimated (proxy) doses received in DM exams compared to TM. Mean proxy doses per examination varied among manufacturers from 2.76-4.54 mGy for DM and 3-4.84 mGy for the tomosynthesis component in the TM arm with maximum examination proxy doses of 20 and 26 mGy for DM and TM respectively. Mean proxy doses per examination for the combination examination in TM (tomosynthesis plus digital mammography) varied from 6.6 to 7.6 mGy among manufacturers with a maximum of 44.5 mGy. CONCLUSIONS: Overall, modern digital mammography and tomosynthesis systems used in TMIST have operated very reliably. Doses vary considerably due to variation in the number of views per examination, thickness and fibro-glandularity of the breast, and choices in the use of synthesized versus actual 2D mammography in the TM examination. These data may also be useful in predicting equipment problems. Header information is valuable not only for automated QC, but also for cross-checking accuracy and consistency of data in a clinical study.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Humanos , Femenino , Dosis de Radiación , Mamografía/métodos , Mama/diagnóstico por imagen , Fantasmas de Imagen , Neoplasias de la Mama/diagnóstico por imagen
3.
Anal Chem ; 93(4): 2669-2677, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-33465307

RESUMEN

Existing data acquisition modes such as full-scan, data-dependent (DDA), and data-independent acquisition (DIA) often present limited capabilities in capturing metabolic information in liquid chromatography-mass spectrometry (LC-MS)-based metabolomics. In this work, we proposed a novel metabolomic data acquisition workflow that combines DDA and DIA analyses to achieve better metabolomic data quality, including enhanced metabolome coverage, tandem mass spectrometry (MS2) coverage, and MS2 quality. This workflow, named data-dependent-assisted data-independent acquisition (DaDIA), performs untargeted metabolomic analysis of individual biological samples using DIA mode and the pooled quality control (QC) samples using DDA mode. This combination takes advantage of the high-feature number and MS2 spectral coverage of the DIA data and the high MS2 spectral quality of the DDA data. To analyze the heterogeneous DDA and DIA data, we further developed a computational program, DaDIA.R, to automatically extract metabolic features and perform streamlined metabolite annotation of DaDIA data set. Using human urine samples, we demonstrated that the DaDIA workflow delivers remarkably improved data quality when compared to conventional DDA or DIA metabolomics. In particular, both the number of detected features and annotated metabolites were greatly increased. Further biological demonstration using a leukemia metabolomics study also proved that the DaDIA workflow can efficiently detect and annotate around 4 times more significant metabolites than DDA workflow with broad MS2 coverage and high MS2 spectral quality for downstream statistical analysis and biological interpretation. Overall, this work represents a critical development of data acquisition mode in untargeted metabolomics, which can greatly benefit untargeted metabolomics for a wide range of biological applications.


Asunto(s)
Exactitud de los Datos , Metabolómica/métodos , Programas Informáticos , Humanos , Leucemia/metabolismo , Metaboloma , Urinálisis , Flujo de Trabajo
4.
Phys Med Biol ; 60(18): 7179-90, 2015 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-26348995

RESUMEN

To develop tables of normalized glandular dose coefficients D(g)N for a range of anode-filter combinations and tube voltages used in contemporary breast imaging systems. Previously published mono-energetic D(g)N values were used with various spectra to mathematically compute D(g)N coefficients. The tungsten anode spectra from TASMICS were used; molybdenum and rhodium anode-spectra were generated using MCNPX Monte Carlo code. The spectra were filtered with various thicknesses of Al, Rh, Mo or Cu. An initial half value layer (HVL) calculation was made using the anode and filter material. A range of the HVL values was produced with the addition of small thicknesses of polymethyl methacrylate (PMMA) as a surrogate for the breast compression paddle, to produce a range of HVL values at each tube voltage. Using a spectral weighting method, D(g)N coefficients for the generated spectra were calculated for breast glandular densities of 0%, 12.5%, 25%, 37.5%, 50% and 100% for a range of compressed breast thicknesses from 3 to 8 cm. Eleven tables of normalized glandular dose (D(g)N) coefficients were produced for the following anode/filter combinations: W + 50 µm Ag, W + 500 µm Al, W + 700 µm Al, W + 200 µm Cu, W + 300 µm Cu, W + 50 µm Rh, Mo + 400 µm Cu, Mo + 30 µm Mo, Mo + 25 µm Rh, Rh + 400 µm Cu and Rh + 25 µm Rh. Where possible, these results were compared to previously published D(g)N values and were found to be on average less than 2% different than previously reported values.Over 200 pages of D(g)N coefficients were computed for modeled x-ray system spectra that are used in a number of new breast imaging applications. The reported values were found to be in excellent agreement when compared to published values.


Asunto(s)
Algoritmos , Mama/fisiopatología , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Espectrometría por Rayos X/métodos , Femenino , Humanos , Modelos Biológicos , Molibdeno , Método de Montecarlo , Dosis de Radiación , Rodio , Tungsteno , Rayos X
5.
Proc Natl Acad Sci U S A ; 112(15): 4749-54, 2015 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-25825721

RESUMEN

The protein synthesis machineries of two distinct phyla of the Animal kingdom, insects of Arthropoda and mammals of Chordata, have different preferences for how to best encode proteins. Nevertheless, arboviruses (arthropod-borne viruses) are capable of infecting both mammals and insects just like arboviruses that use insect vectors to infect plants. These organisms have evolved carefully balanced genomes that can efficiently use the translational machineries of different phyla, even if the phyla belong to different kingdoms. Using dengue virus as an example, we have undone the genome encoding balance and specifically shifted the encoding preference away from mammals. These mammalian-attenuated viruses grow to high titers in insect cells but low titers in mammalian cells, have dramatically increased LD50s in newborn mice, and induce high levels of protective antibodies. Recoded arboviruses with a bias toward phylum-specific expression could form the basis of a new generation of live attenuated vaccine candidates.


Asunto(s)
Arbovirus/fisiología , Genoma Viral , Insectos Vectores/virología , Mamíferos/virología , Animales , Animales Recién Nacidos , Anticuerpos Antivirales/inmunología , Arbovirus/genética , Línea Celular , Línea Celular Tumoral , Chlorocebus aethiops , Codón , Virus del Dengue/genética , Virus del Dengue/inmunología , Virus del Dengue/fisiología , Regulación Viral de la Expresión Génica , Interacciones Huésped-Patógeno/genética , Humanos , Insectos Vectores/citología , Insectos Vectores/genética , Mamíferos/genética , Ratones Endogámicos ICR , Datos de Secuencia Molecular , ARN Helicasas/genética , ARN Helicasas/inmunología , ARN Helicasas/metabolismo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Serina Endopeptidasas/genética , Serina Endopeptidasas/inmunología , Serina Endopeptidasas/metabolismo , Vacunas Atenuadas/inmunología , Células Vero , Proteínas no Estructurales Virales/genética , Proteínas no Estructurales Virales/inmunología , Proteínas no Estructurales Virales/metabolismo , Virosis/inmunología , Virosis/virología
6.
PLoS One ; 7(1): e29270, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22238597

RESUMEN

AOC3 is highly expressed in adipocytes and smooth muscle cells, but its function in these cells is currently unknown. The in vivo substrate(s) of AOC3 is/are also unknown, but could provide an invaluable clue to the enzyme's function. Expression of untagged, soluble human AOC3 in insect cells provides a relatively simple means of obtaining pure enzyme. Characterization of enzyme indicates a 6% titer for the active site 2,4,5-trihydroxyphenylalanine quinone (TPQ) cofactor and corrected k(cat) values as high as 7 s(-1). Substrate kinetic profiling shows that the enzyme accepts a variety of primary amines with different chemical features, including nonphysiological branched-chain and aliphatic amines, with measured k(cat)/K(m) values between 10(2) and 10(4) M(-1) s(-1). K(m)(O(2)) approximates the partial pressure of oxygen found in the interstitial space. Comparison of the properties of purified murine to human enzyme indicates k(cat)/K(m) values that are within 3 to 4-fold, with the exception of methylamine and aminoacetone that are ca. 10-fold more active with human AOC3. With drug development efforts investigating AOC3 as an anti-inflammatory target, these studies suggest that caution is called for when screening the efficacy of inhibitors designed against human enzymes in non-transgenic mouse models. Differentiated murine 3T3-L1 adipocytes show a uniform distribution of AOC3 on the cell surface and whole cell K(m) values that are reasonably close to values measured using purified enzymes. The latter studies support a relevance of the kinetic parameters measured with isolated AOC3 variants to adipocyte function. From our studies, a number of possible substrates with relatively high k(cat)/K(m) have been discovered, including dopamine and cysteamine, which may implicate a role for adipocyte AOC3 in insulin-signaling and fatty acid metabolism, respectively. Finally, the demonstrated AOC3 turnover of primary amines that are non-native to human tissue suggests possible roles for the adipocyte enzyme in subcutaneous bacterial infiltration and obesity.


Asunto(s)
Adipocitos/metabolismo , Amina Oxidasa (conteniendo Cobre)/genética , Amina Oxidasa (conteniendo Cobre)/aislamiento & purificación , Amina Oxidasa (conteniendo Cobre)/fisiología , Moléculas de Adhesión Celular/genética , Moléculas de Adhesión Celular/aislamiento & purificación , Moléculas de Adhesión Celular/fisiología , Células 3T3-L1 , Adipocitos/enzimología , Adipocitos/fisiología , Amina Oxidasa (conteniendo Cobre)/metabolismo , Animales , Bacterias/metabolismo , Fenómenos Fisiológicos Bacterianos/genética , Moléculas de Adhesión Celular/metabolismo , Células Cultivadas , Drosophila , Activación Enzimática/fisiología , Regulación Enzimológica de la Expresión Génica/fisiología , Humanos , Cinética , Ratones , Obesidad/genética , Obesidad/metabolismo , Permeabilidad , Transfección
7.
Med Phys ; 33(3): 719-36, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16878575

RESUMEN

The Digital Mammography Imaging Screening Trial, conducted by the American College of Radiology Imaging Network, is a clinical trial designed to compare the accuracy of full-field digital mammography (FFDM) versus screen-film mammography in a screening population. Five FFDM systems from four manufacturers (Fischer, Fuji, General Electric, and Lorad) were employed in the study at 35 clinical sites. A core physics team devised and implemented tests to evaluate these systems. A detailed description of physics and quality control tests is presented, including estimates of: mean glandular dose, modulation transfer function (MTF), 2D noise power spectra, and signal-to-noise ratio (SNR). The mean glandular doses for the standard breast ranged from 0.79 to 2.98 mGy, with 1.62 mGy being the average across all units and machine types. For the five systems evaluated, the MTF dropped to 50% at markedly different percentages (22% to 87%) of the Nyquist limit, indicating that factors other than detector element (del) size have an important effect on spatial resolution. Noise power spectra and SNR were measured; however, we found that it was difficult to standardize and compare these between units. For each machine type, the performance as measured by the tests was very consistent, and no predictive benefit was seen for many of the tests during the 2-year period of the trial. It was found that, after verification of proper operation during acceptance testing, if systems failed they generally did so suddenly rather than through gradual deterioration of performance. Because of the relatively short duration of this study further, investigation of the long-term failure characteristics of these systems is advisable.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/patología , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Procesamiento de Señales Asistido por Computador/instrumentación , Algoritmos , Artefactos , Neoplasias de la Mama/diagnóstico , Ensayos Clínicos como Asunto , Humanos , Mamografía/instrumentación , Mamografía/normas , Fantasmas de Imagen , Control de Calidad , Dosis de Radiación , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Pantallas Intensificadoras de Rayos X
8.
Med Phys ; 33(4): 1108-15, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16696488

RESUMEN

The use of a grid increases perceptibility of low contrast objects in mammography. Slot-scan mammography provides a more dose efficient reduction of the scattered radiation reaching the detector than obtained with an antiscatter grid in screen-film or flat-panel digital mammography. In this paper, the potential of using a grid in a slot-scan system to provide a further reduction of scattered radiation is investigated. The components of the digital signal: primary radiation, off-focus radiation, scattered radiation, and optical fluorescence glare in a CsI(Tl) detector were quantified. Based on these measurements, the primary and scatter transmission factors (Tp, Ts), scatter-to-primary ratio (SPR), signal-difference-to-noise ratio (SDNR), and the SDNR improvement factor (K(SDNR)) were obtained. Our results showed that the SPR ranged from 0.05 to 0.19 for breast thicknesses between 2 and 8 cm, respectively. The values of K(SDNR) ranged from 0.85 to 0.94. Because the slot-scanning system has an inherently low SPR, the increase in dose required when the grid is used outweighs the benefit of the small increase in SDNR. It is possible that greater benefit could be achieved by using a grid with a higher Tp, such as obtained using air-core technology.


Asunto(s)
Artefactos , Mamografía/instrumentación , Intensificación de Imagen Radiográfica/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Mamografía/métodos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA