Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev Sci Instrum ; 87(2): 02B106, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26931988

RESUMEN

Existing RF ion sources for accelerators have specific efficiencies for H(+) and H(-) ion generation ∼3-5 mA/cm(2) kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) surface plasma source (SPS) described here was developed to improve H(-) ion production efficiency, reliability, and availability. In SA RF ion source, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm(2) kW. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power ∼1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with ∼4 kW RF. Continuous wave (CW) operation of the SA SPS has been tested on the test stand. The general design of the CW SA SPS is based on the pulsed version. Some modifications were made to improve the cooling and cesiation stability. CW operation with negative ion extraction was tested with RF power up to ∼1.2 kW in the plasma with production up to Ic = 7 mA. A stable long time generation of H(-) beam without degradation was demonstrated in RF discharge with AlN discharge chamber.

2.
Vet J ; 198(1): 70-5, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23702280

RESUMEN

The outcome of spinal surgery in dogs with absent voluntary motor function and nociception following intervertebral disc (IVD) herniation is highly variable, which likely attests to differences in the severity of spinal cord damage. This retrospective study evaluated the extent to which neurological signs correlated with histologically detected spinal cord damage in 60 dogs that were euthanased because of thoracolumbar IVD herniation. Clinical neurological grades correlated significantly with the extent of white matter damage (P<0.001). However, loss of nociception also occurred in 6/31 (19%) dogs with relatively mild histological changes. The duration of clinical signs, Schiff-Sherrington posture, loss of reflexes and pain on spinal palpation were not significantly associated with the severity of spinal cord damage. Although clinical-pathological correlation was generally good, some clinical signs frequently thought to indicate severe cord injury did not always correlate with the degree of cord damage, suggesting functional rather than structural impairment in some cases.


Asunto(s)
Enfermedades de los Perros/patología , Perros , Degeneración del Disco Intervertebral/veterinaria , Desplazamiento del Disco Intervertebral/veterinaria , Vértebras Lumbares/patología , Traumatismos de la Médula Espinal/veterinaria , Vértebras Torácicas/patología , Animales , Enfermedades de los Perros/etiología , Perros/lesiones , Femenino , Degeneración del Disco Intervertebral/complicaciones , Degeneración del Disco Intervertebral/patología , Desplazamiento del Disco Intervertebral/complicaciones , Desplazamiento del Disco Intervertebral/patología , Vértebras Lumbares/lesiones , Masculino , Nocicepción , Postura , Reflejo Anormal , Estudios Retrospectivos , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/patología , Suiza , Vértebras Torácicas/lesiones
3.
Rev Sci Instrum ; 83(2): 02A712, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380221

RESUMEN

A prototype RF H(-) surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA∕kW. Control experiments with H(-) beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.

4.
Rev Sci Instrum ; 83(2): 02A725, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380234

RESUMEN

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent ∼38 mA peak current in the linac and an availability of ∼90%. H(-) beam pulses (∼1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, ∼60 kW) of a copper antenna that has been encased with a thickness of ∼0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of ∼99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of ∼75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance∕installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to ∼100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

5.
FEMS Microbiol Lett ; 146(1): 53-8, 1997 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-8997706

RESUMEN

Citrate synthase (EC 4.1.3.7) was purified from the acidophilic bacterium Acetobacter europaeus to electrophoretic homogeneity. The specific activity was 228 units/mg of protein during the exponential ethanol-oxidation growth phase. The enzyme has a molecular mass of 280 kDa and is a hexamer with a subunit size of 46 kDa. The apparent K(m) values were 20 microM for oxaloacetate and 51 microM for acetyl-CoA. Unlike citrate synthase from other Gram-negative bacteria, the activity of the enzyme was inhibited by ATP, slightly enhanced by ADP and not effected by NADH. Acetate caused activation of the enzyme. The pH optimum on the citrate synthase activity in vitro was 8.1. The amino-terminal amino acid sequence of the purified enzyme was ENGKSATISLNGKDVALPVL.


Asunto(s)
Acetobacter/enzimología , Citrato (si)-Sintasa/aislamiento & purificación , Acetobacter/genética , Adenosina Difosfato/farmacología , Adenosina Trifosfato/farmacología , Secuencia de Aminoácidos , Citrato (si)-Sintasa/genética , Citrato (si)-Sintasa/metabolismo , Activación Enzimática/efectos de los fármacos , Inhibidores Enzimáticos/farmacología , Concentración de Iones de Hidrógeno , Cinética , Datos de Secuencia Molecular , Peso Molecular , NAD/farmacología , Conformación Proteica
6.
FEBS Lett ; 344(2-3): 261-5, 1994 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-7514546

RESUMEN

Digestion of the proteinase inhibitor aprotinin, by clostripain, a cysteine proteinase, yielded five oligopeptide fragments. Two fragments exhibited both antiviral and antibacterial activities, two fragments only antiviral activity, and one fragment showed no antimicrobial activity. One of the former oligopeptides showed antiviral activity against human herpes simplex virus type 1 and bovine parainfluenza virus type 3. It consisted of the hexapeptide Y-F-Y-N-A-K corresponding to amino acids 21-26 of intact aprotinin. An identical synthetic peptide had the same antiviral spectrum as the natural hexapeptide, exhibited no antibacterial activity, and was also devoid of trypsin inhibiting activity. Intact aprotinin, in contrast, is ineffective against human herpes simplex virus 1 and bovine parainfluenza virus 3 but possesses antibacterial properties against several bacterial species [(1992) J. Appl. Bact. 72, 180-187].


Asunto(s)
Antivirales/química , Aprotinina/química , Fragmentos de Péptidos/química , Secuencia de Aminoácidos , Antivirales/farmacología , Aprotinina/metabolismo , Aprotinina/farmacología , Bacterias/efectos de los fármacos , Cisteína Endopeptidasas/metabolismo , Herpesvirus Humano 1/efectos de los fármacos , Datos de Secuencia Molecular , Virus de la Parainfluenza 3 Humana/efectos de los fármacos , Fragmentos de Péptidos/metabolismo , Fragmentos de Péptidos/farmacología , Inhibidores de Tripsina/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA