Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Med Phys ; 34(11): 4348-58, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18072500

RESUMEN

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM and US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLEz of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FREz of 0.76 mm and a TREz of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.


Asunto(s)
Biopsia/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Técnicas Estereotáxicas , Ultrasonografía Mamaria/métodos , Ultrasonografía/métodos , Animales , Pollos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Mamografía/instrumentación , Modelos Estadísticos , Fantasmas de Imagen , Ultrasonografía Mamaria/instrumentación , Rayos X
2.
Ultrasonics ; 42(1-9): 769-74, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15047381

RESUMEN

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are commonly used techniques for breast biopsy. While SM provides 3D targeting information and US provides real-time guidance, both techniques have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently 2D, requiring a skilled physician for both safety and accuracy. We have developed a 3D US-guided biopsy system to integrate with SM. The dual modality breast biopsy system combines the advantages of both approaches with 3D US and SM targeting, near real-time 3D and real-time 2D US guidance, breast stabilisation and a confined needle trajectory. Our goal is to be able to biopsy a larger percentage of suspicious masses using ultrasound, by clarifying ambiguous structures with mammographic imaging. Using breast phantoms, we have shown that our ultrasound guided biopsy system was capable of targeting artificial lesions that were 3.2 mm in diameter, with a 96% success rate. Through this study, we also demonstrated that our system was equivalent to current clinical practice, for an in vitro biopsy task. Metal beads in known relative positions allowed us to determine the geometry of the SM system, so that stereotactic mammography could be registered to 3D US images. The target registration error was found to be 1.6 mm. This error was dominated by positioning error in the vertical direction (perpendicular to the film surface). As an adjunct to SM, we propose that 3D US could provide more complete imaging information for target identification and real-time monitoring of needle insertion, as well as providing a means for rapid confirmation of biopsy success.


Asunto(s)
Biopsia con Aguja/métodos , Mama/patología , Imagenología Tridimensional , Ultrasonografía Mamaria , Femenino , Humanos , Fantasmas de Imagen
3.
Phys Med Biol ; 49(24): 5529-46, 2004 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-15724540

RESUMEN

Poly(vinyl alcohol) cryogel, PVA-C, is presented as a tissue-mimicking material, suitable for application in magnetic resonance (MR) imaging and ultrasound imaging. A 10% by weight poly(vinyl alcohol) in water solution was used to form PVA-C, which is solidified through a freeze-thaw process. The number of freeze-thaw cycles affects the properties of the material. The ultrasound and MR imaging characteristics were investigated using cylindrical samples of PVA-C. The speed of sound was found to range from 1520 to 1540 m s(-1), and the attenuation coefficients were in the range of 0.075-0.28 dB (cm MHz)(-1). T1 and T2 relaxation values were found to be 718-1034 ms and 108-175 ms, respectively. We also present applications of this material in an anthropomorphic brain phantom, a multi-volume stenosed vessel phantom and breast biopsy phantoms. Some suggestions are made for how best to handle this material in the phantom design and development process.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Alcohol Polivinílico/química , Técnica de Sustracción , Ultrasonografía/instrumentación , Animales , Materiales Biomiméticos/análisis , Materiales Biomiméticos/química , Mama/citología , Pollos , Criopreservación/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Ensayo de Materiales , Alcohol Polivinílico/análisis , Ultrasonografía/métodos
4.
Med Image Anal ; 6(3): 301-12, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12270234

RESUMEN

We have designed a prototype three-dimensional ultrasound guidance (3D USB) apparatus to improve the breast biopsy procedure. Features from stereotactic mammography and free-hand US-guided biopsy have been combined with 3D US imaging. This breast biopsy apparatus accurately guides a needle into position for the sampling of target tissue. We have evaluated this apparatus in three stages. First, by testing the placement accuracy of a needle in a tissue mimicking phantom. Second, with tissue mimicking phantoms that had embedded lesions for biopsy. Finally, by comparison to free-hand US-guided biopsy, using chicken breast phantoms. The first two stages of evaluation quantified the mechanical biases in the 3D USB apparatus. Compensating for these, a 96% success rate in targeting 3.2 mm "lesions" in chicken breast phantoms was achieved when using the 3D USB apparatus. The expert radiologists performing biopsies with free-hand US guidance achieved a 94.5% success rate. This has proven an equivalence between our apparatus, operated by non-experts, and free-hand biopsy performed by expert radiologists, for 3.2 mm lesions in vitro, with a 95% confidence.


Asunto(s)
Biopsia con Aguja/instrumentación , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Gráficos por Computador , Imagenología Tridimensional/instrumentación , Técnicas Estereotáxicas/instrumentación , Ultrasonografía Mamaria/instrumentación , Animales , Biopsia con Aguja/métodos , Pollos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Imagenología Tridimensional/métodos , Técnicas In Vitro , Modelos Estadísticos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía Mamaria/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA