Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
PLoS One ; 18(12): e0295517, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38064479

RESUMEN

PURPOSE: To evaluate the laser power stability of the SubCyclo probe for micropulse transscleral cyclophotocoagulation after repeated use. MATERIALS AND METHODS: This experimental study involved 6 new probes. Each probe was connected to the SubCyclo mode (2,000 mW power, 31.3% duty cycle, and 100 seconds duration) of the Vitra 810 laser delivery system (Quantel Medical, France). Laser power measurements were taken using a calibrated laser power meter (Nova, Ophir Optronics Solutions, Israel) every 10 seconds from 10 to 90 seconds during each of the 40 cycles. Intra-rater reliability was assessed using intraclass correlation (ICC). A linear mixed model for repeated measures and pairwise comparisons with Bonferroni adjustment were used for the analysis. RESULTS: The mean (SD) power outputs of all probes for the first cycle and all cycles were 421.9 (19.7) mW and 436.7 (16.1) mW, respectively. During the first cycle, the mean (SD) laser power gradually decreased from 444.3 (13.4) mW at 10 seconds to 407.3 (17.0) mW at 90 seconds (Fig 3). For all cycles, the power was 446.0 (13.6) mW at 10 seconds and gradually declined to 426.8 (21.0) mW at 90 seconds. Pairwise comparisons revealed significant differences in mean laser power outputs after 16 cycles of repeated use compared to the first cycle. The ICC estimate (95% CI) for intra-rater reliability was 0.96 (0.89, 0.99). CONCLUSIONS: The SubCyclo probe maintains stable laser power outputs throughout repeated use for up to 16 cycles, with a significant increase observed after 16 cycles.


Asunto(s)
Glaucoma , Presión Intraocular , Humanos , Coagulación con Láser , Reproducibilidad de los Resultados , Glaucoma/cirugía , Rayos Láser , Cuerpo Ciliar , Resultado del Tratamiento , Estudios Retrospectivos , Esclerótica/cirugía
2.
J Glaucoma ; 31(4): 274-279, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35353783

RESUMEN

PURPOSE: The aim was to report long-term surgical success of primary congenital glaucoma (PCG) patients in Thailand. MATERIALS AND METHODS: PCG patients who underwent one of the following primary operations: trabeculotomy, goniotomy, trabeculectomy, combined trabeculotrabeculectomy (CTT) and diode transscleral cyclophotocoagulation (TSCPC) between January 1992 and January 2018 were reviewed. Surgical success was defined as intraocular pressure (IOP) between 5 and 21 mm Hg with or without antiglaucoma medications. Failure was defined as IOP ≤5 or ≥21 mm Hg for 2 consecutive visits, or when an additional glaucoma surgery was required to control IOP. Survival curves were analyzed using multilevel mixed-effect Weibull model. RESULTS: A total of 81 eyes from 55 PCG patients were included. Surgical procedures involved 20 goniotomies, 15 trabeculotomies, 16 trabeculectomies, 15 CTT, and 15 TSCPC. Median follow-up time was 24 months (interquartile range: 9 to 60 mo). Overall success rates were 68.8% at 1 year, 63.8% at 3 years, and 53.7% at 5 years. All types of surgery except TSCPC had comparable cumulative 1 year success rates ranging from 78.5% to 83.3%. Cumulative success rates of trabeculotomy (80.05%) and CTT (79.4%) were maintained at 3 and 5 years and were the highest among all procedures at 5 years. TSCPC had a significantly lower success rate compared with other types of surgery (hazard ratio: 7.4 to 13.1, all P=0.01). All patients receiving primary TSCPC showed no success at 48 months. CONCLUSION: Primary trabeculotomy and primary CTT demonstrated the highest long-term success rates in PCG patients.


Asunto(s)
Glaucoma , Presión Intraocular , Estudios de Seguimiento , Glaucoma/congénito , Glaucoma/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual
3.
Am J Ophthalmol Case Rep ; 23: 101190, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34409197

RESUMEN

PURPOSE: To report a case of ciliary body metastasis with uncontrolled glaucoma that was successfully treated with micropulse transscleral laser therapy (MPTLT). OBSERVATIONS: A case of a 44-year-old female with uncontrolled glaucoma secondary to ciliary body metastasis from pulmonary adenocarcinoma. Antiglaucoma medications, intravitreal ranibizumab injection and local radiotherapy were ineffective in reducing her intraocular pressure (IOP) and ocular pain. MPTLT using a power setting of 2,000 mW, 31.3% duty cycle, and 140 seconds over 180 degrees demonstrated favorable IOP reduction (from 31 to 8 mmHg) on the first postoperative day without either ocular pain or postoperative complications. IOP remained controlled until she died from hemoperitoneum 18 days after hospital discharge. CONCLUSIONS AND IMPORTANCE: MPTLT can be a safe and effective procedure for IOP control in intraocular metastasis patients with uncontrolled glaucoma.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA