Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(4): 346-351, 2022 Apr 09.
Artículo en Chino | MEDLINE | ID: mdl-35368160

RESUMEN

Objective: To evaluate the pink and white esthetics of conventional and socket shield technique (SST) immediate implant restoration. Methods: Thirty volunteers were recruited according to preset criteria, and were assigned to 3 groups. Natural teeth group (ten undergraduates or postgraduates from Peking University School and Hospital of Stomatology in January 2020, n=10): all volunteers' maxillary anterior teeth were natural teeth with healthy gingiva, and none of the teeth were restored by crowns or composite. Conventional group and SST group (patients had a maxillary central incisor immediate implant placed in Department of Prosthodontics, Peking University School and Hospital of Stomatology during October 2016 to January 2021, n=10 for each group): the volunteer had an unrestored natural maxillary central incisor, and the contralateral maxillary central incisor was restored by conventional or SST immediate implant placement, temporization and all ceramic final restoration, photos were taken 12 months post-surgery. Three groups of evaluators namely layperson (staff from Second Clinical Division of Peking University School and Hospital of Stomatology and 2 family members, n=10), dental students (class 2015 undergraduates from Peking University School and Hospital of Stomatology, n=10) and prosthodontists (from Department of Prosthodontics, Peking University School and Hospital of Stomatology, n=10) were invited to assess the esthetics using pink esthetic score (PES) and white esthetic score (WES). The results were statistically analyzed. Results: PES and WES of natural teeth group [9(8, 10) and 8(7, 10)] were significantly higher than conventional group [7(6,8) and 7(6,9)] (H=287.08, 132.79,P<0.01) and SST group [7(6, 9) and 8(7, 9)] (H=216.01, 101.21, P<0.01). SST group yielded higher PES than the conventional group (H=-71.06, P<0.01), yet had similar WES (H=-31.57, P>0.05). Dental students had significant lower PES and WES than prosthodontists (H=-120.90, -218.86, P<0.01) and layperson (H=-109.55, 134.97, P<0.01). Prosthodontists and layperson got similar PES (H=-11.36, P>0.05), however yielded different WES (H=-83.89, P<0.01). Conclusions: SST immediate implant placement obtained better pink esthetics than conventional protocol 12-month after implant surgery, profession may have significant impact on evaluators during pink and white esthetic evaluation.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Coronas , Estética Dental , Humanos , Maxilar/cirugía , Resultado del Tratamiento
2.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 83-88, 2022 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-35165472

RESUMEN

OBJECTIVE: To investigate the effect of a noval radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet on crosslinking of dentin collagen. METHODS: (1) Twenty intact third molars were collected. The middle dentin discs were prepared for each tooth by low-speed water-cooled Isomet saw, and then immersed in 10% (mass fraction) H3PO4 solution for 16 h to obtain fully demine-ralized dentin collagen. The twenty dentin discs were then randomly divided into five groups. The control group was untreated while the four experimental groups were treated by plasma jet with gas temperature of 4 ℃ for different times (20 s, 30 s, 40 s, and 50 s). The structure and crosslinking degree of dentin collagen were characterized by attenuated total reflection-Fourier transform infrared spectroscopy. The surface morphology of demineralized dentin was observed by scanning electron microscope, and the microstructure was observed by transmission electron microscope. (2) Fourty non-caries third molars were collected to prepare 5 g fine dentin powder, then completely demineralized with 10% H3PO4 solution. The control group was untreated, while the four experimental groups were treated by plasma jet for 20 s, 30 s, 40 s and 50 s. The crosslinking degree of each group was determined by ninhydrin colorimetric method. (3) Forty intact third molars were collected to obtain dentin strips. Only two central symmetrical dentin strips (nasty 80) were taken from each tooth and immersed in 10% H3PO4 solution for 16 h to obtain fully demineralized dentin collagen. Eighty dentine collagen fiber strips were randomly divided into five groups. The control group was untreated and the axial surfaces of dentin collagen fiber strips in the expe-rimental groups were treated with the plasma jet for 20 s, 30 s, 40 s and 50 s. The ultimate tensile strength of dentin was measured by universal mechanical machine. RESULTS: (1) The surface morphology of demineralized dentin observed by scanning electron microscope showed that the network structure of collagen fibers on the surface of demineralized dentin treated with the plasma jet for 20 s, 30 s and 40 s could maintain the uncollapsed three-dimensional structure, and part of the microstructure was destroyed after plasma jet treated for 50 s. After being treated by plasma jet for 20 s, 30 s and 40 s, the three-dimensional structure was uncollapsed, and the typical periodic transverse pattern of natural type Ⅰ collagen fiber could be seen. The results of infrared spectra showed that the secondary conformation of dentin collagen fibers was the same as that of the control group after being treated with the plasma jet, and the intensity of amide band was significantly increased after being treated for 30 s and 40 s. (2) The results of ninhydrin crosslinking test showed that the crosslinking ratio of dentin collagen treated by plasma jet for 30 s and 40 s was the highest, and the difference was statistically significant (P < 0.05). (3) The results of dentin ultimate tensile strength showed that the control group was (1.67±0.24) MPa, and the plasma jet treated 20 s, 30 s, 40 s and 50 s groups were (4.21±0.15) MPa, (7.06±0.30) MPa, (7.32±0.27) MPa, and (6.87±0.17) MPa, which were significantly different from that of the control group (P < 0.05). CONCLUSION: The novel RF-APGD plasma jet treatment can promote the crosslinking degree of demineralized dentin collagen and improve their ultimate tensile strength.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Colágeno , Dentina , Microscopía Electrónica de Rastreo , Resistencia a la Tracción
3.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(2): 390-395, 2020 Dec 30.
Artículo en Chino | MEDLINE | ID: mdl-33879916

RESUMEN

OBJECTIVE: To investigate the blood pressure and heart rate changes and influencing factors during single dental implant surgery. METHODS: A retrospective cohort study was conducted. Six hundred and forty cases underwent single dental implant placement in Department of Prosthodontics, Peking University School and Hospital of Stomatology from January 2016 to December 2016 were recruited in this study according to the inclusion and exclusion criteria. They were divided into different groups according to the exposure factors which were patient characteristics (gender, age) and surgical procedures (immediate placement, flap elevation, bone grafting). The correlation between blood pressure and heart rate variability during single dental implant surgery and the patient characteristics and surgical procedures were analyzed. RESULTS: The average systolic blood pressure variability was 9.47%±6.45% (maximum 46.04%), the average diastolic blood pressure variability was 12.18%±9.39% (maximum 88.00%), and the average heart rate variability was 10.59%±7.68% (maximum 49.12%). The effects of age and bone grafting on blood pressure variability, and of gender and immediate placement on heart rate variability, were statistically significant (P < 0.05), respectively. The incidence of abnormal intraoperative blood pressure rise was 4.69%, of which there were 4 cases (0.63%) of systolic blood pressure ≥180 mmHg and/or diastolic blood pressure ≥110 mmHg. The incidence of abnormal intraoperative heart rate rise was 6.72%. Hierarchical analysis showed a higher risk of abnormal intraoperative blood pressure rise in the elderly (≥60 years) male patients [P < 0.05, RR=3.409 (95%CI: 1.155-10.062) ] and flap elevation with bone grafting cases [P < 0.05, RR=2.382 (95%CI: 1.126-5.040)], respectively. There was no statistically significant association between abnormal heart rate rise and patient characteristics or surgical procedures (P>0.05). CONCLUSION: There was a certain risk of blood pressure and heart rate variability during dental implant surgery. Elderly male patients and flap elevation with bone grafting were risk factors of abnormal intraoperative blood pressure rise.


Asunto(s)
Implantes Dentales , Anciano , Presión Sanguínea , Implantación Dental Endoósea , Frecuencia Cardíaca , Humanos , Masculino , Maxilar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
4.
Beijing Da Xue Xue Bao Yi Xue Ban ; 51(2): 315-320, 2019 Apr 18.
Artículo en Chino | MEDLINE | ID: mdl-30996375

RESUMEN

OBJECTIVE: To evaluate the effect of different cold atmospheric plasma (CAP) treatment on the surface chemical and physical properties of zirconia and adhensive behaviour of human gingival fibroblasts (HGFs) cultured on zirconia disks. METHODS: The zirconia disks were divided into four groups and treated using helium, argon and mixture of argon and oxygen cold atmospheric plasma for 90 s or left untreated. The surface morphology, wettability and chemical elements were analyzed right after treatment. Human gingival fibroblasts were grown from biopsies obtained from a periodontally healthy human subject during periodontal surgery. HGFs were seeded on zirconia disk, and cells density was measured at the time point of 3 hours. Indirect immunofluorescence (IIF) was performed for morphometric examination at the time point of 3 hours. RESULTS: The crystallographic structure of zirconia was analyzed previously and the results suggested that it fitted the properties of zirconium yttrium oxide. After helium, argon and mixture of argon and oxygen cold atmospheric plasma treatment, the surface morphology and roughness of zirconia disks remained the same. The contact angle of zirconia decreased significantly(P<0.05)after CAP treatment: from 68.38° to 17.90°. After different CAP plasmas treatment, the atomic percentage of carbon on the outermost surface of the three groups decreased, as did the surface C/O ratio. The surface C/O ratio of zirconia decreased from 1.07 to 0.33. Fibroblasts density increased on CAP treated disks, especially the ones treated by mixture of argon and oxygen CAP(P<0.05). Cells of the three CAP plasma treatment groups spread better and had more protrusions, as well as larger surficial areas. CONCLUSION: Based on the results of this study after being treated by different kinds of CAP plasmas for 90 s, the surface wettability increased and the elements changed significantly with no changes in the tomography and roughness of the materials. The CAP treatment enhances the adhensive behavior of fibroblasts on zirconia by increasing the oxygen functional groups and promoting the cell density. Wettability of zirconia, an important physicochemical property, has a vital influence on the cell behaviors.


Asunto(s)
Encía , Circonio , Fibroblastos , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
5.
Eur Rev Med Pharmacol Sci ; 21(6): 1290-1295, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28387899

RESUMEN

OBJECTIVE: Chemokine receptor and its ligand participate in viral immunity and HCV infection, which are important inflammatory mediators. The current study showed the different roles of Th cell secreted chemokines CXCR3, CCR5 and CCR6 in chronic liver inflammation after HCV infection. As one important chemokine receptor, the role of polypeptide property and ligand level in HCV prognosis is still unclear. This study aims to investigate gene polymorphism of chemokine genes and ligand level, and their correlation with patient liver function, to provide evidence for HCV prognosis and chronic transition mechanism. PATIENTS AND METHODS: Whole blood samples were collected. Participants were divided into chronic hepatitis, HCV cirrhosis and self-clearance groups. Chemokine level, gene polymorphism of CXCR3 gene at loci rs2280964 and liver index were measured to analyze their correlation with HCV infection or prognosis. RESULTS: Gene polymorphism of CXCR3 at loci rs22809064 is one factor-affecting prognosis of HCV patients. CG genotype at these loci is one independent risk factor affecting chronic HCV infection. IP-10, Mig and I-TAC levels were significantly elevated in chronic hepatitis group or HCV cirrhosis group (p< 0.05 compared to self-clearance group). CONCLUSIONS: Gene polymorphism at rs2280964 locus of chemokine receptor CXCR3 is one possible reason explaining differential processes of chronic transition. CXCR3 ligands IP-10, Mig and I-TAC levels were all significantly elevated in chronic hepatitis and HCV cirrhosis patients, possibly functioning as one clinical index for HCV prognosis.


Asunto(s)
Linfocitos T CD4-Positivos/metabolismo , Hepatitis C Crónica/genética , Receptores CXCR3/genética , Adulto , Quimiocina CXCL10/sangre , Quimiocina CXCL11/sangre , Quimiocina CXCL9/sangre , Femenino , Hepatitis C Crónica/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Polimorfismo Genético
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA