Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
JACC Cardiovasc Interv ; 17(18): 2170-2179, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322365

RESUMEN

BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.


Asunto(s)
Cateterismo Cardíaco , Técnicas de Apoyo para la Decisión , Implantación de Prótesis de Válvulas Cardíacas , Readmisión del Paciente , Valor Predictivo de las Pruebas , Sistema de Registros , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Medición de Riesgo , Masculino , Femenino , Factores de Riesgo , Anciano , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Reproducibilidad de los Resultados , Toma de Decisiones Clínicas , Persona de Mediana Edad
2.
JACC Cardiovasc Interv ; 17(18): 2141-2153, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39243262

RESUMEN

BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).


Asunto(s)
Calcinosis , Cateterismo Cardíaco , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Humanos , Anciano , Masculino , Femenino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Anciano de 80 o más Años , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Calcinosis/mortalidad , Calcinosis/fisiopatología , Calcinosis/terapia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Europa (Continente)
3.
JACC Heart Fail ; 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39269396

RESUMEN

BACKGROUND: Moderate secondary mitral regurgitation (SMR) represents a subgroup of heart failure (HF) patients with treatment restricted to medical therapy. Outcomes in patients with moderate SMR treated with mitral transcatheter edge-to-edge repair (M-TEER) are less well known. OBJECTIVES: The aim of this study was to assess the safety and effectiveness of M-TEER in subjects with moderate SMR using the EXPANDed studies. METHODS: One-year outcomes in subjects from the EXPANDed studies (EXPAND [A Contemporary, Prospective Study Evaluating Real-world Experience of Performance and Safety for the Next Generation of MitraClip Devices] and EXPAND G4 [A Post-Market Study Assessment of the Safety and Performance of the MitraClip G4 System] MitraClip studies) with baseline moderate SMR (2+), per echocardiographic core laboratory (ECL) assessment, were compared with subjects with baseline severe SMR (≥3+). RESULTS: There were 335 subjects with moderate SMR and 525 with severe SMR at baseline per ECL review. Baseline characteristics were similar between the 2 subgroups. After treatment with M-TEER, significant MR reduction was achieved in both groups. Significant left ventricular (LV) reverse remodeling was observed through 1 year, with a >20 mL decrease in LV end-diastolic and end-systolic volumes on average in the moderate SMR group. Significant 1-year improvements in NYHA functional class (>78% NYHA functional class I or II) and quality of life (>20 points on the Kansas City Cardiomyopathy Questionnaire-Overall Summary) were observed in subjects with moderate SMR. Similarly, low rates of major adverse events, all-cause mortality, and HF hospitalizations were observed between the 2 subgroups through 1 year. CONCLUSIONS: In the EXPANDed studies, subjects with moderate SMR treated with M-TEER had improvements similar to subjects with severe SMR in quality of life and positive LV remodeling at 1 year. Future studies are needed to evaluate if M-TEER would be beneficial for HF patients with moderate SMR.

4.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048251

RESUMEN

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Toma de Decisiones Clínicas , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Terminología como Asunto , Valor Predictivo de las Pruebas
5.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866457

RESUMEN

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Asunto(s)
Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Hidrodinámica , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Microtomografía por Rayos X , Humanos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/cirugía , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Persona de Mediana Edad , Factores de Tiempo , Remoción de Dispositivos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Fenómenos Biomecánicos , Ensayo de Materiales , Grabación en Video
6.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776106

RESUMEN

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Asunto(s)
Bioprótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Reoperación/estadística & datos numéricos , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
7.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38660790

RESUMEN

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Asunto(s)
American Heart Association , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estados Unidos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Implantación de Prótesis de Válvulas Cardíacas
9.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
10.
Curr Opin Cardiol ; 39(3): 226-233, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38391273

RESUMEN

PURPOSE OF REVIEW: This review offers insights into percutaneous mitral valve management, emphasizing pivotal trials that contributed to its evolution. RECENT FINDINGS: Mitral regurgitation (MR) is a highly prevalent heart valve disease, with surgical intervention being the gold standard for managing primary MR. However, a notable proportion of patients face ineligibility criteria or are at high surgical risk, particularly in the setting of secondary MR. To fill this gap, transcatheter therapies have emerged as less invasive alternatives. Initially guided by the EVEREST trial criteria, transcatheter leaflet repair techniques have shown impressive technological improvements, addressing nowadays a wide range of anatomical scenarios. Evidence supporting the safety and efficacy of transcatheter leaflet repair is derived from pivotal trials, including EVEREST II, COAPT, MITRA-FR, and CLASP IID, and large multicenter registries including EXPAND, EXPAND G4, and EuroSMR. However, not all patients meet the anatomical and clinical criteria for leaflet repair. For those patients, transcatheter mitral valve replacement may be a minimally invasive option and multiple clinical trials are current underway. SUMMARY: From MitraClip to newer and more innovative technologies, the landscape of percutaneous mitral valve interventions continues to evolve, offering new hopes to patients who may not be ideal candidates for conventional surgery.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
11.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
12.
Can J Cardiol ; 40(2): 250-262, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38042339

RESUMEN

Mitral regurgitation is a prevalent valvular disease, and its management has gained increasing importance because of the aging population. Although traditional surgery remains the gold standard, the field of transcatheter therapies, including transcatheter edge-to-edge repair and, more recently transcatheter mitral valve replacement are advancing and are being explored as viable alternatives, particularly for patients at high surgical risk. It is essential to emphasize the necessity of a multidisciplinary team approach, involving specialized valve teams, imaging experts, cardiac anaesthesiologists, and other relevant specialists, is crucial in achieving optimal outcomes. Furthermore, proper execution of procedures, postprocedural care, and diligent follow-up for these patients are essential components for successful results. It is essential to underscore that traditional mitral valve surgery continues to play a significant role. Simultaneously, it is important to acknowledge the expanding array of transcatheter interventions available for this specific patient population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento
13.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
14.
JTCVS Tech ; 22: 1-12, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38152201

RESUMEN

Objectives: Mitral annular calcification remains a formidable lesion in cardiac surgery with significant perioperative morbidity and mortality, particularly when en bloc annular decalcification is implemented. Respect strategies and hybrid approaches have provided safe alternatives. We report the short-term results of our institution's experience with mitral valve replacement in patients with extensive annular calcification. Methods: This is a retrospective review of 72 consecutive patients with extensive annular calcification who underwent open surgical mitral valve replacement from January 1, 2013, to September 31, 2022. Degree of annular calcification was graded as partial, horseshoe, or circumferential. We excluded patients with calcification involving less than one-third of the annulus and patients with rheumatic heart disease. Results: Mean patient age was 71.6 ± 10.9 years, and 50 (69.4%) were female. There were 51 patients (70.8%) with New York Heart Association class 3 or greater and 47 patients (65.3%) with pulmonary hypertension. There were 41 patients (56.9%) with partial, 12 patients (16.7%) with horseshoe, and 19 patients (26.4%) with circumferential calcification. Fifty-six patients (77.8%) underwent conventional valve replacement. Sixteen patients underwent a hybrid procedure using balloon-expandable devices. Concomitant procedures were performed in 61 patients (84.7%). In-hospital mortality and 1-year survival were 3.57% and 82.8% in the standard valve replacement cohort and 25.0% and 54.7% in the hybrid cohort, respectively. Conclusions: Conventional mitral valve replacement using respect strategies is safe and associated with good outcomes in patients with extensive annular calcification. Hybrid approaches using novel devices should remain as a bailout in select patients because of higher perioperative risks and poor short-term outcomes.

15.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37793121

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
16.
Ann Thorac Surg ; 116(5): 908-932, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37804270

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Comorbilidad , Cateterismo Cardíaco/efectos adversos , Índice de Severidad de la Enfermedad
17.
J Am Coll Cardiol ; 82(17): 1711-1735, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37804294

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
18.
JACC Cardiovasc Interv ; 16(18): 2211-2227, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758379

RESUMEN

BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective trial to evaluate the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with failed surgical bioprostheses or annuloplasty rings and severe mitral annular calcification treated with mitral valve-in-valve (MViV), valve-in-ring (MViR), or valve-in-mitral annular calcification (ViMAC). OBJECTIVES: The aim of this study was to evaluate 5-year outcomes among these patients. METHODS: A multicenter prospective study was conducted among patients at high surgical risk at 13 U.S. sites. Patients underwent MViV (n = 30), MViR (n = 30), or ViMAC (n = 31) and were followed annually for 5 years. Kansas City Cardiomyopathy Questionnaire scores were obtained at baseline and follow-up visits. Echocardiograms were analyzed at independent core laboratories. RESULTS: A total of 91 patients underwent transcatheter mitral valve replacement (February 2015 to December 2017). The mean age was 74.3 ± 8.9 years. At 5-year follow-up, the lowest all-cause mortality was observed in the MViV group (21.4%), 94.7% of patients were in NYHA functional class I or II, and the mean mitral gradient was 6.6 ± 2.5 mm Hg. The MViR and ViMAC groups had higher all-cause mortality (65.5% and 67.9%), most survivors were in NYHA functional classes I and II (50% and 55.6%), and mean mitral gradients remained stable (5.8 ± 0.1 and 6.7 ± 2.5 mm Hg). Significant improvements in Kansas City Cardiomyopathy Questionnaire scores were observed when all 3 arms were pooled. CONCLUSIONS: MViV, MViR, and ViMAC procedures were associated with sustained improvement of heart failure symptoms and quality of life among survivors at 5 years. Transcatheter heart valve function remained stable in all 3 groups. Patients treated with MViV had excellent survival at 5 years, whereas survival was lower in the MViR and ViMAC groups, consistent with underlying disease severity. Patients with more residual mitral regurgitation had higher mortality.


Asunto(s)
Calcinosis , Cardiomiopatías , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Enfermedades Vasculares , Humanos , Anciano , Anciano de 80 o más Años , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Calcinosis/cirugía , Enfermedades Vasculares/etiología
19.
JACC Cardiovasc Interv ; 16(18): 2195-2210, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758378

RESUMEN

Mitral annular calcium (MAC) with severe mitral valvular dysfunction presents a complex problem, as valve replacement, either surgical or transcatheter, is challenging because of anatomy, technical considerations, concomitant comorbidities, and advanced age. The authors review the clinical and anatomical features of MAC that are favorable (green light), challenging (yellow light), or prohibitive (red light) for surgical or transcatheter mitral valve interventions. Under the auspices of the Heart Valve Collaboratory, an expert working group of cardiac surgeons, interventional cardiologists, and interventional imaging cardiologists was formed to develop recommendations regarding treatment options for patients with MAC as well as a proposed grading and staging system using both anatomical and clinical features.


Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/terapia , Calcinosis/diagnóstico por imagen , Calcinosis/terapia , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/terapia
20.
Ann Thorac Surg ; 2023 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-37717882

RESUMEN

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA