Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Eur Biophys J ; 53(3): 123-131, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451329

RESUMEN

We present a new phenomenon resulting from the interaction of magnetic beads with cancer cells in a laser trap formed on a slide containing a depression 16.5 mm in diameter and 0.78 mm of maximum depth. This phenomenon includes the apparent formation and expansion of a dark bubble that attracts and incinerates surrounding matter when it explodes, which leads to a plasma emitting intense radiation that has the appearance of a star on a microscopic scale. We have observed the star-like phenomenon for more than 4 years, and the intensity depends on the laser's power. Measuring the laser power of the dark bubble shows the entrapment of electromagnetic energy as it expands.


Asunto(s)
Imanes , Neoplasias , Rayos Láser , Neoplasias/radioterapia
2.
Int J Radiat Oncol Biol Phys ; 119(3): 946-956, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38300188

RESUMEN

PURPOSE: A first of its kind experimental verification of dose-averaged linear energy transfer (LETd) optimized treatment plans for proton therapy has been carried out using a silicon-on-insulator microdosimeter at the Massachusetts General Hospital (MGH), Boston, USA. METHODS AND MATERIALS: Three clinical treatment plans of a typical ependymoma structure set were designed using the standard clinical approach, the proposed protocol approach, and a one-field approach. The plans were then reoptimized to reduce the LETd-weighted dose in the brain stem. All six plans were delivered in a solid water phantom and the experimental yD‾ measured. RESULTS: After LETd optimization, a reduction in yD‾ was found within the brain stem by an average of 12%, 19%, and 4% for the clinical, protocol, and one-field plans, respectively, while maintaining adequate coverage of the tumor structure. The experimental LETd-weighted doses were in agreement with the treatment planning system calculations and Monte Carlo simulations and reinforced the improvement of the optimization. CONCLUSIONS: This work demonstrates the first experimental verification of the clinical implementation of LETd optimization for patient treatment with proton therapy.


Asunto(s)
Neoplasias Encefálicas , Ependimoma , Transferencia Lineal de Energía , Método de Montecarlo , Fantasmas de Imagen , Terapia de Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Terapia de Protones/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Ependimoma/radioterapia , Ependimoma/diagnóstico por imagen , Radiometría/métodos , Radiometría/instrumentación , Tronco Encefálico/diagnóstico por imagen , Silicio , Órganos en Riesgo/efectos de la radiación
3.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819306

RESUMEN

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Efectividad Biológica Relativa
4.
Nat Commun ; 14(1): 3804, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37365163

RESUMEN

The interleukin-1 family members, IL-1ß and IL-18, are processed into their biologically active forms by multi-protein complexes, known as inflammasomes. Although the inflammasome pathways that mediate IL-1ß processing in myeloid cells have been defined, those involved in IL-18 processing, particularly in non-myeloid cells, are still not well understood. Here we report that the host defence molecule NOD1 regulates IL-18 processing in mouse epithelial cells in response to the mucosal pathogen, Helicobacter pylori. Specifically, NOD1 in epithelial cells mediates IL-18 processing and maturation via interactions with caspase-1, instead of the canonical inflammasome pathway involving RIPK2, NF-κB, NLRP3 and ASC. NOD1 activation and IL-18 then help maintain epithelial homoeostasis to mediate protection against pre-neoplastic changes induced by gastric H. pylori infection in vivo. Our findings thus demonstrate a function for NOD1 in epithelial cell production of bioactive IL-18 and protection against H. pylori-induced pathology.


Asunto(s)
Células Epiteliales , Infecciones por Helicobacter , Interleucina-18 , Proteína Adaptadora de Señalización NOD1 , Animales , Ratones , Células Epiteliales/metabolismo , Infecciones por Helicobacter/metabolismo , Helicobacter pylori , Inflamasomas/metabolismo , Interleucina-18/metabolismo , Interleucina-1beta/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Transducción de Señal , Proteína Adaptadora de Señalización NOD1/metabolismo
5.
J Fr Ophtalmol ; 46(1): 49-56, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36496294

RESUMEN

PURPOSE: To assess the torsional component in patients with vertical strabismus due to thyroid eye disease (TED) and its course after vertical rectus muscle surgery. PATIENTS AND METHODS: Retrospective chart review of patients undergoing vertical strabismus surgery for TED between 1998 and 2017, having undergone pre- and postoperative Harms tangent screen examination. RESULTS: Forty patients (27 women) were identified. A torsional component was present in all patients. Thirty-three patients had a mean excyclotorsion of 4.5° in primary position, increasing to 8.2° in upgaze, associated with restricted elevation. Inferior rectus muscle recession (n=29) reduced the excyclotorsion in all cases. A 4.4° mean incyclotorsion was present in primary position in 7 cases, increasing to 7.1° in downgaze. Superior rectus muscle recession reduced the incyclotorsion in 5/6 cases. The torsional surgical dose-effect relationship was correlated with the amount of preoperative torsion. The field of binocular single vision improved from 6.5% preoperatively to 71.1% after surgery. CONCLUSIONS: Ocular torsion is common in vertical strabismus secondary to TED and is significantly improved by vertical rectus muscle surgery alone. Surgery should be planned according to vertical deviation and motility limitation, and vertical rectus muscles surgery should be considered the first line of treatment, with selective oblique muscle surgery as a second-line option, which was unnecessary in our series.


Asunto(s)
Oftalmopatía de Graves , Estrabismo , Humanos , Femenino , Oftalmopatía de Graves/complicaciones , Oftalmopatía de Graves/diagnóstico , Oftalmopatía de Graves/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos , Resultado del Tratamiento , Músculos Oculomotores/cirugía , Estrabismo/etiología , Estrabismo/cirugía , Estrabismo/diagnóstico , Visión Binocular/fisiología
6.
Ann Oncol ; 33(9): 968-980, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35716907

RESUMEN

BACKGROUND: Mucosal melanoma (MM) is a rare melanoma subtype with distinct biology and poor prognosis. Data on the efficacy of immune checkpoint inhibitors (ICIs) are limited. We determined the efficacy of ICIs in MM, analyzed by primary site and ethnicity/race. PATIENTS AND METHODS: A retrospective cohort study from 25 cancer centers in Australia, Europe, USA and Asia was carried out. Patients with histologically confirmed MM were treated with anti-programmed cell death protein 1 (PD-1) ± ipilimumab. Primary endpoints were response rate (RR), progression-free survival (PFS), overall survival (OS) by primary site (naso-oral, urogenital, anorectal, other), ethnicity/race (Caucasian, Asian, Other) and treatment. Univariate and multivariate Cox proportional hazards model analyses were conducted. RESULTS: In total, 545 patients were included: 331 (63%) Caucasian, 176 (33%) Asian and 20 (4%) Other. Primary sites included 113 (21%) anorectal, 178 (32%) urogenital, 206 (38%) naso-oral and 45 (8%) other. Three hundred and forty-eight (64%) patients received anti-PD-1 and 197 (36%) anti-PD-1/ipilimumab. RR, PFS and OS did not differ by primary site, ethnicity/race or treatment. RR for naso-oral was numerically higher for anti-PD-1/ipilimumab [40%, 95% confidence interval (CI) 29% to 54%] compared with anti-PD-1 (29%, 95% CI 21% to 37%). Thirty-five percent of patients who initially responded progressed. The median duration of response (mDoR) was 26 months (95% CI 18 months-not reached). Factors associated with short PFS were Eastern Cooperative Oncology Group (ECOG) performance status (PS) ≥3 (P < 0.01), lactate dehydrogenase (LDH) more than the upper limit of normal (ULN) (P = 0.01), lung metastases (P < 0.01) and ≥1 previous treatments (P < 0.01). Factors associated with short OS were ECOG PS ≥1 (P < 0.01), LDH >ULN (P = 0.03), lung metastases (P < 0.01) and ≥1 previous treatments (P < 0.01). CONCLUSIONS: MM has poor prognosis. Treatment efficacy of anti-PD-1 ± ipilimumab was similar and did not differ by ethnicity/race. Naso-oral primaries had numerically higher response to anti-PD-1/ipilimumab, without difference in survival. The addition of ipilimumab did not show greater benefit over anti-PD-1 for other primary sites. In responders, mDoR was short and acquired resistance was common. Other factors, including site and number of metastases, were associated with survival.


Asunto(s)
Neoplasias Pulmonares , Melanoma , Protocolos de Quimioterapia Combinada Antineoplásica , Estudios de Cohortes , Humanos , Ipilimumab/uso terapéutico , Melanoma/tratamiento farmacológico , Melanoma/patología , Pronóstico , Estudios Retrospectivos
7.
Plant Biol (Stuttg) ; 23 Suppl 1: 162-169, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33236382

RESUMEN

Copper (Cu) pollution of agricultural land is a major threat to crop production. Exogenous chemical treatment is an easily accessible and rapid approach to remediate metal toxicity, including Cu toxicity in plants. We compared the effects of ascobin (ASC; ascorbic acid:citric acid at 2:1) and glutathione (GSH) in mitigation of Cu toxicity in rice. Plants subjected to Cu stress displayed growth inhibition and biomass reduction, which were connected to reduced levels of chlorophylls, RWC, total phenolic compounds, carotenoids and Mg2+ . Increased accumulation of ROS and malondialdehyde indicated oxidative stress in Cu-stressed plants. However, application of ASC or GSH minimized the inhibitory effects of Cu stress on rice plants by restricting Cu2+ uptake and improving mineral balance, chlorophyll content and RWC. Both ASC and GSH pretreatments reduced levels of ROS and malondialdehyde and improved activities of antioxidant enzymes, suggesting their roles in alleviating oxidative damage. A comparison on the effects of ASC and GSH under Cu stress revealed that ASC was more effective in restricting Cu2+ accumulation (69.5% by ASC and 57.1% by GSH), Ca2+ and Mg2+ homeostasis, protection of photosynthetic pigments and activation of antioxidant defence mechanisms [catalase (110.4%), ascorbate peroxidase (76.5%) and guaiacol peroxidase (39.0%) by ASC, and catalase (58.9%) and ascorbate peroxidase (59.9%) by GSH] in rice than GSH, eventually resulting in better protection of ASC-pretreated plants against Cu stress. In conclusion, although ASC and GSH differed in induction of stress protective mechanisms, both were effective in improving rice performance in response to Cu phytotoxicity.


Asunto(s)
Glutatión , Oryza , Antioxidantes , Cobre/toxicidad , Glutatión/metabolismo , Homeostasis , Peróxido de Hidrógeno , Oryza/metabolismo , Estrés Oxidativo , Plantones/metabolismo
8.
Phys Med Biol ; 65(24): 245018, 2020 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-33086208

RESUMEN

Proton beams are widely used worldwide to treat localized tumours, the lower entrance dose and no exit dose, thus sparing surrounding normal tissues, being the main advantage of this treatment modality compared to conventional photon techniques. Clinical proton beam therapy treatment planning is based on the use of a general relative biological effectiveness (RBE) of 1.1 along the whole beam penetration depth, without taking into account the documented increase in RBE at the end of the depth dose profile, in the Bragg peak and beyond. However, an inaccurate estimation of the RBE can cause both underdose or overdose, in particular it can cause the unfavourable situation of underdosing the tumour and overdosing the normal tissue just beyond the tumour, which limits the treatment success and increases the risk of complications. In view of a more precise dose delivery that takes into account the variation of RBE, experimental microdosimetry offers valuable tools for the quality assurance of LET or RBE-based treatment planning systems. The purpose of this work is to compare the response of two different microdosimetry systems: the mini-TEPC and the MicroPlus-Bridge detector. Microdosimetric spectra were measured across the 62 MeV spread out Bragg peak of CATANA with the mini-TEPC and with the Bridge microdosimeter. The frequency and dose distributions of lineal energy were compared and the different contributions to the spectra were analysed, discussing the effects of different site sizes and chord length distributions. The shape of the lineal energy distributions measured with the two detectors are markedly different, due to the different water-equivalent sizes of the sensitive volumes: 0.85 µm for the TEPC and 17.3 µm for the silicon detector. When the Loncol's biological weighting function is applied to calculate the microdosimetric assessment of the RBE, both detectors lead to results that are consistent with biological survival data for glioma U87 cells. Both the mini-TEPC and the MicroPlus-Bridge detector can be used to assess the RBE variation of a 62 MeV modulated proton beam along its penetration depth. The microdosimetric assessment of the RBE based on the Loncol's weighting function is in good agreement with radiobiological results when the 10% biological uncertainty is taken into account.


Asunto(s)
Terapia de Protones , Radiometría , Efectividad Biológica Relativa , Humanos , Silicio
9.
Water Res ; 181: 115929, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32505884

RESUMEN

The principle of subsurface arsenic removal (SAR) from groundwater is based on oxidation and adsorption reactions by infiltrating oxygen into the anoxic aquifer and the immobilization of arsenic (As) onto freshly formed iron (Fe)-(hydr)oxides. In this study, a pilot-scale plant for SAR has been subject to long term testing in the Mekong Delta, Vietnam. Initial concentrations of Fe (8.4 ± 1.3 mg L-1) and As (81 ± 8 µg L-1) in the exploited groundwater were successfully lowered to below the WHO guideline value limits for drinking water of 0.3 mg L-1 and 10 µg L-1, respectively. Adsorption and co-precipitation of As with Fe-(hydr)oxides could be identified as the principal mechanism responsible for the As removal from groundwater, demonstrating the feasibility of SAR as a low-cost and zero-waste solution over a period of two years. However, naturally occurring geochemical reducing conditions and high ammonium levels in the groundwater delayed the removal of manganese (Mn). An additional post-treatment filtration for Mn-removal was temporarily used to comply with the Vietnamese drinking water standard until a Mn-mitigation was achieved by the SAR process. In contrast to most As-remediation technologies, SAR appears to be a long-term, sustainable treatment option with the salient advantage of negligible production of toxic waste, which with ex-situ processes require additionally management costs.


Asunto(s)
Arsénico , Agua Subterránea , Contaminantes Químicos del Agua , Purificación del Agua , Hierro , Vietnam
10.
Rhinology ; 58(4): 413-415, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32533767

RESUMEN

Hemangiomas are tumours originating from the vascular endothelium and can be found throughout the body. These are relatively common in the head and neck regions but very rarely seen in sinonasal region. In the nose and sinuses tumours typically are seen on the septum or lateral nasal wall (1-4). These tumours can be quite vascular and bleed during attempted resection. Incomplete resection does result in residual disease or recurrence so the best approach to achieve complete resection is important.


Asunto(s)
Hemangioma , Neoplasias del Seno Maxilar , Endoscopía , Hemangioma/cirugía , Humanos , Seno Maxilar , Neoplasias del Seno Maxilar/cirugía , Recurrencia Local de Neoplasia
11.
Phys Med Biol ; 65(3): 035004, 2020 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-31842007

RESUMEN

Compact silicon on insulator (SOI) microdosimeters have been used to characterise the radiation field of many different hadron therapy beams. SOI devices are particularly attractive in hadron therapy fields due to their spatial resolution being well suited to the sharp dose gradients at the end of the primary beam's range. Due to the small size of SOI's sensitive volumes (SVs), which are usually ∼1-10 [Formula: see text]m thick, the fabrication of these devices can present challenges which are not as common for more conventional thickness silicon devices such as silicon spectroscopy detectors. Microdosimetry is the study of the energy deposition in micrometre sized volumes representing biological sites and is a powerful approach to estimate the biological effect of radiation on the micron-scale level, in a cell. However, cell sizes vary extensively translating in different energy deposition spectra. This work studies SV thicknesses between 1 and 100 [Formula: see text]m using Geant4 and examines the impact of SV dimensions on microdosimetric quantities. The quantities studied were the frequency mean lineal energy, [Formula: see text], and the dose mean lineal energy, [Formula: see text]. Additionally the relative biological effectiveness (RBE), estimated by the microdosimetric kinetic model (MKM), is also investigated. To study the impact of the SV thickness, SOI microdosimeters were irradiated with proton, [Formula: see text] and [Formula: see text] ion beams with ranges of ∼160 mm, with the microdosimeter being set at various positions along the Bragg curve. It was found that [Formula: see text] was influenced the least in proton beams and increased for heavier ion beams. Conversely, [Formula: see text] was impacted by the SV thickness the most in proton beams and [Formula: see text] was the least. Similar to [Formula: see text], protons were impacted the most by the SV thickness when estimating the RBE using the MKM. The cause of these differences was largely due to the different densities of the delta electron track structure for the case of [Formula: see text] and the energy transferred to the medium from the primary beam for [Formula: see text].


Asunto(s)
Fantasmas de Imagen , Radiometría/instrumentación , Silicio/química , Humanos , Cinética , Método de Montecarlo , Protones , Radiometría/métodos , Efectividad Biológica Relativa
12.
Gynecol Oncol ; 156(1): 77-84, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31796203

RESUMEN

OBJECTIVE: Determine the utility of a clinical calculator to predict the benefit of chemotherapy in stage IA uterine papillary serous cancer (UPSC). PATIENTS AND METHODS: Data were collected from NCDB from years 2010-2014. Based on demographic and surgical characteristics, a clinical score was developed using the random survival forest machine learning algorithm. RESULTS: Of 1,751 patients with stage IA UPSC, 1,012 (58%) received chemotherapy and 739 (42%) did not. Older age (HR 1.06), comorbidities (HR 1.31), larger tumor size (HR 1.27), lymphovascular invasion (HR 1.86), positive peritoneal cytology (HR 2.62), no pelvic lymph node dissection (HR 1.51), and no chemotherapy (HR 2.16) were associated with poorer prognosis. Compared to no chemotherapy, patients who underwent chemotherapy had a 5-year overall survival of 80% vs. 67%. To better delineate those who may derive more benefit from chemotherapy, we designed a clinical calculator capable of dividing patients into low, moderate, and high-risk groups with associated 5-year OS of 86%, 73%, and 53%, respectively. Using the calculator to assess the relative benefit of chemotherapy in each risk group, chemotherapy improved the 5-year OS in the high (42% to 64%; p < 0.001) and moderate risk group (66% to 79%; p < 0.001) but did not benefit the low risk group (84% to 87%; p = 0.29). CONCLUSION: Our results suggest a clinical calculator is useful for counseling and personalizing chemotherapy for stage IA UPSC.


Asunto(s)
Algoritmos , Cistadenocarcinoma Papilar/tratamiento farmacológico , Cistadenocarcinoma Seroso/tratamiento farmacológico , Aprendizaje Automático , Neoplasias Uterinas/tratamiento farmacológico , Anciano , Cistadenocarcinoma Papilar/patología , Cistadenocarcinoma Papilar/cirugía , Cistadenocarcinoma Seroso/patología , Cistadenocarcinoma Seroso/cirugía , Femenino , Humanos , Estadificación de Neoplasias , Nomogramas , Valor Predictivo de las Pruebas , Pronóstico , Modelos de Riesgos Proporcionales , Reproducibilidad de los Resultados , Neoplasias Uterinas/patología , Neoplasias Uterinas/cirugía
13.
Phys Med Biol ; 65(4): 045014, 2020 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-31739291

RESUMEN

Microdosimetry is a particularly powerful method to estimate the relative biological effectiveness (RBE) of any mixed radiation field. This is particularly convenient for therapeutic heavy ion therapy (HIT) beams, referring to ions larger than protons, where the RBE of the beam can vary significantly along the Bragg curve. Additionally, due to the sharp dose gradients at the end of the Bragg peak (BP), or spread out BP, to make accurate measurements and estimations of the biological properties of a beam a high spatial resolution is required, less than a millimetre. This requirement makes silicon microdosimetry particularly attractive due to the thicknesses of the sensitive volumes commonly being ∼10 [Formula: see text]m or less. Monte Carlo (MC) codes are widely used to study the complex mixed HIT radiation field as well as to model the response of novel microdosimeter detectors when irradiated with HIT beams. Therefore it is essential to validate MC codes against experimental measurements. This work compares measurements performed with a silicon microdosimeter in mono-energetic [Formula: see text], [Formula: see text] and [Formula: see text] ion beams of therapeutic energies, against simulation results calculated with the Geant4 toolkit. Experimental and simulation results were compared in terms of microdosimetric spectra (dose lineal energy, [Formula: see text]), the dose mean lineal energy, y  D and the RBE10, as estimated by the microdosimetric kinetic model (MKM). Overall Geant4 showed reasonable agreement with experimental measurements. Before the distal edge of the BP, simulation and experiment agreed within ∼10% for y  D and ∼2% for RBE10. Downstream of the BP less agreement was observed between simulation and experiment, particularly for the [Formula: see text] and [Formula: see text] beams. Simulation results downstream of the BP had lower values of y  D and RBE10 compared to the experiment due to a higher contribution from lighter fragments compared to heavier fragments.


Asunto(s)
Radioterapia de Iones Pesados , Método de Montecarlo , Radiometría/métodos , Silicio , Cinética , Modelos Biológicos , Efectividad Biológica Relativa
14.
Leukemia ; 33(5): 1206-1218, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30356161

RESUMEN

Sézary syndrome (SS) is a rare form of cutaneous T-cell lymphoma often refractory to treatment. SS is defined as adenopathy, erythroderma with high numbers of atypical T cells. This offers an opportunity for new interventions and perhaps antibody-based therapeutic by virtue of its high expression of the TNFR2 oncogene on the tumor cells and on T-regulatory cells (Tregs). Potent human-directed TNFR2 antagonistic antibodies have been created that preferentially target the TNFR2 oncogene and tumor-infiltrating TNFR2+ Tregs. Here we test the therapeutic potential of TNFR2 antagonists on freshly isolated lymphocytes from patients with Stage IVA SS and from healthy controls. SS patients were on a variety of end-stage multi-drug therapies. Baseline burden Treg/T effector (Teff) ratios and the responsiveness of tumor and infiltrating Tregs to TNFR2 antibody killing was studied. We show dose-escalating concentrations of a dominant TNFR2 antagonistic antibody killed TNFR2+ SS tumor cells and thus restored CD26- subpopulations of lymphocyte cell numbers to normal. The abundant TNFR2+ Tregs of SS subjects are also killed with TNFR2 antagonism. Beneficial and rapid expansion of Teff was observed. The combination of Treg inhibition and Teff expansion brought the high Treg/Teff ratio to normal. Our findings suggest a marked responsiveness of SS tumor cells and Tregs, to targeting with TNFR2 antagonistic antibodies. These results show TNFR2 antibodies are potent and efficacious in vitro.


Asunto(s)
Anticuerpos Monoclonales/farmacología , Expresión Génica , Receptores Tipo II del Factor de Necrosis Tumoral/antagonistas & inhibidores , Receptores Tipo II del Factor de Necrosis Tumoral/genética , Síndrome de Sézary/genética , Síndrome de Sézary/patología , Linfocitos T Reguladores/efectos de los fármacos , Linfocitos T Reguladores/metabolismo , Biomarcadores , Línea Celular Tumoral , Proliferación Celular , Dipeptidil Peptidasa 4/metabolismo , Humanos , Inmunofenotipificación , Activación de Linfocitos/efectos de los fármacos , Activación de Linfocitos/inmunología , Estadificación de Neoplasias , Síndrome de Sézary/tratamiento farmacológico , Linfocitos T Reguladores/inmunología
15.
Phys Med Biol ; 63(23): 235007, 2018 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-30468682

RESUMEN

With more patients receiving external beam radiation therapy with protons, it becomes increasingly important to refine the clinical understanding of the relative biological effectiveness (RBE) for dose delivered during treatment. Treatment planning systems used in clinics typically implement a constant RBE of 1.1 for proton fields irrespective of their highly heterogeneous linear energy transfer (LET). Quality assurance tools that can measure beam characteristics and quantify or be indicative of biological outcomes become necessary in the transition towards more sophisticated RBE weighted treatment planning and for verification of the Monte Carlo and analytical based models they use. In this study the RBE for the CHO-K1 cell line in a passively delivered clinical proton spread out Bragg peak (SOBP) is determined both in vitro and using a silicon-on-insulator (SOI) microdosimetry method paired with the modified microdosimetric kinetic model. The RBE along the central axis of a SOBP with 2 Gy delivered at the middle of the treatment field was found to vary between 1.11-1.98 and the RBE for 10% cell survival between 1.07-1.58 with a 250 kVp x-ray reference radiation and between 1.19-2.34 and 0.95-1.41, respectively, for a Co60 reference. Good agreement was found between RBE values calculated from the SOI-microdosimetry-MKM approach and in vitro. A strong correlation between proton lineal energy and RBE was observed particularly in the distal end and falloff of the SOBP.


Asunto(s)
Terapia de Protones/métodos , Animales , Células CHO , Supervivencia Celular , Cricetinae , Cricetulus , Relación Dosis-Respuesta en la Radiación , Humanos , Transferencia Lineal de Energía , Método de Montecarlo , Terapia de Protones/efectos adversos , Efectividad Biológica Relativa
16.
Phys Med Biol ; 63(21): 215007, 2018 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-30353888

RESUMEN

Silicon-on-insulator (SOI) microdosimeters offer a promising method for routine quality assurance (QA) for hadron therapy due to their ease of operation and high spatial resolution. However, one complication which has been shown previously is that the traditional use of the mean chord length, [Formula: see text], calculated using Cauchy's formula, for SOI devices in clinical carbon ion fields is not appropriate due to the strong directionality of the radiation field. In a previous study, we demonstrated that the mean path length, [Formula: see text], which is the mean path of charged particles in the sensitive volume (SV), is a more appropriate method to obtain microdosimetric quantities and biological relevant values, namely the relative biological effectiveness (RBE) by means of the microdosimetric kinetic model. The previous work, which was limited to mono-energetic [Formula: see text] ion beams typical of heavy ion therapy (HIT), is extended here to investigate the [Formula: see text] in a pristine proton beam as well as for spread out Bragg peaks (SOBP) for both proton and carbon ion clinical beams. In addition, the angular dependence of the SOI device for a number of different SV designs is also investigated to quantify the effects which the alignment has on the [Formula: see text]. It is demonstrated that the [Formula: see text] can be accurately estimated along the depth of a pristine or SOBP using the energy deposition spectra for both proton and [Formula: see text] ion beams. This observation allows a quick and accurate estimation of the [Formula: see text] for experimental use.


Asunto(s)
Radioterapia de Iones Pesados/instrumentación , Radiometría/instrumentación , Silicio , Diseño de Equipo , Humanos , Cinética , Control de Calidad , Efectividad Biológica Relativa
17.
Appl Radiat Isot ; 140: 109-114, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30015038

RESUMEN

This paper presents the feasibility study of a novel 3D mesa bridge microdosimeter and its use for BNCT dosimetry. The performance of the microdosimeter was studied using Monte Carlo simulation. The clinical BNCT field at Kyoto University Reactor (KUR) using both thermal and epithermal irradiation modes were used in this study. Results show that this microdosimeter can be utilised as an effective tool to measure microdosimetric spectrum in the BNCT field and experimental validation will follow once KUR is operational.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Radiometría/instrumentación , Partículas alfa/uso terapéutico , Simulación por Computador , Estudios de Factibilidad , Humanos , Litio/análisis , Método de Montecarlo , Neoplasias/radioterapia , Fantasmas de Imagen , Radiometría/estadística & datos numéricos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Silicio
18.
Water Res ; 133: 110-122, 2018 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-29367047

RESUMEN

Arsenic contamination in groundwater is a critical issue and one that raises great concern around the world as the cause of many negative health impacts on the human body, including internal and external cancers. There are many ways to remove or immobilize arsenic, including membrane technologies, adsorption, sand filtration, ion exchange, and capacitive deionization. These exhibit many different advantages and disadvantages. Among these methods, in-situ subsurface arsenic immobilization by aeration and the subsequent removal of arsenic from the aqueous phase has shown to be very a promising, convenient technology with high treatment efficiency. In contrast to most of other As remediation technologies, in-situ subsurface immobilization offers the advantage of negligible waste production and hence has the potential of being a sustainable treatment option. This paper reviews the application of subsurface arsenic removal (SAR) technologies as well as current modeling approaches. Unlike subsurface iron removal (SIR), which has proven to be technically feasible in a variety of hydrogeochemical settings for many years, SAR is not yet an established solution since it shows vulnerability to diverse geochemical conditions such as pH, Fe:As ratio, and the presence of co-ions. In some situations, this makes it difficult to comply with the stringent guideline value for drinking water recommended by the WHO (10 µg L-1). In order to overcome its limitations, more theoretical and experimental studies are needed to show long-term application achievements and help the development of SAR processes into state-of-the-art technology.


Asunto(s)
Arsénico/química , Restauración y Remediación Ambiental/métodos , Hierro/química , Contaminantes Químicos del Agua/química
19.
Clin Genet ; 93(2): 396-400, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28857146

RESUMEN

Deficiencies of mitochondrial respiratory chain complex I frequently result in leukoencephalopathy in young patients, and different mutations in the genes encoding its subunits are still being uncovered. We report 2 patients with cystic leukoencephalopathy and complex I deficiency with recessive mutations in NDUFA2, an accessory subunit of complex I. The first patient was initially diagnosed with a primary systemic carnitine deficiency associated with a homozygous variant in SLC22A5, but also exhibited developmental regression and cystic leukoencephalopathy, and an additional diagnosis of complex I deficiency was suspected. Biochemical analysis confirmed a complex I deficiency, and whole-exome sequencing revealed a homozygous mutation in NDUFA2 (c.134A>C, p.Lys45Thr). Review of a biorepository of patients with unsolved genetic leukoencephalopathies who underwent whole-exome or genome sequencing allowed us to identify a second patient with compound heterozygous mutations in NDUFA2 (c.134A>C, p.Lys45Thr; c.225del, p.Asn76Metfs*4). Only 1 other patient with mutations in NDUFA2 and a different phenotype (Leigh syndrome) has previously been reported. This is the first report of cystic leukoencephalopathy caused by mutations in NDUFA2.


Asunto(s)
Secuenciación del Exoma , Leucoencefalopatías/genética , Mitocondrias/genética , NADH Deshidrogenasa/genética , Niño , Preescolar , Exoma/genética , Femenino , Humanos , Lactante , Enfermedad de Leigh/genética , Enfermedad de Leigh/fisiopatología , Leucoencefalopatías/fisiopatología , Masculino , Mitocondrias/patología , Mutación , Miembro 5 de la Familia 22 de Transportadores de Solutos/genética
20.
Radiat Prot Dosimetry ; 180(1-4): 365-371, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29069515

RESUMEN

Using the CMRP 'bridge' µ+ probe, microdosimetric measurements were undertaken out-of-field using a therapeutic scanning proton pencil beam and in-field using a 12C ion therapy field. These measurements were undertaken at Mayo Clinic, Rochester, USA and at HIMAC, Chiba, Japan, respectively. For a typical proton field used in the treatment of deep-seated tumors, we observed dose-equivalent values ranging from 0.62 to 0.99 mSv/Gy at locations downstream of the distal edge. Lateral measurements at depths close to the entrance and along the SOBP plateau were found to reach maximum values of 3.1 mSv/Gy and 5.3 mSv/Gy at 10 mm from the field edge, respectively, and decreased to ~0.04 mSv/Gy 120 mm from the field edge. The ability to measure the dose-equivalent with high spatial resolution is particularly relevant to healthy tissue dose calculations in hadron therapy treatments. We have also shown qualitatively and quantitively the effects critical organ motion would have in treatment using microdosimetric spectra. Large differences in spectra and RBE10 were observed for treatments where miscalculations of 12C ion range would result in critical structures being irradiated, showing the importance of motion management.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Microtecnología/instrumentación , Fantasmas de Imagen , Terapia de Protones/métodos , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Silicio/química , Simulación por Computador , Humanos , Radiometría/métodos , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA