Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Small ; 19(17): e2208259, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36703532

RESUMEN

Prostate cancer is the most commonly diagnosed tumor disease in men, and its treatment is still a big challenge in standard oncology therapy. Magnetically actuated microrobots represent the most promising technology in modern nanomedicine, offering the advantage of wireless guidance, effective cell penetration, and non-invasive actuation. Here, new biodegradable magnetically actuated zinc/cystine-based microrobots for in situ treatment of prostate cancer cells are reported. The microrobots are fabricated via metal-ion-mediated self-assembly of the amino acid cystine encapsulating superparamagnetic Fe3 O4 nanoparticles (NPs) during the synthesis, which allows their precise manipulation by a rotating magnetic field. Inside the cells, the typical enzymatic reducing environment favors the disassembly of the aminoacidic chemical structure due to the cleavage of cystine disulfide bonds and disruption of non-covalent interactions with the metal ions, as demonstrated by in vitro experiments with reduced nicotinamide adenine dinucleotide (NADH). In this way, the cystine microrobots served for site-specific delivery of Zn2+ ions responsible for tumor cell killing via a "Trojan horse effect". This work presents a new concept of cell internalization exploiting robotic systems' self-degradation, proposing a step forward in non-invasive cancer therapy.


Asunto(s)
Cistina , Neoplasias de la Próstata , Masculino , Humanos , Zinc
2.
Angew Chem Int Ed Engl ; 61(48): e202213505, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36177686

RESUMEN

Photocatalytic micromotors that exhibit wireless and controllable motion by light have been extensively explored for cancer treatment by photodynamic therapy (PDT). However, overexpressed glutathione (GSH) in the tumor microenvironment can down-regulate the reactive oxygen species (ROS) level for cancer therapy. Herein, we present dendrite-shaped light-powered hematite microrobots as an effective GSH depletion agent for PDT of prostate cancer cells. These hematite microrobots can display negative phototactic motion under light irradiation and flexible actuation in a defined path controlled by an external magnetic field. Non-contact transportation of micro-sized cells can be achieved by manipulating the microrobot's motion. In addition, the biocompatible microrobots induce GSH depletion and greatly enhance PDT performance. The proposed dendrite-shaped hematite microrobots contribute to developing dual light/magnetic field-powered micromachines for the biomedical field.


Asunto(s)
Fotoquimioterapia , Neoplasias de la Próstata , Masculino , Humanos , Glutatión , Campos Magnéticos , Neoplasias de la Próstata/tratamiento farmacológico , Dendritas , Microambiente Tumoral
3.
Small ; 18(22): e2200708, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35535477

RESUMEN

Titanium miniplates are biocompatible materials used in modern oral and maxillofacial surgery to treat facial bone fractures. However, plate removal is often required due to implant complications. Among them, a biofilm formation on an infected miniplate is associated with severe inflammation, which frequently results in implant failure. In light of this, new strategies to control or treat oral bacterial biofilm are of high interest. Herein, the authors exploit the ability of nanorobots against multispecies bacterial biofilm grown onto facial commercial titanium miniplate implants to simulate pathogenic conditions of the oral microenvironment. The strategy is based on the use of light-driven self-propelled tubular black-TiO2 /Ag nanorobots, that unlike traditional ones, exhibit an extended absorption and motion actuation from UV to the visible-light range. The motion analysis is performed separately over UV, blue, and green light irradiation and shows different motion behaviors, including a fast rotational motion that decreases with increasing wavelengths. The biomass reduction is monitored by evaluating LIVE/DEAD fluorescent and digital microscope images of bacterial biofilm treated with the nanorobots under motion/no-motion conditions. The current study and the obtained results can bring significant improvements for effective therapy of infected metallic miniplates by biofilm.


Asunto(s)
Biopelículas , Titanio , Bacterias , Prótesis e Implantes
4.
Small Methods ; 5(10): e2100511, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34927946

RESUMEN

Miniaturized energy storage devices are essential to power the growing number and variety of microelectronic technologies. Here, a concept of self-propelled microscale energy storage elements that can move, reach, and power electronic circuits is reported. Microrockets consisting of a nickel sulfide (NiS) outer layer and a Pt inner layer are prepared by template-assisted electrodeposition, and designed to store energy through NiS-mediated redox reactions and propel via the Pt-catalyzed decomposition of H2 O2 fuel. Scanning electrochemical microscopy allows visualizing and studying the energy storage ability of a single microrocket, revealing its pseudocapacitive nature. This proves the great potential of such technique in the field of micro/nanomotors. On-demand delivery of energy storage units to electronic circuits has been demonstrated by releasing microrockets on an interdigitated array electrode as an example of electronic circuit. Owing to their self-propulsion ability, they reach the active area of the electrode and, in principle, power its functions. These autonomously moving energy storage devices will be employed for next-generation electronics to store and deliver energy in previously inaccessible locations.

5.
Case Rep Ophthalmol ; 12(2): 492-496, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34248580

RESUMEN

We report long-term alterations of anterior corneal stroma after excimer laser surface ablation for a high astigmatism. The patient claimed progressive visual loss in his right eye (RE) during the last 3 years after bilateral laser-assisted subepithelial keratectomy (LASEK) surgery. His examination comprised visual acuity (UDVA and CDVA), slit-lamp examination, corneal topography and tomography, AS-OCT, and confocal microscopy. The UDVA was 0.1 in his RE and 1.0 in the left eye. The CDVA in the RE was 0.8. The slit-lamp examination showed a stromal lesion in the inferior paracentral corneal zone, with multiple vertical tissue bridges and severe thinning. Corneal topography and tomography showed central flattening with inferior steepening and severe alteration in elevation maps. AS-OCT showed void areas in the anterior stroma with thinning of the underlying tissue, and confocal images were not specific. In this case, progressive corneal steepening and thinning that manifest topographically as inferior ectasia occurred in correspondence to the singular stromal alterations after LASEK.

6.
J Phys Condens Matter ; 33(30)2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-33794513

RESUMEN

Gas sensor technology is widely utilized in various areas ranging from home security, environment and air pollution, to industrial production. It also hold great promise in non-invasive exhaled breath detection and an essential device in future internet of things. The past decade has witnessed giant advance in both fundamental research and industrial development of gas sensors, yet current efforts are being explored to achieve better selectivity, higher sensitivity and lower power consumption. The sensing layer in gas sensors have attracted dominant attention in the past research. In addition to the conventional metal oxide semiconductors, emerging nanocomposites and graphene-like two-dimensional materials also have drawn considerable research interest. This inspires us to organize this comprehensive 2020 gas sensing materials roadmap to discuss the current status, state-of-the-art progress, and present and future challenges in various materials that is potentially useful for gas sensors.

7.
RSC Adv ; 9(52): 30182-30194, 2019 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-35530201

RESUMEN

A novel hybrid photoactive material based on graphene foam (G) coupled with porphyrin-based polymers (Porph rings) was formulated by using a time-saving procedure to remove nickel from the final device. Specifically, Porph rings were spin coated onto the G platform with the double function of a visible-light photocatalyst and protective agent during nickel etching. The characterization of G-Porph rings was assessed by Scanning Electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL). The novel material showed photocatalytic ability in degrading different classes of pollutants such as the herbicide 2,4 dichlorophenoxyacetic acid (2,4-D), polyethylene glycol (PEG) as an ingredient of care and health products, and also the methylene blue (MB) dye. UV-Vis spectroscopy, total organic carbon (TOC) and soft mass spectrometry techniques were used to monitor the photocatalytic process. The best performance in terms of photocatalytic efficiency was exhibited versus PEG and MB degradation. Furthermore, to determine the individual contribution of Reactive Oxygen Species (ROS) produced, free radical and hole scavenging tests were also carried out. Finally, a detailed map of the photocatalytic degradation mechanisms was proposed, reporting also the calculation of Porph rings' Highest Occupied Molecular Orbital (HOMO) and Lowest Occupied Molecular Orbital (LUMO) energy level values.

8.
Int J Ophthalmol ; 11(4): 612-615, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29675379

RESUMEN

AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens (IOL) implantation in uncommon cases. METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy (PRK) enhancement. The mean outcome measures were refraction, uncorretted visual acuity (UCVA), best corrected visual acuity (BCVA) and corneal transparency and follow up ranged from 1 to 8y. RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent (SE) was -0.56±3 D ranging from -4.62 to +2.25 D in high myopic patients, instead it was -1±1.73 D ranging from -3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of -3.75±0 ranging from -3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from -0.50 to +1.50 in the myopic group, and it was -0.50±0.57 ranging from -1.25 to +0.50 in astigmatic patients, with a mean cylinder of -0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered values remained stable also at the end line evaluation. CONCLUSION: The excimer laser treatment of residual refractive errors after cataract surgery with IOL implantation in abnormal eyes resulted in satisfactory and stable visual outcome with good safety and efficacy.

9.
Int J Ophthalmol ; 10(7): 1168-1170, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28730124

RESUMEN

This study aims to evaluate and to compare three different approaches of cataract surgery to patients with previous radial keratotomy (RK), and to analyze the mechanical properties of the cornea after cataract surgery. Three groups of patients, each one including 8 eyes of patients with 16 RK incisions. The first group includes eyes with the first cataract incision superiorly, the second group in the temporal area, the third group in temporal area and a precautionary stabilizing suture across the RK incision adjacent to the main tunnel. In the first group intraoperative dehiscence occurred in three eyes (37.5%): it required immediate application of a suture. In the second group dehiscence occurred intraoperatively in two radial scars (20%): it required immediate application of a suture. In the third group, no intraoperative dehiscences were observed. The stabilizing suture of the RK incision works safer, with a lower risk of dehiscences and less post-operative astigmatism.

10.
Int J Surg ; 12 Suppl 1: S132-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24862674

RESUMEN

Since Kocher and Billroth refined an acceptable technique, the thyroidectomy has become one of the most frequent procedures in endocrine surgery and bilateral total thyroidectomy is performed in the majority of thyroid diseases. This work evaluated the use of the Harmonic(®) FOCUS and traditional suture ligation (knot and tie) technique in a prospective, randomized study of open thyroidectomy. Eighty two patients were randomized and divided into two similarly sized groups: the Harmonic(®) FOCUS group (F group) and traditional group (T group). The use of the harmonic FOCUS shows some statistically significant advantages limited to a few intraoperative parameters: surgical time and volume of blood loss. The surgical time was significantly shorter in F group than in the T group (105 ± 27 min vs 143 ± 32 respectively; p < 0.05). Intraoperative volume blood loss was significantly more in the T group than in the F group (36 ± 23 ml vs. 24 ± 18; p < 0.05). The postoperative parameters (volume of drainage fluid, serum calcium at 12 and 48 h, hypocalcemia, wound complication, RLN palsy, postoperative pain and length of hospital stay) showed no statistical difference. The Harmonic Focus may provide a cost-effective option only in high volume centers where reducing operative time may balance the number of daily procedures.


Asunto(s)
Bocio Nodular/cirugía , Hemostasis Quirúrgica/efectos adversos , Técnicas de Sutura/efectos adversos , Tiroidectomía/efectos adversos , Procedimientos Quirúrgicos Ultrasónicos/efectos adversos , Adulto , Pérdida de Sangre Quirúrgica/prevención & control , Análisis Costo-Beneficio , Femenino , Hemostasis Quirúrgica/métodos , Humanos , Hipocalcemia/etiología , Tiempo de Internación/estadística & datos numéricos , Ligadura , Masculino , Persona de Mediana Edad , Tempo Operativo , Dolor Postoperatorio , Periodo Posoperatorio , Estudios Prospectivos , Seguridad , Suturas/efectos adversos , Tiroidectomía/métodos , Resultado del Tratamiento , Procedimientos Quirúrgicos Ultrasónicos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA