Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
EuroIntervention ; 17(16): 1289-1297, 2022 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-34673502

RESUMEN

BACKGROUND: The mean age of transcatheter aortic valve implantation (TAVI) patients is steadily decreasing. AIMS: The aim of the study was to describe the characteristics, the indications for and the outcomes of TAVI in patients <70 years old. METHODS: All patients undergoing TAVI (n=8,626) from the 18 participating centres between January 2007 and June 2020 were stratified by age (70). For patients <70, the indications for TAVI were extracted from Heart Team discussions and the baseline characteristics and mortality were compared between the two groups. RESULTS: Overall, 640 (7.4%) patients were <70 (9.1% during 2018-2020, p<0.001); the mean age was 65.0±2.3 years. The younger patients were more often male, with bicuspid valves or needing valve-in-valve procedures. They had a higher prevalence of lung disease and diabetes. In 80.7% of cases, the Heart Team estimated an increased surgical risk and TAVI was selected, reflected by an STS score >4% in 20.4%. Five-year mortality was similar (29.4 vs 29.8%, HR 0.95, p=0.432) in the <70 and >70 groups. In the <70 group, mortality was higher for those referred for TAVI due to an increased surgical risk compared to those referred for other reasons (31.6 vs 24.5%, HR 1.23, p=0.021). Mortality was similar regardless of the STS stratum in patients judged by the Heart Team to be at increased surgical risk (32.6 vs 30.4%, HR 0.98, p=0.715). CONCLUSIONS: Use of TAVI in patients <70 is becoming more frequent. The main reason for choosing TAVI is due to an increased surgical risk not adequately represented by the STS score. The outcomes for these patients are similar to those for older TAVI patients. Dedicated trials of TAVI/SAVR in younger patients are needed to guide decisions concerning expansion of TAVI indications. ((ClinicalTrials.gov: NCT04031274).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Interact Cardiovasc Thorac Surg ; 34(6): 982-989, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34942005

RESUMEN

OBJECTIVES: Obesity may increase the risk of vascular complications in transfemoral (TF) transcatheter aortic valve replacement (TAVR) procedures. The transcarotid (TC) approach has recently emerged as an alternative access in TAVR. We sought to compare vascular complications and early clinical outcomes in obese patients undergoing TAVR either by TF or TC vascular access. METHODS: Multicentre registry including obese patients undergoing TF- or TC-TAVR in 15 tertiary centres. All patients received newer-generation transcatheter heart valves. For patients exhibiting unfavourable ileo-femoral anatomic characteristics, the TC approach was favoured in 3 centres with experience with it. A propensity score analysis was performed for overcoming unbalanced baseline covariates. The primary end point was the occurrence of in-hospital vascular complications (Valve Academic Research Consortium-2 criteria). RESULTS: A total of 539 patients were included, 454 (84.2%) and 85 (15.8%) had a TF and TC access, respectively. In the propensity-adjusted cohort (TF: 442 patients; TC: 85 patients), both baseline and procedural valve-related characteristics were well-balanced between groups. A significant decrease in vascular complications was observed in the TC group (3.5% vs 12% in the TF group, odds ratio: 0.26, 95% CI: 0.07-0.95, P = 0.037). There were no statistically significant differences between groups regarding in-hospital mortality (TC: 2.8%, TF: 1.5%), stroke (TC: 1.2%, TF: 0.4%) and life-threatening/major bleeding events (TC: 2.8%, TF: 3.8%). CONCLUSIONS: In patients with obesity undergoing TAVR with newer-generation devices, the TC access was associated with a lower rate of vascular complications. Larger randomized studies are warranted to further assess the better approach for TAVR in obese patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Humanos , Obesidad/complicaciones , Obesidad/diagnóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
3.
EuroIntervention ; 17(10): 835-847, 2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34796879

RESUMEN

Transcatheter aortic valve implantation (TAVI) has revolutionised the treatment of severe, symptomatic aortic stenosis and it is now a proven and effective alternative to surgery for patients regardless of preoperative risk stratification. Nevertheless, the consequent expansion towards younger patients with longer life expectancy focuses attention on long-term considerations. In particular, although the prevalence of coronary artery disease has been shown to decrease with the lowering of estimated risk stratification, the chance of requirement of future coronary interventions after TAVI increases dramatically as a function of patients' life expectancy. To date, however, only a few studies have investigated the feasibility and reproducibility of coronary artery cannulation after TAVI. Different conditions related mainly to aortic root anatomy and specific transcatheter aortic valve (TAV) designs and deployment have been associated with impaired coronary access after TAVI. In the present review, we will examine the conditions that may make coronary access after TAVI more challenging or even impossible.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cateterismo , Vasos Coronarios , Humanos , Reproducibilidad de los Resultados , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
Eur Heart J Suppl ; 22(Suppl L): L140-L145, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33239989

RESUMEN

Aortic stenosis (AS) is one of the most common valvular diseases in developed countries. Transcatheter aortic valve implantation (TAVI) has emerged as alternative to medical treatment or surgical aortic valve replacement (SAVR) in all symptomatic patients with severe AS. In 2002, Cribier performed the first human TAVI through a trans-septal approach in a 57-year-old man with severe AS. Since then, several trials have compared TAVI vs. SAVR over the years. Today, it is superior in terms of mortality to medical therapy in extreme-risk patients, non-inferior or superior to surgery in high-risk patients, and non-inferior to surgery and even superior when transfemoral access is possible in intermediate-risk patients. Interesting results emerged from the latest multicentre trials involving patients with severe AS who were at low risk for death from surgery, demonstrating that this therapy will be offered to younger people in the next future.

5.
Expert Rev Cardiovasc Ther ; 17(12): 863-872, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31829050

RESUMEN

Introduction: Transcatheter aortic valve implantation therapy is spreading rapidly, representing the standard of care in inoperable and high-risk patients, and a valid alternative in intermediate- and low-risk patients with severe symptomatic aortic stenosis. In this subset, the development and validation of noninvasive, quantitative, in vivo imaging modality, to monitor possible valve dysfunction is mandatory, in order to plan timely therapeutic interventions before the onset of symptoms.Areas covered: The implantation of transcatheter heart valves (THV) is increasing rapidly. As a consequence, THV dysfunction will become a major cause of cardiovascular morbidity after TAVI. Emergency repeat aortic valve replacement surgery is associated with a high rate of mortality compared with elective repeat surgery. In this context, early detection of THV dysfunction is therefore highly desirable. The review aims to examine the different diagnostic method to early detect THV dysfunction.Expert opinion: Most promising innovations in the diagnosis of early detection of THV dysfunction are evaluated, and the future outlook is explored. Waiting for upcoming evidence about the utility of CT, CMR, and PET on early detection of THV dysfunction, tailoring echocardiogram follow-up based on patients' characteristics is the desirable approach.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Diagnóstico Precoz , Ecocardiografía , Prótesis Valvulares Cardíacas , Humanos , Diseño de Prótesis , Resultado del Tratamiento
6.
Front Cardiovasc Med ; 6: 168, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31803761

RESUMEN

Transcatheter aortic valve-in-valve replacement has been recently reported as a less-invasive alternative to re-do surgery in patients with bioprosthetic valve failure. Although procedural success is achieved in the great majority of patients, this therapy is associated with several potential complications, and coronary occlusion is one of the most feared. This is a rare event, but it is associated with an extremely poor prognosis. In this review, the mechanisms, the identification of patients at high risk, the primary prevention strategies, and treatment of coronary occlusion will be discussed.

7.
J Am Heart Assoc ; 7(15): e008440, 2018 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-30371244

RESUMEN

Background Long-term data on durability of currently available transcatheter heart valves are sparse. We sought to assess the incidence of long-term (8-year) structural valve dysfunction and bioprosthetic valve failure in a cohort of patients with transcatheter aortic valve replacement ( TAVR ) who reached at least 5-year follow-up. Methods and Results Consecutive patients with at least 5-year follow-up available undergoing TAVR from June 4, 2007 to March 30, 2012 were included. Structural valve dysfunction and bioprosthetic valve failure were defined according to newly standardized European Association of Percutaneous Cardiovascular Interventions/ European Society of Cardiology/European Association for Cardio-Thoracic Surgery criteria and reported as cumulative incidence function to account for the competing risk of death. A total of 288 consecutive patients with a mean age of 80.7±5.3 years and with a mean Society of Thoracic Surgery mortality score of 8.1±5.1% were analyzed. Survival rate at 8 years was 29.8%. Mean pressure gradients decreased from 53.3±15.9 mm Hg (pre- TAVR ) to 10.5±4.5 mm Hg (in-hospital post- TAVR ) ( P<0.001). There was a small, not significant, increase in the transaortic gradient throughout follow-up. Bioprosthetic valve failure was observed in a total of 11 patients (8-year cumulative incidence function: 4.51%; 95% confidence interval , 1.95%-8.76%). Severe and moderate structural valve dysfunctions were reported in 7 patients (8-year cumulative incidence function: 2.39%; 95% confidence interval, 0.77%-5.71%) and 13 patients (8-year cumulative incidence function: 5.87%; 95% confidence interval , 3.06%-9.96%), respectively. Aortic valve reintervention (redo TAVR ) was successfully performed in 2 patients (0.7%) presenting with symptomatic severe restenosis and intraprosthetic regurgitation subsequent to endocarditis. Conclusions In an aged population of patients with symptomatic severe aortic stenosis treated with first-generation bioprostheses, TAVR was associated with a survival rate of 30% but low rates of bioprosthetic valve failure and structural valve dysfunction at 8 years.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Femenino , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Recurrencia , Reoperación , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA