Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Nanomedicine (Lond) ; 19(3): 185-198, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38275177

RESUMEN

Aim: To find a practical biomonitoring method for researchers exposed to nanoparticles causing oxidative stress. Methods: In a continuation of a study in 2016-2018, biological samples (plasma, urine and exhaled breath condensate [EBC]) were collected in 2019-2020 from 43 researchers (13.8 ± 3.0 years of exposure) and 45 controls. Antioxidant status was assessed using glutathione (GSH) and ferric-reducing antioxidant power, while oxidative stress was measured as thiobarbituric acid reactive substances, all using spectrophotometric methods. Researchers' personal nanoparticle exposure was monitored. Results: Plasma GSH was elevated in researchers both before and after exposure (p < 0.01); postexposure plasma GSH correlated with nanoparticle exposure, and GSH in EBC increased. Conclusion: The results suggest adaptation to chronic exposure to nanoparticles, as monitored by plasma and EBC GSH.


What is this study about? Identifying markers of oxidative stress and/or adaptation to oxidation stress could offer tools for monitoring exposure to nanoparticles in exposed researchers. In this study, we question whether these markers correlate with their personal exposure during the shift. What were the results? We found that exposure to nanoparticles correlated with the antioxidant marker glutathione, which is higher in workers who are already pre-exposed. What do the results mean? This study suggests that the researchers have adapted to nanoparticle exposure and are ready to combat oxidative stress. However, the similarity with increased markers of oxidative stress from asbestos and silica exposure, including nucleic acid oxidation, previously found in these researchers highlights the need for further research in this area to better understand and prevent potential future effects.


Asunto(s)
Antioxidantes , Nanopartículas , Estrés Oxidativo , Glutatión , Sustancias Reactivas al Ácido Tiobarbitúrico , Pruebas Respiratorias/métodos , Biomarcadores/metabolismo
2.
Cent Eur J Public Health ; 30(1): 32-36, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35421296

RESUMEN

OBJECTIVES: Isocyanates are known to induce occupational diseases. The aim of this work was to assess the health effects of exposure to isocyanates and to test the sensitivity of selected parameters for early detection of isocyanate-related allergic diseases. METHODS: In total, 35 employees from one factory were tested: 26 workers exposed to isocyanates (exposed group) and nine office workers (control group). All subjects filled in a questionnaire regarding possible health problems. Fractional exhaled nitric oxide (FeNO) and spirometry were measured for each subject at the same time during two consecutive working days. A urine sample was taken for a biological exposure test (BET). RESULTS: No significant difference was found between the exposed and control groups for spirometry parameters and FeNO. However, in the exposed group, FeNO was highly elevated (> 50 ppb) in five subjects (all reporting health problems at the workplace, all with normal spirometry and non-smokers). The BET revealed a significant difference (p < 0.001) between the exposed and control groups for 4,4´-methylenediphenyl diamine (MDA) in the urine. CONCLUSIONS: Our examination showed the usefulness of the BET in monitoring of workplace exposure to isocyanates and the importance of FeNO in monitoring of allergic inflammation of airways in non-smoking employees with normal spirometry.


Asunto(s)
Enfermedades Profesionales , Exposición Profesional , Automóviles , Humanos , Isocianatos/análisis , Isocianatos/orina , Exposición Profesional/efectos adversos , Lugar de Trabajo
3.
Int J Mol Sci ; 21(7)2020 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-32244494

RESUMEN

The risk of exposure to nanoparticles (NPs) has rapidly increased during the last decade due to the vast use of nanomaterials (NMs) in many areas of human life. Despite this fact, human biomonitoring studies focused on the effect of NP exposure on DNA alterations are still rare. Furthermore, there are virtually no epigenetic data available. In this study, we investigated global and gene-specific DNA methylation profiles in a group of 20 long-term (mean 14.5 years) exposed, nanocomposite, research workers and in 20 controls. Both groups were sampled twice/day (pre-shift and post-shift) in September 2018. We applied Infinium Methylation Assay, using the Infinium MethylationEPIC BeadChips with more than 850,000 CpG loci, for identification of the DNA methylation pattern in the studied groups. Aerosol exposure monitoring, including two nanosized fractions, was also performed as proof of acute NP exposure. The obtained array data showed significant differences in methylation between the exposed and control groups related to long-term exposure, specifically 341 CpG loci were hypomethylated and 364 hypermethylated. The most significant CpG differences were mainly detected in genes involved in lipid metabolism, the immune system, lung functions, signaling pathways, cancer development and xenobiotic detoxification. In contrast, short-term acute NP exposure was not accompanied by DNA methylation changes. In summary, long-term (years) exposure to NP is associated with DNA epigenetic alterations.


Asunto(s)
Metilación de ADN/efectos de los fármacos , Nanopartículas/efectos adversos , Exposición Profesional , Adulto , Anciano , Epigénesis Genética , Femenino , Genoma Humano , Humanos , Masculino , Persona de Mediana Edad , Nanocompuestos/efectos adversos , Adulto Joven
4.
Nanomaterials (Basel) ; 9(6)2019 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-31212919

RESUMEN

The present pilot study tested the efficiency of nanoTiO2 sunscreen to prevent the oxidative stress/inflammation caused by ultraviolet (UV) radiation using biomarkers in subjects' blood, urine, and exhaled breath condensate (EBC). In addition, the skin absorption of nanoTiO2 was studied. Six identical subjects participated in three tests: (A) nanoTiO2 sunscreen, (B) UV radiation, and (C) sunscreen + UV. The first samples were collected before the test and the second after sunscreen application and/or UV exposure. On day 4, the third samples were collected, and the sunscreen was washed off, and the fourth samples were collected on day 11. The following biomarkers were measured: malondialdehyde, 4-hydroxy-trans-hexenal, 4-hydroxy-trans-nonenal, aldehydes C6-C12, 8-iso-Prostaglandin F2α, o-tyrosine, 3-chlorotyrosine, 3-nitrotyrosine, 8-hydroxy-2-deoxyguanosine, 8-hydroxyguanosine, 5-hydroxymethyl uracil, and leukotrienes, using liquid chromatography-electrospray ionisation-tandem mass spectrometry. Titania was measured using inductively coupled plasma mass spectrometry and TiO2 nanoparticles by transmission and scanning electron microscopy. Sunscreen alone did not elevate the markers, but UV increased the biomarkers in the plasma, urine, and EBC. The sunscreen prevented skin redness, however it did not inhibit the elevation of oxidative stress/inflammatory markers. Titania and nanoTiO2 particles were found in the plasma and urine (but not in the EBC) in all sunscreen users, suggesting their skin absorption.

5.
Ind Health ; 57(6): 741-744, 2019 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-30918138

RESUMEN

The aim of this study was to ascertain whether long-term occupational exposure to nanoparticles would affect relative leukocyte telomere length (LrTL). We analysed occupational exposure to size-resolved aerosol particles, with special emphasis on nanoparticles at two workshops: i/ the production of nanocomposites containing metal oxides; ii/ laboratory to test experimental exposure of nano-CuO to rodents. Thirty five exposed researchers (age 39.5 ± 12.6 yr; exposure duration 6.0 ± 3.7 yr) and 43 controls (40.4 ± 10.5 yr) were examined. LrTL did not significantly (p=0.14) differ between the exposed researchers (0.92 ± 0.13) and controls (0.86 ± 0.15). In addition, no significant correlation (r=-0.22, p=0.22) was detected between the duration of occupational exposure and LrTL. The results remained non-significant after multiple adjustments for age, sex and smoking status. Our pilot results suggest that relative leukocyte telomere length is not affected by occupational exposure to nanoparticles.


Asunto(s)
Nanopartículas del Metal/efectos adversos , Exposición Profesional/efectos adversos , Investigadores , Acortamiento del Telómero/efectos de los fármacos , Adulto , Contaminantes Ocupacionales del Aire/efectos adversos , República Checa/epidemiología , Femenino , Humanos , Leucocitos , Masculino , Persona de Mediana Edad , Óxidos
6.
Nanomaterials (Basel) ; 8(9)2018 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-30223600

RESUMEN

Thousands of researchers and workers worldwide are employed in nanocomposites manufacturing, yet little is known about their respiratory health. Aerosol exposures were characterized using real time and integrated instruments. Aerosol mass concentration ranged from 0.120 mg/m³ to 1.840 mg/m³ during nanocomposite machining processes; median particle number concentration ranged from 4.8 × 104 to 5.4 × 105 particles/cm³. The proportion of nanoparticles varied by process from 40 to 95%. Twenty employees, working in nanocomposite materials research were examined pre-shift and post-shift using spirometry and fractional exhaled nitric oxide (FeNO) in parallel with 21 controls. Pro-inflammatory leukotrienes (LT) type B4, C4, D4, and E4; tumor necrosis factor (TNF); interleukins; and anti-inflammatory lipoxins (LXA4 and LXB4) were analyzed in their exhaled breath condensate (EBC). Chronic bronchitis was present in 20% of researchers, but not in controls. A significant decrease in forced expiratory volume in 1 s (FEV1) and FEV1/forced vital capacity (FVC) was found in researchers post-shift (p ˂ 0.05). Post-shift EBC samples were higher for TNF (p ˂ 0.001), LTB4 (p ˂ 0.001), and LTE4 (p ˂ 0.01) compared with controls. Nanocomposites production was associated with LTB4 (p ˂ 0.001), LTE4 (p ˂ 0.05), and TNF (p ˂ 0.001), in addition to pre-shift LTD4 and LXB4 (both p ˂ 0.05). Spirometry documented minor, but significant, post-shift lung impairment. TNF and LTB4 were the most robust markers of biological effects. Proper ventilation and respiratory protection are required during nanocomposites processing.

7.
Nanotoxicology ; 11(1): 52-63, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27855548

RESUMEN

Nanoscale titanium dioxide (nanoTiO2) is a commercially important nanomaterial. Animal studies have documented lung injury and inflammation, oxidative stress, cytotoxicity and genotoxicity. Yet, human health data are scarce and quantitative risk assessments and biomonitoring of exposure are lacking. NanoTiO2 is classified by IARC as a group 2B, possible human carcinogen. In our earlier studies we documented an increase in markers of inflammation, as well as DNA and protein oxidative damage, in exhaled breath condensate (EBC) of workers exposed nanoTiO2. This study focuses on biomarkers of lipid oxidation. Several established lipid oxidative markers (malondialdehyde, 4-hydroxy-trans-hexenal, 4-hydroxy-trans-nonenal, 8-isoProstaglandin F2α and aldehydes C6-C12) were studied in EBC and urine of 34 workers and 45 comparable controls. The median particle number concentration in the production line ranged from 1.98 × 104 to 2.32 × 104 particles/cm3 with ∼80% of the particles <100 nm in diameter. Mass concentration varied between 0.40 and 0.65 mg/m3. All 11 markers of lipid oxidation were elevated in production workers relative to the controls (p < 0.001). A significant dose-dependent association was found between exposure to TiO2 and markers of lipid oxidation in the EBC. These markers were not elevated in the urine samples. Lipid oxidation in the EBC of workers exposed to (nano)TiO2 complements our earlier findings on DNA and protein damage. These results are consistent with the oxidative stress hypothesis and suggest lung injury at the molecular level. Further studies should focus on clinical markers of potential disease progression. EBC has reemerged as a sensitive technique for noninvasive monitoring of workers exposed to engineered nanoparticles.


Asunto(s)
Peroxidación de Lípido/efectos de los fármacos , Nanopartículas/análisis , Exposición Profesional/análisis , Estrés Oxidativo/efectos de los fármacos , Titanio/análisis , Biomarcadores/análisis , Biomarcadores/orina , Pruebas Respiratorias , Industria Química , Daño del ADN , Dinoprost/análogos & derivados , Dinoprost/análisis , Dinoprost/orina , Monitoreo del Ambiente/métodos , Humanos , Metabolismo de los Lípidos , Masculino , Malondialdehído/análisis , Malondialdehído/orina , Nanopartículas/toxicidad , Exposición Profesional/efectos adversos , Oxidación-Reducción , Espectrofotometría Atómica , Titanio/toxicidad
8.
J Breath Res ; 10(3): 036004, 2016 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-27356965

RESUMEN

Human health data regarding exposure to nanoparticles are extremely scarce and biomonitoring of exposure is lacking in spite of rodent pathological experimental data. Potential markers of the health-effects of engineered nanoparticles were examined in 30 workers exposed to TiO2 aerosol, 22 office employees of the same plant, and 45 unexposed controls. Leukotrienes (LT) B4, C4, E4, and D4 were analysed in the exhaled breath condensate (EBC) and urine via liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Fractional exhaled nitric oxide (FeNO) and spirometry was also measured. The median particle number concentration of the aerosol in the production ranged from 1.98 × 10(4) to 2.32 × 10(4) particles cm(-3); about 80% of the particles were <100 nm in diameter. Median total mass concentration varied between 0.4 and 0.65 mg m(-3). All LT levels in workers' EBC were elevated relative to the controls (p < 0.01). LTs in the EBC sample were correlated with titanium levels. Urinary LTs were not elevated in the workers and office employees. Office workers had higher LTB4 in EBC (p < 0.05), and higher levels of FeNO (p < 0.01). FeNO was higher in office employees with allergic diseases and was negatively correlated with smoking (p < 0.01). In spirometry significant impairment in the workers was seen only for %VCIN and %PEF (both p < 0.01). Multiple regression analysis confirmed a significant association between production of TiO2 and all cysteinyl LTs in EBC (p < 0.01) and impaired %VCIN and %PEF (both p < 0.01). LTB4 was also associated with smoking (p < 0.01). LT levels complemented our earlier findings of DNA, protein, and lipid damage in the EBC of workers with nanoTiO2 exposures. Cysteinyl LTs in EBC analysis suggest inflammation and potential fibrotic changes in the lungs; they may be helpful for monitoring the biological effect of (nano)TiO2 on workers. Spirometry was not sensitive enough.


Asunto(s)
Pruebas Respiratorias/métodos , Espiración , Leucotrienos/análisis , Nanopartículas/efectos adversos , Óxido Nítrico/análisis , Exposición Profesional/análisis , Titanio/efectos adversos , Adulto , Aerosoles/análisis , Biomarcadores/análisis , Estudios de Casos y Controles , Humanos , Concentración de Iones de Hidrógeno , Leucotrienos/orina , Análisis de Regresión , Pruebas de Función Respiratoria , Espectrometría de Masas en Tándem , Lugar de Trabajo
9.
J Breath Res ; 10(1): 016004, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26828137

RESUMEN

Markers of oxidative stress and inflammation were analysed in the exhaled breath condensate (EBC) and urine samples of 14 workers (mean age 43 ± 7 years) exposed to iron oxide aerosol for an average of 10 ± 4 years and 14 controls (mean age 39 ± 4 years) by liquid chromatography-electrospray ionization-mass spectrometry/mass spectrometry (LC-ESI-MS/MS) after solid-phase extraction. Aerosol exposure in the workplace was measured by particle size spectrometers, a scanning mobility particle sizer (SMPS) and an aerodynamic particle sizer (APS), and by aerosol concentration monitors, P-TRAK and DustTRAK DRX. Total aerosol concentrations in workplace locations varied greatly in both time and space. The median mass concentration was 0.083 mg m(-3) (IQR 0.063-0.133 mg m(-3)) and the median particle concentration was 66 800 particles cm(-3) (IQR 16,900-86,900 particles cm(-3)). In addition, more than 80% of particles were smaller than 100 nm in diameter. Markers of oxidative stress, malondialdehyde (MDA), 4-hydroxy-trans-hexenale (HHE), 4-hydroxy-trans-nonenale (HNE), 8-isoProstaglandin F2α (8-isoprostane) and aldehydes C6-C12, in addition to markers of nucleic acid oxidation, including 8-hydroxy-2-deoxyguanosine (8-OHdG), 8-hydroxyguanosine (8-OHG), 5-hydroxymethyl uracil (5-OHMeU), and of proteins, such as o-tyrosine (o-Tyr), 3-chlorotyrosine (3-ClTyr), and 3-nitrotyrosine (3-NOTyr) were analysed in EBC and urine by LC-ESI-MS/MS. Almost all markers of lipid, nucleic acid and protein oxidation were elevated in the EBC of workers comparing with control subjects. Elevated markers were MDA, HNE, HHE, C6-C10, 8-isoprostane, 8-OHdG, 8-OHG, 5-OHMeU, 3-ClTyr, 3-NOTyr, o-Tyr (all p < 0.001), and C11 (p < 0.05). Only aldehyde C12 and the pH of samples did not differ between groups. Markers in urine were not elevated. These findings suggest the adverse effects of nano iron oxide aerosol exposure and support the utility of oxidative stress biomarkers in EBC. The analysis of urine oxidative stress biomarkers does not support the presence of systemic oxidative stress in iron oxide pigment production workers.


Asunto(s)
Compuestos Férricos/síntesis química , Nanopartículas/toxicidad , Estrés Oxidativo/fisiología , Adulto , Aldehídos/análisis , Biomarcadores/análisis , Pruebas Respiratorias , Dinoprost/análogos & derivados , Dinoprost/análisis , Guanosina/análogos & derivados , Guanosina/análisis , Humanos , Masculino , Malondialdehído/análisis , Persona de Mediana Edad , Estrés Oxidativo/efectos de los fármacos , Espectrometría de Masas en Tándem , Tirosina/análogos & derivados , Tirosina/análisis
10.
J Breath Res ; 9(3): 036008, 2015 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-26172946

RESUMEN

The health effects of engineered nanoparticles in humans are not well-understood; however experimental data support the theory of oxidative stress promoting fibrogenesis and carcinogenicity. The aim of this study was to detect TiO2 particles in exhaled breath condensate (EBC) and urine samples to ascertain their presence and potential persistence and excretion in urine.EBC and urine samples were collected from 20 workers exposed to TiO2 aerosol; among them, 16 had a higher risk level of exposure (production workers) and four had medium risk level (research workers); in addition to 20 controls. Titanium levels in EBC and urine were analysed using the inductively coupled plasma mass spectrometry (ICP-MS) method. A Raman microspectroscopic analysis was performed in EBC and urine to identify the phase composition of TiO2 particles observed. Aerosol exposure in the workplaces was measured using SMPS and APS spectrometers and P-TRAK and DustTRAK DRX monitors.The median concentration of TiO2 aerosol was 1.98 × 10(4) particles cm(-3), the interquartile range (IQR) was 1.50 × 10(4) - 3.01 × 10(4) particles cm(-3) and the median mass concentration was 0.65 mg m(-3) (IQR 0.46-.0.83 mg m(-3)); 70-82% of the particles were smaller than 100 nm in diameter. In any part of the plant, the median TiO2 air concentration did not exceed the national airborne exposure limit of 10 mg m(-3) for inert dust. Particles of rutile and/or anatase were found in the EBC of exposed workers in 8/20 (40%) of the pre-shift and 14/20 (70%) of the post-shift samples. In the urine of workers, TiO2 particles were detected in 2/20 post-shift urine samples only. The mean concentration of titanium in the EBC in production workers was 24.1 ± 1.8 µg/l. In the research workers the values were below the limit of quantitation; LOQ = 4.0 ± 0.2 µg/l), as well as in the controls. In the urine samples of all of the subjects, titanium was under the limit of detection (LOD = 1.2 µg/l). Raman microanalysis of EBC in the workers confirmed the presence of TiO2 anatase and/or rutile crystal phases in the pre-shift samples and their persistence from previous shifts in the workers.


Asunto(s)
Exposición Profesional , Titanio/análisis , Adulto , Pruebas Respiratorias , Estudios Transversales , Espiración , Humanos , Masculino , Estrés Oxidativo/efectos de los fármacos , Espectrometría Raman/métodos , Titanio/orina
11.
Int J Occup Med Environ Health ; 27(2): 206-15, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24643743

RESUMEN

OBJECTIVES: To search for optimal markers in the exhaled breath condensate (EBC), plasma and urine that would reflect the activity/severity of occupational asthma (OA) after the withdrawal from the exposure to the allergen. MATERIAL AND METHODS: Markers of oxidative stress: 8-iso-prostaglandin F2α (8-isoprostane, 8-ISO), malondialdehyde (MDA), 4-hydroxy-trans-2-nonenale (HNE), cysteinyl leukotrienes (LT) and LTB4 were determined using liquid chromatography and mass spectrometry in 43 subjects with immunological OA (49.3 ± 11.8 years), removed from the exposure to the sensitizing agent 10.5 ± 6.5 years ago; and in 20 healthy subjects (49.0 ± 14.9 years). EBC was harvested both before and after the methacholine challenge test. In parallel, identical markers were collected in plasma and urine. The results were analyzed together with forced expiratory volume in one second (FEV1), blood eosinophils, immunoglobulin E (IgE) and eosinophilic cationic protein (ECP) and statistically evaluated (Spearman rank correlation rS, two- or one-sample t tests and alternatively Kruskal Wallis or pair Wilcoxon tests). RESULTS: Several parameters of lung functions were lower in the patients (FEV1% predicted, MEF25% and MEF50%, Rtot%, p < 0.001). Shorter time interval since the removal from the allergen exposure correlated with higher ECP (rS = 0.375) and lower FEV1%, MEF25% and MEF50% after methacholine challenge (rS = -0.404, -0.425 and -0.532, respectively). In the patients, IgE (p < 0.001) and ECP (p = 0.009) was increased compared to controls. In EBC, 8-ISO and cysteinyl LTs were elevated in the asthmatics initially and after the challenge. Initial 8-ISO in plasma correlated negatively with FEV1 (rS = -0.409) and with methacholine PD20 (rS = -0.474). 8-ISO in plasma after the challenge correlated with IgE (rS = 0.396). CONCLUSIONS: The improvement in OA is very slow and objective impairments persist years after removal from the exposure. Cysteinyl LTs and 8-ISO in EBC and 8-ISO in plasma might enrich the spectrum of useful objective tests for the follow-up of OA.


Asunto(s)
Asma Ocupacional/metabolismo , Cisteína/análisis , Dinoprost/análogos & derivados , Leucotrienos/análisis , Adulto , Asma Ocupacional/fisiopatología , Biomarcadores/análisis , Biomarcadores/metabolismo , Pruebas Respiratorias , Estudios de Casos y Controles , Dinoprost/análisis , Dinoprost/sangre , Proteína Catiónica del Eosinófilo/sangre , Femenino , Estudios de Seguimiento , Volumen Espiratorio Forzado , Humanos , Masculino , Flujo Espiratorio Medio Máximo , Persona de Mediana Edad , Índice de Severidad de la Enfermedad
12.
Ind Health ; 50(4): 299-306, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22785421

RESUMEN

Leukotrienes (LTs) are involved in the pathogenesis of lung fibrosis and were increased in exhaled breath condensate (EBC) of the patients with pneumoconiosis. However the possible influence of extra-pulmonary disorders on the EBC markers is not known. Therefore in parallel with EBC, LTs' levels in the plasma and urine were measured in patients with pneumoconiosis (45 × asbestos exposure, 37 × silica exposure) and in 27 controls. Individual LTs B4, C4, D4 and E4 were measured by liquid chromatography - electrospray ionization - tandem mass spectrometry (LC-ESI-MS/MS). In EBC, LT D4 and LT E4 were increased in both groups of patients (p<0.001 and p<0.05), comparing with the controls. Both LT B4 and cysteinyl LTs were elevated in asbestos-exposed subjects (p<0.05). Asbestosis with more severe radiological signs (s1/s2-t3/u2) and lung functions impairment has shown higher cysteinyl LTs and LT C4 in the EBC (p<0.05) than mild asbestosis (s1/s0-s1/s1). In addition, in the subjects with asbestosis, cysteinyl LTs in EBC correlated with TLC (-0.313, p<0.05) and TLCO/Hb (-0.307, p<0.05), and LT C4 with TLC (-0.358, p<0.05). In pneumoconioses, EBC appears the most useful from the 3 fluids studied.


Asunto(s)
Asbestosis/metabolismo , Pruebas Respiratorias , Leucotrienos/análisis , Silicosis/metabolismo , Anciano , Asbestosis/diagnóstico por imagen , Femenino , Humanos , Leucotrieno B4/análisis , Leucotrieno B4/sangre , Leucotrieno B4/orina , Leucotrieno C4/análisis , Leucotrieno C4/sangre , Leucotrieno C4/orina , Leucotrieno D4/análisis , Leucotrieno D4/sangre , Leucotrieno D4/orina , Leucotrieno E4/análisis , Leucotrieno E4/sangre , Leucotrieno E4/orina , Leucotrienos/sangre , Leucotrienos/orina , Masculino , Persona de Mediana Edad , Radiografía , Pruebas de Función Respiratoria , Índice de Severidad de la Enfermedad , Silicosis/diagnóstico por imagen
13.
Neuro Endocrinol Lett ; 32 Suppl 1: 71-6, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22167218

RESUMEN

OBJECTIVES: 2,3,7,8-tetrachloro-dibenzo-p-dioxin (TCDD) is a highly toxic persistent environmental contaminant, classified as a human carcinogen affecting any target organ. The mechanism of carcinogenesis by TCDD is unclear as TCDD shows a lack of direct genotoxicity. Experimental studies also support the role of oxidative stress in TCDD neurotoxicity and vascular dysfunction. The aim was to investigate markers of oxidative/nitrosative stress and inflammation using non-invasive methods in subjects who got ill due to severe occupational exposure to TCDD in the years 1965-1968. METHODS: In 11 TCDD-exposed patients, and 16 controls, the analysis of following oxidative products of lipids, proteins and nucleic acids in plasma, urine and exhaled breath condensate (EBC) was performed: 8-iso-prostaglandin F2α (8-isoprostane), 4-hydroxy-trans-2-nonenale (HNE), malondialdehyde (MDA), o-tyrosine (o-Tyr), 8-hydroxyguanosine (8-OHG), 8-hydroxy-2´-deoxy-guanosine (8-OHdG), 5-hydroxymethyluracil (5-OHMeU). In addition, nitric-oxide-tyrosine (NO-Tyr) and leukotriene (LT) B4, C4, D4, and E4 were detected by liquid chromatography-mass spectrometry/mass spectrometry (LC-ESI-MS/MS). TCDD was measured by HRGC/HRMS, body lipid content by densitometry. Single-photon emission spectrometry (SPECT) of the brain was performed and compared with the findings of the patients in 2008. RESULTS: Mean TCDD plasma level in 2010 was 175 ± 162 pg/g lipids (population level about 2 pg/g), total TCDD content in the body 5.16 ± 4.62 mg. Reduction of cerebral blood flow in SPECT progressed in 8 patients, finding was stable in 2 subjects, and improvement occurred in 1 patient. In the EBC, 10 from 12 markers (all except LT D4 and LT E4), were significantly increased in the patients (p<0.05). In the urine, 7 markers were significantly higher than in the controls (p<0.05): 8-isoprostane, MDA, HNE, LT C4, LT E4, o-Tyr and NO-Tyr. In plasma, only NO-Tyr and 8-OHG were elevated (p<0.05). CONCLUSION: NO-Tyr was increased in all matrices in dioxin-exposed patients. EBC is not limited to lung disorders as the markers of oxidative stress and inflammation were elevated in EBC of patients with normal lung functions. TCDD-induced oxidative stress and inflammation markers can be detected non-invasively in the EBC and urine in the follow-up of the highly-exposed patients. Their prognostic value, however, needs to be elucidated.


Asunto(s)
Biomarcadores/análisis , Estrés Oxidativo/fisiología , Dibenzodioxinas Policloradas/análogos & derivados , Especies de Nitrógeno Reactivo/análisis , Especies Reactivas de Oxígeno/análisis , Anciano , Biomarcadores/sangre , Biomarcadores/orina , Análisis Químico de la Sangre/métodos , Estudios de Casos y Controles , Industria Química , Femenino , Herbicidas/análisis , Herbicidas/sangre , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/análisis , Concentración Osmolar , Dibenzodioxinas Policloradas/análisis , Dibenzodioxinas Policloradas/sangre , Especies de Nitrógeno Reactivo/sangre , Especies de Nitrógeno Reactivo/metabolismo , Especies de Nitrógeno Reactivo/orina , Especies Reactivas de Oxígeno/sangre , Especies Reactivas de Oxígeno/metabolismo , Especies Reactivas de Oxígeno/orina , Regulación hacia Arriba , Urinálisis/métodos
14.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(24): 2477-86, 2009 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-19574111

RESUMEN

Sensitive assay method was developed for a parallel, rapid and precise determination of the most prominent oxidative stress biomarkers: 8-iso-prostaglandin F(2alpha), malondialdehyde and 4-hydroxynonenal. The method consisted of a pre-treatment part a solid-phase extraction, for rapid and effective isolation of biomarkers from body fluids (exhaled breath condensate, plasma and urine) and the detection method LC-ESI-MS/MS, where the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized by the following parameters: the imprecision was below 14.3%, the mean inaccuracy was determined to be lower than 13.1%. The method was tested on samples obtained from patients diagnosed with asbestosis, pleural hyalinosis or silicosis, i.e. occupational lung diseases caused by fibrogenic dusts, inducing oxidative stress in the respiratory system, and then compared to samples from healthy subjects. The difference in concentration levels of biomarkers between the two groups was perceptible in all the body fluids (the difference observed in an exhaled breath condensate was statistically most significant).


Asunto(s)
Biomarcadores/análisis , Líquidos Corporales/química , Cromatografía Líquida de Alta Presión/métodos , Enfermedades Pulmonares/etiología , Enfermedades Pulmonares/metabolismo , Estrés Oxidativo , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Anciano , Aldehídos/análisis , Aldehídos/sangre , Aldehídos/orina , Amianto/toxicidad , Biomarcadores/sangre , Biomarcadores/orina , Líquidos Corporales/metabolismo , Estudios de Casos y Controles , Dinoprost/análogos & derivados , Dinoprost/análisis , Dinoprost/sangre , Dinoprost/orina , Humanos , Enfermedades Pulmonares/sangre , Enfermedades Pulmonares/orina , Malondialdehído/análisis , Malondialdehído/sangre , Malondialdehído/orina , Persona de Mediana Edad , Dióxido de Silicio/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA