Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Anciano de 80 o más Años , Resultado del Tratamiento , Ajuste de Prótesis
2.
JAMA Cardiol ; 9(1): 25-34, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37966817

RESUMEN

Importance: Tafamidis has been shown to improve survival in patients with transthyretin amyloid cardiomyopathy (ATTR-CM) compared with placebo. However, its effect on cardiac function has not been fully characterized. Objective: To examine the effect of tafamidis on cardiac function in patients with ATTR-CM. Design, Setting, and Participants: This was an exploratory, post hoc analysis of the Tafamidis in Transthyretin Cardiomyopathy Clinical Trial (ATTR-ACT), a multicenter, international, double-blind, placebo-controlled phase 3 randomized clinical trial conducted from December 2013 to February 2018. The ATTR-ACT included 48 sites in 13 counties and enrolled patients aged 18 to 90 years with ATTR-CM. Data were analyzed from July 2018 to September 2023. Intervention: Patients were randomized to tafamidis meglumine, 80 mg or 20 mg, or placebo for 30 months. Main Outcomes and Measures: Patients were categorized based on left ventricular (LV) ejection fraction at enrollment as having heart failure with preserved ejection fraction (≥50%), mildly reduced ejection fraction (41% to 49%), or reduced ejection fraction (≤40%). Changes from baseline to month 30 in LV ejection fraction, LV stroke volume, LV global longitudinal strain, and the ratio of early mitral inflow velocity to septal and lateral early diastolic mitral annular velocity (E/e') were compared in patients receiving tafamidis, 80 mg, vs placebo. Results: A total of 441 patients were randomized in ATTR-ACT, and 436 patients had available echocardiographic data. Of 436 included patients, 393 (90.1%) were male, and the mean (SD) age was 74 (7) years. A total of 220 (50.5%), 119 (27.3%), and 97 (22.2%) had heart failure with preserved, mildly reduced, and reduced LV ejection fraction, respectively. Over 30 months, there was less pronounced worsening in 4 of the echocardiographic measures in patients receiving tafamidis, 80 mg (n = 176), vs placebo (n = 177) (least squares mean difference: LV stroke volume, 7.02 mL; 95% CI, 2.55-11.49; P = .002; LV global longitudinal strain, -1.02%; 95% CI, -1.73 to -0.31; P = .005; septal E/e', -3.11; 95% CI, -5.50 to -0.72; P = .01; lateral E/e', -2.35; 95% CI, -4.01 to -0.69; P = .006). Conclusions and Relevance: Compared with placebo, tafamidis, 80 mg, attenuated the decline of LV systolic and diastolic function over 30 months in patients with ATTR-CM. Approximately half of patients had mildly reduced or reduced LV ejection fraction at enrollment, suggesting that ATTR-CM should be considered as a possible diagnosis in patients with heart failure regardless of underlying LV ejection fraction. Trial Registration: ClinicalTrials.gov Identifier: NCT01994889.


Asunto(s)
Amiloidosis , Cardiomiopatías , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Femenino , Humanos , Masculino , Cardiomiopatías/tratamiento farmacológico , Insuficiencia Cardíaca/tratamiento farmacológico , Prealbúmina , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
3.
JACC Cardiovasc Interv ; 16(10): 1160-1172, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225286

RESUMEN

BACKGROUND: The relationship between left ventricular (LV) remodeling and clinical outcomes after treatment of severe mitral regurgitation (MR) in heart failure (HF) has not been examined. OBJECTIVES: The aim of this study was to evaluate the association between LV reverse remodeling and subsequent outcomes and assess whether transcatheter edge-to-edge repair (TEER) and residual MR are associated with LV remodeling in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: Patients with HF and severe MR who remained symptomatic on guideline-directed medical therapy (GDMT) were randomized to TEER plus GDMT or GDMT alone. Baseline and 6-month core laboratory measurements of LV end-diastolic volume index and LV end-systolic volume index were examined. Change in LV volumes from baseline to 6 months and clinical outcomes from 6 months to 2 years were evaluated using multivariable regression. RESULTS: The analytical cohort comprised 348 patients (190 treated with TEER, 158 treated with GDMT alone). A decrease in LV end-diastolic volume index at 6 months was associated with reduced cardiovascular death between 6 months and 2 years (adjusted HR: 0.90 per 10 mL/m2 decrease; 95% CI: 0.81-1.00; P = 0.04), with consistent results in both treatment groups (Pinteraction = 0.26). Directionally similar but nonsignificant relationships were present for all-cause death and HF hospitalization and between reduced LV end-systolic volume index and all outcomes. Neither treatment group nor MR severity at 30 days was associated with LV remodeling at 6 or 12 months. The treatment benefits of TEER were not significant regardless of the degree of LV remodeling at 6 months. CONCLUSIONS: In patients with HF and severe MR, LV reverse remodeling at 6 months was associated with subsequently improved 2-year outcomes but was not affected by TEER or the extent of residual MR. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] and COAPT CAS [COAPT]; NCT01626079).


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Remodelación Ventricular , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Recolección de Datos
4.
JACC Cardiovasc Imaging ; 16(1): 1-9, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36599555

RESUMEN

BACKGROUND: Current expected normal echocardiographic measures of transcatheter heart valve (THV) function were derived from pooled cohorts of the randomized trials; however, THV function by flow state before or following transcatheter aortic valve replacement (TAVR) has not been previously reported. OBJECTIVES: This study sought to assess the expected normal echocardiographic hemodynamics for the balloon-expandable THV grouped by stroke volume index (SVI). METHODS: Patients with severe aortic stenosis enrolled in PARTNER (Placement of Aortic Transcatheter Valves) 1 (high/extreme surgical risk), PARTNER 2 (intermediate surgical risk), or PARTNER 3 (low surgical risk) trials with complete core laboratory echocardiography were included. Patients were grouped by low-flow (SVILOW <35 mL/m2) and normal-flow (SVINORMAL ≥35 mL/m2). Mean gradient, effective orifice area (EOA), and Doppler velocity index (DVI) were collected at baseline and at 30 days post-TAVR. Prosthesis-patient mismatch (PPM) was both calculated and predicted from normative data, using defined criteria. RESULTS: In the entire population (N = 4,991), mean age was 81.8 years, 58% of patients were male, and 42% had low flow. Compared with patients with baseline SVINORMAL, those with SVILOW were more likely to be male; have more comorbidities; and lower left ventricular ejection fraction, mean gradient, and EOA. Post-TAVR, SVILOW increased to SVINORMAL in 17.3% and SVINORMAL decreased to SVILOW in 12.3% of patients. Using baseline SVI, follow-up EOA, mean gradient, and DVI for patients with SVILOW tended to be lower than for patients with SVINORMAL. Using the post-TAVR SVI, follow-up EOA, mean gradient, and DVI were significantly lower for patients with SVILOW than for those with SVINORMAL (P < 0.001 for all). The incidence of calculated, but not predicted, severe PPM was higher in patients with low flow than it was in patients with normal flow, suggesting pseudo-PPM in the presence of low flow. CONCLUSIONS: This study demonstrates that flow affects THV hemodynamics and both baseline and follow-up SVI should be considered when predicting THV hemodynamics prior to TAVR, as well as assessing valve function following valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Valor Predictivo de las Pruebas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Hemodinámica , Diseño de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
5.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-35789382

RESUMEN

OBJECTIVES: This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement. METHODS: Kaplan-Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated. RESULTS: A total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 ± 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 ± 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan-Meier survival rate was 88.1% (85.9-90.0%). The Kaplan-Meier event rates were 5.6% (4.3-7.2%) for thromboembolism, 4.4% (3.2-6.0%) for endocarditis, 0.2% (0.0-0.7%) for a major paravalvular leak and 3.2% (2.3-4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 ± 17.1 mmHg at baseline, to 13.1 ± 4.7 mmHg at discharge and remained stable at 12.5 ± 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery. CONCLUSIONS: The findings of a high survival rate, excellent safety, no SVD and stable haemodynamic performance and functional status through 5 years of follow-up are encouraging. Additional follow-up is needed to assess the long-term durability of this contemporary surgical bioprosthesis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia , Anciano , Animales , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Bovinos , Endocarditis/cirugía , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Tromboembolia/etiología , Resultado del Tratamiento
6.
J Am Coll Cardiol ; 74(24): 2969-2979, 2019 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-31574303

RESUMEN

BACKGROUND: In the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial among patients with heart failure (HF) and moderate-to-severe (3+) or severe (4+) secondary mitral regurgitation, patients treated with transcatheter mitral valve repair (TMVr) through leaflet approximation had reduced rates of HF hospitalization and mortality compared with guideline-directed medical therapy (GDMT) alone. OBJECTIVES: The purpose of this study was to describe the echocardiographic patient qualification process for the COAPT trial, baseline echocardiographic characteristics, changes over time, and the interaction between treatment group and echocardiographic parameters on clinical outcomes. METHODS: A novel echocardiographic algorithm was implemented for grading mitral regurgitation severity during the screening process. Standardized echocardiograms were obtained at baseline and during regular follow-up intervals through 2 years, and were analyzed by a core laboratory. RESULTS: A total of 614 patients were randomized to TMVr plus maximally tolerated GDMT or GDMT alone. Mean baseline left ventricular (LV) ejection fraction was 31.3 ± 9.3%, LV end-diastolic volume was 192.7 ± 71 ml, and effective regurgitant orifice area was 0.41 ± 0.15 cm2. The beneficial effect of TMVr compared with GDMT alone was consistent in all echocardiographic subgroups, independent of the severity of LV dysfunction, LV dilatation, pulmonary hypertension, severity of tricuspid regurgitation, or individual mitral regurgitation characteristics. The LV ejection fraction decreased and the LV volumes progressively increased in both groups during follow-up, although less after TMVr (p < 0.05). CONCLUSIONS: HF patients in the COAPT trial with 3+ or 4+ secondary mitral regurgitation, selected using strict echocardiographic criteria, benefitted from TMVr with reduced 2-year rates of death and HF hospitalization. Strict application of these echocardiographic criteria should enable the COAPT results to be translated to clinical practice. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] [COAPT]; NCT01626079).


Asunto(s)
Ecocardiografía/métodos , Insuficiencia Cardíaca/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Remodelación Ventricular , Ecocardiografía/estadística & datos numéricos , Humanos , Insuficiencia de la Válvula Mitral/etiología , Evaluación de Resultado en la Atención de Salud , Selección de Paciente
7.
J Thorac Cardiovasc Surg ; 157(5): 1773-1782.e3, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30553598

RESUMEN

OBJECTIVES: We performed a prospective, single-arm clinical trial approved under a Food and Drug Administration Investigational Device Exemption to assess safety and efficacy of Perceval, a sutureless bovine pericardial aortic valve representing the initial US experience. METHODS: From June 2013 to January 2015, 300 patients (mean age 76.7 ± 7.7 years, 54.3% men, 37.3% ≥80 years, median Society of Thoracic Surgeons Predicted Risk of Mortality 2.8%), underwent Perceval valve implantation at 18 centers across the United States. Twenty patients (6.7%) had a bicuspid aortic valve and 5 (1.7%) patients had previous aortic valve replacement. A minimally invasive approach was used in 80 (26.7%) and concomitant procedures were performed in 113 (37.8%) patients. RESULTS: Two hundred eighty-nine patients (96.3%) were successfully implanted. Operative mortality (≤30 days) was 1.3% (n = 4) (observed to expected ratio of 0.40). One-year results included all-cause mortality in 5.2% (n = 15), stroke in 1% (n = 3), and endocarditis in 1.7% (n = 5). New permanent periprocedural pacemaker rate was 10.7% (n = 30/281); 2.5% (n = 7/281) resulted from third-degree atrioventricular block. One-year valve-related reoperation was 2.1% (n = 6). At 1-year follow-up, 98% of patients were in New York Heart Association class I/II, left ventricular mass index decreased from 103.5 ± 30.1 g/m2 at discharge to 95.8 ± 27.1 g/m2 (P = .001), and 3 (1.3%) moderate paravalvular leaks were identified. Health-related quality of life score increased from 62.7 ± 21.8 before surgery to 85.5 ± 17.8 at 1 year (P < .001). CONCLUSIONS: These results confirm the safety and effectiveness of the Perceval sutureless aortic valve replacement in study patients with lower mortality than expected from a risk prediction model. Persistent hemodynamic benefit and improvement in quality of life at 1 year support the importance of this device in the management of aortic valve disease.


Asunto(s)
Válvula Aórtica/anomalías , Bioprótesis , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
8.
JACC Cardiovasc Interv ; 11(17): 1710-1718, 2018 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-30121276

RESUMEN

OBJECTIVES: The purpose of this study was to understand the effects of balloon post-dilatation on outcomes following transcatheter aortic valve replacement with the SAPIEN 3 valve. BACKGROUND: Hemodynamics and outcomes with balloon post-dilatation for the SAPIEN 3 valve have not been previously reported. METHODS: The effects of balloon post-dilatation (BPD) in 1,661 intermediate (S3i cohort) and high surgical risk (S3HR cohort) patients with aortic stenosis enrolled in the PARTNER (Placement of Aortic Transcatheter Valves) 2, SAPIEN 3 observational study on outcomes, as well as procedural complications, were assessed. RESULTS: 208 of 1,661 patients (12.5%) had BPD during the initial transcatheter aortic valve replacement. Baseline characteristics were similar except BPD had higher STS score (p < 0.001), significantly less % oversizing (p = 0.004), significantly more ≥moderate left ventricular outflow tract calcification (p = 0.005), and severe annular calcification (p = 0.006). BPD patients had no increase in permanent pacemaker, annular rupture, or valve embolization. Following transcatheter aortic valve replacement, BPD patients had significantly larger aortic valve area (1.72 ± 0.41 cm2 vs. 1.66 ± 0.37 cm2; p = 0.04) with no significant difference in prosthesis-patient mismatch (p = 0.08) or transvalvular aortic regurgitation (p = 0.65), but significantly more paravalvular regurgitation (p < 0.01). There was no significant difference in 30-day or 1-year outcomes of all-cause death (p = 0.65 to 0.76) or stroke (p = 0.28 to 0.72). However, at 1 year, there was a significantly higher incidence of minor stroke in BPD patients (p = 0.02). Adjusting for baseline differences, including calcium burden, minor strokes were no longer significantly different between the BPD and NoBPD groups (p = 0.21). CONCLUSIONS: BPD is performed more frequently in patients with lower % oversizing and greater calcium burden. BPD is not associated with procedural complications or an increase in 1-year adverse events of death, rehospitalization, or stroke.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Calcinosis/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Femenino , Humanos , Masculino , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Recuperación de la Función , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
Am Heart J ; 205: 1-11, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30134187

RESUMEN

BACKGROUND: Patients with heart failure (HF) and symptomatic secondary mitral regurgitation (SMR) have a poor prognosis, with morbidity and mortality directly correlated with MR severity. Correction of isolated SMR with surgery is not well established in this population, and medical management remains the preferred approach in most patients. The Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial was designed to determine whether transcatheter mitral valve (MV) repair with the MitraClip device is safe and effective in patients with symptomatic HF and clinically significant SMR. STUDY DESIGN: The COAPT trial is a prospective, randomized, parallel-controlled, open-label multicenter study of the MitraClip device for the treatment of moderate-to-severe (3+) or severe (4+) SMR (as verified by an independent echocardiographic core laboratory) in patients with New York Heart Association class II-IVa HF despite treatment with maximally tolerated guideline-directed medical therapy (GDMT) who have been determined by the site's local heart team as not appropriate for MV surgery. A total of 614 eligible subjects were randomized in a 1:1 ratio to MV repair with the MitraClip plus GDMT versus GDMT alone. The primary effectiveness end point is recurrent HF hospitalizations through 24 months, analyzed when the last subject completes 12-month follow-up, powered to demonstrate superiority of MitraClip therapy. The primary safety end point is a composite of device-related complications at 12 months compared to a performance goal. Follow-up is ongoing, and the principal results are expected in late 2018. CONCLUSIONS: HF patients with clinically significant SMR who continue to be symptomatic despite optimal GDMT have limited treatment options and a poor prognosis. The randomized COAPT trial was designed to determine the safety and effectiveness of transcatheter MV repair with the MitraClip in symptomatic HF patients with moderate-to-severe or severe SMR.


Asunto(s)
Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Evaluación de Resultado en la Atención de Salud , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Morbilidad/tendencias , Estudios Prospectivos , Diseño de Prótesis , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
10.
J Thorac Cardiovasc Surg ; 156(4): 1368-1377.e5, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29778342

RESUMEN

OBJECTIVES: The study objectives were to evaluate the safety, effectiveness, and hemodynamic performance of a new stented bovine pericardial aortic valve. METHODS: This trial enrolled patients with symptomatic moderate or severe aortic stenosis or chronic, severe aortic regurgitation. We assessed death, valve-related adverse events, functional recovery, and hemodynamic performance at discharge, 3 to 6 months, and 1 year, as required by the US Food and Drug Administration for regulatory approval. The primary analysis compared late linearized rates of valve-related adverse events after implantation with Food and Drug Administration-specified objective performance criteria to determine whether the adverse event rates associated with the valve are within acceptable limits. Adverse events included thromboembolism, thrombosis, all and major hemorrhage, all and major paravalvular leak, and endocarditis. RESULTS: The primary analysis included 864 patients who received an implant and 904.1 valve-years of follow-up. A total of 577 patients completed the 1-year evaluation. The primary end point was met for death, thromboembolism, thrombosis, all and major paravalvular leak, and endocarditis, but not for all and major hemorrhage. At 1 year, freedom from all death and from valve-related death was 96.4% and 99.7%, respectively. From baseline to 1 year, New York Heart Association class changed as follows: I, 10.8% to 73.7%; II, 48.9% to 22.6%; III, 38.0% to 3.5%; and IV, 2.3% to 0.2%. Effective orifice area increased from 0.9 ± 0.5 to 1.5 ± 0.4 (P < .0001), and mean aortic gradient decreased from 42.7 ± 16.5 to 12.5 ± 4.3 (P < .0001). CONCLUSIONS: This analysis of a new stented bovine pericardial aortic valve demonstrated low overall mortality and valve-related adverse events, and hemodynamic performance comparable to that of other surgical aortic valves.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Estudios Prospectivos
12.
JAMA Cardiol ; 2(11): 1197-1206, 2017 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-28973520

RESUMEN

Importance: Use of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. However, to our knowledge, the durability of these prostheses is incompletely defined. Objective: To determine the midterm hemodynamic performance of balloon-expandable transcatheter heart valves. Design, Setting, and Participants: In this study, we analyzed core laboratory-generated data from echocardiograms of all patients enrolled in the Placement of Aortic Transcatheter Valves (PARTNER) 1 Trial with successful TAVR or surgical AVR (SAVR) obtained preimplantation and at 7 days, 1 and 6 months, and 1, 2, 3, 4, and 5 years postimplantation. Patients from continued access observational studies were included for comparison. Interventions: Successful implantation after randomization to TAVR vs SAVR (PARTNER 1A; TAVR, n = 321; SAVR, n = 313), TAVR vs medical treatment (PARTNER 1B; TAVR, n = 165), and continued access (TAVR, n = 1996). Five-year echocardiogram data were available for 424 patients after TAVR and 49 after SAVR. Main Outcomes and Measures: Death or reintervention for aortic valve structural indications, measured using aortic valve mean gradient, effective orifice area, Doppler velocity index, and evidence of hemodynamic deterioration by reintervention, adverse hemodynamics, or transvalvular regurgitation. Results: Of 2795 included patients, the mean (SD) age was 84.5 (7.1) years, and 1313 (47.0%) were female. Population hemodynamic trends derived from nonlinear mixed-effects models showed small early favorable changes in the first few months post-TAVR, with a decrease of -2.9 mm Hg in aortic valve mean gradient, an increase of 0.028 in Doppler velocity index, and an increase of 0.09 cm2 in effective orifice area. There was relative stability at a median follow-up of 3.1 (maximum, 5) years. Moderate/severe transvalvular regurgitation was noted in 89 patients (3.7%) after TAVR and increased over time. Patients with SAVR showed no significant changes. In TAVR, death/reintervention was associated with lower ejection fraction, stroke volume index, and aortic valve mean gradient up to 3 years, with no association with Doppler velocity index or valve area. Reintervention occurred in 20 patients (0.8%) after TAVR and in 1 (0.3%) after SAVR and became less frequent over time. Reintervention was caused by structural deterioration of transcatheter heart valves in only 5 patients. Severely abnormal hemodynamics on echocardiograms were also infrequent and not associated with excess death or reintervention for either TAVR or SAVR. Conclusions and Relevance: This large, core laboratory-based study of transcatheter heart valves revealed excellent durability of the transcatheter heart valves and SAVR. Abnormal findings in individual patients, suggestive of valve thrombosis or structural deterioration, were rare in this protocol-driven database and require further investigation. Trial Registration: clinicaltrials.gov Identifier: NCT00530894.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Estudios Longitudinales , Masculino , Reoperación , Volumen Sistólico
13.
Lancet ; 387(10034): 2218-25, 2016 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-27053442

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve demonstrates good 30 day clinical outcomes in patients with severe aortic stenosis who are at intermediate risk of surgical mortality. Here we report longer-term data in intermediate-risk patients given SAPIEN 3 TAVR and compare outcomes to those of intermediate-risk patients given surgical aortic valve replacement. METHODS: In the SAPIEN 3 observational study, 1077 intermediate-risk patients at 51 sites in the USA and Canada were assigned to receive TAVR with the SAPIEN 3 valve [952 [88%] via transfemoral access) between Feb 17, 2014, and Sept 3, 2014. In this population we assessed all-cause mortality and incidence of strokes, re-intervention, and aortic valve regurgitation at 1 year after implantation. Then we compared 1 year outcomes in this population with those for intermediate-risk patients treated with surgical valve replacement in the PARTNER 2A trial between Dec 23, 2011, and Nov 6, 2013, using a prespecified propensity score analysis to account for between-trial differences in baseline characteristics. The clinical events committee and echocardiographic core laboratory methods were the same for both studies. The primary endpoint was the composite of death from any cause, all strokes, and incidence of moderate or severe aortic regurgitation. We did non-inferiority (margin 7·5%) and superiority analyses in propensity score quintiles to calculate pooled weighted proportion differences for outcomes. FINDINGS: At 1 year follow-up of the SAPIEN 3 observational study, 79 of 1077 patients who initiated the TAVR procedure had died (all-cause mortality 7·4%; 6·5% in the transfemoral access subgroup), and disabling strokes had occurred in 24 (2%), aortic valve re-intervention in six (1%), and moderate or severe paravalvular regurgitation in 13 (2%). In the propensity-score analysis we included 963 patients treated with SAPIEN 3 TAVR and 747 with surgical valve replacement. For the primary composite endpoint of mortality, strokes, and moderate or severe aortic regurgitation, TAVR was both non-inferior (pooled weighted proportion difference of -9·2%; 90% CI -12·4 to -6; p<0·0001) and superior (-9·2%, 95% CI -13·0 to -5·4; p<0·0001) to surgical valve replacement. INTERPRETATION: TAVR with SAPIEN 3 in intermediate-risk patients with severe aortic stenosis is associated with low mortality, strokes, and regurgitation at 1 year. The propensity score analysis indicates a significant superiority for our composite outcome with TAVR compared with surgery, suggesting that TAVR might be the preferred treatment alternative in intermediate-risk patients. FUNDING: None.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Tiempo de Internación , Masculino , Puntaje de Propensión , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
14.
Ann Intern Med ; 164(6): 377-84, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26903039

RESUMEN

BACKGROUND: Female sex is associated with poorer outcomes after surgical aortic valve replacement (SAVR). Data on sex-specific differences after transcatheter aortic valve replacement (TAVR) are conflicting. OBJECTIVE: To examine sex-specific differences in patients undergoing TAVR in the PARTNER (Placement of Aortic Transcatheter Valves) trial. DESIGN: Secondary analysis of the randomized and nonrandomized portions of the PARTNER trial. (ClinicalTrials.gov: NCT00530894). SETTING: 25 hospitals in the United States, Canada, and Germany. PATIENTS: High-risk and inoperable patients (1220 women and 1339 men). INTERVENTION: TAVR. MEASUREMENTS: Demographic characteristics, cardiac and noncardiac comorbidities, mortality, stroke, rehospitalization, vascular complications, bleeding complications, and echocardiographic valve parameters. RESULTS: At baseline, women had lower rates of hyperlipidemia, diabetes, smoking, and renal disease but higher Society of Thoracic Surgeons Predicted Risk of Mortality scores (11.9% vs. 11.1%; P < 0.001). After TAVR, women had more vascular complications (17.3% vs. 10.0%; difference, 7.29 percentage points [95% CI, 4.63 to 9.95 percentage points]; P < 0.001) and major bleeding (10.5% vs. 7.7%; difference, 2.8 percentage points [CI, 0.57 to 5.04 percentage points]; P = 0.012) but less frequent moderate and severe paravalvular regurgitation (6.0% vs. 14.3%; difference, -8.3 percentage points [CI, -11.7 to -5.0 percentage points]; P < 0.001). At 30 days, the unadjusted all-cause mortality rate (6.5% vs. 5.9%; difference, 0.6 percentage point [CI, -1.29 to 2.45 percentage points]; P = 0.52) and stroke incidence (3.8% vs. 3.0%; difference, 0.8 percentage point [CI, -0.62 to 2.19 percentage points]; P = 0.28) were similar. At 1 year, all-cause mortality was significantly lower in women than in men (19.0% vs. 25.9%; hazard ratio, 0.72 [CI, 0.61 to 0.85]; P < 0.001). LIMITATION: Secondary analysis that included nonrandomized trial data. CONCLUSION: Despite a higher incidence of vascular and bleeding complications, women having TAVR had lower mortality than men at 1 year. Thus, sex-specific risk in TAVR is the opposite of that in SAVR, for which female sex has been shown to be independently associated with an adverse prognosis. PRIMARY FUNDING SOURCE: Edwards Lifesciences.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Causas de Muerte , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Readmisión del Paciente , Hemorragia Posoperatoria/epidemiología , Factores de Riesgo , Factores Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Enfermedades Vasculares/epidemiología
15.
JACC Cardiovasc Interv ; 9(1): 68-75, 2016 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-26762913

RESUMEN

OBJECTIVES: The aim of this study was to assess the 1-year outcome after transcatheter aortic valve replacement (TAVR) of the Direct Flow Medical (DFM) valve in patients with severe symptomatic aortic stenosis who were contraindicated or high risk for surgery. BACKGROUND: The DFM transcatheter heart valve is a new-generation, nonmetallic aortic valve with a pressurized support structure and conformable double-ring annular sealing delivered through an 18-F sheath. The device allows repositioning, retrieval, and assessment of valve performance before permanent implantation. METHODS: A prospective multicenter European registry was set up to determine the safety and performance of the valve in 100 consecutive patients (10 centers). Echocardiographic and angiographic data were evaluated by an independent core laboratory, and adverse events were adjudicated by a clinical events committee using Valve Academic Research Consortium criteria. RESULTS: Patients were 83.1 ± 5.9 years of age and had a logistic EuroSCORE of 22.5 ± 11.3% and a Society of Thoracic Surgeons score of 9.7 ± 8.7%. Correct valve positioning was obtained in 99% of cases with a combined 30-day safety endpoint at 10%, including major stroke in 5.0%, major vascular complications in 2.0%, and death in 1%. At 12 months, 95% of patients were in New York Heart Association functional class I or II. Freedom from any death was 90%, and freedom from any death or major stroke was 85%. Echocardiography demonstrated none/trace to mild aortic regurgitation in 100% of patients and an unchanged mean aortic gradient of 12.2 ± 6.6 mm Hg and effective orifice area of 1.6 ± 0.4 cm(2). CONCLUSIONS: At 1 year, the DFM transcatheter heart valve had durable hemodynamics. This study demonstrates that the low rate of early complications and the low risk of significant aortic regurgitation translated into midterm clinical benefit.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Supervivencia sin Enfermedad , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
16.
Eur Heart J ; 36(7): 449-56, 2015 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-25273886

RESUMEN

AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/patología , Ecocardiografía , Femenino , Prolapso de las Válvulas Cardíacas , Humanos , Masculino , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/patología , Tamaño de los Órganos , Reoperación/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
17.
J Am Coll Cardiol ; 63(15): 1522-8, 2014 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-24561149

RESUMEN

OBJECTIVES: This study sought to examine sex-specific differences in outcomes after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) in high-risk patients with severe aortic stenosis. BACKGROUND: The PARTNER (Placement of Aortic Transcatheter Valve) trial demonstrated similar 2-year survival with SAVR or TAVR for high-risk patients, but sex-specific outcomes are unknown. METHODS: In all, 699 patients (300 female) were randomly assigned 1:1 to either SAVR or TAVR with a balloon expandable pericardial tissue valve. Baseline characteristics and 2-year outcomes of TAVR versus SAVR were compared among males and females. RESULTS: Baseline characteristics differed between the sexes. Despite higher Society of Thoracic Surgeons mortality risk scores (11.9 vs. 11.6; p = 0.05), female patients had lower prevalence of coronary artery disease (64.4% vs. 83.7%), prior coronary artery bypass graft surgery (19.8% vs. 61.2%), peripheral vascular disease (36.4% vs. 46.9%), diabetes mellitus (35.6% vs. 45.6%), and elevated creatinine (11.7% vs. 23.9%). Among female patients, procedural mortality trended lower with TAVR versus SAVR (6.8% vs. 13.1%; p = 0.07) and was maintained throughout follow-up (hazard ratio [HR]: 0.67; 95% confidence interval [CI]: 0.44 to 1.00; p = 0.049), driven by the transfemoral arm (HR: 0.55; 95% CI: 0.32 to 0.93; p = 0.02). Among male patients, although procedural mortality was lower with TAVR (6% vs. 12.1%; p = 0.03), there was no overall survival benefit (HR: 1.15; 95% CI: 0.82 to 1.61; p = 0.42). CONCLUSIONS: In this retrospective subanalysis of high-risk, symptomatic aortic stenosis patients in the PARTNER trial, female subjects had lower late mortality with TAVR versus SAVR. This was especially true among patients suitable for transfemoral access and suggests that TAVR may be preferred over surgery for high-risk female patients. A randomized, controlled trial conducted specifically in female patients is necessary to properly study differences in mortality between treatment modalities. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/epidemiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Ecocardiografía , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Distribución por Sexo , Factores Sexuales , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
18.
Circulation ; 128(15): 1667-74, 2013 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-24014834

RESUMEN

BACKGROUND: MitraClip has been shown to reduce mitral regurgitation (MR) severity safely but to a lesser degree than surgery. No data exist on the magnitude of MR reduction necessary to reverse left ventricular (LV) and left atrial (LA) dilation in patients with severe MR. Therefore, an analysis was performed to evaluate the relationship between MR reduction and LV and LA volumes after MitraClip therapy. METHODS AND RESULTS: A total of 801 patients treated with MitraClip and 80 patients treated surgically were included. All patients had severe (3-4+) MR. MR severity, LV volumes at end-diastole and end-systole, and LA volumes were measured at baseline, discharge, 30 days, 6 months, and 1 year by an independent echocardiographic core laboratory. A linear repeated measures model was developed to determine the relationship between MR severity and time of measurement postindex procedure on longitudinal LV and LA volumes. Separate models were fit for functional MR and degenerative MR. In both degenerative and functional MR, reduction in LV volumes at end-diastole was associated with degree of residual MR at 12 months (P<0.0001). LV volumes at end-systole was significantly reduced in functional MR but not degenerative MR. LA volumes were significantly related to reduction of MR severity in both groups. CONCLUSIONS: Reduction of LV volumes at end-diastole and LA volumes, but not LV volumes at end-systole in degenerative MR, is consistent with correction of volume overload from primary MR. Reduction of all 3 measurements in functional MR demonstrates reverse remodeling when MR severity is reduced to either 1+ or 2+ by MitraClip therapy. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00209274.


Asunto(s)
Remodelación Atrial/fisiología , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Remodelación Ventricular/fisiología , Anciano , Anciano de 80 o más Años , Volumen Cardíaco/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Ultrasonografía
19.
Circ Cardiovasc Imaging ; 6(4): 522-30, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23633132

RESUMEN

BACKGROUND: Percutaneous repair of mitral regurgitation (MR) permits examination of the effect of MR reduction without surgery and cardiopulmonary bypass on left ventricular (LV) dimensions and function. The goal of this analysis was to determine the extent of reverse remodeling at 12 months after successful percutaneous reduction of MR with the MitraClip device. METHODS AND RESULTS: Of 64 patients with 3 and 4+ MR who achieved acute procedural success after treatment with the MitraClip device, 49 patients had moderate or less MR at 12-month follow-up. Their baseline and 12-month echocardiograms were compared between the group with and without LV dysfunction. In patients with persistent MR reduction and pre-existing LV dysfunction, there was a reduction in LV wall stress, reduced LV end-diastolic volume, LV end-systolic volume and increase in LV ejection fraction in contrast to those with normal baseline LV function, who showed reduction in LV end-diastolic volume, LV wall stress, no change in LV end-systolic volume, and a fall in LV ejection fraction. CONCLUSIONS: Patients with pre-existing LV dysfunction demonstrate reverse remodeling and improved LV ejection fraction after percutaneous mitral valve repair. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00209339, NCT00209274.


Asunto(s)
Cateterismo Cardíaco , Ventrículos Cardíacos/fisiopatología , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/terapia , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Canadá , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Diseño de Equipo , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Recuperación de la Función , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía , Estados Unidos , Disfunción Ventricular Izquierda/diagnóstico por imagen
20.
J Am Soc Echocardiogr ; 26(4): 348-358.e3, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23465887

RESUMEN

BACKGROUND: Multicenter clinical trials use echocardiographic core laboratories to ensure expertise and consistency in the assessment of imaging eligibility criteria, as well as safety and efficacy end points. The aim of this study was to report the real-world implementation of guidelines for best practices in echocardiographic core laboratories, including their feasibility and quality results, in a large, international multicenter trial. METHODS: Processes and procedures were developed to optimize the acquisition and analysis of echocardiograms for the Placement of Aortic Transcatheter Valves (PARTNER) I trial of percutaneous aortic valve replacement for aortic stenosis. Comparison of baseline findings in the operative and nonoperative cohorts and reproducibility analyses were performed. RESULTS: Echocardiography was performed in 1,055 patients (mean age, 83 years; 54% men) The average peak and mean aortic valve gradients were 73 ± 24 and 43 ± 15 mm Hg, and the average aortic valve area was 0.64 ± 0.20 cm(2). The average ejection fraction was 52 ± 13% by visual estimation and 53 ± 14% by biplane planimetry. The mean left ventricular mass index was 151 ± 42 g/m(2). The inoperable cohort had lower left ventricular mass and mass indexes and tended to have more severe mitral regurgitation. Core lab reproducibility was excellent, with intraclass correlation coefficients ranging from 0.92 to 0.99 and κ statistics from 0.58 to 0.85 for key variables. The image acquisition quality improvement process brought measurability to >85%, which was maintained for the duration of the study. CONCLUSIONS: This real-world echocardiographic core lab experience in the PARTNER I trial demonstrates that a high standard of measurability and reproducibility can result from extensive quality assurance efforts in both image acquisition and analysis. These results and the echocardiographic data reported here provide a reference for future studies of aortic stenosis patients and should encourage the wider use of echocardiography in clinical research.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Benchmarking , Ecocardiografía/normas , Implantación de Prótesis de Válvulas Cardíacas , Cirugía Asistida por Computador/normas , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Ensayos Clínicos como Asunto , Ecocardiografía Doppler , Estudios de Factibilidad , Femenino , Adhesión a Directriz , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Procesamiento de Imagen Asistido por Computador , Laboratorios , Masculino , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA