Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Hortic Res ; 11(1): uhad258, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38298899

RESUMEN

Scutellaria baicalensis Georgi, also known as huang-qin in traditional Chinese medicine, is a widely used herbal remedy due to its anticancer, antivirus, and hepatoprotective properties. The S. baicalensis genome was sequenced many years ago; by contrast, the proteome as the executer of most biological processes of S. baicalensis in the aerial parts, as well as the secondary structure of the roots (xylem, phloem, and periderm), is far less comprehensively characterized. Here we attempt to depict the molecular landscape of the non-model plant S. baicalensis through a multi-omics approach, with the goal of constructing a highly informative and valuable reference dataset. Furthermore, we provide an in-depth characterization dissection to explain the two distinct flavonoid biosynthesis pathways that exist in the aerial parts and root, at the protein and phosphorylated protein levels. Our study provides detailed spatial proteomic and phosphoproteomic information in the context of secondary structures, with implications for the molecular profiling of secondary metabolite biosynthesis in non-model medicinal plants.

2.
Int J Anal Chem ; 2021: 5524361, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34567122

RESUMEN

OBJECTIVE: To develop a new method for quantitatively analyzing six tyrosine kinase inhibitors (gefitinib, erlotinib, icotinib, afatinib, osimertinib, and crizotinib) used in the treatment of non-small cell lung cancer (NSCLC) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: The analytes were detected in the selected reaction monitoring mode on a triple quadrupole mass spectrometer with the positive ionization mode. Carbamazepine was utilized as the internal standard. The pretreatment of the plasma sample was completed based on protein precipitation with acetonitrile, and the analytes were separated on an Agilent Zorbax SB-C18 reversed-phase column (2.1 mm × 100 mm, 3.5 µm, Agilent, USA) using gradient elution. The mobile phase consisted of 0.1% formic acid in water (phase A) and 0.1% formic acid in acetonitrile (phase B). The flow rate was 0.3 mL/min, and the injection volume was 5 µL. The column temperature was set and maintained at 35°C. RESULTS: The calibration curves were linear over the range from 5.0 to 1000.0 ng/mL for gefitinib, crizotinib, and osimertinib; from 50.0 to 4000.0 ng/mL for icotinib and erlotinib; and from 5.0 to 400.0 ng/mL for afatinib. Linear correlation coefficients were >0.990 for all regression curves. The intra- and interday accuracy and precision of the method were within ±15.0% and not more than 15.0%, respectively. The mean recovery of all the analytes ranged from 70.18% to 110.76%, the matrix effect was from 88.85% to 127.58%, and stability was within ±15.0%. CONCLUSION: This newly developed method was sensitive, simple, and robust and could be used in therapeutic drug monitoring of six tyrosine kinase inhibitors in NSCLC patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA