Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Am J Transl Res ; 16(8): 3654-3666, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39262737

RESUMEN

OBJECTIVE: To construct a diagnostic model for follicular thyroid carcinoma (FTC) and papillary thyroid carcinoma (PTC), both subtypes of differentiated thyroid carcinoma (DTC), using color Doppler ultrasound signs in conjunction with serum laboratory markers. METHODS: We conducted a retrospective analysis of patients with thyroid nodules who underwent ultrasonography at Yulin Hospital from February 2021 to March 2023. The cohort included 269 subjects: 105 with benign nodules and 164 with DTC (59 with FTC and 105 with PTC). We compared baseline demographics and laboratory indices between the groups. Diagnostic values of ultrasound features and laboratory markers were assessed using receiver operating characteristic (ROC) curves, and logistic regression was employed to pinpoint independent diagnostic factors for FTC. A predictive nomogram was subsequently developed based on these factors. RESULTS: There were significant differences between the benign and malignant groups regarding ultrasound signs (including border, morphology, echogenicity, calcification, blood flow, lymph node zoning) and laboratory indices (free triiodothyronine (FT3), free thyroxine (FT4), thyroglobulin (Tg), thyroid-stimulating hormone (TSH), vascular endothelial growth factor (VEGF), tumor-specific growth factor (TSGF)), with all P-values <0.05. The areas under the curve (AUCs) for FT3, FT4, Tg, TSH, VEGF, and TSGF were all above 0.75, with Tg achieving the highest at 0.91. Logistic regression identified borders, morphology, echogenicity, VEGF, and TSGF as independent diagnostic factors for distinguishing between FTC and PTC, with significant P-values. The constructed nomogram demonstrated an AUC of 0.853, indicating high diagnostic accuracy. Both calibration and decision curve analysis (DCA) validated the model's stability and clinical utility. CONCLUSION: We successfully developed a nomogram combining ultrasound features and serum markers that enhances the diagnostic precision for FTC. This model offers a valuable tool for clinical diagnostics in differentiated thyroid cancer.

2.
Xenotransplantation ; 31(4): e12873, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38961605

RESUMEN

BACKGROUND: Significant progress has been made in kidney xenotransplantation in the past few years, and this field is accelerating towards clinical translation. Therefore, surveillance of the xenograft with appropriate tools is of great importance. Ultrasonography has been widely used in kidney allotransplantation and served as an economical and non-invasive method to monitor the allograft. However, questions remain whether the ultrasonographic criteria established for human kidney allograft could also be applied in xenotransplantation. METHODS: In the current study, we established a porcine-rhesus life sustaining kidney xenotransplantation model. The xenograft underwent intensive surveillance using gray-scale, colorful Doppler ultrasound as well as 2D shear wave elastography. The kidney growth, blood perfusion, and cortical stiffness were measured twice a day. These parameters were compared with the clinical data including urine output, chemistry, and pathological findings. RESULTS: The observation continued for 16 days after transplantation. Decline of urine output and elevated serum creatinine were observed on POD9 and biopsy proven antibody-mediated rejection was seen on the same day. The xenograft underwent substantial growth, with the long axis length increased by 32% and the volume increased by threefold at the end of observation. The resistive index of the xenograft arteries elevated in response to rejection, together with impaired cortical perfusion, while the peak systolic velocity (PSV) was not compromised. The cortical stiffness also increased along with rejection. CONCLUSION: In summary, the ultrasound findings of kidney xenograft shared similarities with those in allograft but possessed some unique features. A modified criteria needs to be established for further application of ultrasound in kidney xenotransplantation.


Asunto(s)
Rechazo de Injerto , Xenoinjertos , Trasplante de Riñón , Riñón , Macaca mulatta , Trasplante Heterólogo , Animales , Trasplante Heterólogo/métodos , Trasplante de Riñón/métodos , Porcinos , Riñón/diagnóstico por imagen , Humanos , Ultrasonografía/métodos
3.
Insights Imaging ; 15(1): 181, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39060856

RESUMEN

OBJECTIVES: To compare color Doppler ultrasound and contrast-enhanced ultrasound (CEUS) in evaluating vascular invasion in pancreatic ductal adenocarcinoma (PDAC). MATERIALS AND METHODS: This retrospective study included 210 patients with PDAC who were evaluated by color Doppler ultrasound, CEUS, and contrast-enhanced computed tomography (CECT) at our institution between January 2017 and December 2020. Pathologic results were used as the gold standard in patients who underwent surgical and intraoperative exploration. For nonsurgical patients, CECT results were used as the reference standard. The vessels evaluated included those in the peripancreatic arterial system and venous system. The diagnostic performances of color Doppler ultrasound and CEUS for vascular invasion were compared. RESULTS: In 51 patients who underwent surgery and intraoperative exploration, color Doppler ultrasound and CEUS differed only in assessing venous system invasion in patients with PDAC of the pancreatic body and tail, with the former being superior to the latter. In 159 nonsurgical patients, there was no difference between CEUS and color Doppler ultrasound in assessing superior mesenteric arteriovenous invasion. CEUS was superior to color Doppler ultrasound in evaluating the celiac artery and its branches, with an accuracy of up to 97.8% for some vessels. Color Doppler ultrasound was ideal for evaluating the splenic and portal veins. CONCLUSION: CEUS is more suitable for the evaluation of peripancreatic arteries than color Doppler. CEUS combined with color Doppler ultrasound can be used as a potential supplement to CECT and is also expected to be used to evaluate vascular invasion of PDAC after chemotherapy. CRITICAL RELEVANCE STATEMENT: Contrast-enhanced US and color Doppler in the assessment of vascular invasion in pancreatic ductal adenocarcinoma have their respective advantages, through standardized ultrasound processes are expected to improve the efficiency of inspection. KEY POINTS: Contrast-enhanced US has unique advantages in assessing pancreatic ductal adenocarcinoma invasion of the celiac artery. Doppler imaging is of high value in assessing venous system invasion. Standardization of ultrasound imaging procedures for pancreatic ductal adenocarcinoma is expected to improve efficiency.

4.
Am J Transl Res ; 16(6): 2645-2653, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006293

RESUMEN

OBJECTIVE: This study aimed to develop a diagnostic model utilizing quantitative ultrasound parameters to accurately differentiate benign from malignant thyroid nodules. METHODS: A retrospective analysis of 194 patients with thyroid nodules, encompassing 65 malignant and 129 benign cases, was performed. Clinical data, ultrasound characteristics, and hemodynamic indicators were compared. Receiver operating characteristic (ROC) curves and logistic regression analysis identified independent diagnostic markers. RESULTS: No significant differences in clinical data were observed between the groups (P>0.05). Malignant nodules, however, were more likely to exhibit solid composition, hypoechoicity, irregular shapes, calcifications, central blood flow, and unclear margins (P<0.05). Hemodynamic parameters showed that malignant nodules had lower end-diastolic volume (EDV) but higher peak systolic velocity (PSV), resistive index (RI), and vascularization flow index (VFI) (P<0.001). Independent diagnostic factors identified included calcification, margin definition, RI, and VFI. A risk prediction model was formulated, demonstrating significantly lower scores for benign nodules (P<0.0001), achieving an ROC area of 0.964. CONCLUSION: Color Doppler ultrasound effectively distinguishes malignant from benign thyroid nodules. The diagnostic model emphasizes the importance of calcification, margin clarity, RI, and VFI as critical elements, enhancing the accuracy of thyroid nodule characterization and facilitating informed clinical decisions.

5.
Heliyon ; 10(11): e30352, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38868048

RESUMEN

Objective: It was to investigate the diagnosis of fetal hemodynamics in pregnant women with diabetes mellitus in the third trimester of pregnancy by color Doppler ultrasonography. Methods: 55 women with gestational diabetes mellitus (GDM) in the third trimester of pregnancy who were clinically diagnosed and treated in Haian City People's Hospital of Jiangsu Province were selected as the observation group, and 55 pregnant women with normal prenatal examination results were selected as the controls. The hemodynamic parameters of fetal middle cerebral artery (MCA), umbilical artery (UA), and renal artery (RA) were detected, including the ratio of maximum systolic blood flow velocity to end-diastolic blood flow velocity (S/D), resistance index (RI) and arterial pulsation index (PI). Fasting serum levels of maternal patients were collected for detecting Cystain C (Cys C) and homocysteine (Hcy) to analyze the predictive value of serological indexes and target arterial hemodynamics parameters for adverse pregnancy outcome (APO). Results: The results showed that compared with controls, in the observation group, RI, PI, and S/D of MCA and RA increased significantly, while RI, PI and S/D of UA decreased obviously (P < 0.05), the levels of serum Cys C and Hcy were clearly increased (P < 0.05). The APO rate of controls and observation group was 10.91 % and 25.45 %, respectively. It was found that the area under the curve of serum Cys C, Hcy, and the APO predicted by the hemodynamic parameters of fetal MCA, UA, and RA were all greater than 0.75 (P < 0.05). Multiple Logistic regression analysis showed that serum Cys C and Hcy, and the hemodynamic parameters of fetal MCA, UA and RA were correlated with APO (P < 0.05). Conclusion: In summary, maternal blood glucose level can affect fetal hemodynamic parameters. In the third trimester of pregnancy, the changes of blood flow parameters of fetal MCA, UA, RA, and maternal serum Cys C and Hcy levels are helpful to understand fetal status in utero, and can be used to predict APO.

6.
Hand Clin ; 40(2): 167-177, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38553088

RESUMEN

Accurate preoperative localization of dominant perforators provides crucial information about their location and diameter, leading to reduced surgical time, improved flap viability, and decreased complications. Ultrasound has increased in popularity in recent years, with the advantages of providing reproducible, accurate, cost-effective, and real-time information while reducing radiation exposure. Precise preoperative mapping of perforators allows for rapid and safe elevation of suprafascial, thin, and superthin flaps. This review focuses on the role of ultrasound as a tool for preoperative flap planning in the upper extremities.


Asunto(s)
Colgajo Perforante , Humanos , Extremidad Superior/cirugía
7.
J Ultrasound ; 27(2): 363-373, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38393451

RESUMEN

AIMS: While hormonal assays are commonly used for thyroid function assessment, Doppler sonography provides valuable information on vascularization and blood flow. This study aimed to examine the potential associations between Doppler parameters and clinical characteristics of hypothyroid patients, such as the autoimmune nature of the disease and adequacy of LT4 replacement. METHODS: A total of 338 patients with hypothyroidism, primarily caused by autoimmune thyroiditis (AT), were enrolled in this study. Exclusion criteria comprised specific medical conditions, medication history, and nodular abnormalities of the thyroid gland. Patient demographics (age, sex, BMI), treatment parameters (LT4 daily dose), and thyroid hormone levels (TSH, fT4) were recorded. RESULTS: Among the enrolled patients, 85.2% had autoimmune thyroiditis. Suboptimal levothyroxine (LT4) replacement was observed in 20.1% of patients at the time of enrollment. Patients with autoimmune thyroiditis had increased elastography ratios compared to those without autoimmune disease and present a positive association of elastography ratios with vascularity. In patients without autoimmune thyroiditis, those with suboptimal LT4 replacement had lower total thyroid volume. Patients with suboptimal LT4 replacement had higher peak systolic velocity (PSV) and end-diastolic velocity (EDV) in the inferior thyroid artery and lower resistive index (RI). The severity of hypothyroidism, as indicated by LT4 dose/body mass index (BMI), was negatively correlated with thyroid volume and EDV values of superior and inferior thyroid arteries. PSV of the inferior thyroid artery can predict suboptimal LT4 replacement (sensitivity 81.8%, specificity 42%). CONCLUSIONS: In situations where obtaining blood tests may be challenging, utilizing color Doppler ultrasound can serve as an alternative method to assess treatment responses and identify patients who require further hormonal examinations.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipotiroidismo , Tiroxina , Ultrasonografía Doppler en Color , Humanos , Tiroxina/uso terapéutico , Tiroxina/sangre , Femenino , Masculino , Hipotiroidismo/diagnóstico por imagen , Hipotiroidismo/tratamiento farmacológico , Hipotiroidismo/sangre , Estudios Transversales , Persona de Mediana Edad , Adulto , Diagnóstico por Imagen de Elasticidad/métodos , Terapia de Reemplazo de Hormonas/métodos , Glándula Tiroides/diagnóstico por imagen , Tiroiditis Autoinmune/diagnóstico por imagen , Tiroiditis Autoinmune/sangre , Tiroiditis Autoinmune/tratamiento farmacológico , Anciano
8.
J Vasc Surg Venous Lymphat Disord ; 12(3): 101851, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38360403

RESUMEN

OBJECTIVE: Pelvic venous reflux may be responsible for pelvic venous disorders and/or lower-limb (LL) varicose veins. Ultrasound investigation with Doppler allows a complete study of the entire infra-diaphragmatic venous reservoir. The aim of this study was to guide and standardize the investigation of the pelvic origin of venous reflux in female patients with LL varicose veins. METHODS: In this case-control study, we applied a comprehensive ultrasound investigation protocol, which involved four steps: (1) venous mapping of the lower limbs; (2) transperineal and vulvar approach; (3) transabdominal approach; and (4) transvaginal approach. RESULTS: Forty-four patients in group 1 (patients with LL varicose veins and pelvic escape points [PEPs]) and 35 patients in group 2 (patients with LL varicose veins without PEPs [control group]) were studied, matched by age. The median age was 43 years in both groups. The calculated body mass index was lower in group 1 (23.4 kg/m2) compared with the control group (25.4 kg/m2), and this difference reached statistical significance (P < .001). The presence of pelvic varicose veins (PVs) by transvaginal ultrasound was 86% in group 1 and 31% in group 2. Perineal PEPs were the most prevalent, being found in 35 patients (79.5%), more frequent on the right (57.14%) than on the left (42.85%) and associated with bilateral PVs 65.7% of the time. In group 1, 23 patients (52%) reported recurrent varicose veins vs eight patients (23%) in the control group (P = .008). Regarding the complaint of dyspareunia, a significant difference was identified between the groups (P = .019), being reported in 10 (23%) patients in group 1 vs one patient (2.9%) in the control group. The median diameters in the transabdominal approach of the left gonadal veins were 6.70 mm for group 1 and 4.60 mm for group 2 (P < .001). In patients with PVs in group 1, the median diameter of PEPs at the trans-perineal window was 4.05 mm. In the transvaginal examination, the mean diameter of the veins in the peri uterine region was 8.71 mm on the left and 7.04 mm on the right. CONCLUSIONS: The identification of PEPs by venous mapping demonstrates the pelvic origin of the reflux and its connections with the LL varicose veins. For a more adequate treatment plan, we suggest a complete investigation protocol based on the transabdominal and transvaginal study to rule out venous obstructions, thrombotic or not, and confirm the presence of varicose veins in the pelvic adnexal region.


Asunto(s)
Várices , Insuficiencia Venosa , Humanos , Femenino , Adulto , Insuficiencia Venosa/terapia , Estudios de Casos y Controles , Ultrasonografía Doppler Dúplex/métodos , Várices/terapia , Extremidad Inferior/irrigación sanguínea
9.
World J Gastroenterol ; 30(5): 462-470, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38414590

RESUMEN

BACKGROUND: Some hydatid cysts of cystic echinococcosis type 1 (CE1) lack well-defined cyst walls or distinctive endocysts, making them difficult to differentiate from simple hepatic cysts. AIM: To investigate the diagnostic methods for atypical hepatic CE1 and the clinical efficacy of laparoscopic surgeries. METHODS: The clinical data of 93 patients who had a history of visiting endemic areas of CE and were diagnosed with cystic liver lesions for the first time at the People's Hospital of Xinjiang Uygur Autonomous Region (China) from January 2018 to September 2023 were retrospectively analyzed. Clinical diagnoses were made based on findings from serum immunoglobulin tests for echinococcosis, routine abdominal ultrasound, high-frequency ultrasound, abdominal computed tomography (CT) scan, and laparoscopy. Subsequent to the treatments, these patients underwent reexaminations at the outpatient clinic until October 2023. The evaluations included the diagnostic precision of diverse examinations, the efficacy of surgical approaches, and the incidence of CE recurrence. RESULTS: All 93 patients were diagnosed with simple hepatic cysts by conventional abdominal ultrasound and abdominal CT scan. Among them, 16 patients were preoperatively diagnosed with atypical CE1, and 77 were diagnosed with simple hepatic cysts by high-frequency ultrasound. All the 16 patients preoperatively diagnosed with atypical CE1 underwent laparoscopy, of whom 14 patients were intraoperatively confirmed to have CE1, which was consistent with the postoperative pathological diagnosis, one patient was diagnosed with a mesothelial cyst of the liver, and the other was diagnosed with a hepatic cyst combined with local infection. Among the 77 patients who were preoperatively diagnosed with simple hepatic cysts, 4 received aspiration sclerotherapy of hepatic cysts, and 19 received laparoscopic fenestration. These patients were intraoperatively diagnosed with simple hepatic cysts. During the follow-up period, none of the 14 patients with CE1 experienced recurrence or implantation of hydatid scolices. One of the 77 patients was finally confirmed to have CE complicated with implantation to the right intercostal space. CONCLUSION: Abdominal high-frequency ultrasound can detect CE1 hydatid cysts. The laparoscopic technique serves as a more effective diagnostic and therapeutic tool for CE.


Asunto(s)
Quistes , Equinococosis Hepática , Equinococosis , Hepatopatías , Humanos , Estudios Retrospectivos , Equinococosis/diagnóstico , Equinococosis Hepática/diagnóstico por imagen , Equinococosis Hepática/cirugía , China/epidemiología , Quistes/diagnóstico por imagen , Quistes/cirugía
10.
BMC Med Imaging ; 24(1): 10, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172706

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) provide accurate vascular imaging information, but their use may be contraindicated. Color Doppler ultrasonography (CDU) provides simple, safe, noninvasive, and reproducible imaging. We therefore investigated the role of preoperative CDU combined with CTA and MRA in the quantification, typing, and diagnosis of carotid body tumors (CBTs). METHODS: We retrospectively analyzed patients with CBTs categorized into group A (type I [n = 1] and type II [n = 10]) or group B (type III [n = 56]) per the intraoperative Shamblin classification. CDU, CTA, and MRA characteristics of CBTs were observed, surgical results were correlated, and the diagnostic threshold of the CBT classification was calculated. RESULTS: CBTs were usually located at the common carotid artery bifurcation, encircling the carotid artery. An increased angle was found between the internal and external carotid arteries. On CDU, CBTs primarily presented as homogeneous hypoechoic masses with clear boundaries, rich flow signals, and a high-speed, low-resistance artery-like flow spectrum. CTA showed uniform or heterogeneous marked enhancement. MRA showed mixed T1 and slightly longer T2 signals and uniform or uneven obvious enhancement. With increases in the lesion size, amount of blood transfused, and operation time, the intraoperative classification level and possibility of skull-base invasion increased. When the maximum diameter of the lesion, the volume of the tumor, the distance between the upper margin of the tumor to the mastoid and the mandibular angle were 3.10 cm, 10.15 cm3, - 3.26 cm, and 0.57 cm, respectively, the largest Youden index was the best diagnostic boundary value for Shamblin type III tumors. CONCLUSIONS: CDU combined with CTA and MRA can accurately evaluate the size and classification of CBTs.


Asunto(s)
Tumor del Cuerpo Carotídeo , Angiografía por Tomografía Computarizada , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Resonancia Magnética , Estudios Retrospectivos , Tumor del Cuerpo Carotídeo/patología , Tumor del Cuerpo Carotídeo/cirugía , Ultrasonografía Doppler en Color/métodos
11.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(1): 62-68, 2024 Jan 15.
Artículo en Chino | MEDLINE | ID: mdl-38225843

RESUMEN

Objective: To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF). Methods: Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m 2, with an average of 23.62 kg/m 2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured. Results: A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory. Conclusion: Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.


Asunto(s)
Quemaduras , Lesiones por Aplastamiento , Colgajos Tisulares Libres , Colgajo Perforante , Procedimientos de Cirugía Plástica , Traumatismos de los Tejidos Blandos , Masculino , Femenino , Humanos , Muslo/diagnóstico por imagen , Muslo/cirugía , Estudios Prospectivos , Trasplante de Piel , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Traumatismos de los Tejidos Blandos/cirugía , Ultrasonografía Doppler en Color , Lesiones por Aplastamiento/cirugía , Resultado del Tratamiento
12.
J Ultrasound Med ; 43(4): 791-798, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38269478

RESUMEN

OBJECTIVES: To explore clinical value of miRNA-18a, miRNA-130a, and miRNA-92a combined with transvaginal color Doppler ultrasound (TVCDS) in the diagnosis of cervical cancer (CC). METHODS: One hundred patients with pathologically confirmed CC (CC group), 100 patients with cervical epithelial neoplasia (disease group), and 100 patients with benign uterine lesions (control group) were selected. TVCDS was performed, and the levels of serum miRNA-18a, miRNA-130a, and miRNA-92a were detected. RESULTS: The systolic blood velocity of the cancer group, the disease group, and the control group decreased sequentially, while the resistance index and pulsatility index increased sequentially. The serum miR-18a, miR-130a, miR-92a, and expression levels of the patients' increased sequentially. Multivariate logistic regression analysis showed that age, high-risk human papillomavirus (HR-HPV) infection, menopause, blood flow RI, serum miRNA-18a, miRNA-92a, and miRNA-130a were the influencing factors of CC. The receiver operating characteristic curve showed that the sensitivity, specificity, accuracy, and area under curve of transvaginal Doppler ultrasound in the diagnosis of CC were 86.43%, 88.01%, 84.32%, and 0.913; serum miR-18a were, respectively, 76.56, 81.30, 80.36, and 0.839; serum miR-130a were 77.88%, 76.97%, 78.32%, and 0.0.864; serum miR-92a were 71.04%, 80.39%, 80.74%, and 0.894; 90.33%, 95.14%, 91.25%, and 0.947, the area under curve of the combined detection of the 3 was greater than that of the single detection. CONCLUSIONS: Serum miRNA combined with TVCDS has the advantages of it being noninvasive, and having high sensitivity and high specificity in the diagnosis of CC.


Asunto(s)
MicroARNs , Neoplasias del Cuello Uterino , Femenino , Humanos , MicroARNs/genética , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/patología , Cuello del Útero/patología , Útero/patología , Ultrasonografía Doppler en Color
13.
Ren Fail ; 45(2): 2275714, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37929948

RESUMEN

This study evaluated the clinical value of color Doppler ultrasound-guided percutaneous nephrolithotomy (PCNL) in avoiding bleeding caused by punctured blood vessels. Herein, we retrospectively included patients who underwent color Doppler ultrasound-guided PCNL or PCNL using the conventional channel technique from August 2018 to August 2022. The clinical characteristics of patients during surgery, complications, and hospital stay were recorded and compared. Overall, 228 patients were enrolled, with 126 patients (age, 47.6 ± 13.2 years; men: 57.14%) in the color Doppler ultrasound-guided PCNL group and 102 patients (age, 46.6 ± 12.3 years) in the B-mode ultrasound-guided puncture group. The total operation time (63.5 ± 15.5 vs. 61.3 ± 16.3 min, p = .5236) and stone clearance rate (86.50% vs. 83.33%, p = .7139) were similar between the two groups. However, the puncture time for the color Doppler ultrasound-guided PCNL group was longer than that for the B-mode ultrasound-guided puncture group (5.1 ± 2.3 vs. 2.6 ± 1.6 min, p = .0019). Moreover, the length of postoperative hospital stay in the color Doppler ultrasound-guided PCNL group reduced significantly by ∼1 day compared with that in the B-mode ultrasound-guided puncture group (4.5 ± 1.6 vs. 5.6 ± 2.1 days, p = .0087). The blood transfusion rate (1.58% vs. 4.9%, p = .0399), sedation-related adverse event rate (0.79% vs. 2.9%, p = .0332), perineal hematoma incidence (0% vs. 2.94%, p < .0001), and serum decreased hemoglobin levels (12.2 ± 9.7 vs. 23.5 ± 10.1 g/L, p < .001) after color Doppler ultrasound-guided PCNL were significantly lower than those after B-mode ultrasound-guided puncture. The stone clearance rate was similar between the two groups, with a similar operation time. Moreover, color Doppler ultrasound-guided PCNL shortened the postoperative hospital stay and decreased Hb levels, blood transfusion rate, and perineal hematoma incidence.


Asunto(s)
Cálculos Renales , Nefrolitotomía Percutánea , Nefrostomía Percutánea , Masculino , Humanos , Adulto , Persona de Mediana Edad , Nefrolitotomía Percutánea/efectos adversos , Nefrolitotomía Percutánea/métodos , Estudios Retrospectivos , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Nefrostomía Percutánea/efectos adversos , Nefrostomía Percutánea/métodos , Resultado del Tratamiento , Ultrasonografía Doppler en Color , Hematoma/etiología
14.
Vestn Otorinolaringol ; 88(5): 27-33, 2023.
Artículo en Ruso | MEDLINE | ID: mdl-37970767

RESUMEN

OBJECTIVE: To assess the efficiency and the place of grey scale ultrasound and color Doppler sonography of the larynx in the diagnosis of laryngeal pathology. MATERIAL AND METHODS: A prospective blind cohort examination in B-mode laryngeal ultrasound (LUS) and color Doppler imaging (CDI) with linear scanning transducer 7-15 MHz was performed in 120 patients aged from 6 months to 52 years (average age 7.6±5.8 years, Me 6 year) and in 40 patients without laryngeal pathology (average age 7.0±5.0 years). The patients presented with complaints of voice and/or stridor. The diagnosis was verified by followed laryngoscopy. RESULTS: Laryngeal papillomas, hemangiomas, scarring and vocal fold's nodules were identified as hyperechoic formations. Color Doppler sonography made it possible to visualize them better: small formations were highlighted in color and the space around the large ones was colored. There were paradoxical movements of the hyperechoic arytenoid cartilages during inspiration to the anterior commissure in patients with laryngomalacia. Color Doppler ultrasonography revealed changes during phonation in patients with functional dysphonia. The sensitivity and specificity of LUS were 58% (95% CI 48-66) and 98% (95% CI 87-99) compared with laryngoscopy in the detection of laryngeal pathology, but laryngeal CDI - 81% (95% CI 72-87) and 98% (95% CI 87-99) respectively. CONCLUSION: Ultrasound of the larynx in B-mode has a diagnostic efficiency of 67.5%, and in CDI mode - 85% for ruling in laryngeal pathologies compared to laryngoscopy. So, this method is a modern affordable, non-invasive and informative diagnostic tool for the detection of laryngeal diseases, especially in those cases, when it is impossible to carry out a laryngoscopy.


Asunto(s)
Neoplasias Laríngeas , Laringe , Humanos , Lactante , Preescolar , Niño , Adolescente , Pliegues Vocales/patología , Estudios Prospectivos , Laringe/diagnóstico por imagen , Laringoscopía/métodos , Neoplasias Laríngeas/diagnóstico por imagen , Neoplasias Laríngeas/patología
15.
Cancers (Basel) ; 15(22)2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-38001591

RESUMEN

BACKGROUND: Ultrasonography (US) represents the gold standard imaging method for the assessment of testicular lesions (TL). The gray-scale (GSUS) and color-Doppler (CDUS) ultrasound examination allow sonographers to investigate the size, margins, echotexture, and vascular features of TLs with the aim to differentiate benign from malignant lesions. Recently, the use of contrast-enhanced US (CEUS) and sonoelastography (SE) has led to further improvements in the differential diagnosis of TL. Although GSUS and CDUS are often sufficient to suggest the benign or malignant nature of the TL, CEUS can be decisive in the differential diagnosis of unclear findings, while SE can help to strengthen the diagnosis. The contemporary combination of GSUS, CDUS, CEUS, and SE has led to a new diagnostic paradigm named multiparametric US (mp-US), which is able to provide a more detailed characterization of TLs than single techniques alone. This narrative and pictorial review aimed to describe the mp-US appearance of several TLs. METHODS: An extensive Medline search was performed to identify studies in the English language focusing on the mp-US evaluation of TLs. RESULTS: A practical mp-US "identity card" and iconographic characterization of several benign and malignant TLs is provided herein. CONCLUSIONS: The mp-US characterization of TL reported herein can be useful in daily clinical practice.

16.
Pak J Med Sci ; 39(5): 1366-1371, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37680794

RESUMEN

Objective: To investigate the diagnostic value of ultrasound for patients with axillary lymph node-negative breast cancer (ALNNBC). Methods: A retrospective analysis was performed on the clinical data of 204 breast cancer patients who were admitted by Quanzhou First Hospital Affiliated to Fujian Medical University between October 2020 and May 2022. According to the results of axillary lymph node (ALN) examination, the patients were assigned to a positive group(n=102) and a negative group(n=102). All patients underwent diagnosis with color Doppler ultrasound, with pathological diagnosis as the "gold standard" to determine the sensitivity and specificity of ultrasonic diagnosis. A receiver operating characteristic(ROC) curve was established to analyze the efficiency of ultrasonic diagnosis and compare the ultrasonographic features and flow grades between the two groups. Results: Differences were statistically significant between the two groups in ultrasonographic features of lesions(negative vs positive, all p<0.05), including morphological irregularity(59.8% vs 85.3%), spiky margins(19.6% vs 63.7%), posterior echo attenuation(19.6% vs 44.1%) and microcalcification(40.2% vs 55.89%). The negative group had a lower proportion of patients with grade 2-3 ultrasound blood flow when compared with the positive group(32.4% vs 56.86%), and the difference was statistically significant(p<0.05). Ultrasonic diagnosis of ALNNBC had a sensitivity of 88.24%(90/102), a specificity of 92.16%(94/102), a coincidence rate of 90.20% (184/204), a 95% CI of 0.845-0.928, and an AUC of 0.879. Conclusions: Ultrasonic diagnosis of ALNNBC is relatively efficient as ultrasonographic features and ultrasound blood flow signals can provide a scientific basis for the diagnosis of ALNNBC.

17.
J Plast Reconstr Aesthet Surg ; 86: 48-57, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37696215

RESUMEN

BACKGROUND: Identifying relevant perforators is crucial in planning a deep inferior epigastric perforator (DIEP) flap. Color Doppler ultrasonography (CDU) has gained popularity for localizing perforators; however, current evidence on its efficiency is still inconclusive. This study aimed to compare the efficiency of CDU with that of computed tomography angiography (CTA) in localizing and selecting the relevant perforators. METHODS: In this randomized controlled trial, 60 patients undergoing DIEP flap breast reconstruction (uni- or bilateral) were randomly assigned to the CDU group (i.e., CDU was performed to map and select the relevant perforators preoperatively) or the CTA+CDU group (i.e., mapping was based on CTA and supplemented by CDU). CDU was performed by the same surgeon with a well-defined sonography experience from our previous study. The reference XY coordinates of the dissected perforators were measured intraoperatively, and deviations from preoperatively deducted coordinates were calculated (ΔCDU or ΔCTA+CDU). The flaps were categorized according to the number of dissected perforators, and adherence to the preoperative strategy was evaluated. RESULTS: Overall, 22 patients (30 flaps) in the CTA+CDU group and 27 (39 flaps) patients in the CDU group were evaluated. The average ΔCDU (0.6 cm) was significantly lower than the average ΔCTA+CDU (1.0 cm) (p < 0.001). Adherence to the mapping-based dissection strategy was higher in the CDU group; however, the difference was insignificant (p = 0.092). CONCLUSION: CDU is not inferior to CTA + CDU in localizing and selecting relevant DIEA perforators. Therefore, CDU mapping is a possible complementary or substitute modality for CTA mapping.


Asunto(s)
Mamoplastia , Colgajo Perforante , Humanos , Angiografía por Tomografía Computarizada/métodos , Colgajo Perforante/cirugía , Arterias Epigástricas/diagnóstico por imagen , Arterias Epigástricas/cirugía , Mamoplastia/métodos , Ultrasonografía Doppler en Color
18.
Int J Ophthalmol ; 16(8): 1224-1230, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37602333

RESUMEN

AIM: To observe the imaging features of color Doppler ultrasound (CDU) and computed tomography (CT) or computed tomography dacryocystography (CT-DCG) in different types of lacrimal sac space-occupying lesions (SOLs). METHODS: This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022. The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system. The images were observed and analyzed. RESULTS: The detection rate of lacrimal SOLs between CDU (21/21, 100%) and CT or CT-DCG (20/21, 95.2%) had no statistically significant difference (P=1.0). CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion. Among them, polyps had characteristic imaging changes on CDU and CT-DCG. The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU, which could provide more information for differential diagnosis. CONCLUSION: The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU. CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass. Therefore, CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG.

19.
J Vasc Surg Cases Innov Tech ; 9(2): 101184, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37305361

RESUMEN

Severe obstruction of inferior vena cava (IVC) outflow after orthotopic liver transplantation can result in persistent hypotension, leading to transplantation failure and intraoperative circulatory instability and can even threaten the patient's life. IVC stent implantation is a therapeutic approach to relieve the obstruction of IVC outflow. In the present report, we describe two cases of IVC stent implantation assisted by color Doppler ultrasound during orthotopic liver transplantation to manage the persistent hypotension caused by acute obstruction of IVC outflow. At 1 and 3 months of follow-up, the stent position was optimal, and the stent and IVC patency were satisfactory without thrombosis.

20.
Front Oncol ; 13: 1027238, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37213279

RESUMEN

Congenital portosystemic shunts (CPSS) are rare vascular anomalies that cause abnormal communications between the portal and systemic venous systems and may be incidentally detected on imaging or via abnormal laboratory parameters due to the lack of specificity in the condition's clinical presentation. Ultrasound (US) is a common tool for examining abdominal solid organs and vessels and is the initial imaging modality for diagnosing CPSS. Here we report the case of an 8-year-old Chinese boy with CPSS diagnosed using color Doppler US. Doppler US first found intrahepatic tumor, then revealed that the left portal vein was directly communicating with the inferior vena cava, and the boy was finally diagnosed with intrahepatic portosystemic shunts. Interventional therapy was employed to occlude the shunt. During the follow-up, the intrahepatic tumor disappeared and no complications. Hence, to be able to differentiate such vascular anomalies, clinicians should be fairly acquainted with the normal ultrasonographic anatomical features in daily clinical work. Furthermore, increased disease awareness and advances in imaging equipment and technology are essential for CPSS diagnosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA