Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 577
Filtrar
1.
Clin Oral Investig ; 28(10): 532, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39298001

RESUMEN

OBJECTIVE: To evaluate the color change (ΔE) and fluorescence (FL) of resin composites after the consumption of beverages. MATERIALS AND METHODS: One hundred and sixty disc-shaped specimens (6 × 2 mm) of Filtek Z350 XT (FZX) and Forma (FOR) resin composites were randomized for use in devices by five volunteers who ingested 100 ml daily of red wine (RW), beer (BE), energy drink (ED) and water (WT) over 15 days. The data were collected from digital photographs and analyzed using the CIE-Lab and RGB scales to obtain ΔE and FL and statistics via two-way ANOVA (for ΔE) and ANOVA for repeated measures (for FL), α = 0.05. RESULTS: The highest ΔE values were obtained for FZX and FOR in the RW (ΔE = 10.5 for FZX and ΔE = 9.90 for FOR) and BE (ΔE = 6.3 for FZX and ΔE = 6.1 for FOR) drinks. For FL, there were different levels of change between the composites, with a much more significant reduction in FL intensity with RW. CONCLUSION: Beverages have the potential to stain the composites evaluated, especially alcoholic beverages. CLINICAL SIGNIFICANCE: Before carrying out an esthetic treatment with resin composites, it is ideal to investigate the types of drinks consumed by patients, for greater predictability of treatment.


Asunto(s)
Color , Resinas Compuestas , Vino , Resinas Compuestas/química , Humanos , Fluorescencia , Adulto , Bebidas Energéticas/análisis , Ensayo de Materiales , Cerveza , Bebidas , Femenino , Masculino , Propiedades de Superficie
2.
Dent Mater ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39107224

RESUMEN

OBJECTIVE: Nanozyme materials combine the advantages of natural enzymes and artificial catalysis, and have been widely applied in new technologies for dental materials and oral disease treatment. Based on the role of reactive oxygen species (ROS) and oxidative stress pathways in the occurrence and therapy of oral diseases, a comprehensive review was conducted on the methods and mechanisms of nanozymes and their dental materials in treating different oral diseases. METHODS: This review is based on literature surveys from PubMed and Web of Science databases, as well as reviews of relevant researches and publications on nanozymes in the therapy of oral diseases and oral tumors in international peer-reviewed journals. RESULTS: Given the unique function of nanozymes in the generation and elimination of ROS, they play an important role in the occurrence, development, and treatment of different oral diseases. The application of nanozymes in dental materials and oral disease treatment was introduced, including the latest advances in their use for dental caries, pulpitis, jaw osteomyelitis, periodontitis, oral mucosal diseases, temporomandibular joint disorders, and oral tumors. Future approaches were also summarized and proposed based on the characteristics of these diseases. SIGNIFICANCE: This review will guide biomedical researchers and oral clinicians to understand the mechanisms and applications of nanozymes in the therapy of oral diseases, promoting further development in the field of dental materials within the oral medication. It is anticipated that more suitable therapeutic agents or dental materials encapsulating nanozymes, specifically designed for the oral environment and simpler for clinical utilization, will emerge in the forthcoming future.

3.
J Allergy Clin Immunol Pract ; 12(9): 2280-2295, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39067854

RESUMEN

Allergic contact dermatitis is characterized by its appearance of red, raised and infiltrated, scaling or scabbed skin and intense pruritus, and distinguished from irritant contact dermatitis by its specific immune process and histopathology. Many contact allergens are low-molecular- weight chemicals including metals such as nickel, cobalt, and chromium, preservatives, and adhesives. When such materials are used internally in biomedical devices, they are similarly capable of causing sensitization and an inflammatory response. Sometimes, the reaction remains internal, and presents as swelling, pain, stiffness, decreased range of motion, and internal itching around the implant. Such reactions may, in some cases, also extend to include a localized or, rarely, systemic contact dermatitis indicative of the same process. This review will present an overview of reported skin and local internal reactions to orthopedic implants, which are the largest category of implanted internal metal devices. Immune reactions to smaller categories of medical appliances include cardiac devices and vascular stents, neuromodulation devices, diabetic appliances, Nuss bar surgery for pectus excavatum, and dental and spinal implants. We will review the available diagnostic tools, the consensus on interpretation, and reported strategies for treatment.


Asunto(s)
Dermatitis Alérgica por Contacto , Metales , Prótesis e Implantes , Humanos , Prótesis e Implantes/efectos adversos , Metales/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/etiología , Alérgenos/inmunología , Equipos y Suministros/efectos adversos
4.
Dent Mater ; 40(7): 1025-1030, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38755042

RESUMEN

OBJECTIVES: Resin composites may release bisphenol A (BPA) due to impurities present in the monomers. However, there is a lack of knowledge regarding the leaching characteristics of BPA from resin composites. Therefore, experimental resin composites were prepared with known amounts of BPA. The objective of this study was (1) to determine which amount of BPA initially present in the material leaches out in the short term and, (2) how this release is influenced by the resin composition. METHODS: BPA (0, 0.001, 0.01, or 0.1 wt%) was added to experimental resin composites containing 60 mol% BisGMA, BisEMA(3), or UDMA, respectively, as base monomer and 40 mol% TEGDMA as diluent monomer. Polymerized samples (n = 5) were immersed at 37 °C for 7 days in 1 mL of water, which was collected and refreshed daily. BPA release was quantified with UPLC-MS/MS after derivatization with pyridine-3-sulfonyl chloride. RESULTS: Between 0.47 to 0.67 mol% of the originally added BPA eluted from the resin composites after 7 days. Similar elution trends were observed irrespective of the base monomer. Two-way ANOVA showed a significant effect of the base monomer on BPA release, but the differences were small and not consistent. SIGNIFICANCE: The released amount of BPA was directly proportional to the quantity of BPA present in the resin composite as an impurity. BPA release was mainly diffusion-based, while polymer composition seemed to play a minor role. Our results underscore the importance for manufacturers only to use monomers of the highest purity in dental resin composites to avoid unnecessary BPA exposure in patients.


Asunto(s)
Compuestos de Bencidrilo , Resinas Compuestas , Fenoles , Fenoles/análisis , Fenoles/química , Compuestos de Bencidrilo/química , Resinas Compuestas/química , Ensayo de Materiales , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem , Poliuretanos/química , Ácidos Polimetacrílicos/química , Metacrilatos/química , Metacrilatos/análisis , Polietilenglicoles/química , Polimerizacion
5.
Saudi Dent J ; 36(1): 158-167, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38375379

RESUMEN

Introduction: Nanotechnology is the science and engineering of nanoparticles whose dimensions range from 1 to 100 nm. Nanoparticles have special characteristics like increased surface area, high reactivity, and enhanced mechanical, thermal, and optical properties that make them attractive for use in dental applications. However, the use of nanoparticles in dental materials can have toxic effects on the human body. The objective of this paper is to discuss the toxic effects of various nanoparticles in dental materials, their adverse effect on human health, and measures to overcome such effects. Objectives: Nanoparticles are used in the diagnosis, prevention, and treatment of oral diseases like dental caries, pulpo periodontal lesions, oral cancer, denture stomatitis, and candidiasis. Exposure to nanoparticles may occur to the dental professional, and the patient during procedures like restoration, finishing, and polishing. Such exposure to nanoparticles through inhalation, and ingestion causes toxic effects in the lungs, skin, brain, liver, and kidney. Proper risk assessment methods and preventive measures may help reduce these toxic effects to some extent. Significance: Toxic effects of nanoparticles that are released during dental procedures, their route of exposure, and the concentration at which nanoparticles can induce toxic effects on the human body are discussed in detail in this review. The paper also aims to create awareness among dental professionals, students, and patients regarding nanoparticle exposure and its adverse effects, and methods to prevent and overcome these effects. Currently, it is ignored or taken lightly by the stakeholders and this review may throw light.

6.
Front Chem ; 12: 1356029, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38406557

RESUMEN

Introduction: Polymethyl methacrylate is a polymer commonly used in clinical dentistry, including denture bases, occlusal splints and orthodontic retainers. Methods: To augment the polymethyl methacrylate-based dental appliances in counteracting dental caries, we designed a polymer blend film composed of polymethyl methacrylate and polyethylene oxide by solution casting and added sodium fluoride. Results: Polyethylene oxide facilitated the dispersion of sodium fluoride, decreased the surface average roughness, and positively influenced the hydrophilicity of the films. The blend film made of polymethyl methacrylate, polyethylene oxide and NaF with a mass ratio of 10: 1: 0.3 showed sustained release of fluoride ions and acceptable cytotoxicity. Antibacterial activity of all the films to Streptococcus mutans was negligible. Discussion: This study demonstrated that the polymer blends of polyethylene oxide and polymethyl methacrylate could realize the relatively steady release of fluoride ions with high biocompatibility. This strategy has promising potential to endow dental appliances with anti-cariogenicity.

7.
Braz. oral res. (Online) ; 38: e001, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1528143

RESUMEN

Abstract The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.

8.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1550094

RESUMEN

Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.


Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.

9.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1537767

RESUMEN

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Asunto(s)
Materiales Dentales , Pins Dentales
10.
Braz. oral res. (Online) ; 38: e028, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1557354

RESUMEN

Abstract Acidic pH can modify the properties of repair cements. In this study, volumetric change and solubility of the ready-to-use bioceramic repair cement Bio-C Repair (BCR, Angelus, Londrina, PR, Brazil) were evaluated after immersion in phosphate-buffered saline (PBS) (pH 7.0) or butyric acid (pH 4.5). Solubility was determined by the difference in initial and final mass using polyethylene tubes measuring 4 mm high and 6.70 mm in internal diameter that were filled with BCR and immersed in 7.5 mL of PBS or butyric acid for 7 days. The volumetric change was established by using bovine dentin tubes measuring 4 mm long with an internal diameter of 1.5 mm. The dentin tubes were filled with BCR at 37°C for 24 hours. Scanning was performed with micro-computed tomography (micro-CT; SkyScan 1176, Bruker, Kontich, Belgium) with a voxel size of 8.74 µm. Then, the specimens were immersed in 1.5 mL of PBS or butyric acid at and 37 °C for 7 days. After this period, a new micro-CT scan was performed. Bio-C Repair showed greater mass loss after immersion in butyric acid when compared with immersion in PBS (p<0.05). Bio-C Repair showed volumetric loss after immersion in butyric acid and increase in volume after immersion in PBS (p<0.05). The acidic pH influenced the solubility and dimensional stability of the Bio-C Repair bioceramic cement, promoting a higher percentage of solubility and decrease in volumetric values.

11.
Braz. oral res. (Online) ; 38: e044, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1557366

RESUMEN

Abstract The aim of this study was to identify and analyze the characteristics of the 100 most cited articles about dental sealants (DS) in dentistry. In September 2023, a search was performed in the Web of Science Core Collection (WoS-CC) database. The following information was extracted from each article: number and density of citations, year of publication, authorship, journal, impact factor, keywords, study design, theme, continent, country, and institution. The citations of the WoS-CC were compared with those of the Scopus and Google Scholar databases. The VOSviewer software was used to generate collaborative networks. The number of citations ranged from 33 to 205. The articles were published between 1961 and 2016. Buonocore MG (7%) was the most prominent author among the most cited. The Journal of the American Dental Association was the most frequent journal (25%) and Journal of Dental Research (7.6) had the highest impact factor. Most studies had interventional (41%) and laboratory (31%) designs, mainly addressing DS effectiveness in the prevention and control of dental caries (86%). There was a predominance of publications from North America (46%) and the USA was the country with the highest number of articles (44%). The most frequent institutions were the Centers for Disease Control and Prevention (USA) and the University of Rochester (USA) (6% each). "Retention" was the most frequent keyword. In conclusion, the 100 most cited articles were mostly interventional and laboratory studies, addressing the retention and efficacy of DS. Most of the articles were concentrated in North America and Europe, demonstrating a little collaboration from other continents.

12.
Braz. oral res. (Online) ; 38: e066, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1568980

RESUMEN

Abstract This study assessed the physicochemical and antibiofilm properties of white mineral trioxide aggregate (MTA) associated with 1 or 2% of farnesol. Setting time was evaluated based on ISO 6876/2012. Radiopacity was evaluated by radiographic analysis. pH was assessed after time intervals of 1, 3, 7, 14, 21, and 28 days. Solubility (% mass loss) and volumetric change (by micro-CT) of the cements were evaluated after immersion in distilled water. The presence of voids inside the materials was assessed by using micro-CT. Antibiofilm activity against Enterococcus faecalis was evaluated by crystal violet assay and the modified direct contact test performed with biofilm previously formed on bovine root dentin for 14 days. Data were submitted to ANOVA/Tukey tests with 5% significance level. The incorporation of farnesol into MTA increased its setting time, but decreased its solubility at 30 days and its volumetric loss in all periods (p < 0.05). Radiopacity and solubility after 7 days were similar among the materials (p > 0.05). The association of farnesol showed the highest pH value after 1 and 3 days (p < 0.05). The association of farnesol with MTA promoted a decrease in the presence of voids, and increased the antimicrobial activity on biofilm biomass of E. faecalis (p < 0.05). In conclusion, the addition of farnesol can be suggested to improve the antimicrobial properties and the consistency of MTA.

13.
Braz. dent. sci ; 27(2): 1-7, 2024. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1570168

RESUMEN

Objective: This study aimed to investigate of bioactive materials with specific properties, particularly highly plastic bioceramic cements. These materials are being studied extensively due to their potential to maintain pulp vitality and promote tissue regeneration. Material and Methods: Tooth discoloration induced by an experimental tricalcium silicate-based cement (EC) was evaluated and compared with that of Biodentine (BD) and white MTA-Angelus (MTA). Cavities were prepared on the lingual surfaces of thirty-two blocks of healthy bovine incisors. The blocks were chemically cleaned and then subjected to an initial color evaluation (CIELab values) using a spectrophotometer and randomly divided into three experimental groups (n=10); two additional blocks served as controls. After manipulation, the cements were placed in the cavities, which were subsequently restored with composite restorations. After another color measurement (baseline), they were immersed in bottles of distilled water; they were stored at 37 °C and 100% humidity for the entire test period. The color change (ΔE) was measured after 14, 30, 120 and 150 days. ANOVA and Tukey tests showed significant differences after 14 days (EC vs. MTA), 30 days (EC vs. BD) and 120/150 days (EC vs. BD/MTA) (p < 0.05). Results: All tested materials induced ΔE changes, with the EC group showing the least change at the end of the experiment (ΔE=4.08). Conclusion: EC induced less color change over a 5-month period and thus showed color stability over the entire period, whereas BD and MTA showed progressive discoloration. (AU)


Objetivo: O objetivo deste estudo foi investigar materiais bioativos com propriedades específicas, particularmente cimentos biocerâmicos altamente plásticos. Esses materiais estão sendo amplamente estudados devido ao seu potencial para manter a vitalidade da polpa e promover a regeneração dos tecidos. Material e Métodos: A descoloração dentária induzida por um cimento experimental à base de silicato tricálcico (CE) foi avaliada e comparada com a do Biodentine (BD) e do MTA-Angelus branco (MTA). Foram preparadas cavidades nas superfícies linguais de trinta e dois blocos de incisivos bovinos saudáveis. Os blocos foram quimicamente limpos e, em seguida, submetidos a uma avaliação inicial de cor (valores CIELab) usando um espectrofotômetro e divididos aleatoriamente em três grupos experimentais (n=10); dois blocos adicionais serviram como controles. Após a manipulação, os cimentos foram colocados nas cavidades, que foram posteriormente restauradas com compósito. Após outra medição de cor (valor de referência), eles foram imersos em frascos de água destilada; oram armazenados a 37 °C e 100% de umidade durante todo o período de teste. A alteração de cor (ΔE) foi medida após 14, 30, 120 e 150 dias. Os testes ANOVA e Tukey mostraram diferenças significativas após 14 dias (CE vs. MTA), 30 dias (CE vs. BD) e 120/150 dias (CE vs. BD/MTA) (p < 0,05). Resultados: Todos os materiais testados induziram alterações de ΔE, sendo que o grupo EC apresentou a menor alteração no final do experimento (ΔE=4,08). Conclusão: O EC induziu menos alterações de cor em um período de 5 meses e, portanto, apresentou estabilidade de cor durante todo o período, enquanto o BD e o MTA apresentaram descoloração progressiva.(AU)


Asunto(s)
Cemento de Silicato , Decoloración de Dientes , Materiales Biomédicos y Dentales , Cementos Dentales , Endodoncia
14.
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1550590

RESUMEN

ABSTRACT Objective: To guide professionals about the criteria for replacing amalgam restorations and inform them about the new guidelines regarding the use/indication of this (amalgam) material after the Minamata Convention - COP-4. Material and Methods: The articles were selected from the databases (PubMed, Scielo, Bireme), and relevant articles on the subject between the years 2003-2021 were selected. Recently, social media have been flooded with dental treatments that aim to perform restorations only with composite resins or other types of esthetic material and completely replace all dental amalgam restorations, irrespective of their time in place, size, and functionality. Results: Although improperly, it has been noted that this information reaches patients, and they are led to believe in the inaccurate data that is passed on, such as, for example, (that amalgam leads to) permanent contamination by mercury, causing systemic problems and the loss of the tooth. Conclusion: The "phase down" of amalgam in research and teaching has previously been observed in several countries worldwide; however, its use is still necessary given particular circumstances, which, theoretically, make it a material with exact indication.


Asunto(s)
Amalgama Dental/química , Materiales Dentales , Restauración Dental Permanente , Efectos Adversos a Largo Plazo , Estudios Longitudinales , Resinas Compuestas
15.
Biomedicines ; 11(11)2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38002093

RESUMEN

In craniofacial research and routine dental clinical procedures, multifunctional materials with antimicrobial properties are in constant demand. Ionic liquids (ILs) are one such multifunctional intelligent material. Over the last three decades, ILs have been explored for different biomedical applications due to their unique physical and chemical properties, high task specificity, and sustainability. Their stable physical and chemical characteristics and extremely low vapor pressure make them suitable for various applications. Their unique properties, such as density, viscosity, and hydrophilicity/hydrophobicity, may provide higher performance as a potential dental material. ILs have functionalities for optimizing dental implants, infiltrate materials, oral hygiene maintenance products, and restorative materials. They also serve as sensors for dental chairside usage to detect oral cancer, periodontal lesions, breath-based sobriety, and dental hard tissue defects. With further optimization, ILs might also make vital contributions to craniofacial regeneration, oral hygiene maintenance, oral disease prevention, and antimicrobial materials. This review explores the different advantages and properties of ILs as possible dental material.

16.
BMC Med Educ ; 23(1): 716, 2023 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-37784112

RESUMEN

BACKGROUND: Dental materials science is an important subject, but research on curriculum mapping in preclinical dental materials science courses is still scarce. The present study aimed to conduct a curriculum mapping in analysing elements and suggesting recommendations for an institutional dental materials science course. METHODS: Curriculum mapping was conducted for the Year 2 undergraduate dental materials science course (Bachelor of Dental Surgery programme) in a Malaysian dental school. Based on Harden's framework, the following steps were used to map the curriculum of the institutional dental materials science course: (1) scoping the task; (2) deciding the mapping format; (3) populating the windows, and (4) establishing the links. Two analysts reviewed the curriculum independently. Their respective analyses were compared, and discrepancies were discussed until reaching a consensus. A SWOT analysis was also conducted to evaluate the strengths, weaknesses, opportunities, and threats associated with the curriculum. RESULTS: Course learning outcomes, course contents, levels of cognitive and psychomotor competencies, learning opportunities, learning resources, learning locations, assessments, timetable, staff, curriculum management and students' information were successfully scoped from the institutional dental materials science course. The present curriculum's strengths included comprehensiveness, alignment with standards, adequate learning opportunities, well-defined assessment methods, and sufficient learning resources. However, the identified weaknesses were repetition in curriculum content, limited emphasis on the psychomotor domain, dependency on a single academic staff, and limited integration of technology. The SWOT analysis highlighted the opportunities for curriculum improvement, such as revising repetitive content, emphasising the psychomotor domain, and incorporating advanced teaching strategies and technology. CONCLUSIONS: The present dental materials science curriculum demonstrated several strengths with some areas for improvement. The findings suggested the need to revise and optimise the course content to address gaps and enhance student learning outcomes. Ongoing monitoring and evaluation are necessary to ensure the curriculum remains aligned with emerging trends and advancements in dental materials science.


Asunto(s)
Curriculum , Ciencia de los Materiales , Humanos , Aprendizaje , Estudios Longitudinales
17.
Materials (Basel) ; 16(18)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37763518

RESUMEN

This study aimed to evaluate the effects of surface treatments and resin cement on the adhesion of ceramic and ceramic-like materials to titanium. A total of 40 specimens (5 mm diameter) of each material (lithium disilicate glass ceramic (LDGC-IPS e.maxCAD), lithium silicate glass ceramic (LSGC-VITA Suprinity) and a polymer-infiltrated ceramic network (PICN-Vita Enamic)) were fabricated using CAD/CAM technologies. In total, 120 titanium (Ti) specimens were divided into 12 groups, and half of the titanium specimens were tribochemically coated using CoJet. The titanium and all-ceramic specimens were cemented using either Self-curing adhesive cement (SCAC-Panavia 21) or a Self-curing luting composite (SCLC-Multilink Hybrid Abutment). After 5000 cycles of thermal aging, the shear bond strength (SBS) test was conducted using a universal testing machine. The failure modes of the specimens were analyzed using stereomicroscopy, and additionally, the representative specimens were observed using Scanning Electron Microscopy. ANOVA was used for the statistical analysis (p < 0.05). The post-hoc Duncan test was used to determine significant differences between the groups. The mean SBS values (mean ± STD) ranged from 15 ± 2 MPa to 29 ± 6 MPa. Significantly higher SBS values were acquired when the titanium surface was tribochemically coated (p < 0.05). The SCLC showed higher SBS values compared to the SCAC. While the LDGC showed the highest SBS values, the PICN presented the lowest. The tribochemical coating on the cementation surfaces of the titanium increased the SBS values. The specimens cemented with the SCLC showed higher SBS values than those with the SCAC. Additionally, the SCLC cement revealed a more significant increase in SBS values when used with the LDGC. The material used for restoration has a high impact on SBS than those of the cement and surface conditioning.

18.
Braz. dent. j ; Braz. dent. j;34(4): 115-126, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520337

RESUMEN

Abstract This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.


Resumo Neste estudo avaliou-se propriedades físico-químicas e de superfície de um compósito universal pré-aquecido e comparado a um compósito convencional. Foram utilizados dois compósitos comerciais: Filtek Universal Restorative (UR); UR pré-aquecido (URH); Filtek Supreme (FS) e FS pré-aquecido (FSH). O teste de espessura de película (EP) (n = 10) foi feito usando duas placas de vidro sob compressão. A resistência à flexão (RF) e o módulo flexural (MF) foram avaliados por meio do teste de flexão de três pontos (n = 10). A tensão de contração de polimerização (TCP) foi avaliada em uma máquina de teste universal (n = 8). A largura da fenda (LF) entre o compósito e o molde foi medida em moldes metálicos polidos internamente (n = 10). O grau de conversão (GC) foi avaliado por espectroscopia de infravermelho com transformada de Fourier (n = 3). A morfologia das partículas de carga foi observada em microscopia eletrônica de varredura (MEV) e sua composição em EDX. Brilho superficial (BS) e rugosidade superficial (RS) foram avaliados antes e após escovação mecânica (n=10). Os resultados foram submetidos à ANOVA 2-fatores e as médias comparadas pelo teste de Tukey (α = 0,05). Menores valores médios de EP foram observados para os grupos pré-aquecidos quando comparados aos grupos não pré-aquecidos. URH e FSH apresentaram maiores valores médios de RF e MF quando comparados com UR e FS. Não foram observadas diferenças entre os grupos no teste TCP. A LF foi maior para os grupos UR e FS quando comparados com URH e FSH. O GC foi maior para os compósitos pré-aquecidos quando comparados aos não pré-aquecidos. A RS do compósito UR foi maior que o FS após a escovação mecânica, enquanto o BS foi maior para os grupos FS. Em conclusão, o compósito universal testado geralmente apresentou propriedades físico-químicas semelhantes em comparação ao compósito nanoparticulado e propriedades de superfície semelhantes ou ligeiramente inferiores. O pré-aquecimento melhorou ou manteve todas as propriedades avaliadas.

19.
Biomater Investig Dent ; 10(1): 2234400, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37456807

RESUMEN

Several in vitro studies utilizing 2-dimensional (2D) cell culture systems have linked 2-hydroxyethyl methacrylate (HEMA) with cytotoxic effects in oral mucosa and dental pulp cells. Although such studies are invaluable in dissecting the cellular and molecular effects of HEMA, there is a growing interest in the utilization of appropriate 3-dimensional (3D) models that mimic the structure of oral mucosa. Using a previously characterized 3D-organotypic co-culture model, this study aimed to investigate the cellular and molecular effects of HEMA on a 3D-co-culture model consisting of primary normal oral keratinocyte (NOK) grown directly on top of collagen I gel containing primary oral fibroblasts (NOF). The second aim was to examine the suitability of a 3D-co-culture system consisting of oral squamous cell carcinoma (OSCC) cells as a model system to investigate the biological effects of HEMA. We demonstrated that HEMA treatment led to reduced viability of NOK, NOF and OSCC-cell lines in 2D-culture. The keratinocytes in 3D-co-cultures of NOK and OSCC-cells reacted similarly with respect to cell proliferation and activation of autophagy flux, to HEMA treatment. Nevertheless, NOK was found to be more susceptible to apoptosis following HEMA treatment than OSCC in 3D-co-cultures. These results indicate that 3D-organotypic co-cultures of NOK might represent an appropriate model system for the investigation of the biological effects of HEMA and other dental biomaterials. Given the challenges in obtaining primary cultures of NOK and issues associated with their rapid differentiation in culture, the possible use of OSCC cells as an alternative to NOK for 3D models represents an area for future research.

20.
Antibiotics (Basel) ; 12(7)2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37508193

RESUMEN

(1) Background: The aim of this research was to investigate the antibacterial activity of dissolved silver from silver-coated titanium implants against Streptococcus mutans. (2) Methodology: Silver-coated titanium implant discs were immersed in 1.8 mL of brain heart infusion broth (BHIB) and incubated for 24 h in order to release the silver ions into the broth. The coating quality was confirmed via EDS, and the dissolved silver was measured via inductively coupled plasma mass spectrometry (ICP-MS). The experimental design used unconditioned broth (control) and broth conditioned with silver released from silver-coated titanium implants (n = 6). Regarding the antibacterial activity, isolated Streptococcus mutans was used. A turbidity test and lactate production test were performed to determine the effect of dissolved silver on bacterial growth in a suspension and biofilm formation. (3) Result: The results showed that the coating was successfully applied on the substrate. There was around 0.3 mg/L of silver released into the BHIB, and the turbidity of the control group was significantly higher than the treatment, with measured absorbance values of 1.4 and 0.8, respectively, indicating that the dissolved silver ions from the silver-coated titanium discs exhibited some degree of antibacterial activity by preventing the growth of Streptococcus mutans. However, the results of the antibiofilm activity test did not show any significant difference between the groups. (4) Conclusion: The dissolved silver from silver-coated titanium implants has an antibacterial activity but not a significant antimicrobial activity, indicating that the dissolved silver from silver-coated titanium abutments can significantly reduce the incidence of peri-implant mucositis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA