Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Materials (Basel) ; 17(9)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38730941

RESUMEN

To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.

2.
ACS Appl Mater Interfaces ; 14(18): 21474-21485, 2022 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-35486453

RESUMEN

Multiresponsive and high-performance flexible actuators with a simple configuration, high mechanical strength, and low-power consumption are highly desirable for soft robotics. Here, a novel mechanically robust and multiresponsive Ti3C2Tx MXene-based actuator with high actuation performance via dual-mechanism synergistic effect driven by the hygroexpansion of bacterial cellulose (BC) layer and the thermal expansion of biaxially oriented polypropylene (BOPP) layer is developed. The actuator is flexible and shows an ultrahigh tensile strength of 195 MPa. Unlike the conventional bimorph-structured actuators based on a single-mechanism, the actuator developed provides a favorable architecture for dual-mechanism synergism, resulting in exceptionally reversible actuation performance under electricity and near-infrared (NIR) light stimuli. Typically, the developed actuator can produce the largest bending angle (∼400°) at the lowest voltage (≤4 V) compared with that reported previously for single mechanism soft actuators. Furthermore, the actuator also can be driven by a NIR light at a 2 m distance, displaying an excellent long-distance photoresponsive property. Finally, various intriguing applications are demonstrated to show the great potential of the actuator for soft robotics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA