Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.932
Filtrar
Más filtros











Intervalo de año de publicación
1.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 627-634, 2024 Jun 25.
Artículo en Chino | MEDLINE | ID: mdl-38932551

RESUMEN

The simultaneous objectives of destroying tumor cells while protecting normal pelvic organs present a dual clinical and technical challenge within the realm of pelvic tumor radiotherapy. This article reviews the latest literatures, focusing on technological innovations in key aspects of radiotherapy such as positioning, planning, and delivery. These include positioning fixation techniques, organ-at-risk avoidance irradiation, non-coplanar irradiation techniques, as well as organ displacement protection and image-guided adaptive techniques. It summarizes and discusses the research progress made in the protection of critical organs during pelvic tumor radiotherapy. The paper emphasizes technological advancements in the protection of critical organs throughout the processes of radiotherapy positioning, planning, and implementation, aiming to provide references for further research on the protection of critical organs in the external irradiation treatment of pelvic tumors.


Asunto(s)
Órganos en Riesgo , Neoplasias Pélvicas , Humanos , Neoplasias Pélvicas/radioterapia , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Posicionamiento del Paciente , Pelvis/efectos de la radiación , Radioterapia/métodos , Radioterapia/efectos adversos , Protección Radiológica/métodos , Traumatismos por Radiación/prevención & control
2.
Biomed Phys Eng Express ; 10(4)2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38923907

RESUMEN

Objective: To summarize our institutional prostate stereotactic body radiation therapy (SBRT) experience using auto beam hold (ABH) technique for intrafractional prostate motion and assess ABH tolerance of 10-millimeter (mm) diameter.Approach: Thirty-two patients (160 fractions) treated using ABH technique between 01/2018 and 03/2021 were analyzed. During treatment, kV images were acquired every 20-degree gantry rotation to visualize 3-4 gold fiducials within prostate to track target motion. If the fiducial center fell outside the tolerance circle (diameter = 10 mm), beam was automatically turned off for reimaging and repositioning. Number of beam holds and couch translational movement magnitudes were recorded. Dosimetric differences from intrafractional motion were calculated by shifting planned isocenter.Main Results: Couch movement magnitude (mean ± SD) in vertical, longitudinal and lateral directions were -0.7 ± 2.5, 1.4 ± 2.9 and -0.1 ± 0.9 mm, respectively. For most fractions (77.5%), no correction was necessary. Number of fractions requiring one, two, or three corrections were 15.6%, 5.6% and 1.3%, respectively. Of the 49 corrections, couch shifts greater than 3 mm were seen primarily in the vertical (31%) and longitudinal (39%) directions; corresponding couch shifts greater than 5 mm occurred in 2% and 6% of cases. Dosimetrically, 100% coverage decreased less than 2% for clinical target volume (CTV) (-1 ± 2%) and less than 10% for PTV (-10 ± 6%). Dose to bladder, bowel and urethra tended to increase (Bladder: ΔD10%:184 ± 466 cGy, ΔD40%:139 ± 241 cGy, Bowel: ΔD1 cm3:54 ± 129 cGy; ΔD5 cm3:44 ± 116 cGy, Urethra: ΔD0.03 cm3:1 ± 1%). Doses to the rectum tended to decrease (Rectum: ΔD1 cm3:-206 ± 564 cGy, ΔD10%:-97 ± 426 cGy; ΔD20%:-50 ± 251 cGy).Significance: With the transition from conventionally fractionated intensity modulated radiation therapy to SBRT for localized prostate cancer treatment, it is imperative to ensure that dose delivery is spatially accurate for appropriate coverage to target volumes and limiting dose to surrounding organs. Intrafractional motion monitoring can be achieved using triggered imaging to image fiducial markers and ABH to allow for reimaging and repositioning for excessive motion.


Asunto(s)
Movimiento , Próstata , Neoplasias de la Próstata , Radiometría , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Próstata/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Marcadores Fiduciales , Movimiento (Física) , Fraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada/métodos , Vejiga Urinaria , Recto , Órganos en Riesgo/efectos de la radiación
3.
Radiat Oncol ; 19(1): 69, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822385

RESUMEN

BACKGROUND: Multiple artificial intelligence (AI)-based autocontouring solutions have become available, each promising high accuracy and time savings compared with manual contouring. Before implementing AI-driven autocontouring into clinical practice, three commercially available CT-based solutions were evaluated. MATERIALS AND METHODS: The following solutions were evaluated in this work: MIM-ProtégéAI+ (MIM), Radformation-AutoContour (RAD), and Siemens-DirectORGANS (SIE). Sixteen organs were identified that could be contoured by all solutions. For each organ, ten patients that had manually generated contours approved by the treating physician (AP) were identified, totaling forty-seven different patients. CT scans in the supine position were acquired using a Siemens-SOMATOMgo 64-slice helical scanner and used to generate autocontours. Physician scoring of contour accuracy was performed by at least three physicians using a five-point Likert scale. Dice similarity coefficient (DSC), Hausdorff distance (HD) and mean distance to agreement (MDA) were calculated comparing AI contours to "ground truth" AP contours. RESULTS: The average physician score ranged from 1.00, indicating that all physicians reviewed the contour as clinically acceptable with no modifications necessary, to 3.70, indicating changes are required and that the time taken to modify the structures would likely take as long or longer than manually generating the contour. When averaged across all sixteen structures, the AP contours had a physician score of 2.02, MIM 2.07, RAD 1.96 and SIE 1.99. DSC ranged from 0.37 to 0.98, with 41/48 (85.4%) contours having an average DSC ≥ 0.7. Average HD ranged from 2.9 to 43.3 mm. Average MDA ranged from 0.6 to 26.1 mm. CONCLUSIONS: The results of our comparison demonstrate that each vendor's AI contouring solution exhibited capabilities similar to those of manual contouring. There were a small number of cases where unusual anatomy led to poor scores with one or more of the solutions. The consistency and comparable performance of all three vendors' solutions suggest that radiation oncology centers can confidently choose any of the evaluated solutions based on individual preferences, resource availability, and compatibility with their existing clinical workflows. Although AI-based contouring may result in high-quality contours for the majority of patients, a minority of patients require manual contouring and more in-depth physician review.


Asunto(s)
Inteligencia Artificial , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
4.
Radiat Prot Dosimetry ; 200(9): 842-847, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38828501

RESUMEN

Imaging parameters, frequencies and resulting patient organ doses in treatments of prostate cancer were assessed in Finnish radiotherapy centres. Based on a questionnaire to the clinics, Monte Carlo method was used to estimate organ doses in International Commission on Radiological Protection standard phantom for prostate, bladder, rectum and femoral head. The results show that doses from cone beam computed tomography imaging have reduced compared to earlier studies and are between 3.6 and 34.5 mGy per image for the above-mentioned organs and for normal sized patients. There still is room for further optimization of the patient exposure, as many centres use the default imaging parameters, and the length of the imaged region may not be optimal for the purpose.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Método de Montecarlo , Posicionamiento del Paciente , Neoplasias de la Próstata , Dosificación Radioterapéutica , Humanos , Masculino , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Finlandia , Dosis de Radiación , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Recto/efectos de la radiación , Vejiga Urinaria/efectos de la radiación , Vejiga Urinaria/diagnóstico por imagen , Cabeza Femoral/efectos de la radiación , Próstata/efectos de la radiación , Próstata/diagnóstico por imagen
5.
Technol Cancer Res Treat ; 23: 15330338241252622, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38845139

RESUMEN

Purpose: The aim of this matched-pair cohort study was to evaluate the potential of intensity-modulated proton therapy (IMPT) for sparring of the pelvic bone marrow and thus reduction of hematotoxicity compared to intensity-modulated photon radiotherapy (IMRT) in the setting of postoperative irradiation of gynaecological malignancies. Secondary endpoint was the assessment of predictive parameters for the occurrence of sacral insufficiency fractures (SIF) when applying IMPT. Materials and Methods: Two cohorts were analyzed consisting of 25 patients each. Patients were treated with IMPT compared with IMRT and had uterine cervical (n = 8) or endometrial cancer (n = 17). Dose prescription, patient age, and diagnosis were matched. Dosimetric parameters delivered to the whole pelvic skeleton and subsites (ilium, lumbosacral, sacral, and lower pelvis) and hematological toxicity were evaluated. MRI follow-up for evaluation of SIF was only available for the IMPT group. Results: In the IMPT group, integral dose to the pelvic skeleton was significantly lower (23.4GyRBE vs 34.3Gy; p < 0.001), the average V5Gy, V10Gy, and V20Gy were reduced by 40%, 41%, and 28%, respectively, compared to the IMRT group (p < 0.001). In particular, for subsites ilium and lower pelvis, the low dose volume was significantly lower. Hematotoxicity was significantly more common in the IMRT group (80% vs 32%; p = 0009), especially hematotoxicity ≥ CTCAE II (36% vs 8%; p = 0.037). No patient in the IMPT group experienced hematotoxicity > CTCAE II. In the IMPT cohort, 32% of patients experienced SIF. Overall SIF occurred more frequently with a total dose of 50.4 GyRBE (37.5%) compared to 45 GyRBE (22%). No significant predictive dose parameters regarding SIF could be detected aside from a trend regarding V50Gy to the lumbosacral subsite. Conclusion: Low-dose exposure to the pelvic skeleton and thus hematotoxicity can be significantly reduced by using IMPT compared to a matched photon cohort. Sacral insufficiency fracture rates appear similar to reported rates for IMRT in the literature.


Asunto(s)
Médula Ósea , Neoplasias de los Genitales Femeninos , Terapia de Protones , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Humanos , Femenino , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Médula Ósea/efectos de la radiación , Médula Ósea/patología , Persona de Mediana Edad , Anciano , Neoplasias de los Genitales Femeninos/radioterapia , Adulto , Planificación de la Radioterapia Asistida por Computador , Órganos en Riesgo/efectos de la radiación , Tratamientos Conservadores del Órgano/métodos
6.
Comput Biol Med ; 177: 108637, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38824789

RESUMEN

Radiotherapy is a preferred treatment for brain metastases, which kills cancer cells via high doses of radiation meanwhile hardly avoiding damage to surrounding healthy cells. Therefore, the delineation of organs-at-risk (OARs) is vital in treatment planning to minimize radiation-induced toxicity. However, the following aspects make OAR delineation a challenging task: extremely imbalanced organ sizes, ambiguous boundaries, and complex anatomical structures. To alleviate these challenges, we imitate how specialized clinicians delineate OARs and present a novel cascaded multi-OAR segmentation framework, called OAR-SegNet. OAR-SegNet comprises two distinct levels of segmentation networks: an Anatomical-Prior-Guided network (APG-Net) and a Point-Cloud-Guided network (PCG-Net). Specifically, APG-Net handles segmentation for all organs, where multi-view segmentation modules and a deep prior loss are designed under the guidance of prior knowledge. After APG-Net, PCG-Net refines small organs through the mini-segmentation and the point-cloud alignment heads. The mini-segmentation head is further equipped with the deep prior feature. Extensive experiments were conducted to demonstrate the superior performance of the proposed method compared to other state-of-the-art medical segmentation methods.


Asunto(s)
Neoplasias Encefálicas , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Procesamiento de Imagen Asistido por Computador/métodos
7.
Technol Cancer Res Treat ; 23: 15330338241260646, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38841792

RESUMEN

OBJECTIVE: The purpose of this research was to compare two treatment techniques for oropharyngeal cancers: conventional linac-based static intensity-modulated radiotherapy (sIMRT) and helical tomotherapy (HT). The study examined several parameters, including target coverage, organs at risk, integral dose, and beam on time. Additionally, the study evaluated the doses to the parotid, temporomandibular joint, and pharyngeal constrictor muscles, which are important for swallowing. METHOD: The present study retrospectively analyzed the data of 13 patients with oropharyngeal cancer who underwent radiotherapy between 2019 and 2021. The treatment plans for each patient were regenerated using both sIMRT and HT treatment planning systems with the sequential boost method. The techniques were evaluated and compared based on dose-volume histogram, homogeneity index, and conformity index parameters. The target coverage and organs at risk were statistically compared for two techniques. Additionally, the doses received by the healthy tissue volume were obtained for integral dose evaluation. The beam on time for each technique was assessed. RESULTS: When considering planning target volume evaluation, there was no difference in Dmeans between the two techniques and sIMRT demonstrated higher D2% values compared to the HT. The HT technique had better results for all organs at risk, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle. As for integral dose, it has been shown that the sIMRT technique provides better protection compared to HT. In addition, the beam on time was also longer with the HT technique. CONCLUSION: Both techniques may provide optimal target coverage for patients with oropharyngeal cancer. HT conferred notable advantages, especially with regard to critical structures implicated in swallowing, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle, in comparison to sIMRT.


Asunto(s)
Órganos en Riesgo , Neoplasias Orofaríngeas , Glándula Parótida , Músculos Faríngeos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Articulación Temporomandibular , Humanos , Neoplasias Orofaríngeas/radioterapia , Glándula Parótida/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Articulación Temporomandibular/efectos de la radiación , Masculino , Estudios Retrospectivos , Músculos Faríngeos/efectos de la radiación , Femenino , Anciano , Persona de Mediana Edad
8.
World J Surg Oncol ; 22(1): 147, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831328

RESUMEN

BACKGROUND: Radio(chemo)therapy is often required in pelvic malignancies (cancer of the anus, rectum, cervix). Direct irradiation adversely affects ovarian and endometrial function, compromising the fertility of women. While ovarian transposition is an established method to move the ovaries away from the radiation field, surgical procedures to displace the uterus are investigational. This study demonstrates the surgical options for uterine displacement in relation to the radiation dose received.  METHODS: The uterine displacement techniques were carried out sequentially in a human female cadaver to demonstrate each procedure step by step and assess the uterine positions with dosimetric CT scans in a hybrid operating room. Two treatment plans (anal and rectal cancer) were simulated on each of the four dosimetric scans (1. anatomical position, 2. uterine suspension of the round ligaments to the abdominal wall 3. ventrofixation of the uterine fundus at the umbilical level, 4. uterine transposition). Treatments were planned on Eclipse® System (Varian Medical Systems®,USA) using Volumetric Modulated Arc Therapy. Data about maximum (Dmax) and mean (Dmean) radiation dose received and the volume receiving 14 Gy (V14Gy) were collected. RESULTS: All procedures were completed without technical complications. In the rectal cancer simulation with delivery of 50 Gy to the tumor, Dmax, Dmean and V14Gy to the uterus were respectively 52,8 Gy, 34,3 Gy and 30,5cc (1), 31,8 Gy, 20,2 Gy and 22.0cc (2), 24,4 Gy, 6,8 Gy and 5,5cc (3), 1,8 Gy, 0,6 Gy and 0,0cc (4). For anal cancer, delivering 64 Gy to the tumor respectively 46,7 Gy, 34,8 Gy and 31,3cc (1), 34,3 Gy, 20,0 Gy and 21,5cc (2), 21,8 Gy, 5,9 Gy and 2,6cc (3), 1,4 Gy, 0,7 Gy and 0,0cc (4). CONCLUSIONS: The feasibility of several uterine displacement procedures was safely demonstrated. Increasing distance to the radiation field requires more complex surgical interventions to minimize radiation exposure. Surgical strategy needs to be tailored to the multidisciplinary treatment plan, and uterine transposition is the most technically complex with the least dose received.


Asunto(s)
Cadáver , Preservación de la Fertilidad , Neoplasias Pélvicas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Útero , Humanos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Preservación de la Fertilidad/métodos , Útero/efectos de la radiación , Útero/cirugía , Útero/patología , Neoplasias Pélvicas/radioterapia , Neoplasias Pélvicas/cirugía , Neoplasias Pélvicas/patología , Radioterapia de Intensidad Modulada/métodos , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos
9.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38861951

RESUMEN

Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Pulmón , Imagen por Resonancia Magnética , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Pulmón/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada Cuatridimensional/métodos , Masculino , Femenino , Radioterapia Guiada por Imagen/métodos , Contencion de la Respiración , Anciano , Persona de Mediana Edad , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo
10.
Radiat Oncol ; 19(1): 75, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38886727

RESUMEN

BACKGROUND AND PURPOSE: Rare but severe toxicities of the optic apparatus have been observed after treatment of intracranial tumours with proton therapy. Some adverse events have occurred at unusually low dose levels and are thus difficult to understand considering dose metrics only. When transitioning from double scattering to pencil beam scanning, little consideration was given to increased dose rates observed with the latter delivery paradigm. We explored if dose rate related metrics could provide additional predicting factors for the development of late visual toxicities. MATERIALS AND METHODS: Radiation-induced intracranial visual pathway lesions were delineated on MRI for all index cases. Voxel-wise maximum dose rate (MDR) was calculated for 2 patients with observed optic nerve toxicities (CTCAE grade 3 and 4), and 6 similar control cases. Additionally, linear energy transfer (LET) related dose enhancing metrics were investigated. RESULTS: For the index cases, which developed toxicities at low dose levels (mean, 50 GyRBE), some dose was delivered at higher instantaneous dose rates. While optic structures of non-toxicity cases were exposed to dose rates of up to 1 to 3.2 GyRBE/s, the pre-chiasmatic optic nerves of the 2 toxicity cases were exposed to dose rates above 3.7 GyRBE/s. LET-related metrics were not substantially different between the index and non-toxicity cases. CONCLUSIONS: Our observations reveal large variations in instantaneous dose rates experienced by different volumes within our patient cohort, even when considering the same indications and beam arrangement. High dose rate regions are spatially overlapping with the radiation induced toxicity areas in the follow up images. At this point, it is not feasible to establish causality between exposure to high dose rates and the development of late optic apparatus toxicities due to the low incidence of injury.


Asunto(s)
Neoplasias Encefálicas , Terapia de Protones , Traumatismos por Radiación , Dosificación Radioterapéutica , Humanos , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Neoplasias Encefálicas/radioterapia , Femenino , Masculino , Persona de Mediana Edad , Adulto , Traumatismos por Radiación/etiología , Anciano , Nervio Óptico/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Relación Dosis-Respuesta en la Radiación
11.
Technol Cancer Res Treat ; 23: 15330338241259633, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38887092

RESUMEN

PURPOSE: We report a dosimetric study in whole breast irradiation (WBI) of plan robustness evaluation against position error with two radiation techniques: tangential intensity-modulated radiotherapy (T-IMRT) and multi-angle IMRT (M-IMRT). METHODS: Ten left-sided patients underwent WBI were selected. The dosimetric characteristics, biological evaluation and plan robustness were evaluated. The plan robustness quantification was performed by calculating the dose differences (Δ) of the original plan and perturbed plans, which were recalculated by introducing a 3-, 5-, and 10-mm shift in 18 directions. RESULTS: M-IMRT showed better sparing of high-dose volume of organs at risk (OARs), but performed a larger low-dose irradiation volume of normal tissue. The greater shift worsened plan robustness. For a 10-mm perturbation, greater dose differences were observed in T-IMRT plans in nearly all directions, with higher ΔD98%, ΔD95%, and ΔDmean of CTV Boost and CTV. A 10-mm shift in inferior (I) direction induced CTV Boost in T-IMRT plans a 1.1 (ΔD98%), 1.1 (ΔD95%), and 1.7 (ΔDmean) times dose differences greater than dose differences in M-IMRT plans. For CTV Boost, shifts in the right (R) and I directions generated greater dose differences in T-IMRT plans, while shifts in left (L) and superior (S) directions generated larger dose differences in M-IMRT plans. For CTV, T-IMRT plans showed higher sensitivity to a shift in the R direction. M-IMRT plans showed higher sensitivity to shifts in L, S, and I directions. For OARs, negligible dose differences were found in V20 of the lungs and heart. Greater ΔDmax of the left anterior descending artery (LAD) was seen in M-IMRT plans. CONCLUSION: We proposed a plan robustness evaluation method to determine the beam angle against position uncertainty accompanied by optimal dose distribution and OAR sparing.


Asunto(s)
Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Neoplasias de Mama Unilaterales , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Femenino , Órganos en Riesgo/efectos de la radiación , Neoplasias de Mama Unilaterales/radioterapia , Neoplasias de la Mama/radioterapia , Radiometría/métodos , Persona de Mediana Edad
12.
JCO Clin Cancer Inform ; 8: e2300174, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38870441

RESUMEN

PURPOSE: The quality of radiotherapy auto-segmentation training data, primarily derived from clinician observers, is of utmost importance. However, the factors influencing the quality of clinician-derived segmentations are poorly understood; our study aims to quantify these factors. METHODS: Organ at risk (OAR) and tumor-related segmentations provided by radiation oncologists from the Contouring Collaborative for Consensus in Radiation Oncology data set were used. Segmentations were derived from five disease sites: breast, sarcoma, head and neck (H&N), gynecologic (GYN), and GI. Segmentation quality was determined on a structure-by-structure basis by comparing the observer segmentations with an expert-derived consensus, which served as a reference standard benchmark. The Dice similarity coefficient (DSC) was primarily used as a metric for the comparisons. DSC was stratified into binary groups on the basis of structure-specific expert-derived interobserver variability (IOV) cutoffs. Generalized linear mixed-effects models using Bayesian estimation were used to investigate the association between demographic variables and the binarized DSC for each disease site. Variables with a highest density interval excluding zero were considered to substantially affect the outcome measure. RESULTS: Five hundred seventy-four, 110, 452, 112, and 48 segmentations were used for the breast, sarcoma, H&N, GYN, and GI cases, respectively. The median percentage of segmentations that crossed the expert DSC IOV cutoff when stratified by structure type was 55% and 31% for OARs and tumors, respectively. Regression analysis revealed that the structure being tumor-related had a substantial negative impact on binarized DSC for the breast, sarcoma, H&N, and GI cases. There were no recurring relationships between segmentation quality and demographic variables across the cases, with most variables demonstrating large standard deviations. CONCLUSION: Our study highlights substantial uncertainty surrounding conventionally presumed factors influencing segmentation quality relative to benchmarks.


Asunto(s)
Teorema de Bayes , Benchmarking , Oncólogos de Radiación , Humanos , Benchmarking/métodos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias/epidemiología , Neoplasias/radioterapia , Órganos en Riesgo , Masculino , Oncología por Radiación/normas , Oncología por Radiación/métodos , Demografía , Variaciones Dependientes del Observador
13.
J Egypt Natl Canc Inst ; 36(1): 22, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38910202

RESUMEN

BACKGROUND: Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100). METHODS: The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm2 field size at constant source to surface distance (SSD) of 80 cm. RESULTS: The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor. CONCLUSION: It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.


Asunto(s)
Radioisótopos de Cobalto , Fantasmas de Imagen , Dosificación Radioterapéutica , Dosimetría Termoluminiscente , Humanos , Dosimetría Termoluminiscente/métodos , Agua , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias/radioterapia , Dosis de Radiación , Órganos en Riesgo/efectos de la radiación
14.
PLoS One ; 19(6): e0304771, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38885241

RESUMEN

Organ segmentation has become a preliminary task for computer-aided intervention, diagnosis, radiation therapy, and critical robotic surgery. Automatic organ segmentation from medical images is a challenging task due to the inconsistent shape and size of different organs. Besides this, low contrast at the edges of organs due to similar types of tissue confuses the network's ability to segment the contour of organs properly. In this paper, we propose a novel convolution neural network based uncertainty-driven boundary-refined segmentation network (UDBRNet) that segments the organs from CT images. The CT images are segmented first and produce multiple segmentation masks from multi-line segmentation decoder. Uncertain regions are identified from multiple masks and the boundaries of the organs are refined based on uncertainty data. Our method achieves remarkable performance, boasting dice accuracies of 0.80, 0.95, 0.92, and 0.94 for Esophagus, Heart, Trachea, and Aorta respectively on the SegThor dataset, and 0.71, 0.89, 0.85, 0.97, and 0.97 for Esophagus, Spinal Cord, Heart, Left-Lung, and Right-Lung respectively on the LCTSC dataset. These results demonstrate the superiority of our uncertainty-driven boundary refinement technique over state-of-the-art segmentation networks such as UNet, Attention UNet, FC-denseNet, BASNet, UNet++, R2UNet, TransUNet, and DS-TransUNet. UDBRNet presents a promising network for more precise organ segmentation, particularly in challenging, uncertain conditions. The source code of our proposed method will be available at https://github.com/riadhassan/UDBRNet.


Asunto(s)
Redes Neurales de la Computación , Órganos en Riesgo , Tomografía Computarizada por Rayos X , Humanos , Incertidumbre , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Pulmón/diagnóstico por imagen
15.
Acta Oncol ; 63: 448-455, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899392

RESUMEN

BACKGROUND: Robust optimization has been suggested as an approach to reduce the irradiated volume in lung Stereotactic Body Radiation Therapy (SBRT). We performed a retrospective planning study to investigate the potential benefits over Planning Target Volume (PTV)-based planning. MATERIAL AND METHODS: Thirty-nine patients had additional plans using robust optimization with 5-mm isocenter shifts of the Gross Tumor Volume (GTV) created in addition to the PTV-based plan used for treatment. The optimization included the mid-position phase and the extreme breathing phases of the 4D-CT planning scan. The plans were compared for tumor coverage, isodose volumes, and doses to Organs At Risk (OAR). Additionally, we evaluated both plans with respect to observed tumor motion using the peak tumor motion seen on the planning scan and cone-beam CTs. RESULTS: Statistically significant reductions in irradiated isodose volumes and doses to OAR were achieved with robust optimization, while preserving tumor dose. The reductions were largest for the low-dose volumes and reductions up to 188 ccm was observed. The robust evaluation based on observed peak tumor motion showed comparable target doses between the two planning methods. Accumulated mean GTV-dose was increased by a median of 4.46 Gy and a non-significant increase of 100 Monitor Units (MU) was seen in the robust optimized plans. INTERPRETATION: The robust plans required more time to prepare, and while it might not be a feasible planning strategy for all lung SBRT patients, we suggest it might be useful for selected patients.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Órganos en Riesgo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Humanos , Radiocirugia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada de Haz Cónico , Masculino , Fotones/uso terapéutico , Femenino , Anciano
16.
Acta Oncol ; 63: 477-481, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899395

RESUMEN

BACKGROUND: Deep learning (DL) models for auto-segmentation in radiotherapy have been extensively studied in retrospective and pilot settings. However, these studies might not reflect the clinical setting. This study compares the use of a clinically implemented in-house trained DL segmentation model for breast cancer to a previously performed pilot study to assess possible differences in performance or acceptability. MATERIAL AND METHODS: Sixty patients with whole breast radiotherapy, with or without an indication for locoregional radiotherapy were included. Structures were qualitatively scored by radiotherapy technologists and radiation oncologists. Quantitative evaluation was performed using dice-similarity coefficient (DSC), 95th percentile of Hausdorff Distance (95%HD) and surface DSC (sDSC), and time needed for generating, checking, and correcting structures was measured. RESULTS: Ninety-three percent of all contours in clinic were scored as clinically acceptable or usable as a starting point, comparable to 92% achieved in the pilot study. Compared to the pilot study, no significant changes in time reduction were achieved for organs at risks (OARs). For target volumes, significantly more time was needed compared to the pilot study for patients including lymph node levels 1-4, although time reduction was still 33% compared to manual segmentation. Almost all contours have better DSC and 95%HD than inter-observer variations. Only CTVn4 scored worse for both metrics, and the thyroid had a higher 95%HD value. INTERPRETATION: The use of the DL model in clinical practice is comparable to the pilot study, showing high acceptability rates and time reduction.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Humanos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/patología , Femenino , Proyectos Piloto , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Estudios Retrospectivos , Persona de Mediana Edad
17.
Sci Rep ; 14(1): 14347, 2024 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-38907042

RESUMEN

In breast cancer radiation therapy, minimizing radiation-related risks and toxicity is vital for improving life expectancy. Tailoring radiotherapy techniques and treatment positions can reduce radiation doses to normal organs and mitigate treatment-related toxicity. This study entailed a dosimetric comparison of six different external beam whole-breast irradiation techniques in both supine and prone positions. We selected fourteen breast cancer patients, generating six treatment plans in both positions per patient. We assessed target coverage and organs at risk (OAR) doses to evaluate the impact of treatment techniques and positions. Excess absolute risk was calculated to estimate potential secondary cancer risk in the contralateral breast, ipsilateral lung, and contralateral lung. Additionally, we analyzed the distance between the target volume and OARs (heart and ipsilateral lung) while considering the treatment position. The results indicate that prone positioning lowers lung exposure in X-ray radiotherapy. However, particle beam therapies (PBTs) significantly reduce the dose to the heart and ipsilateral lung regardless of the patient's position. Notably, negligible differences were observed between arc-delivery and static-delivery PBTs in terms of target conformity and OAR sparing. This study provides critical dosimetric evidence to facilitate informed decision-making regarding treatment techniques and positions.


Asunto(s)
Neoplasias de la Mama , Órganos en Riesgo , Dosificación Radioterapéutica , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Posición Prona , Posición Supina , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Posicionamiento del Paciente/métodos , Pulmón/efectos de la radiación , Persona de Mediana Edad , Radioterapia de Intensidad Modulada/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Corazón/efectos de la radiación
18.
In Vivo ; 38(4): 1712-1718, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38936930

RESUMEN

BACKGROUND/AIM: Intensity-modulated radiation therapy can deliver a highly conformal dose to a target while minimizing the dose to the organs at risk (OARs). Delineating the contours of OARs is time-consuming, and various automatic contouring software programs have been employed to reduce the delineation time. However, some software operations are manual, and further reduction in time is possible. This study aimed to automate running atlas-based auto-segmentation (ABAS) and software operations using a scripting function, thereby reducing work time. MATERIALS AND METHODS: Dice coefficient and Hausdorff distance were used to determine geometric accuracy. The manual delineation, automatic delineation, and modification times were measured. While modifying the contours, the degree of subjective correction was rated on a four-point scale. RESULTS: The model exhibited generally good geometric accuracy. However, some OARs, such as the chiasm, optic nerve, retina, lens, and brain require improvement. The average contour delineation time was reduced from 57 to 29 min (p<0.05). The subjective revision degree results indicated that all OARs required minor modifications; only the submandibular gland, thyroid, and esophagus were rated as modified from scratch. CONCLUSION: The ABAS model and scripted automation in head and neck cancer reduced the work time and software operations. The time can be further reduced by improving contour accuracy.


Asunto(s)
Neoplasias de Cabeza y Cuello , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Programas Informáticos , Humanos , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Dosificación Radioterapéutica , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
19.
Radiat Oncol ; 19(1): 80, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918828

RESUMEN

INTRODUCTION: Magnetic resonance guided radiotherapy (MRgRT) allows daily adaptation of treatment plans to compensate for positional changes of target volumes and organs at risk (OARs). However, current adaptation times are relatively long and organ movement occurring during the adaptation process might offset the benefit gained by adaptation. The aim of this study was to evaluate the dosimetric impact of these intrafractional changes. Additionally, a method to predict the extent of organ movement before the first treatment was evaluated in order to have the possibility to compensate for them, for example by adding additional margins to OARs. MATERIALS & METHODS: Twenty patients receiving adaptive MRgRT for treatment of abdominal lesions were retrospectively analyzed. Magnetic resonance (MR) images acquired at the start of adaptation and immediately before irradiation were used to calculate adapted and pre-irradiation dose in OARs directly next to the planning target volume. The extent of organ movement was determined on MR images acquired during simulation sessions and adaptive treatments, and their agreement was evaluated. Correlation between the magnitude of organ movement during simulation and the duration of simulation session was analyzed in order to assess whether organ movement might be relevant even if the adaptation process could be accelerated in the future. RESULTS: A significant increase in dose constraint violations was observed from adapted (6.9%) to pre-irradiation (30.2%) dose distributions. Overall, OAR dose increased significantly by 4.3% due to intrafractional organ movement. Median changes in organ position of 7.5 mm (range 1.5-10.5 mm) were detected within a median time of 17.1 min (range 1.6-28.7 min). Good agreement was found between the range of organ movement during simulation and adaptation (66.8%), especially if simulation sessions were longer and multiple MR images were acquired. No correlation was determined between duration of simulation sessions and magnitude of organ movement. CONCLUSION: Intrafractional organ movement can impact dose distributions and lead to violations of OAR tolerance doses, which impairs the benefit of daily on-table plan adaptation. By application of simulation images, the extent of intrafractional organ movement can be predicted, which possibly allows to compensate for them.


Asunto(s)
Imagen por Resonancia Magnética , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Humanos , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Órganos en Riesgo/efectos de la radiación , Imagen por Resonancia Magnética/métodos , Neoplasias Abdominales/radioterapia , Neoplasias Abdominales/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Anciano , Radioterapia de Intensidad Modulada/métodos , Movimiento , Fraccionamiento de la Dosis de Radiación
20.
Asian Pac J Cancer Prev ; 25(5): 1515-1528, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38809623

RESUMEN

PURPOSE: The current research compared radiobiological and dosimetric results for simultaneous integrated boost (SIB) plans employing RapidArc and IMRT planning procedures in oropharyngeal cancer from head-and-neck cancer (HNC) patients. MATERIALS AND METHODS: The indigenously developed Python-based software was used in this study for generation and analysis. Twelve patients with forty-eight total plans with SIB were planned using Rapid arc (2 and 3 arcs) and IMRT (7 and 9 fields) and compared with radiobiological models Lyman, Kutcher, Burman (LKB) and EUD (Equivalent Uniform Dose) along with physical index such as homogeneity index(HI), conformity index(CI) of target volumes. RESULTS: These models' inputs are the dose-volume histograms (DVHs) calculated by the treatment planning system (TPS). The values obtained vary from one model to the other for the same technique and patient. The maximum dose to the brainstem and spinal cord and the mean dose to the parotids were analysed both dosimetrically and radiobiologically, such as the LKB model effective volume, equivalent uniform dose, EUD-based normal tissue complication probability, and normal tissue integral dose. The mean and max dose to target volume with conformity, homogeneity index, tumor control probability compared with treatment times, and monitor units. CONCLUSION: Rapid arc (3 arcs) resulted in significantly better OAR sparing, dose homogeneity, and conformity. The findings indicate that the rapid arc plan has improved dose distribution in the target volume compared with IMRT, but the tumor control probability obtained for the two planning methods, Rapid arc (3 arcs) and IMRT (7 fields), are similar. The treatment time and monitor units for the Rapid arc (3 arcs) were superior to other planning methods and considered to be standard in head & neck radiotherapy.


Asunto(s)
Órganos en Riesgo , Neoplasias Orofaríngeas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Orofaríngeas/radioterapia , Neoplasias Orofaríngeas/patología , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría/métodos , Radiobiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA