Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 586
Filtrar
1.
J Refract Surg ; 40(10): e716-e723, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39387378

RESUMEN

PURPOSE: To assess the visual outcomes in patients with cataract implanted with a small-aperture intraocular lens (IOL) in eyes with aberrated corneas. METHODS: This prospective, non-interventional, single-center clinical study was conducted at Singapore National Eye Centre, Singapore. Twenty-one patients with aberrated corneas had IC-8 IOL (Bausch & Lomb, Inc) implantation. An aberrated cornea was defined as from natural causes: keratoconus (n = 1, 4.8%), high coma (n = 2, 9.5%), corneal scar (n = 1, 4.8%), or iatrogenic causes: keratorefractive procedure (n = 17, 86%). Uncorrected and corrected visual acuities were measured at distance (600 cm) (UDVA and CDVA), intermediate (66.7 cm) (UIVA and CIVA), and near (40 cm) (UNVA and CIVA). Defocus curve was tested monocularly and binocularly. Contrast sensitivity (CS) was measured under photopic and mesopic conditions with and without glare. RESULTS: In IC-8 eyes, the mean ± standard deviation UDVA, UIVA, and UNVA was 0.24 ± 0.18, 0.19 ± 0.18, and 0.14 ± 0.14 logMAR, respectively. Mean CDVA, CIVA, and CNVA in IC-8 eyes was 0.12 ± 0.17, 0.16 ± 0.15, and 0.19 ± 0.13 logMAR, respectively. Binocular mean UDVA, UIVA, and UNVA was 0.07 ± 0.10, 0.07 ± 0.10, and 0.13 ± 0.12 logMAR, respectively. Defocus curve testing yielded a depth of focus of 1.50 D monocularly and 2.00 D binocularly at a 0.2 logMAR threshold. Photopic binocular CS with and without glare improved over monocular CS of IC-8 and fellow eyes under all spatial frequencies. Mesopic binocular CS with and without glare were similar among monocular IC-8 and fellow eyes across spatial frequencies. Most patients reported low levels of visual symptoms. CONCLUSIONS: The IC-8 IOL provides good monocular and binocular visual outcomes for patients with cataract who had aberrated corneas. [J Refract Surg. 2024;40(10):e716-e723.].


Asunto(s)
Sensibilidad de Contraste , Aberración de Frente de Onda Corneal , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Seudofaquia , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Masculino , Femenino , Persona de Mediana Edad , Sensibilidad de Contraste/fisiología , Anciano , Aberración de Frente de Onda Corneal/fisiopatología , Seudofaquia/fisiopatología , Diseño de Prótesis , Refracción Ocular/fisiología , Adulto , Visión Binocular/fisiología
2.
J Refract Surg ; 40(9): e604-e613, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39254241

RESUMEN

PURPOSE: To compare the clinical and aberrometric outcomes obtained with a new diffractive pentafocal intraocular lens (IOL) and a diffractive trifocal IOL. METHODS: Patients bilaterally implanted with the pentafocal Intensity SeeLens IOL (Hanita Lenses) (n = 30) and the trifocal FineVision POD F IOL (PhysIOL) (n = 30) during cataract surgery were studied after 1 month for refraction, visual acuity, defocus curve, contrast sensitivity, Hartmann-Shack aberration, and double-pass aberration. The Quality of Vision (QoV) questionnaire was used to evaluate visual comfort. RESULTS: Distance and near visual acuities were similar with the two IOLs, but distance-corrected intermediate visual acuity was better with the Intensity IOLs (0.03 ± 0.04 vs 0.11 ± 0.04 logMAR in the FineVision eyes, P < .01). The difference between objective and subjective refraction was more myopic for the Intensity IOL (-1.15 vs -0.29 diopters [D]). The defocus curve was flatter with the Intensity IOL. Contrast sensitivity was similar in both IOLs. Hartmann-Shack aberration and double-pass aberration were similar, but the modulation transfer function cut-off value was worse with the Intensity IOL: 11.6 ± 2.7 vs 15.3 ± 4.9 (P < .01). QoV scores were better with the Intensity IOL, in particular for glare, halos, and starburst. CONCLUSIONS: In this comparative series, the pentafocal Intensity IOL provided better intermediate vision and better defocus curve than the FineVision IOL, with comparable distance and near vision. The optical disturbances as reported by the patients were higher with the FineVision IOL. Additional studies will better define the aberration profile obtained with the pentafocal IOL. [J Refract Surg. 2024;40(9):e604-e613.].


Asunto(s)
Sensibilidad de Contraste , Implantación de Lentes Intraoculares , Lentes Intraoculares Multifocales , Facoemulsificación , Diseño de Prótesis , Seudofaquia , Refracción Ocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Sensibilidad de Contraste/fisiología , Femenino , Masculino , Seudofaquia/fisiopatología , Anciano , Persona de Mediana Edad , Encuestas y Cuestionarios , Estudios Prospectivos , Satisfacción del Paciente , Aberrometría , Lentes Intraoculares , Aberración de Frente de Onda Corneal/fisiopatología
3.
J Refract Surg ; 40(9): e645-e653, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39254243

RESUMEN

PURPOSE: To evaluate the intrasession repeatability of wavefront aberrations obtained by a combined adaptive optics visual simulator and Hartman-Shack aberrometer in pseudophakic eyes with and without previous corneal refractive surgery. METHODS: Three consecutive measurements were performed in one eye of each individual. Total ocular aberrations were recorded up to the 5th Zernike order for a 4.5-mm pupil. Repeatability was assessed by calculating the within-subject standard deviation (Sw), the repeatability limit (R), and the intraclass correlation coefficient (ICC). Vector analysis was performed to assess astigmatism variability between scans. RESULTS: The study enrolled 32 normal individuals and 24 individuals with a history of refractive surgery. In normal and eyes that had previous refractive surgery, respectively, the Sw values were 0.155 and 0.176 diopters (D) for sphere and 0.184 and 0.265 D for cylinder. The Sw values for all 3rd order terms ranged from 0.037 to 0.047 µm in normal eyes and 0.044 to 0.063 µm in eyes that had previous refractive surgery. The Sw for primary spherical aberration was 0.020 µm in normal eyes and 0.026 µm in eyes that had previous refractive surgery. ICC values for measurements of astigmatism yielded larger variability (ICC = 0.751 and 0.879). However, both groups demonstrated excellent repeatability (ICC > 0.9) for root mean square higher order aberrations (RMS-HOA) and total RMS values. CONCLUSIONS: In pseudophakic eyes, the adaptive optics Hartmann-Shack device demonstrated acceptable repeatability for measurement of sphere and 3rd and 4th order HOAs with higher variability for astigmatism measurements, especially in eyes with a prior history of corneal refractive surgery. [J Refract Surg. 2024;40(9):e645-e653.].


Asunto(s)
Aberrometría , Aberración de Frente de Onda Corneal , Seudofaquia , Refracción Ocular , Agudeza Visual , Humanos , Seudofaquia/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Reproducibilidad de los Resultados , Femenino , Persona de Mediana Edad , Masculino , Adulto , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Anciano , Topografía de la Córnea , Procedimientos Quirúrgicos Refractivos , Óptica y Fotónica , Estudios Prospectivos , Córnea/fisiopatología
6.
BMC Ophthalmol ; 24(1): 388, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227793

RESUMEN

BACKGROUND: Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. METHODS: This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. RESULTS: Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (ß = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (ß = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (ß = -16.653, P < 0.001). CONCLUSIONS: The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Femenino , Adulto , Masculino , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Láseres de Excímeros/uso terapéutico , Adulto Joven , Estudios de Seguimiento , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Sustancia Propia/cirugía , Cirugía Laser de Córnea/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Córnea/cirugía , Miopía Degenerativa/cirugía , Miopía Degenerativa/fisiopatología , Periodo Posoperatorio
7.
Int Ophthalmol ; 44(1): 331, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39037500

RESUMEN

PURPOSE: To compare the clinical outcomes of myopiacorrected with corneal-wavefront-guided (CWG) laser in situ keratomileusis (LASIK) with AMARIS 1050S (SCHWIND eye-tech-solutions GmbH & Co. KG) and corneal-topography-guided (CTG) LASIK with WaveLight EX500 (Alcon Laboratories, Fort Worth, TX). METHODS: In this prospective, pseudo-randomized expanded cohort study, a total of 266 patients were subjected to binocular LASIK surgery, either with WaveLight EX500 (WaveLight group) or Amaris 1050S (AMARIS group) platforms. Data related to right eyes were selected for analysis. Corneal higher-order aberration (HOA) was selected as the primary endpoint; while visual acuity and refraction were the secondary endpoints. All the endpoints were assessed at 3 months postoperatively. RESULTS: There were 134 eyes in the AMARIS group and 132 eyes in the WaveLight group. After 3 months of postoperative follow-up, spherical and coma aberrations were significantly lower (P < 0.05) in the WaveLight group (spherical aberration: - 0.104 ± 0.199 µm; coma aberration: - 0.117 ± 0.202 µm) in comparison with the AMARIS group (spherical aberrations: 0.254 ± 0.146 µm; coma aberrations: 0.316 ± 0.297 µm). In the AMARIS group, 96.3% of the eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 while in the WaveLight group, 96.2% of the eyes achieved an UDVA of 20/20. Furthermore, the mean postoperative manifest refraction spherical equivalent (MRSE) was - 0.02 ± 0.28 in the AMARIS group and - 0.05 ± 0.21 in the WaveLight group (P = 0.34). CONCLUSIONS: Both WaveLight EX500 and Amaris 1050S LASIK showed excellent refractive and visual outcomes. In addition, the WaveLight group showed minimal spherical and coma aberrations when compared to the AMARIS group.


Asunto(s)
Córnea , Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Femenino , Estudios Prospectivos , Masculino , Adulto , Refracción Ocular/fisiología , Miopía/cirugía , Miopía/fisiopatología , Láseres de Excímeros/uso terapéutico , Córnea/cirugía , Adulto Joven , Resultado del Tratamiento , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/diagnóstico , Estudios de Seguimiento
8.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007813

RESUMEN

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Asunto(s)
Sensibilidad de Contraste , Percepción de Profundidad , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Diseño de Prótesis , Seudofaquia , Agudeza Visual , Humanos , Estudios Retrospectivos , Agudeza Visual/fisiología , Masculino , Femenino , Sensibilidad de Contraste/fisiología , Anciano , Persona de Mediana Edad , Seudofaquia/fisiopatología , Percepción de Profundidad/fisiología , Refracción Ocular/fisiología , Migracion de Implante de Lente Artificial/fisiopatología , Anciano de 80 o más Años , Periodo Posoperatorio , Longitud Axial del Ojo , Aberración de Frente de Onda Corneal/fisiopatología
9.
J Refract Surg ; 40(7): e490-e498, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007811

RESUMEN

PURPOSE: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions). METHODS: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals. RESULTS: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group (P < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group (P < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group (P < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively (P < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all P < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all P < .001). CONCLUSIONS: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. [J Refract Surg. 2024;40(7):e490-e498.].


Asunto(s)
Sustancia Propia , Láseres de Excímeros , Queratectomía Fotorrefractiva , Refracción Ocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Láseres de Excímeros/uso terapéutico , Femenino , Masculino , Queratectomía Fotorrefractiva/métodos , Adulto , Refracción Ocular/fisiología , Adulto Joven , Sustancia Propia/cirugía , Cirugía Laser de Córnea/métodos , Miopía Degenerativa/cirugía , Miopía Degenerativa/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Topografía de la Córnea , Estudios de Seguimiento , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Estudios Retrospectivos
10.
Korean J Ophthalmol ; 38(4): 275-283, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38897594

RESUMEN

PURPOSE: To evaluate the outcomes of wavefront-optimized (WFO) and topography-guided (TG) transepithelial photorefractive keratectomy (transPRK) in the treatment of myopia and myopic astigmatism. METHODS: Patients who underwent transPRK using the WaveLight EX500 excimer laser for the correction of myopia and myopic astigmatism between January 2022 and March 2023 were divided into groups of WFO transPRK (77 eyes of 36 patients) or TG transPRK (63 eyes of 31 patients) in this retrospective, observational cohort study. The preoperative and postoperative 3-month refractive and visual outcomes of the two groups were analyzed. RESULTS: In both groups, the uncorrected distance visual acuity was 0.0 logarithm of the minimum angle of resolution or better in 95% of eyes 3 months postoperatively, and the mean manifest refraction spherical equivalent was within ±1.0 diopter in 90% of eyes. No significant differences were observed between the groups in terms of the uncorrected distance visual acuity or astigmatism. A significant induction of higher order aberrations (HOAs) was observed in both groups. However, the induction of total corneal HOAs (p = 0.014) and spherical aberrations (p < 0.001) was significantly lower in the TG group than that in the WFO group. CONCLUSIONS: WFO and TG transPRK effectively improved the visual and refractive outcomes; however, the induction of total corneal HOAs and spherical aberration was lesser following the TG ablation.


Asunto(s)
Topografía de la Córnea , Láseres de Excímeros , Miopía , Queratectomía Fotorrefractiva , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Queratectomía Fotorrefractiva/métodos , Femenino , Masculino , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Adulto , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Miopía/fisiopatología , Resultado del Tratamiento , Adulto Joven , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Estudios de Seguimiento , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/diagnóstico , Cirugía Asistida por Computador/métodos
11.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848055

RESUMEN

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Asunto(s)
Aberración de Frente de Onda Corneal , Implantación de Lentes Intraoculares , Refracción Ocular , Agudeza Visual , Humanos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Factores de Riesgo , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Lentes Intraoculares Multifocales , Percepción de Profundidad/fisiología , Topografía de la Córnea , Córnea/fisiopatología
12.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848057

RESUMEN

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Asunto(s)
Sensibilidad de Contraste , Aberración de Frente de Onda Corneal , Percepción de Profundidad , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Diseño de Prótesis , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Sensibilidad de Contraste/fisiología , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Aberración de Frente de Onda Corneal/fisiopatología , Percepción de Profundidad/fisiología , Visión Binocular/fisiología , Encuestas y Cuestionarios , Estudios Prospectivos , Satisfacción del Paciente , Anciano de 80 o más Años , Resultado del Tratamiento
13.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848059

RESUMEN

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Asunto(s)
Implantación de Lentes Intraoculares , Miopía Degenerativa , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Masculino , Femenino , Persona de Mediana Edad , Adulto , Estudios de Seguimiento , Miopía Degenerativa/fisiopatología , Miopía Degenerativa/cirugía , Estudios Retrospectivos , Aberración de Frente de Onda Corneal/fisiopatología , Rotación
14.
Sci Rep ; 14(1): 14551, 2024 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914606

RESUMEN

This study compares postoperative visual outcomes and optical aberrations after Small Incision Lenticule Extraction (SMILE) in patients with both small (S-Kappa: Kappa angle < 0.2 mm) and large Kappa (L-Kappa: Kappa angle ≥ 0.2 mm) angles. The evaluated aberrations include total higher-order aberrations (HOAs), horizontal coma (HC), vertical coma (VC), and spherical aberrations (SA), with procedures incorporating intraoperative Kappa angle adjustments. We retrospectively analyzed patient records undergoing SMILE utilizing linear mixed models (LMM). We assessed adjusted mean uncorrected distance visual acuity (UDVA), Strehl ratio (SR), total HOAs, VC, and SA at pupils of 3 mm and 6 mm for both S-Kappa and L-Kappa. The disparities between S-Kappa and L-Kappa were evaluated by LMM's adjusted mean differences. The differences in optical metrics were also assessed in eyes grouped by myopia levels: low, moderate, and high. A sensitivity analysis was conducted on a threshold of Kappa angle at 0.3 mm. Eight-five patients (169 eyes) were analyzed, and no significant pre-operative difference was found in UDVA (p = .222) or spherical equivalent (p = .433). Post-operative differences were found in SR at 3 mm pupil size (-0.06, p = .022), total HOA 3 mm (0.15, p = .022), HC 3 mm (0.04, p = .042), VC 3 mm and 6 mm (-0.08, p = .041; 0.04, p = .041). The stratified analysis for high myopia revealed significant differences in UDVA (-0.04, p = .037), HC 3 mm (0.07, p = .03), VC 6 mm (-0.21, p = .001), and SA 3 mm and 6 mm (0.07, p = .037; -0.09, p = .037). Sensitivity analysis showed no significant difference using a 0.3 mm Kappa threshold. While some optical aberrations exhibited statistical differences between S-Kappa and L-Kappa, their clinical significance is limited. Thus, a large Kappa angle might not substantially influence post-operative optical aberrations when intraoperative Kappa angle adjustments are implemented.


Asunto(s)
Miopía , Agudeza Visual , Humanos , Femenino , Masculino , Adulto , Estudios Retrospectivos , Miopía/cirugía , Adulto Joven , Cirugía Laser de Córnea/métodos , Cirugía Laser de Córnea/efectos adversos , Aberración de Frente de Onda Corneal/fisiopatología , Resultado del Tratamiento , Refracción Ocular
15.
J Cataract Refract Surg ; 50(9): 930-935, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38742939

RESUMEN

PURPOSE: To investigate the impact of corneal higher-order aberrations (HOAs) on predicted corrected distance visual acuity (CDVA) in patients with keratoconus at varying simulated pupil apertures. SETTING: Ophthalmology Clinics, Medical University of South Carolina, Charleston, South Carolina. DESIGN: Retrospective chart review study. METHODS: 56 eyes with keratoconus were examined using Scheimpflug tomography during routine examinations before medical intervention. The severity of keratoconus was graded using the Amsler-Krumeich classification. Zernike analysis was used to obtain corneal aberrations using simulated pupil diameters of 6 mm, 4 mm, and 2 mm. These data were extrapolated to obtain the total root mean square HOAs for a 1.6 mm simulated pupil to evaluate the potential effect of a small aperture intraocular lens (IOL). Correlation analysis was used to study the impact and relative contributions of HOAs on CDVA. Convolution of HOAs from OPD-Scan III provided a clinical method to predict CDVA with different simulated pupil sizes in corneas with irregular astigmatism. RESULTS: There were statistically significant positive correlations between photopic CDVA and the magnitude of total and individual (coma, spherical aberration, and trefoil) HOAs in this cohort of keratoconus participants. A keratoconus case with the small aperture IOL confirms the improvement in vision due to the pinhole effect. CONCLUSIONS: The small aperture IOL is expected to markedly reduce aberrations in patients with keratoconus up to Amsler-Krumeich class 4 severity to levels consistent with the levels seen in healthy patients. Convolution of corneal HOAs with the Early Treatment Diabetic Retinopathy Study chart provides a useful simulation of the impact of pinhole optics in aberrated eyes.


Asunto(s)
Topografía de la Córnea , Aberración de Frente de Onda Corneal , Queratocono , Implantación de Lentes Intraoculares , Lentes Intraoculares , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/diagnóstico , Agudeza Visual/fisiología , Estudios Retrospectivos , Aberración de Frente de Onda Corneal/fisiopatología , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven
16.
J Cataract Refract Surg ; 50(9): 919-925, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758195

RESUMEN

PURPOSE: To evaluate visual outcomes of high hyperopic laser in situ keratomileusis (LASIK), using corneal aspherization to control the induced spherical aberration. SETTING: Fondation Ophtalmologique Adolphe de Rothschild, Paris, France. DESIGN: Prospective interventional case series. METHODS: Prospective interventional study of consecutive high hyperopes (≥+3 diopters [D] of spherical equivalent [SE]) undergoing LASIK with the WaveLight FS200 femtosecond and EX500 excimer laser platform. An aspheric ablation profile (planned change in corneal asphericity ΔQ = +0.2) was delivered using the Custom-Q nomogram on an optical zone of ≥6.5 mm centered near the corneal vertex. Uncorrected corrected distance visual acuity (UDVA) and corrected distance visual acuity, as well as changes in SE, corneal asphericity (ΔQ), and higher-order aberrations, were analyzed preoperatively and on day 1, 1, 3, 6, and 12 months. RESULTS: 117 eyes of 63 patients (mean age of 30.1 ± 5.6 years) were included. Preoperatively and at 12 months postoperatively, the mean SE was 5.1 ± 1.1 D and 0.00 ± 0.7 D, respectively. 88% of eyes achieved 0 logMAR or better UDVA at 12 months. 1 month postoperatively, there was a statistically significant induction of positive spherical aberration decreasing progressively and significantly until the last visit (preop SA4 = 0.09 ± 0.11 µm, day 1 SA4 = 0.30 ± 0.32 µm, 12 months SA4 = 0.08 ± 0.21 µm, P = .056). 2 eyes needed enhancement at 12 months. CONCLUSIONS: LASIK for high levels of hyperopia showed good outcomes mainly due to aspheric-customized ablation profile with a change of ΔQ = +0.2 in corneal asphericity.


Asunto(s)
Topografía de la Córnea , Aberración de Frente de Onda Corneal , Hiperopía , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Agudeza Visual/fisiología , Adulto , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología , Masculino , Femenino , Aberración de Frente de Onda Corneal/fisiopatología , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Enfermedades Hereditarias del Ojo
18.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
19.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741093

RESUMEN

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Aberración de Frente de Onda Corneal , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Miopía/cirugía , Miopía/fisiopatología , Astigmatismo/fisiopatología , Astigmatismo/etiología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Cirugía Laser de Córnea/métodos , Cirugía Laser de Córnea/efectos adversos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Adulto Joven , Refracción Ocular/fisiología , Sustancia Propia/cirugía , Estudios Retrospectivos , Láseres de Excímeros/uso terapéutico , Complicaciones Posoperatorias , Topografía de la Córnea , Adolescente
20.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA