Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.998
Filtrar
Más filtros











Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 24(1): 330, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943106

RESUMEN

BACKGROUND: The purpose of this study was to review echocardiography-based diagnosis of persistent fifth aortic arch (PFAA) in children. METHODS: From January 2015 to December 2022, we retrospectively analyzed the echocardiographic findings and the relevant clinical data during follow-up of patients with PFAA who were treated in the Third Affiliated Hospital of Zhengzhou University. The diagnosis was confirmed by computed tomography angiography or surgery. RESULTS: Seven PFAA cases included two Weinberg type A and five Weinberg type B. The anatomical details of PFAA were assessed using a combination of the long-axis view of the left ventricular outflow tract (from the left high parasternal window) and the long-axis view of the aortic arch (from the suprasternal window). In Weinberg type A, the distal fifth and fourth aortic arches were connected to the descending aorta, which was associated with aortic coarctation. In Weinberg type B, the upper arch of the fourth aorta was interrupted, and only the lower arch of the fifth aorta was connected to the descending aorta. Surgical repair of PFAA was indicated in five patients with blood flow disruption, among which four had good postoperative results and one refused surgery. Two patients with unobstructed PFAA blood flow required follow-up rather than surgery. CONCLUSIONS: It is feasible to diagnose PFAA by echocardiography. Combined application of the high parasternal left ventricular outflow tract view and the suprasternal aortic arch view can improve timely detection of different types of PFAA in children.


Asunto(s)
Aorta Torácica , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/anomalías , Aorta Torácica/cirugía , Estudios Retrospectivos , Masculino , Femenino , Lactante , Preescolar , Aortografía , Niño , China , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Resultado del Tratamiento , Factores de Edad , Reproducibilidad de los Resultados , Ecocardiografía
2.
Methodist Debakey Cardiovasc J ; 20(1): 45-48, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38855041

RESUMEN

Left ventricular assist devices (LVAD) are frequently used in the management of end-stage heart failure, especially given the limited availability of donor hearts. The latest HeartMate 3 LVAD delivers non-physiological continuous flow (CF), although the impact on the aorta is not well established. We highlight a case of aortic aneurysm formation complicated by dissection formation that necessitated high-risk re-operative surgery in a patient post CF-LVAD.


Asunto(s)
Aneurisma de la Aorta , Disección Aórtica , Implantación de Prótesis Vascular , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/fisiopatología , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Masculino , Función Ventricular Izquierda , Reoperación , Persona de Mediana Edad , Aortografía , Angiografía por Tomografía Computarizada , Diseño de Prótesis
4.
BMC Cardiovasc Disord ; 24(1): 281, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38811879

RESUMEN

BACKGROUND: Acute coronary syndrome due to coronary artery embolism in the setting of ascending aortic thrombus is an uncommon condition, even rarer when there is no aortic pathology such as aneurysm, severe atherosclerosis, aortic dissection, or thrombophilia (whether inherited or acquired). CASE PRESENTATION: We report a case of a 58-year-old male presented with acute chest pain, electrocardiogram showing non-ST-elevation acute coronary syndrome. The computed tomography angiography of coronary artery revealed a mural thrombus in the proximal part of ascending aorta, located above the left coronary artery ostium, without any aortic pathologies. With the exception of hypertension and cigarette smoking, no other risk factors were identified in this patient that may increase the risk of thrombosis. Given the life-threatening risk of interventional therapy and surgery, the patient determinedly opted for anticoagulant and dual antiplatelet therapy. Then he experienced the reoccurrence of chest pain after 6-day treatment, progressed to anterior and inferior ST-segment elevation myocardial infarction. Coronary artery embolism originating from the ascending aortic thrombus was suspected. Considering the hemodynamic instability of the patient, the medical treatment was continued and bridged to warfarin and aspirin after discharge. Follow-up computed tomography angiography at 6 months showed no obstruction in coronary artery and complete resolution of the thrombus. No thromboembolic events occurred henceforward. CONCLUSIONS: Acute coronary syndrome could be a manifestation of secondary coronary embolism due to ascending aortic thrombus. Currently, there is no standardized guideline for the treatment of aortic mural thrombus, individualized treatment is recommended. When surgical therapy is not applicable for the patient, anticoagulation and dual antiplatelet treatment are alternative treatments that may successfully lead to the resolution of the aortic thrombus.


Asunto(s)
Síndrome Coronario Agudo , Enfermedades de la Aorta , Recurrencia , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo/etiología , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/diagnóstico por imagen , Resultado del Tratamiento , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/complicaciones , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/tratamiento farmacológico , Anticoagulantes/uso terapéutico , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Inhibidores de Agregación Plaquetaria/uso terapéutico , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/terapia , Infarto del Miocardio sin Elevación del ST/etiología , Aortografía
5.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635286

RESUMEN

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Stents , Femenino , Humanos , Masculino , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Medios de Contraste , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
6.
Vasc Endovascular Surg ; 58(6): 595-601, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38607697

RESUMEN

OBJECTIVE: The objective of this study was to investigate the flow effects in different degrees of thoracic aortic stent graft protrusion extension by creating bird beak effect simulations using accurate 3D geometry and a realistic, nonlinear, elastic biomechanical model using computer-aided software SolidWorks. METHODS: Segmentation in 3D of an aortic arch from a computed tomography (CT) scan of a real-life patient was performed using SolidWorks. A parametric analysis of three models was performed: (A) Aortic arch with no stent, (B) 3 mm bird-beak configuration, and (C) 6.5 mm bird-beak configuration. Flow velocity, pressure, vorticity, wall shear stress (WSS), and time average WSS were assessed. RESULTS: The flow velocity in Model A remained relatively constant and low in the area of the ostium of the brachiocephalic artery and doubled in the left subclavian artery. On the contrary, Models B and C showed a decrease in velocity of 52.3 % in the left subclavian artery. Furthermore, Model B showed a drop in velocity of 82.7% below the bird-beak area, whereas Model C showed a decline of 80.9% in this area. The pressure inside the supra-aortic branches was higher in Model B and C compared with Model A. In Model A, vorticity only appeared at the level of the descending aorta, with low to non-vorticity in the aortic arch. In contrast, Models B and C had an average vorticity of 241.4 Hz within the bird beak area. Regarding WSS, Model A, and Model B shared similar WSS in the peak systolic phase, in the aortic arch, and the bird beak area, whereas Model C had an increased WSS by 5 Pa on average at these zones. CONCLUSION: In the present simulations' lower velocities, higher pressures, vortices, and WSS were observed around the bird beak zone, the aortic arch, and the supra-aortic vessels.


Asunto(s)
Aorta Torácica , Aortografía , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Hemodinámica , Modelos Cardiovasculares , Stents , Estrés Mecánico , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Aorta Torácica/fisiología , Humanos , Velocidad del Flujo Sanguíneo , Procedimientos Endovasculares/instrumentación , Implantación de Prótesis Vascular/instrumentación , Simulación por Computador , Flujo Sanguíneo Regional , Modelación Específica para el Paciente , Diseño de Prótesis , Presión Arterial , Dinámicas no Lineales , Fenómenos Biomecánicos , Interpretación de Imagen Radiográfica Asistida por Computador
7.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577923

RESUMEN

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Asunto(s)
Disección Aórtica , Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis Vascular , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Persona de Mediana Edad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Diseño de Prótesis , Prótesis Vascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía
8.
Vasc Endovascular Surg ; 58(6): 663-668, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38527219

RESUMEN

INTRODUCTION: Patients with complex aortic anatomy require meticulous surgical planning to optimize intraoperative and postoperative outcomes. The GORE Excluder Conformable Abdominal Aortic Aneurysm Endoprosthesis (CEXC Device, WL Gore and Associates, Flagstaff, AZ) allows for endovascular treatment of highly angulated and short proximal neck abdominal aortic aneurysms (AAA). Owing to its recent approval, short-term clinical outcomes of this device remain scarce. REPORT: In this report, we present a case series of 3 patients who underwent endovascular aortic repair using the GORE Excluder Conformable device with highly angulated (>70°) aortic neck anatomy. Endografts were deployed in a radiology suite using standard 2D angiography in conjunction with a CYDAR Medical (Wilmington, Delaware) reconstructed 3D overlay. The patients' ages were 85, 67, and 85 years. The mean abdominal aortic aneurysm diameter in these cases was 6.9 cm. The mean proximal neck length was 2.1 cm, proximal mean neck angulation was 83°. The mean operative time, total fluoroscopy time, and contrast used were 208 minutes, 28.3°minutes, and 94.5 milliliters, respectively. No adjunctive procedures, such as proximal cuff or endo-anchors, were performed at the time of index procedure. DISCUSSION: Type Ia endoleak was observed in 1 patient post-operatively but after treatment with an aortic cuff there was no evidence of enlarging aneurysm sac. The GORE Excluder Conformable Endoprosthesis expands access to endovascular management of AAAs. Our early experience with this device demonstrated excellent patient and clinical outcomes in a highly angulated neck anatomy.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Diseño de Prótesis , Stents , Anciano , Anciano de 80 o más Años , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Factores de Tiempo , Resultado del Tratamiento
9.
Cardiovasc Intervent Radiol ; 47(4): 503-507, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38512351

RESUMEN

PURPOSE: The LIBERTY® Robotic System is a miniature, single-use device designed to facilitate remote-controlled navigation to intravascular targets. We aim to evaluate the robot's performance to manipulate a range of microguidewires and microcatheters during percutaneous endovascular procedures. MATERIALS AND METHODS: Six interventional radiologists performed selective robotic-assisted catheterization of eight pre-determined vascular targets in a pig model. The navigation time from the guiding catheter tip to the target vessel was recorded. Each physician with a clinical experience of 20 years completed a questionnaire to evaluate the ease of use, accuracy, and safety of the robotic operation. RESULTS: Most of the physicians reached the vascular targets in less than one minute. There was no angiographic evidence of vascular injury such as artery laceration or contusion. All physicians reported consensus about the high performance of the robot. CONCLUSION: The miniature disposable robot is effective at reaching a range of vessels in a porcine model. Physicians found the device intuitive and easy to operate remotely.


Asunto(s)
Procedimientos Endovasculares , Procedimientos Quirúrgicos Robotizados , Robótica , Animales , Porcinos , Procedimientos Quirúrgicos Robotizados/métodos , Diseño de Equipo , Aortografía/métodos
10.
Am J Hypertens ; 37(7): 455-464, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38477704

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is associated with accelerated vascular calcification and increased central systolic blood pressure when measured invasively (invCSBP) relative to cuff-based brachial systolic blood pressure (cuffSBP). The contribution of aortic wall calcification to this phenomenon has not been clarified. We, therefore, examined the effects of aortic calcification on cuffSBP and invCSBP in a cohort of patients representing all stages of CKD. METHODS: During elective coronary angiography, invCSBP was measured in the ascending aorta with a fluid-filled catheter with simultaneous recording of cuffSBP using an oscillometric device. Furthermore, participants underwent a non-contrast computed tomography scan of the entire aorta with observer-blinded calcification scoring of the aortic wall ad modum Agatston. RESULTS: We included 168 patients (mean age 67.0 ±â€…10.5, 38 females) of whom 38 had normal kidney function, while 30, 40, 28, and 32 had CKD stages 3a, 3b, 4, and 5, respectively. Agatston scores adjusted for body surface area ranged from 48 to 40,165. We found that invCSBP increased 3.6 (95% confidence interval 1.4-5.7) mm Hg relative to cuffSBP for every 10,000-increment in aortic Agatston score. This association remained significant after adjustment for age, diabetes, antihypertensive treatment, smoking, eGFR, and BP level. No such association was found for diastolic BP. CONCLUSIONS: Patients with advanced aortic calcification have relatively higher invCSBP for the same cuffSBP as compared to patients with less calcification. Advanced aortic calcification in CKD may therefore result in hidden central hypertension despite apparently well-controlled cuffSBP. ClinicalTrials.gov identifier: NCT04114695.


Asunto(s)
Determinación de la Presión Sanguínea , Insuficiencia Renal Crónica , Calcificación Vascular , Humanos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/fisiopatología , Determinación de la Presión Sanguínea/métodos , Enfermedades de la Aorta/fisiopatología , Enfermedades de la Aorta/diagnóstico por imagen , Presión Sanguínea , Angiografía por Tomografía Computarizada , Arteria Braquial/fisiopatología , Arteria Braquial/diagnóstico por imagen , Angiografía Coronaria , Aortografía , Valor Predictivo de las Pruebas
11.
J Vasc Surg ; 80(1): 107-113, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38485071

RESUMEN

OBJECTIVE: Though initially protected from vessel dilation by estrogen, women may experience rapid abdominal aortic aneurysm (AAA) growth post-menopause. The rate of growth has been poorly defined in prior literature. Here, we describe aneurysm growth in a cohort of women found through an AAA screening program. METHODS: Women with AAAs were retrospectively identified. Aortic imaging was reviewed, and measurements of maximum transverse and anterior-posterior diameters were completed. Growth was stratified by the type of aortic pathology (fusiform aneurysm, aortic ectasia, dissection with aneurysmal degeneration, saccular aneurysm) as well as size category (<3 cm, 3.0-3.9 cm, 4.0-4.9 cm, ≥5.0 cm) at diagnosis. RESULTS: A cohort of 488 women was identified; 286 had multiple scans for review. The mean age of the entire cohort was 75 ± 9.9 years. Stratified by type of pathology, the mean age was 76 ± 8.9 years in patients with a fusiform AAA, 74 ± 9.8 years in ectasia, 65 ± 13.7 years in dissection, and 76 ± 5.6 years in saccular aneurysms. The maximum growth was highest in women with fusiform AAAs, followed by dissection, ectasia, and saccular pathology (9.7 mm, 7.0 mm, 3.0 mm, and 2.2 mm, respectively; P < .001). Comparing mean growth by year, the highest mean growth was in fusiform AAAs (3.6 mm vs 1.75 mm in dissection; P < .001). The Shapiro-Wilk test demonstrated that mean growth per year was non-normally distributed with a right skew. Stratified by aortic diameter at the time of diagnosis, mean growth/year increased with increasing size at diagnosis in fusiform AAAs and dissection (0.91 mm for <3 cm, 2.34 mm for 3.0-3.9 cm, 2.49 mm for 4.0-4.9 mm, and 6.16 mm for ≥5.0 cm in patients with fusiform AAAs vs 0.57 mm, 0.94 mm, 1.87 mm, and 2.66 mm, respectively, for patients with dissection). Smoking history was associated with a higher mean growth/year (2.6 mm vs 3.3 mm; P < .001). Conversely, patients with a family history of AAA had a lower mean growth/year (3.2 mm vs 1.5 mm; P < .001). CONCLUSIONS: The rate of aneurysm growth in women varies based on pathology and aneurysm size, and women experience rapid aneurysm growth at sizes greater than 4.5 cm. Current screening guidelines are inadequate, and our results demonstrate that the rate of growth of fusiform aneurysms in women is faster than in men at a smaller size and may warrant more frequent surveillance than current Society for Vascular Surgery recommendations to prevent risk of increased morbidity.


Asunto(s)
Aneurisma de la Aorta Abdominal , Progresión de la Enfermedad , Humanos , Femenino , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/epidemiología , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Factores de Riesgo , Factores de Tiempo , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/patología , Angiografía por Tomografía Computarizada , Aortografía , Factores Sexuales , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/epidemiología , Dilatación Patológica , Posmenopausia
12.
Ann Vasc Surg ; 104: 237-247, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38492732

RESUMEN

BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Hemodinámica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Estrés Mecánico , Humanos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Velocidad del Flujo Sanguíneo , Factores de Tiempo , Aortografía , Flujo Sanguíneo Regional , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Anciano , Masculino , Stents , Hidrodinámica , Reparación Endovascular de Aneurismas
13.
Vasc Endovascular Surg ; 58(6): 655-658, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38491914

RESUMEN

BACKGROUND: Vascular graft infection is a very complex disease. Although complete excision of the infected grafts with extra-anatomic bypass or in situ reconstruction is a general treatment strategy, some concerns including reinfection in the new graft remain. CASE REPORT: An 88 year-old man presented to the hospital with abdominal swelling and bleeding. The patient had undergone revascularization for aorto-iliac occlusive disease twice in the past. The first procedure had been performed 15 years previously, with right ilio-femoral bypass grafting for right iliac artery occlusion and stent implantation for left iliac artery stenosis. The second procedure had been performed 10 years previously, with aorta-to-left femoral and left-to-right femoro-femoral bypass grafting because the terminal aorta, the first ilio-femoral bypass graft, and the stent of the left iliac artery had been occluded. The patient was diagnosed with vascular graft infection, and endovascular therapy was selected as the revascularization method prior to graft excision. It was successfully performed using various devices and techniques, followed by graft excision without critical limb ischemia. CONCLUSION: This case demonstrates that endovascular therapy prior to graft excision can be an alternative revascularization method for vascular graft infection after bypass surgery for aorto-iliac occlusive disease.


Asunto(s)
Enfermedades de la Aorta , Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Prótesis Vascular , Remoción de Dispositivos , Arteria Ilíaca , Infecciones Relacionadas con Prótesis , Humanos , Masculino , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Resultado del Tratamiento , Anciano de 80 o más Años , Arteria Ilíaca/cirugía , Arteria Ilíaca/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Arteriopatías Oclusivas/cirugía , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/etiología , Stents , Reoperación , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Angiografía por Tomografía Computarizada , Aortografía
14.
Vasc Endovascular Surg ; 58(6): 683-684, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38509023
15.
Ann Vasc Surg ; 102: 64-73, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38301848

RESUMEN

BACKGROUND: Local anesthesia (LA) is sparsely used in endovascular aneurysm repair (EVAR) despite short-term benefit, likely secondary to concerns over patient movement preventing accurate endograft deployment. The objective of this study is to examine the association between anesthesia type and endoleak, sac regression, reintervention, and mortality. METHODS: The Vascular Quality Initiative database was queried for all EVAR cases from 2014 to 2022. Patients were included if they underwent percutaneous elective EVAR with anatomical criteria within instructions for use of commercially approved endografts. Multivariable logistic regression with propensity score weighting was used to determine the association between anesthesia type on the risk of any endoleak noted by intraoperative completion angiogram and sac regression. Multivariable survival analysis with propensity score weighting was used to determine the association between anesthesia type and endoleak at 1 year, long-term reintervention, and mortality. RESULTS: Thirteen thousand nine hundred thirty two EVARs met inclusion criteria: 1,075 (8%) LA and 12,857 (92%) general anesthesia (GA). On completion angiogram, LA was associated with fewer rates of any endoleaks overall (16% vs. 24%, P < 0.001). On multivariable analysis with propensity score weighting, LA was associated with similar adjusted odds of any endoleak on intraoperative completion angiogram (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.47-0.68) as well as combined type 1a and type 1b endoleaks (OR 0.72, 95% CI 0.47-1.09). Follow-up computed tomography imaging at 1 year was available for 4,892 patients, 377 (8%) LA and 4,515 (92%) GA. At 1 year, LA was associated with similar rate of freedom from any endoleaks compared to GA (0.66 [95% CI 0.63-0.69] vs. 0.71 [95% CI 0.70-0.72], P = 0.663) and increased rates of sac regression (50% vs. 45%, P = 0.040). On multivariable analysis with propensity score weighting, LA and GA were associated with similar adjusted odds of sac regression (OR 1.22, 95% CI 0.97-1.55). LA and GA had similar rates of endoleak at 1 year (hazard ratio [HR] 0.14, 95% CI 0.63-1.07); however, LA was associated with decreased hazards of combined type 1a and 1b endoleaks at 1 year (HR 0.87, 95% CI 0.80-0.96). LA and GA had similar adjusted long-term reintervention rate (HR 0.77, 95% CI 0.44-1.38) and long-term mortality (HR 1.100, 95% CI 079-1.25). CONCLUSIONS: LA is not associated with increased adjusted rates of any endoleak on completion angiogram or at 1-year follow-up compared to GA. LA is associated with decreased adjusted rates of type 1a and type 1b endoleak at 1 year, but similar rates of sac regression, long-term reintervention, and mortality. Concerns for accurate graft deployment should not preclude use of LA and LA should be increasingly considered when deciding on anesthetic type for standard elective EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Anestesia Local/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Factores de Riesgo , Resultado del Tratamiento , Aortografía/métodos , Estudios Retrospectivos
16.
Ann Vasc Surg ; 102: 9-16, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38301847

RESUMEN

BACKGROUND: Endoleaks are the most common complication after endovascular aneurysm repair (EVAR). Computed tomography angiography (CTA) is presently the golden standard for lifelong surveillance after EVAR. Several studies and meta-analyses have shown contrast-enhanced ultrasound (CEUS) to be a good alternative. The main goal of our study was to further validate the inclusion of CEUS in follow-up examination protocols for the systematic surveillance after EVAR. METHODS: A retrospective analysis of patients who had received CEUS as part of their routine surveillance after EVAR at our center was conducted. Detection rate and classification of endoleak types were compared between available postinterventional CTA/magnetic resonance angiography and follow-up CEUS examinations. Last preinterventional CTAs before EVAR served as baselines with focus on potential cofactors such as age, body mass index, maximum aortic aneurysm diameters, endoleak orientation, and distance-to-surface influencing detection rates and classification. RESULTS: In total, 101 patients were included in the analysis. Forty-four endoleaks (43.5% of cases) were detected by either initial CEUS or CTA, mostly type II (37.6% of the included patients). Initial CEUS showed an endoleak sensitivity of 91.2%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 84.6%. No covariate with an influence on the correct classification could be identified either for CEUS or CT. CONCLUSIONS: CEUS should be considered a valid complementary method to CTA in the lifelong surveillance after EVAR. As type II endoleaks seem to be a common early-term, sometimes spontaneously resolving complication that can potentially be missed by CTA, we suggest combined follow-up protocols including CEUS in the early on postinterventional assessment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Medios de Contraste , Reparación Endovascular de Aneurismas , Endofuga/diagnóstico por imagen , Endofuga/etiología , Estudios de Seguimiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Aortografía/métodos , Estudios Retrospectivos , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Tomografía Computarizada por Rayos X
17.
J Vasc Surg ; 79(6): 1390-1400.e8, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38325564

RESUMEN

OBJECTIVE: This study aims to evaluate a fully automatic deep learning-based method (augmented radiology for vascular aneurysm [ARVA]) for aortic segmentation and simultaneous diameter and volume measurements. METHODS: A clinical validation dataset was constructed from preoperative and postoperative aortic computed tomography angiography (CTA) scans for assessing these functions. The dataset totaled 350 computed tomography angiography scans from 216 patients treated at two different hospitals. ARVA's ability to segment the aorta into seven morphologically based aortic segments and measure maximum outer-to-outer wall transverse diameters and compute volumes for each was compared with the measurements of six experts (ground truth) and thirteen clinicians. RESULTS: Ground truth (experts') measurements of diameters and volumes were manually performed for all aortic segments. The median absolute diameter difference between ground truth and ARVA was 1.6 mm (95% confidence interval [CI], 1.5-1.7; and 1.6 mm [95% CI, 1.6-1.7]) between ground truth and clinicians. ARVA produced measurements within the clinical acceptable range with a proportion of 85.5% (95% CI, 83.5-86.3) compared with the clinicians' 86.0% (95% CI, 83.9-86.0). The median volume similarity error ranged from 0.93 to 0.95 in the main trunk and achieved 0.88 in the iliac arteries. CONCLUSIONS: This study demonstrates the reliability of a fully automated artificial intelligence-driven solution capable of quick aortic segmentation and analysis of both diameter and volume for each segment.


Asunto(s)
Aortografía , Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Humanos , Reproducibilidad de los Resultados , Femenino , Masculino , Anciano , Persona de Mediana Edad , Automatización , Estudios Retrospectivos , Anciano de 80 o más Años , Conjuntos de Datos como Asunto , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía
18.
J Vasc Surg ; 79(6): 1306-1314.e2, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38368998

RESUMEN

OBJECTIVE: Radiation exposure during complex endovascular aortic repair may be associated with tangible adverse effects in patients and operators. This study aimed to identify the steps of highest radiation exposure during fenestrated endovascular aortic repair (FEVAR) and to investigate potential intraoperative factors affecting radiation exposure. METHODS: Prospective data of 31 consecutive patients managed exclusively with four-fenestration endografts between March 1, 2020, and July 1, 2022 were retrospectively analyzed. Leveraging the conformity of the applied technique, every FEVAR operation was considered a combination of six overall stages composed of 28 standardized steps. Intraoperative parameters, including air kerma, dose area product, fluoroscopy time, and number of digital subtraction angiographies (DSAs) and average angulations were collected and analyzed for each step. RESULTS: The mean procedure duration and fluoroscopy time was 140 minutes (standard deviation [SD], 32 minutes), and 40 minutes (SD, 9.1 minutes), respectively. The mean air kerma was 814 mGy (SD, 498 mGy), and the mean dose area product was 66.8 Gy cm2 (SD, 33 Gy cm2). The percentage of air kerma of the entire procedure was distributed throughout the following procedure stages: preparation (13.9%), main body (9.6%), target vessel cannulation (27.8%), stent deployment (29.1%), distal aortoiliac grafting (14.3%), and completion (5.3%). DSAs represented 23.0% of the total air kerma. Target vessel cannulation and stent deployment presented the highest mean lateral angulation (67 and 63 degrees, respectively). Using linear regression, each minute of continuous fluoroscopy added 18.9 mGy of air kerma (95% confidence interval, 17.6-20.2 mGy), and each DSA series added 21.1 mGy of air kerma (95% confidence interval, 17.9-24.3 mGy). Body mass index and lateral angulation were significantly associated with increased air kerma (P < .001). CONCLUSIONS: Cannulation of target vessels and bridging stent deployment are the steps requiring the highest radiation exposure during FEVAR cases. Optimized operator protection during these steps is mandatory.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Dosis de Radiación , Exposición a la Radiación , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Exposición a la Radiación/prevención & control , Exposición a la Radiación/efectos adversos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Factores de Tiempo , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Prótesis Vascular , Anciano de 80 o más Años , Stents , Resultado del Tratamiento , Medición de Riesgo , Tempo Operativo , Aortografía , Persona de Mediana Edad , Angiografía de Substracción Digital , Exposición Profesional/prevención & control , Exposición Profesional/efectos adversos , Fluoroscopía , Reparación Endovascular de Aneurismas
19.
J Vasc Surg ; 79(6): 1315-1325, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38382641

RESUMEN

OBJECTIVE: The aim of this study was to investigate the mid-term results of stented-assisted balloon-induced intimal disruption and relamination (STABILISE) in patients with aortic dissection with the implementation of volumetric analysis. METHODS: This was a single-center retrospective analysis of prospectively collected data. From May 2017 to September 2022, 42 patients underwent STABILISE for acute complicated or subacute high-risk aortic dissection. STABILISE was completed with distal extended endovascular aortic repair in 24 patients. A computed tomography scan was performed at baseline, before hospital discharge, and at 1, 3, and 5 years. Perfused total aortic, true lumen, and false lumen volumes were assessed for thoracic, visceral, and aorto-iliac segment. The ratio between false lumen and total volume was named perfusion dissection index (PDI). Complete remodeling was defined as PDI = 0, and positive remodeling as PDI ≤0.1. RESULTS: Technical success was 97.6%. No 30-day deaths, spinal cord injuries, or retrograde dissections were observed. Mean follow-up was 44 ± 19.4 months. Thoracic diameter was lower at last available computed tomography scan (36.7 vs 33.0 mm; P = .01). Aortic growth >5 mm was observed in 9.5% of the patients. Thoracic and visceral aortic complete remodeling were 92.8% and 83.3%, respectively, with no difference between acute and subacute group. Distal extended endovascular aortic repair significantly increased complete remodeling in the aorto-iliac segment, compared with STABILISE alone (69.6% vs 21.4%; P < .001). Freedom from vascular reinterventions at 3 years was 83.1% (95% confidence interval, 71.5%-96.6%). Total PDI ≤0.1 at first postoperative control was a predictor of vascular reinterventions (P < .0001). CONCLUSIONS: STABILISE is a safe and feasible technique associated with high mid-term rates of complete remodeling in the thoracic and visceral aorta. Volumetric analysis allows the quantification of aortic remodeling and represents a predictor of aortic reinterventions.


Asunto(s)
Disección Aórtica , Stents , Humanos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Masculino , Femenino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Tiempo , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Remodelación Vascular , Angiografía por Tomografía Computarizada , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Reoperación , Aortografía , Factores de Riesgo
20.
Vasc Endovascular Surg ; 58(6): 645-650, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38335135

RESUMEN

OBJECTIVE: Static 3-dimensional (3D) printing became attractive for operative planning in cases that involve difficult anatomy. An interactive (low cost, fast) 3D print allowing deliberate surgical practice can be used to improve interventional simulation and planning. BACKGROUND: Endovascular treatment of complex aortic aneurysms is technically challenging, especially in case of narrow aortic lumen or significant aortic angulation (hostile anatomy). The risk of complications such as graft kinking and target vessel occlusion is difficult to assess based solely on traditional software measuring methods and remain highly dependent on surgeon skills and expertise. METHODS: A patient with juxtarenal AAA with hostile anatomy had a 3-dimensional printed model constructed preoperatively according to computed tomography images. Endovascular graft implantation in the 3D printed aorta with a standard T-Branch Cook (Cook® Medical, Bloomington, IN, USA) was performed preoperatively in the simulation laboratory enabling optimized feasibility, surgical planning and intraoperative decision making. RESULTS: The 3D printed aortic model proved to be radio-opaque and allowed simulation of branched endovascular aortic repair (BREVAR). The assessment of intervention feasibility, as well as optimal branch position and orientation was found to be useful for surgeon confidence and the actual intervention in the patient. There was a remarkable agreement between the 3D printed model and both CT and X-ray angiographic images. Although the technical success was achieved as planned, a previously deployed renal stent caused unexpected difficulty in advancing the renal stent, which was not observed in the 3D model simulation. CONCLUSION: The 3D printed aortic models can be useful for determining feasibility, optimizing planning and intraoperative decision making in hostile anatomy improving the outcome. Despite already offering satisfying accuracy at present, further advancements could enhance the 3D model capability to replicate minor anatomical deformities and variations in tissue density.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Impresión Tridimensional , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Toma de Decisiones Clínicas , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Modelos Cardiovasculares , Modelación Específica para el Paciente , Valor Predictivo de las Pruebas , Diseño de Prótesis , Stents , Cirugía Asistida por Computador , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA