Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.859
Filtrar
Más filtros











Intervalo de año de publicación
1.
PLoS One ; 19(5): e0302972, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38722925

RESUMEN

Electroless nickel plating is a suitable technology for the hydrogen industry because electroless nickel can be mass-produced at a low cost. Investigating in a complex environment where hydrogen permeation and friction/wear work simultaneously is necessary to apply it to hydrogen valves for hydrogen fuel cell vehicles. In this research, the effects of hydrogen permeation on the mechanical characteristics of electroless nickel-plated free-cutting steel (SUM 24L) were investigated. Due to the inherent characteristics of electroless nickel plating, the damage (cracks and delamination of grain) and micro-particles by hydrogen permeation were clearly observed at the grain boundaries and triple junctions. In particular, the cracks grew from grain boundary toward the intergranualr. This is because the grain boundaries and triple junctions are hydrogen permeation pathways and increasing area of the hydrogen partial pressure. As a result, its surface roughness increased by a maximum of two times, and its hardness and adhesion strength decreased by hydrogen permeation. In particular, hydrogen permeation increased the friction coefficient of the electroless nickel-plated layer, and the damage caused by adhesive wear was significantly greater, increasing the wear depth by up to 5.7 times. This is believed to be due to the decreasing in wear resistance of the electroless nickel plating layer damaged by hydrogen permeation. Nevertheless, the Vickers hardness and the friction coefficient of the electroless nickel plating layer were improved by about 3 and 5.6 times, respectively, compared with those of the free-cutting steel. In particular, the electroless nickel-plated specimens with hydrogen embrittlement exhibited significantly better mechanical characteristics and wear resistance than the free-cutting steel.


Asunto(s)
Hidrógeno , Níquel , Acero , Hidrógeno/química , Níquel/química , Acero/química , Suministros de Energía Eléctrica , Propiedades de Superficie , Ensayo de Materiales
2.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38725023

RESUMEN

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Asunto(s)
Espectroscopía Dieléctrica , Ensayo de Materiales , Alambres para Ortodoncia , Saliva Artificial , Acero Inoxidable , Zinc , Corrosión , Acero Inoxidable/química , Zinc/química , Saliva Artificial/química , Aleaciones Dentales/química , Materiales Biocompatibles Revestidos/química , Fluoruros/química , Concentración de Iones de Hidrógeno , Humanos , Propiedades de Superficie , Potenciometría
3.
Braz Oral Res ; 38: e036, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38747823

RESUMEN

This study aimed to evaluate in vitro the effect protocols and anticaries agents containing casein amorphous calcium fluoride phosphopeptide-phosphate (CPP-ACPF, MI Paste Plus), sodium trimetaphosphate (TMP) and fluoride (F), in remineralization of caries lesions. Bovine enamel blocks with initial caries lesions were divided into groups (n = 12): 1) Toothpaste without F-TMP-MI Plus (Placebo); 2) Toothpaste 1100 ppm F (1100F), 3) 1100F + MI Paste Plus (1100F-MI Paste Plus), 4) Toothpaste with 1100F + Neutral gel with 4,500 ppm F + 5%TMP (1100F + Gel TMP) and 5) Toothpaste with 1100F + Neutral gel with 9,000 ppm F (1100F + Gel F). For the 4 and 5 groups the gel was applied only once for 1 minute, initially to the study. For the 3 group, after treatment with 1100F, MI Paste Plus was applied 2x/day for 3 minute. After pH cycling, the percentage of surface hardness recovery (%SHR); integrated loss of subsurface hardness (ΔKHN); profile and depth of the subsuperficial lesion (PLM); concentrations of F, calcium (Ca) and phosphorus (P) in enamel was determined. The data were analyzed by ANOVA (1-criterion) and Student-Newman-Keuls test (p < 0.001). Treatment with 1100F alone led to ~ 28% higher remineralization when compared to treatment with 1100F associated with MI Paste Plus (p < 0.001). The 1100F and 1100F + Gel F groups showed similar values for %SHR (p = 0.150). 1100F + Gel TMP treatment also remineralized the enamel surface by ~ 30% and 20% when compared to the 1100F + Gel F and 1100F groups (p < 0.001). The lower lesion depth (ΔKHN) was observed for the 1100F + Gel TMP group (p < 0.001), where it was 54% and 44% lower in comparison to the 1100F and 1100F + Gel F groups (p < 0.001). Polarized light microscopy photomicrographs showed subsurface lesions in all groups, but these lesions were present to a lower extent in the 1100F + Gel TMP group (p < 0.001). Treatment with 1100F + Gel TMP promoted an increase in the concentration of Ca in the enamel by ~ 57% and ~ 26% when compared to the 1100F and 1100F + MI Paste Plus groups (p < 0.001), respectively. There were no significant differences between the 1100F, 1100F + MI Paste Plus and 1100F + Gel F groups (p > 0.001). Similar values of P in the enamel were observed in the 1100F, 1100F + MI Paste Plus and 1100F + Gel F groups (p > 0.001), except for the 1100F + Gel TMP group, which presented a high concentration (p < 0.001). We conclude that the 1100F+TMP gel treatment/protocol led to a significant increased remineralization when compared to the other treatments/protocols and may be a promising strategy for patients with early caries lesions.


Asunto(s)
Cariostáticos , Caseínas , Esmalte Dental , Fluoruros , Remineralización Dental , Caseínas/farmacología , Caseínas/uso terapéutico , Remineralización Dental/métodos , Bovinos , Animales , Esmalte Dental/efectos de los fármacos , Cariostáticos/farmacología , Fluoruros/farmacología , Factores de Tiempo , Pastas de Dientes/química , Caries Dental/tratamiento farmacológico , Análisis de Varianza , Reproducibilidad de los Resultados , Polifosfatos/farmacología , Polifosfatos/química , Polifosfatos/uso terapéutico , Pruebas de Dureza , Concentración de Iones de Hidrógeno , Propiedades de Superficie/efectos de los fármacos , Ensayo de Materiales , Resultado del Tratamiento , Valores de Referencia , Dureza/efectos de los fármacos , Fosfatos
4.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38766802

RESUMEN

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Asunto(s)
Materiales Biocompatibles Revestidos , Cobalto , Cobre , Células Madre Mesenquimatosas , Propiedades de Superficie , Titanio , Titanio/química , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Células Madre Mesenquimatosas/efectos de los fármacos , Cobre/química , Porosidad , Cobalto/química , Animales , Corrosión , Ensayo de Materiales , Células Cultivadas , Prótesis e Implantes
5.
ACS Appl Bio Mater ; 7(5): 3431-3440, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38697834

RESUMEN

Light-induced release of cisplatin from Pt(IV) prodrugs represents a promising approach for precise control over the antiproliferative activity of Pt-based chemotherapeutic drugs. This method has the potential to overcome crucial drawbacks of conventional cisplatin therapy, such as high general toxicity toward healthy organs and tissues. Herein, we report two Pt(IV) prodrugs with BODIPY-based photoactive ligands Pt-1 and Pt-2, which were designed using carbamate and triazole linkers, respectively. Both prodrugs demonstrated the ability to release cisplatin under blue light irradiation without the requirement of an external reducing agent. Dicarboxylated Pt-2 prodrug turned out to be more stable in the dark and more sensitive to light than its monocarbamate Pt-1 counterpart; these observations were explained using DFT calculations. The investigation of the photoreduction mechanism of Pt-1 and Pt-2 prodrugs using DFT modeling and ΔG0 PET estimation suggests that the photoinduced electron transfer from the singlet excited state of the BODIPY axial ligand to the Pt(IV) center is the key step in the light-induced release of cisplatin from the complexes. Cytotoxicity studies demonstrated that both prodrugs were nontoxic in the dark and toxic to MCF-7 cells under low-dose irradiation with blue light, and the observed effect was solely due to the cisplatin release from the Pt(IV) prodrugs. Our research presents an elegant synthetic approach to light-activated Pt(IV) prodrugs and presents findings that may contribute to the future rational design of photoactivatable Pt(IV) prodrugs.


Asunto(s)
Antineoplásicos , Ensayos de Selección de Medicamentos Antitumorales , Luz , Profármacos , Profármacos/química , Profármacos/farmacología , Profármacos/síntesis química , Humanos , Antineoplásicos/química , Antineoplásicos/farmacología , Antineoplásicos/síntesis química , Estructura Molecular , Ensayo de Materiales , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/síntesis química , Supervivencia Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Cisplatino/farmacología , Cisplatino/química , Tamaño de la Partícula , Compuestos de Boro/química , Compuestos de Boro/farmacología , Compuestos de Boro/síntesis química , Procesos Fotoquímicos , Teoría Funcional de la Densidad
6.
ACS Appl Bio Mater ; 7(5): 3403-3413, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38700026

RESUMEN

The delivery of drugs to the brain in the therapy of diseases of the central nervous system (CNS) remains a continuing challenge because of the lack of delivery systems that can cross the blood-brain barrier (BBB). Therefore, there is a need to develop an innovative delivery method for the treatment of CNS diseases. Thus, we have investigated the interaction of γ-aminobutyric acid (GABA) and S-(-)-γ-amino-α-hydroxybutyric acid (GAHBA) with the GABA receptor by performing a docking study. Both GABA and GAHBA show comparable binding affinities toward the receptor. In this study, we developed surface-modified solid lipid nanoparticles (SLNs) using GAHBA-derived lipids that can cross the BBB. CLB-loaded SLNs were characterized by a number of methods including differential scanning calorimetry, dynamic light scattering, UV-vis spectroscopy, and transmission electron microscopy. The blank and CLB-loaded SLN suspensions were found to exhibit good storage stability. Also, the SLNs showed a higher encapsulation efficiency for CLB drugs. In vitro release kinetics of CLB at physiological temperature was also investigated. The results of the in vitro cell cytotoxicity assay and flow cytometry studies in the human glioma U87MG cell line and human prostate cancer PC3 cell line suggested a higher efficacy of the GAHBA-modified CLB-loaded SLNs in U87MG cells. The transcription level of GABA receptor expression in the target organ and cell line was analyzed by a reverse transcription polymerase chain reaction study. The in vivo biodistribution and brain uptake in C57BL6 mice and SPECT/CT imaging in Wistar rats investigated using 99mTc-labeled SLN and autoradiography suggest that the SLNs have an increasing brain uptake. We have demonstrated the delivery of the anticancer drug chlorambucil (CLB) to glioma.


Asunto(s)
Encéfalo , Clorambucilo , Lípidos , Nanopartículas , Tamaño de la Partícula , Clorambucilo/química , Clorambucilo/farmacología , Clorambucilo/administración & dosificación , Nanopartículas/química , Animales , Encéfalo/metabolismo , Lípidos/química , Humanos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Ensayo de Materiales , Propiedades de Superficie , Ratones , Supervivencia Celular/efectos de los fármacos , Ensayos de Selección de Medicamentos Antitumorales , Sistemas de Liberación de Medicamentos , Ratas , Portadores de Fármacos/química , Línea Celular Tumoral
7.
ACS Appl Bio Mater ; 7(5): 3337-3345, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38700956

RESUMEN

A stimuli-responsive drug delivery nanocarrier with a core-shell structure combining photothermal therapy and chemotherapy for killing cancer cells was constructed in this study. The multifunctional nanocarrier ReS2@mSiO2-RhB entails an ReS2 hierarchical nanosphere coated with a fluorescent mesoporous silica shell. The three-dimensional hierarchical ReS2 nanostructure is capable of effectively absorbing near-infrared (NIR) light and converting it into heat. These ReS2 nanospheres were generated by a hydrothermal synthesis process leading to the self-assembly of few-layered ReS2 nanosheets. The mesoporous silica shell was further coated on the surface of the ReS2 nanospheres through a surfactant-templating sol-gel approach to provide accessible mesopores for drug uploading. A fluorescent dye (Rhodamine B) was covalently attached to silica precursors and incorporated during synthesis in the mesoporous silica walls toward conferring imaging capability to the nanocarrier. Doxorubicin (DOX), a known cancer drug, was used in a proof-of-concept study to assess the material's ability to function as a drug delivery carrier. While the silica pores are not capped, the drug molecule loading and release take advantage of the pH-governed electrostatic interactions between the drug and silica wall. The ReS2@mSiO2-RhB enabled a drug loading content as high as 19.83 mg/g doxorubicin. The ReS2@mSiO2-RhB-DOX nanocarrier's cumulative drug release rate at pH values that simulate physiological conditions showed significant pH responsiveness, reaching 59.8% at pH 6.8 and 98.5% and pH 5.5. The in vitro testing using HeLa cervical cancer cells proved that ReS2@mSiO2-RhB-DOX has a strong cancer eradication ability upon irradiation with an NIR laser owing to the combined drug delivery and photothermal effect. The results highlight the potential of ReS2@mSiO2-RhB nanoparticles for combined cancer therapy in the future.


Asunto(s)
Doxorrubicina , Liberación de Fármacos , Ensayos de Selección de Medicamentos Antitumorales , Ensayo de Materiales , Nanopartículas , Tamaño de la Partícula , Terapia Fototérmica , Renio , Dióxido de Silicio , Dióxido de Silicio/química , Humanos , Doxorrubicina/farmacología , Doxorrubicina/química , Concentración de Iones de Hidrógeno , Nanopartículas/química , Renio/química , Renio/farmacología , Disulfuros/química , Porosidad , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/síntesis química , Supervivencia Celular/efectos de los fármacos , Antineoplásicos/química , Antineoplásicos/farmacología , Portadores de Fármacos/química , Células HeLa
8.
ACS Appl Bio Mater ; 7(5): 3295-3305, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38701399

RESUMEN

Physicochemical properties of nanoparticles, such as particle size, surface charge, and particle shape, have a significant impact on cell activities. However, the effects of surface functionalization of nanoparticles with small chemical groups on stem cell behavior and function remain understudied. Herein, we incorporated different chemical functional groups (amino, DETA, hydroxyl, phosphate, and sulfonate with charges of +9.5, + 21.7, -14.1, -25.6, and -37.7, respectively) to the surface of inorganic silica nanoparticles. To trace their effects on mesenchymal stem cells (MSCs) of rat bone marrow, these functionalized silica nanoparticles were used to encapsulate Rhodamine B fluorophore dye. We found that surface functionalization with positively charged and short-chain chemical groups facilitates cell internalization and retention of nanoparticles in MSCs. The endocytic pathway differed among functionalized nanoparticles when tested with ion-channel inhibitors. Negatively charged nanoparticles mainly use lysosomal exocytosis to exit cells, while positively charged nanoparticles can undergo endosomal escape to avoid scavenging. The cytotoxic profiles of these functionalized silica nanoparticles are still within acceptable limits and tolerable. They exerted subtle effects on the actin cytoskeleton and migration ability. Last, phosphate-functionalized nanoparticles upregulate osteogenesis-related genes and induce osteoblast-like morphology, implying that it can direct MSCs lineage specification for bone tissue engineering. Our study provides insights into the rational design of biomaterials for effective drug delivery and regenerative medicine.


Asunto(s)
Materiales Biocompatibles , Ensayo de Materiales , Células Madre Mesenquimatosas , Nanopartículas , Tamaño de la Partícula , Dióxido de Silicio , Propiedades de Superficie , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/metabolismo , Dióxido de Silicio/química , Dióxido de Silicio/farmacología , Nanopartículas/química , Animales , Ratas , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Osteogénesis/efectos de los fármacos
9.
ACS Appl Bio Mater ; 7(5): 3190-3201, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38709861

RESUMEN

We report an near-infrared (NIR)-trackable and therapeutic liposome with skin tumor specificity. Liposomes with a hydrodynamic diameter of ∼20 nm are tracked under the vein visualization imaging system in the presence of loaded paclitaxel and NIR-active agents. The ability to track liposome nanocarriers is recorded on the tissue-mimicking phantom model and in vivo mouse veins after intravenous administration. The trackable liposome delivery provides in vitro and in vivo photothermal heat (∼40 °C) for NIR-light-triggered area-specific chemotherapeutic release. This approach can be linked with a real-time vein-imaging system to track and apply area-specific local heat, which hitchhikes liposomes from the vein and finally releases them at the tumor site. We conducted studies on mice skin tumors that indicated the disappearance of tumors visibly and histologically (H&E stains). The ability of nanocarriers to monitor after administration is crucial for improving the effectiveness and specificity of cancer therapy, which could be achieved in the trackable delivery system.


Asunto(s)
Rayos Infrarrojos , Liposomas , Paclitaxel , Medicina de Precisión , Neoplasias Cutáneas , Liposomas/química , Animales , Ratones , Neoplasias Cutáneas/patología , Neoplasias Cutáneas/tratamiento farmacológico , Neoplasias Cutáneas/terapia , Paclitaxel/química , Paclitaxel/administración & dosificación , Paclitaxel/farmacología , Ensayo de Materiales , Materiales Biocompatibles/química , Tamaño de la Partícula , Humanos , Sistemas de Liberación de Medicamentos , Ensayos de Selección de Medicamentos Antitumorales
10.
ACS Appl Bio Mater ; 7(5): 2836-2850, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38717017

RESUMEN

High-altitude regions, cold deserts, permafrost regions, and the polar region have some of the severest cold conditions on earth and pose immense perils of cold injuries to exposed individuals. Accidental and unintended exposures to severe cold, either unintentionally or due to occupational risks, can greatly increase the risk of serious conditions including hypothermia, trench foot, and cold injuries like frostbite. Cold-induced vasoconstriction and intracellular/intravascular ice crystal formation lead to hypoxic conditions at the cellular level. The condition is exacerbated in individuals having inadequate and proper covering and layering, particularly when large area of the body are exposed to extremely cold environments. There is a paucity of preventive and therapeutic pharmacological modalities that have been explored for managing and treating cold injuries. Given this, an efficient modality that can potentiate the healing of frostbite was investigated by studying various complex pathophysiological changes that occur during severe cold injuries. In the current research, we report the effectiveness and healing properties of a standardized formulation, i.e., a herbosomal-loaded PEG-poloxamer topical formulation (n-HPTF), on frostbite. The intricate mechanistic pathways modulated by the novel formulation have been elucidated by studying the pathophysiological sequelae that occur following severe cold exposures leading to frostbite. The results indicate that n-HPTF ameliorates the outcome of frostbite, as it activates positive sensory nerves widely distributed in the epidermis transient receptor potential vanilloid 1 (TRPV1), significantly (p < 0.05) upregulates cytokeratin-14, promotes angiogenesis (VEGF-A), prominently represses the expression of thromboxane formation (TXA2), and significantly (p < 0.05) restores levels of enzymatic (glutathione reductase, superoxide dismutase, and catalase) and nonenzymatic antioxidants (glutathione). Additionally, n-HPTF attenuates oxidative stress and the expression of inflammatory proteins PGF-2α, NFκB-p65, TNF-α, IL-6, IL-1ß, malondialdehyde (MDA), advanced oxidative protein products (AOPP), and protein carbonylation (PCO). Masson's Trichrome staining showed that n-HPTF stimulates cellular proliferation, and increases collagen fiber deposition, which significantly (p < 0.05) promotes the healing of frostbitten tissue, as compared to control. We conclude that protection against severe cold injuries by n-HPTF is mediated via modulation of pathways involving TRPV1, VEGF-A, TXA2, redox homeostasis, and inflammatory cascades. The study is likely to have widespread implications for the prophylaxis and management of moderate-to-severe frostbite conditions.


Asunto(s)
Homeostasis , Poloxámero , Polietilenglicoles , Canales Catiónicos TRPV , Factor A de Crecimiento Endotelial Vascular , Factor A de Crecimiento Endotelial Vascular/metabolismo , Canales Catiónicos TRPV/metabolismo , Animales , Poloxámero/química , Poloxámero/farmacología , Polietilenglicoles/química , Polietilenglicoles/farmacología , Homeostasis/efectos de los fármacos , Oxidación-Reducción , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Ratas , Ensayo de Materiales , Lesión por Frío/metabolismo , Lesión por Frío/tratamiento farmacológico , Tamaño de la Partícula , Inflamación/tratamiento farmacológico , Inflamación/metabolismo , Masculino , Liposomas/química , Humanos , Administración Tópica , Congelación de Extremidades/metabolismo , Congelación de Extremidades/tratamiento farmacológico
11.
ACS Appl Bio Mater ; 7(5): 3164-3178, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38722774

RESUMEN

Microbial biofilm accumulation poses a serious threat to the environment, presents significant challenges to different industries, and exhibits a large impact on public health. Since there has not been a conclusive answer found despite various efforts, the potential green and economical methods are being focused on, particularly the innovative approaches that employ biochemical agents. In the present study, we propose a bio-nanotechnological method using magnetic cross-linked polyphenol oxidase aggregates (PPO m-CLEA) for inhibition of microbial biofilm including multidrug resistant bacteria. Free PPO solution showed only 55-60% biofilm inhibition, whereas m-CLEA showed 70-75% inhibition, as confirmed through microscopic techniques. The carbohydrate and protein contents in biofilm extracellular polymeric substances (EPSs) were reduced significantly. The m-CLEA demonstrated reusability up to 5 cycles with consistent efficiency in biofilm inhibition. Computational work was also done where molecular docking of PPO with microbial proteins associated with biofilm formation was conducted, resulting in favorable binding scores and inter-residual interactions. Overall, both in vitro and in silico results suggest that PPO interferes with microbial cell attachment and EPS formation, thereby preventing biofilm colonization.


Asunto(s)
Antibacterianos , Biopelículas , Catecol Oxidasa , Tamaño de la Partícula , Biopelículas/efectos de los fármacos , Catecol Oxidasa/metabolismo , Catecol Oxidasa/química , Catecol Oxidasa/antagonistas & inhibidores , Antibacterianos/farmacología , Antibacterianos/química , Ensayo de Materiales , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Pruebas de Sensibilidad Microbiana , Reactivos de Enlaces Cruzados/química , Reactivos de Enlaces Cruzados/farmacología , Simulación del Acoplamiento Molecular , Escherichia coli/efectos de los fármacos
12.
ACS Appl Bio Mater ; 7(5): 3452-3459, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38723150

RESUMEN

A two-photon nanoparticle probe was designed and developed based on the principle of intermolecular interaction of the aggregation-induced locally excited emission luminescence mechanism. The probe has the advantages of simple synthesis, convenient use, strong atomic economy, good biocompatibility, and photobleaching resistance. It can produce a specific and sensitive response to formaldehyde, help detect FA in normal cells and cancer cells, and is expected to become a specific detection probe for FA in vitro and in vivo.


Asunto(s)
Materiales Biocompatibles , Formaldehído , Ensayo de Materiales , Nanopartículas , Tamaño de la Partícula , Fotones , Formaldehído/química , Formaldehído/análisis , Humanos , Nanopartículas/química , Materiales Biocompatibles/química , Materiales Biocompatibles/síntesis química , Luminiscencia , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Estructura Molecular
13.
ACS Appl Bio Mater ; 7(5): 3283-3294, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38727030

RESUMEN

Medical implants are constantly facing the risk of bacterial infections, especially infections caused by multidrug resistant bacteria. To mitigate this problem, gold nanoparticles with alkyl bromide moieties (Au NPs-Br) on the surfaces were prepared. Xenon light irradiation triggered the plasmon effect of Au NPs-Br to induce free radical graft polymerization of 2-(dimethylamino)ethyl methacrylate (DMAEMA), leading to the formation of poly(DMAEMA) brush-grafted Au NPs (Au NPs-g-PDM). The Au NPs-g-PDM nanocomposites were conjugated with phytic acid (PA) via electrostatic interaction and van der Waals interaction. The as-formed aggregates were deposited on the titanium (Ti) substrates to form the PA/Au NPs-g-PDM (PAP) hybrid coatings through surface adherence of PA and the gravitational effect. Synergistic bactericidal effects of contact-killing caused by the cationic PDM brushes, and local heating generated by the Au NPs under near-infrared irradiation, conferred strong antibacterial effects on the PAP-deposited Ti (Ti-PAP) substrates. The synergistic bactericidal effects reduced the threshold temperature required for the photothermal sterilization, which in turn minimized the secondary damage to the implant site. The Ti-PAP substrates exhibited 97.34% and 99.97% antibacterial and antiadhesive efficacy, respectively, against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli), compared to the control under in vitro antimicrobial assays. Furthermore, the as-constructed Ti-PAP surface exhibited a 99.42% reduction in the inoculated S. aureus under in vivo assays. In addition, the PAP coatings exhibited good biocompatibility in the hemolysis and cytotoxicity assays as well as in the subcutaneous implantation of rats.


Asunto(s)
Antibacterianos , Escherichia coli , Oro , Ensayo de Materiales , Nanopartículas del Metal , Pruebas de Sensibilidad Microbiana , Tamaño de la Partícula , Ácido Fítico , Staphylococcus aureus , Oro/química , Oro/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Antibacterianos/síntesis química , Nanopartículas del Metal/química , Ácido Fítico/química , Ácido Fítico/farmacología , Staphylococcus aureus/efectos de los fármacos , Escherichia coli/efectos de los fármacos , Animales , Propiedades de Superficie , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Cationes/química , Cationes/farmacología , Polímeros/química , Polímeros/farmacología , Titanio/química , Titanio/farmacología
14.
J Cardiothorac Surg ; 19(1): 292, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38760659

RESUMEN

BACKGROUND: Although well-known for their thromboresistance, bileaflet mechanical heart valves (BMHV) require lifelong anti-thrombotic therapy. This must be associated with a certain level of thrombogenicity. Since both thromboresistance and thrombogenicity are explained by the blood-artificial surface or liquid-solid interactions, the aim of the present study was to explore BMHV thromboresistance from new perspectives. The wettability of BMHV pyrolytic carbon (PyC) occluders was investigated in under-liquid conditions. The submerged BMHV wettability clarifies the mechanisms involved in the thromboresistance. METHODS: The PyC occluders of a SJM Regent™ BMHV were previously laser irradiated, to create a surface hierarchical nano-texture, featuring three nano-configurations. Additionally, four PyC occluders of standard BMHV (Carbomedics, SJM Regent™, Bicarbon™, On-X®), were investigated. All occluders were evaluated in under-liquid configuration, with silicon oil used as the working droplet, while water, simulating blood, was used as the surrounding liquid. The under-liquid droplet-substrate wetting interactions were analyzed using contact angle goniometry. RESULTS: All the standard occluders showed very low contact angle, reflecting a pronounced affinity for non-polar molecules. No receding of the contact line could be observed for the untreated occluders. The smallest static contact angle of around 61° could be observed for On-X® valve (the only valve made of full PyC). The laser-treated occluders strongly repelled oil in underwater conditions. A drastic change in their wetting behaviour was observed depending on the surrounding fluid, displaying a hydrophobic behaviour in the presence of air (as the surrounding medium), and showing instead a hydrophilic nature, when surrounded by water. CONCLUSIONS: BMHV "fear" water and blood. The intrinsic affinity of BMHV for nonpolar fluids can be translated into a tendency to repel polar fluids, such as water and blood. The blood-artificial surface interaction in BMHV is minimized. The contact between blood and BMHV surface is drastically reduced by polar-nonpolar Van der Waals forces. The "hydro/bloodphobia" of BMHV is intrinsically related to their chemical composition and their surface energy, thus their material: PyC indeed. Pertaining to thromboresistance, the surface roughness does not play a significant role. Instead, the thromboresistance of BMHV lies in molecular interactions. BMHV wettability can be tuned by altering the surface interface, by means of nanotechnology.


Asunto(s)
Prótesis Valvulares Cardíacas , Trombosis , Humectabilidad , Humanos , Trombosis/prevención & control , Diseño de Prótesis , Ensayo de Materiales
15.
BMC Musculoskelet Disord ; 25(1): 397, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773452

RESUMEN

BACKGROUND: This study aimed to evaluate the biomechanical effects of reinserted or revised subaxial cervical vertebral screws. METHODS: The first part aimed to gauge the maximum insertional torque (MIT) of 30 subaxial cervical vertebrae outfitted with 4.0-mm titanium screws. A reinsertion group was created wherein a screw was wholly removed and replaced along the same trajectory to test its maximum pullout strength (MPOS). A control group was also implemented. The second part involved implanting 4.0-mm titanium screws into 20 subaxial cervical vertebrae, testing them to failure, and then reinserting 4.5-mm revision screws along the same path to determine and compare the MIT and MPOS between the test and revision groups. RESULTS: Part I findings: No significant difference was observed in the initial insertion's maximum insertion torque (MIT) and maximum pull-out strength (MPOS) between the control and reinsertion groups. However, the MIT of the reinsertion group was substantially decreased compared to the first insertion. Moderate to high correlations were observed between the MIT and MPOS in both groups, as well as between the MIT of the first and second screw in the reinsertion group. Part II, the MIT and MPOS of the screw in the test group showed a strong correlation, while a modest correlation was observed for the revision screw used in failed cervical vertebrae screw. Additionally, the MPOS of the screw in the test group was significantly higher than that of the revision screw group. CONCLUSION: This study suggests that reinsertion of subaxial cervical vertebrae screws along the same trajectory is a viable option that does not significantly affect fixation stability. However, the use of 4.5-mm revision screws is inadequate for failed fixation cases with 4.0-mm cervical vertebral screws.


Asunto(s)
Tornillos Óseos , Vértebras Cervicales , Torque , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Humanos , Fenómenos Biomecánicos , Masculino , Femenino , Reoperación , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Persona de Mediana Edad , Adulto , Anciano , Titanio , Ensayo de Materiales
16.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38775601

RESUMEN

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Asunto(s)
Aleaciones Dentales , Implantes Dentales , Resistencia Flexional , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Métodos de Anclaje en Ortodoncia , Acero Inoxidable , Propiedades de Superficie , Titanio , Torque , Titanio/química , Acero Inoxidable/química , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Aleaciones Dentales/química , Técnicas In Vitro , Espectrometría por Rayos X , Análisis del Estrés Dental , Humanos , Estrés Mecánico , Densidad Ósea
17.
BMC Musculoskelet Disord ; 25(1): 408, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783272

RESUMEN

BACKGROUND: Tenodesis of the long head of the biceps tendon is frequently performed in shoulder surgery, and all-suture anchors have become more popular as fixation methods. However, uncertainty still exists regarding the ultimate load to failure of all-suture anchors and the best insertion angle at a cortical humeral insertion point. PURPOSE: The purpose of this study was to compare the biomechanical characteristics of three types of all-suture anchors frequently used for biceps tenodesis. In addition, the influence of two different insertion angles was observed in a porcine humeri model. METHODS: The ultimate load to failure and failure mode of three types of all-suture anchors (1.6 FiberTak®, 1.9 FiberTak®, 2.6 FiberTak®, Arthrex®) applicable for subpectoral biceps tenodesis were evaluated at 90° and 45° insertion angles in 12 fresh-frozen porcine humeri. The anchors were inserted equally alternated in a randomized manner at three different insertion sites along the bicipital groove, and the suture tapes were knotted around a rod for pullout testing. In total, 36 anchors were evaluated in a universal testing machine (Zwick & Roell). RESULTS: The 2.6 FiberTak® shows higher ultimate loads to failure with a 90° insertion angle (944.0 N ± 169.7 N; 537.0 N ± 308.8 N) compared to the 1.9 FiberTak® (677.8 N ± 57.7 N; 426.3 N ± 167.0 N, p-value: 0.0080) and 1.6 FiberTak® (733.0 N ± 67.6 N; 450.0 N ± 155.8 N, p-value: 0.0018). All anchor types show significantly higher ultimate loads to failure and smaller standard deviations at the 90° insertion angle than at the 45° insertion angle. The major failure mode was anchor pullout. Only the 2.6 FiberTak® anchors showed suture breakage as the major failure mode when placed with a 90° insertion angle. CONCLUSIONS: All three all-suture anchors are suitable fixation methods for subpectoral biceps tenodesis. Regarding our data, we recommend 90° as the optimum insertion angle. CLINICAL RELEVANCE: The influence of anchor size and insertion angle of an all-suture anchor should be known by the surgeon for optimizing ultimate loads to failure and for achieving a secure fixation.


Asunto(s)
Anclas para Sutura , Tenodesis , Animales , Tenodesis/métodos , Tenodesis/instrumentación , Porcinos , Fenómenos Biomecánicos , Ensayo de Materiales , Músculo Esquelético/cirugía , Músculo Esquelético/fisiopatología , Tendones/cirugía , Tendones/fisiopatología , Modelos Animales , Soporte de Peso
18.
J Orthop Surg Res ; 19(1): 318, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38807224

RESUMEN

BACKGROUND: Nonfusion technologies, such as motion-preservation devices, have begun a new era of treatment options in spine surgery. Motion-preservation approaches mainly include total disc replacement for anterior cervical discectomy and fusion. However, for multisegment fusion, such as anterior cervical corpectomy and fusion, the options are more limited. Therefore, we designed a novel 3D-printed motion-preservation artificial cervical corpectomy construct (ACCC) for multisegment fusion. The aim of this study was to explore the feasibility of ACCC in a goat model. METHODS: Goats were treated with anterior C3 corpectomy and ACCC implantation and randomly divided into two groups evaluated at 3 or 6 months. Radiography, 3D CT reconstruction and MRI evaluations were performed. Biocompatibility was evaluated using micro-CT and histology. RESULTS: Postoperatively, all goats were in good condition, with free neck movement. Implant positioning was optimal. The relationship between facet joints was stable. The range of motion of the C2-C4 segments during flexion-extension at 3 and 6 months postoperatively was 7.8° and 7.3°, respectively. The implants were wrapped by new bone tissue, which had grown into the porous structure. Cartilage tissue, ossification centres, new blood vessels, and bone mineralization were observed at the porous metal vertebrae-bone interface and in the metal pores. CONCLUSIONS: The ACCC provided stabilization while preserving the motion of the functional spinal unit and promoting bone regeneration and vascularization. In this study, the ACCC was used for anterior cervical corpectomy and fusion (ACCF) in a goat model. We hope that this study will propel further research of motion-preservation devices.


Asunto(s)
Vértebras Cervicales , Cabras , Impresión Tridimensional , Fusión Vertebral , Animales , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Fusión Vertebral/métodos , Rango del Movimiento Articular , Modelos Animales , Materiales Biocompatibles , Ensayo de Materiales/métodos , Factores de Tiempo , Discectomía/métodos
19.
PLoS One ; 19(5): e0299001, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38805439

RESUMEN

Polypropylene fiber was equally mixed into alkali-activated slag fly ash geopolymer in order to ensure the filling effect of mine goaf and improve the stability of cemented gangue paste filling material with ecological matrix. Triaxial compression tests were then conducted under various conditions. The mechanical properties and damage characteristics of composite paste filling materials are studied, and the damage evolution model of paste filling materials under triaxial compression is established, based on the deviatoric stress-strain curve generated by the progressive failure behavior of samples. Internal physical and chemical mechanisms of the evolution of structure and characteristics are elucidated and comprehended via the use of SEM-EDS and XRD micro-techniques. The results show that the fiber can effectively improve the ultimate strength and the corresponding effective stress strength index of the sample within the scope of the experimental study. The best strengthening effect is achieved when the amount of NaOH is 3% of the mass of the solid material, the amount of fiber is 5‰ of the mass of the solid material, and the length of the fiber is about 12 mm. The action mode of the fiber in the sample is mainly divided into single-grip anchoring and three-dimensional mesh traction. As the crack initiates and develops, connection occurs in the matrix, where the fiber has an obvious interference and retardation effect on the crack propagation, thereby transforming the brittle failure into a ductile failure and consequently improving the fracture properties of the ecological cementitious coal gangue matrix. The theoretical damage evolution model of a segmented filling body is constructed by taking the initial compaction stage end point as the critical point, and the curve of the damage evolution model of the specimen under different conditions is obtained. The theoretical model is verified by the results from the triaxial compression test. We concluded that the experimental curve is in good agreement with the theoretical curve. Therefore, the established theoretical model has a certain reference value for the analysis and evaluation of the mechanical properties of paste filling materials. The research results can improve the utilization rate of solid waste resources.


Asunto(s)
Sulfato de Calcio , Fuerza Compresiva , Ensayo de Materiales , Sulfato de Calcio/química , Materiales de Construcción/análisis , Polipropilenos/química , Ceniza del Carbón/química , Estrés Mecánico , Cementación/métodos
20.
Sci Rep ; 14(1): 12278, 2024 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-38806559

RESUMEN

Repair and reconstruction of the myopectineal orifice area using meshes is the mainstay of surgical treatment of inguinal hernias. However, the limitations of existing meshes are becoming increasingly evident in clinical applications; thus, the idea of using three-dimensionally (3D)-printed biological meshes was put forward. According to the current level of the 3D printing technology and the inherent characteristics of biological materials, the direct use of the 3D printing technology for making biological materials into finished products suitable for clinical applications is not yet supported, but synthetic materials can be first printed into 3D form carriers, compounded with biological materials, and finally made into finished products. The purpose of this study was to develop a technical protocol for making 3D-printed biomesh carriers using polyurethane as a raw material. In our study: raw material, polyurethane; weight, 20-30 g/m2; weaving method, hexagonal mesh; elastic tension aspect ratio, 2:1; diameters of pores, 0.1-1 mm; surface area, 8 × 12 cm2; the optimal printing layer height, temperature and velocity were 0.1 mm, 210-220 °C and 60 mm/s. Its clinical significance lies in: (1) applied to preoperative planning and design a detailed surgical plan; (2) applied to special types of surgery including patients in puberty, recurrent and compound inguinal hernias; (3) significantly improve the efficiency of doctor-patient communication; (4) it can shorten the operation and recovery period by about 1/3 and can save about 1/4 of the cost for patients; (5) the learning curve is significantly shortened, which is conducive to the cultivation of reserve talents.


Asunto(s)
Poliuretanos , Impresión Tridimensional , Mallas Quirúrgicas , Poliuretanos/química , Humanos , Hernia Inguinal/cirugía , Materiales Biocompatibles/química , Herniorrafia/métodos , Herniorrafia/instrumentación , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA