1.
J Cardiovasc Electrophysiol ; 35(4): 821-831, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38424678

RESUMEN

INTRODUCTION: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter-defibrillators using a unique setting of different sequential orders of both ATP algorisms. METHODS: Patients with the iATP algorithm were assigned to iATP-first and conventional ATP-first groups sequentially. In the iATP-first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP-first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups. RESULTS: Fifty-eight and 56 patients were enrolled in the iATP-first and conventional ATP-first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). CONCLUSIONS: iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Estimulación Cardíaca Artificial/efectos adversos , Adenosina Trifosfato
2.
Semin Cardiothorac Vasc Anesth ; 28(1): 38-46, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38284295

RESUMEN

Since their initial approval by the Food and Drug Administration in 2016, leadless pacemakers have become increasingly prevalent. This growth has been driven by an improved adverse effect profile when compared to traditional pacemakers, including lower rates of infection, as well as eliminated risk of pocket hematoma and lead complications. More recently, technology enabling leadless synchronized atrioventricular pacing in patients with atrioventricular block has vastly expanded the indications for these devices. Anesthesiologists will increasingly be relied upon to safely care for patients with leadless pacemakers undergoing non-electrophysiology procedures and surgery. This article provides an overview of the technology, evidence base, current indications, and unique perioperative considerations for leadless pacemakers.


Asunto(s)
Marcapaso Artificial , Humanos , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Diseño de Equipo
3.
J Am Heart Assoc ; 13(3): e032760, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38293932

RESUMEN

BACKGROUND: Data regarding permanent pacemaker (PPM) implantation following tricuspid valve surgery (TVS) are limited. We sought to evaluate its incidence, risk factors, and outcomes. METHODS AND RESULTS: Medicare beneficiaries who underwent TVS from 2013 to 2020 were identified. Patients who underwent TVS for endocarditis were excluded. The primary exposure of interest was new PPM after TVS. Outcomes included all-cause mortality and readmission with endocarditis or heart failure on follow-up. Among the 13 294 patients who underwent TVS, 2518 (18.9%) required PPM placement. Risk factors included female sex (relative risk [RR], 1.26 [95% CI, 1.17-1.36], P<0.0001), prior sternotomy (RR, 1.12 [95% CI, 1.02-1.23], P=0.02), preoperative second-degree heart block (RR, 2.20 [95% CI, 1.81-2.69], P<0.0001), right bundle-branch block (RR, 1.21 [95% CI, 1.03-1.41], P=0.019), bifascicular block (RR, 1.43 [95% CI, 1.06-1.93], P=0.02), and prior malignancy (RR, 1.23 [95% CI, 1.01-1.49], P=0.04). Tricuspid valve (TV) replacement was associated with a significantly higher risk of PPM implantation when compared with TV repair (RR, 3.20 [95% CI, 2.16-4.75], P<0.0001). After a median follow-up of 3.1 years, mortality was not different in patients who received PPM compared with patients who did not (hazard ratio [HR], 1.02 [95% CI, 0.93-1.12], P=0.7). PPM placement was not associated with a higher risk of endocarditis but was associated with a higher risk of heart failure readmission (HR, 1.28 [95% CI, 1.14-1.43], P<0.001). CONCLUSIONS: PPM implantation frequently occurs after TVS, notably in female patients and patients undergoing TV replacement. Although mortality is not increased, it is associated with higher rates of heart failure rehospitalization.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Estados Unidos/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Incidencia , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Medicare , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Endocarditis/cirugía , Válvula Aórtica/cirugía , Estudios Retrospectivos
4.
J Interv Card Electrophysiol ; 67(3): 471-477, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37394659

RESUMEN

BACKGROUND: The effect of His bundle pacing (HBP) on the incidence of new-onset atrial fibrillation (AF) after pacemaker implantation (PMI) for atrioventricular conduction disturbance (AVCD) remains unknown. We compared the incidence of new-onset atrial high-rate episode (AHRE) in conventional right ventricular (RV) septum pacing (RVSP) and His bundle pacing (HBP) after PMI for AVCD. METHODS: One hundred and four consecutive patients who underwent dual chamber PMI for AVCD in our hospital were screened. Thirty-five patients with mitral or aortic valve disease, history of open-heart surgery, prior AF, subclinical AF, cumulative ventricular pacing percentage < 90%, and RV lead revision were excluded, and 69 patients were effectively enrolled in this study. The primary endpoint was new-onset AHRE within the follow-up period. New-onset AHRE was defined as an atrial high-rate episode that occurred 3 months after PMI and lasted for > 6 min at an atrial heart rate > 190 bpm. RV leads were placed in the His bundle region and RV septum region in 22 and 47 patients, respectively. The mean follow-up period was 539 ± 218 days. The follow-up period was 2 years after PMI or until the new-onset AHRE occurred. RESULTS: The incidence of new-onset AHRE was lower in the HBP group than in the RVSP group (11% vs. 43%, p = 0.01). Multivariate analysis in the Cox regression hazard model showed that HBP had a significantly lower risk of new-onset AHRE compared with RVSP (HR = 0.21; 95% confidence interval 0.04-0.78, p = 0.02). CONCLUSION: The incidence of new-onset AHRE was significantly less in HBP compared to RVSP during the 2-year follow-up period after pacemaker implantation in AVCD patients with RV pacing dependence.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Tabique Interventricular , Humanos , Fascículo Atrioventricular , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Electrocardiografía , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(12): 2613-2616, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37961021

RESUMEN

INTRODUCTION: Left bundle branch pacing has gained significant momentum in the last few years. The procedure involves deploying the lead deep inside the interventricular septum through left subclavian vein. We aimed at analyzing the feasibility, efficacy and long-term outcome of left bundle branch pacing (LBBP) using lumen-less lead through the right subclavian vein. METHODS: This was a retrospective-institutional, single center observational study done in consecutive patients who underwent LBBP using 3830 selectsecuretm lead. Left subclavian venous access was the primary strategy for lead implantation. Patients requiring right sided approach due to venous obstruction or persistent left superior-vena-cava (PLSVC) for LBBP were included in the study. RESULTS: Right sided approach was successful in 16 out of 19 (84%) attempted patients. C315-His catheter was used in all patients without modifying its curvature. PLSVC (n = 7), left venous obstruction (n = 7), right sided device upgradation (n = 1) and left pocket infection (n = 1) were the reasons for right sided approach. Mean follow-up duration was 17 ± 12 months. LBBP resulted in reduction in QRS duration from 137.3 ± 37.8 ms to 122.3 ± 9.5 ms (p -.13) and increase in LV ejection fraction from 46.2 ± 16.3% to 54.4 ± 11.6% (p -.11). The mean fluoroscopy duration and radiation dose were significantly high in right sided approach (n = 16) as compared to left sided approach (n = 293). In patients requiring cardiac-resynchronization therapy (CRT), right sided LBBP resulted in reduction in QRS duration from 171.8 ± 18.5 to 125.5 ± 11.9 ms (p -.0001) and increase in LVEF from 29.1 ± 3.8 to 45.1 ± 11.9% (p -.005). CONCLUSION: Right sided LBBP is feasible, safe and effective in patients requiring pacing for symptomatic bradyarrhythmia and CRT. Further development in dedicated tools for right-sided approach would help in reducing the fluoroscopy-duration and radiation-dose.


Asunto(s)
Terapia de Resincronización Cardíaca , Vena Cava Superior Izquierda Persistente , Humanos , Bloqueo de Rama , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular , Estudios Retrospectivos , Estudios de Seguimiento , Electrocardiografía/métodos , Terapia de Resincronización Cardíaca/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
6.
BMC Cardiovasc Disord ; 23(1): 575, 2023 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-37990158

RESUMEN

BACKGROUND: This article summarizes the treatment experience for congenital complete atrioventricular block (CCAVB) in newborns and infants, and discusses the necessity and feasibility of treating CCAVB with permanent pacemaker implantation in this population. METHODS: In this study, the clinical data and follow-up results of nine children admitted at our center with CCAVB from January 2005 to March 2023 were retrospectively analyzed. Among them, two children received early implantation of permanent pacemakers (within 1 year of age), two children received non-early implantation (1 year or older), and the remaining five children received no pacemaker implantation. CCAVB diagnosis was confirmed by clinical symptoms and clinical examinations, including electrocardiography and echocardiography before surgery. After surgery, the pacing and sensing functions of the pacemaker were observed using electrocardiography, echocardiography, and pacing threshold monitoring. A comprehensive assessment of the treatment efficacy was conducted, encompassing improvements in clinical symptoms, growth and development, as well as the absence of any additional potential complications. The children who did not receive pacemaker implantation were followed up. RESULTS: Among the four children who successfully received pacemaker implantation, one child who received non-early implantation died. For the remaining three children, the threshold level, amplitude, impedance, and minute ventilation sensor function of the pacemaker were good during the follow-up period, with a heart rate at the pacing rate. The growth and development of the aforementioned patients who received pacemaker implantation demonstrated adherence to the percentile curve, and their motor and cognitive development remained unaffected. However, among the children who did not undergo pacemaker implantation, two experienced death, while three were lost to follow-up, thereby limiting the evaluation of their long-term outcomes. CONCLUSIONS: Early implantation of an epicardial pacemaker at an early stage in newborns and infants diagnosed with CCAVB can significantly improve clinical symptoms without affecting their growth and development. These data are in line with current literature and suggest that early implantation of an epicardial pacemaker in newborns and infants diagnosed with CCAVB but further studies are needed.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Niño , Humanos , Lactante , Recién Nacido , Preescolar , Estudios Retrospectivos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios de Seguimiento
7.
Sci Rep ; 13(1): 16514, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37783787

RESUMEN

Clinical predictors for pacemaker-induced cardiomyopathy (PICM) (e.g., a wide QRS duration and left bundle branch block at baseline) have been reported. However, factors involved in the development of PICM in patients with preserved left ventricular ejection fraction (LVEF) remain unknown. This study aimed to determine the risk factors for PICM in patients with preserved LVEF. The data of 113 patients (average age: 71.3 years; men: 54.9%) who had echocardiography before and after pacemaker implantation (PMI) among 465 patients undergoing dual-chamber PMI were retrospectively analyzed. Thirty-three patients were diagnosed with PICM (18.0/100 person-years; 95% CI 12.8-25.2). A univariate Cox regression analysis showed that an estimated glomerular filtration rate (eGFR) ≤ 30 mL/min/1.73 m2 (HR 3.47; 95% CI 1.48-8.16) and a past medical history of coronary artery disease (CAD) (HR 2.76; 95% CI 1.36-5.60) were significantly associated with the onset of PICM. After adjusting for clinical variables, an eGFR ≤ 30 mL/min/1.73 m2 (HR 2.62; 95% CI 1.09-6.29) and a medical history of CAD (HR 2.32; 95% CI 1.13-4.80) were independent risk factors for developing PICM. A medical history of CAD and low eGFR are independent risk factors for PICM in patients with preserved LVEF at baseline. These results could be helpful in predicting a decreased LVEF by ventricular pacing before PMI. Close follow-up by echocardiography is recommended to avoid a delay in upgrading to physiological pacing, such as cardiac resynchronization therapy or conduction system pacing.


Asunto(s)
Cardiomiopatías , Marcapaso Artificial , Masculino , Humanos , Anciano , Volumen Sistólico , Función Ventricular Izquierda/fisiología , Estudios Retrospectivos , Tasa de Filtración Glomerular , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento
8.
Am J Cardiol ; 209: 76-84, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37865121

RESUMEN

Ablate and pace (A&P) with conduction system pacing (CSP) improves outcomes in patients with symptomatic permanent atrial fibrillation (AF). Data on spontaneous sinus rhythm restoration (SSRR) in this setting are lacking. This study aimed to assess the incidence and the predictors of SSRR in a population of patients with permanent AF who underwent A&P with CSP. Prospective, observational study, enrolling consecutive patients with symptomatic permanent AF (of documented duration >6 months) and uncontrolled, drug-refractory high ventricular rate, who underwent A&P with CSP. The incidence and predictors of SSRR were prospectively assessed. A total of 107 patients (79.0 ± 9.1 years, 33.6% male, 74.8% with New York Heart Association class ≥III, 56.1% with ejection fraction <40%) were enrolled: 40 received His' bundle pacing, 67 left bundle branch area pacing. During a median follow-up of 12 months SSRR was observed in 14 patients (13.1%), occurring a median of 3 months after A&P (interquartile range 1 to 6; range 0 to 17). Multivariable analysis identified a duration of permanent AF <12 months (hazard ratio 7.7, p = 0.040) and a left atrial volume index <49 ml/m2 (hazard ratio 14.8, p = 0.008) as independent predictors of SSRR. In patients with coexistence of both predictors the incidence of SSRR was of 41.4%. In a population of patients with symptomatic, permanent AF, treated with A&P with CSP, SSRR was observed in 13% of patients during follow-up. A duration of permanent AF <12 months and a left atrial volume index <49 ml/m2 were independent predictors of this phenomenon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Femenino , Nodo Atrioventricular/cirugía , Estudios Prospectivos , Estimulación Cardíaca Artificial/efectos adversos , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco/terapia , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
9.
BMJ Case Rep ; 16(10)2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37816572

RESUMEN

The current evidence for vasovagal syncope management is that cardiac pacing is only indicated in a highly select group of patients where symptoms can be linked to bradycardic episodes. High spinal cord injury can lead to autonomic dysfunction and sympathetic nervous system hypoactivity. A high spinal cord injury can theoretically precipitate profound bradycardia leading to haemodynamic instability and syncope. A patient in his 50s with a history of C2 spinal injury was admitted to our tertiary centre for management of what was initially thought to be septic shock causing hypotension and syncope. With evidence to suggest this patient's presentation may be profound reflex syncope in the context of unopposed parasympathetic signalling, consensus was reached to implant a permanent pacemaker. Remarkably, the patient's haemodynamics stabilised and there were no further episodes of syncope.


Asunto(s)
Marcapaso Artificial , Traumatismos de la Médula Espinal , Síncope Vasovagal , Humanos , Bradicardia/etiología , Bradicardia/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Traumatismos de la Médula Espinal/complicaciones , Síncope/terapia , Síncope/complicaciones , Síncope Vasovagal/etiología , Síncope Vasovagal/terapia , Masculino , Persona de Mediana Edad
10.
J Cardiovasc Electrophysiol ; 34(11): 2216-2222, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37727925

RESUMEN

INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Estudios Retrospectivos , Lipopolisacáridos , Resultado del Tratamiento , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos
11.
Indian Heart J ; 75(4): 268-273, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37406856

RESUMEN

OBJECTIVE: Permanent pacemaker implantation (PPI) risk is higher following transcatheter aortic valve implantation (TAVI) than surgical valve replacement. Native aortic leaflets are retained in patients undergoing TAVI, unlike in surgical valve replacement. Whether the retained leaflets influence PPI risk because of their proximity to the conduction system is unknown. The study sought to determine the association between infra-annular extension of native right coronary cusp/noncoronary cusp (RCC/NCC) post balloon-expandable TAVI and PPI risk. METHODS: We performed a retrospective analysis of 190 patients undergoing balloon-expandable TAVI at a single center. Manifestation of infra-annular extension of RCC/NCC was considered to be present when part of leaflet extended below aortic-annular plane on post-implantation aortic-root angiography. RESULTS: Infra-annular extension of RCC/NCC was observed in 33 patients (17.37%). PPI incidence post-TAVI was higher in patients with infra-annular extension of RCC/NCC than in those without (36.36% versus 8.92%, relative-risk: 4.08, p˂0.0001). On logistic-regression analysis, preexisting right bundle-branch block (RBBB) (odds-ratio: 12.73, 95% confidence-interval: 2.16-74.93, p = 0.005), and infra-annular extension of RCC/NCC (odds-ratio: 5.63, 95% confidence-interval: 2.17-14.58, p < 0.0001) were independently associated with PPI risk. Preexisting RBBB (φ = +0.25, p = 0.001) and infra-annular extension of RCC/NCC (φ = +0.30, p < 0.0001) showed a positive-correlation with PPI risk. Infra-annular extension of RCC/NCC was a significant predictor of PPI risk on receiver-operating-characteristic curve analysis (area under-the-curve 0.67; 95% confidence-interval: 0.54-0.79, p = 0.006). CONCLUSION: The retained native aortic leaflets play a significant role in PPI risk following balloon-expandable TAVI. Infra-annular extension of RCC/NCC is a novel predictor, and is associated with a four-fold higher risk of PPI.


Asunto(s)
Estenosis de la Válvula Aórtica , Carcinoma de Células Renales , Prótesis Valvulares Cardíacas , Neoplasias Renales , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Carcinoma de Células Renales/complicaciones , Carcinoma de Células Renales/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Neoplasias Renales/complicaciones , Neoplasias Renales/cirugía , Factores de Riesgo
12.
Heart ; 110(1): 40-48, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37414523

RESUMEN

OBJECTIVE: We sought to investigate prevalence, incidence and prognostic implications of permanent pacemaker (PPM) implantation in patients with cardiac amyloidosis (CA), thereby identifying the predictors of time to PPM implantation. METHODS: Seven hundred eighty-seven patients with CA (602 men, median age 74 years, 571 transthyretin amyloidosis (ATTR), 216 light-chain amyloidosis (AL)) evaluated at two European referral centres were retrospectively included. Clinical, laboratory and instrumental data were analysed. The associations between PPM implantation and mortality, heart failure (HF) or a composite endpoint of mortality, cardiac transplantation and HF were analysed. RESULTS: 81 (10.3%) patients had a PPM before initial evaluation. Over a median follow-up time of 21.7 months (IQR 9.6-45.2), 81 (10.3%) additional patients (18 with AL (22.2%) and 63 with ATTR (77.8%)) underwent PPM implantation with a median time to implantation of 15.6 months (IQR 4.2-40), complete atrioventricular block was the most common indication (49.4%). Independent predictors of PPM implantation were QRS duration (HR 1.03, 95% CI 1.02 to 1.03, p<0.001) and interventricular septum (IVS) thickness (HR 1.1, 95% CI 1.03 to 1.17, p=0.003). The model to estimate the probability of PPM at 12 months and containing both factors showed a C-statistic of 0.71 and a calibration of slope of 0.98. CONCLUSIONS: Conduction system disease requiring PPM is a common complication in CA that affects up to 20.6% of patients. QRS duration and IVS thickness are independently associated with PPM implantation. A PPM implantation at 12 months model was devised and validated to identify patients with CA at higher risk of requiring a PPM and who require closer follow-up.


Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Masculino , Humanos , Anciano , Estudios Retrospectivos , Marcapaso Artificial/efectos adversos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/diagnóstico , Neuropatías Amiloides Familiares/terapia , Pronóstico , Estimulación Cardíaca Artificial/efectos adversos , Factores de Riesgo
13.
Heart Rhythm ; 20(8): 1128-1135, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37271354

RESUMEN

BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing. OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort. METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit. RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%). CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.


Asunto(s)
Marcapaso Artificial , Humanos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/terapia , Resultado del Tratamiento , Estudios Retrospectivos , Lipopolisacáridos , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos
14.
JACC Clin Electrophysiol ; 9(5): 697-700, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37204352

RESUMEN

Intrinsic antitachycardia pacing (iATP) is a novel, automated antitachycardia pacing (ATP) algorithm that provides individualized therapy to terminate ventricular tachycardia (VT). If the first ATP attempt is unsuccessful, the algorithm analyzes the tachycardia cycle length and the postpacing interval and adjusts the subsequent sequence to successfully terminate VT. This algorithm was effective in a single clinical study without a comparator arm. However, iATP failure has not been well-documented in the literature. This publication represents the first case series with episode analysis of iATP failure, including a demonstration of its proarrhythmic effect.


Asunto(s)
Estimulación Cardíaca Artificial , Taquicardia Ventricular , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Taquicardia Ventricular/terapia , Algoritmos , Adenosina Trifosfato
15.
Rev Port Cardiol ; 42(9): 805-809, 2023 09.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37019279

RESUMEN

Glossopharyngeal neuralgia is a rare facial pain syndrome, which in more rare cases can be associated with syncope. We present the outcome of a case report that combines this rare association that received medical therapy with anti-epileptic medication and permanent dual chamber pacemaker implantation. In this case, syncope episodes were associated with both vasodepressor and cardioinhibitory reflex syncope types. The patient found relief from syncope, hypotension, and pain after initiation of anti-epileptic therapy. Although a dual chamber pacemaker was implanted, the pacemaker interrogation revealed no requirement for pacing at one-year follow-up. As far as we know, this is the first case that reports pacemaker interrogation during follow-up and, taking into account the absence of pacemaker activation at one-year follow-up, the device was not needed to prevent bradycardia and syncope episodes. This case report supports the current guidelines for pacing in neurocardiogenic syncope, by demonstrating a lack of requirement for pacing in the event of both cardioinhibitory and vasodepressor responses.


Asunto(s)
Enfermedades del Nervio Glosofaríngeo , Marcapaso Artificial , Síncope Vasovagal , Humanos , Síncope Vasovagal/complicaciones , Síncope Vasovagal/terapia , Estimulación Cardíaca Artificial/efectos adversos , Síncope/etiología , Marcapaso Artificial/efectos adversos , Enfermedades del Nervio Glosofaríngeo/complicaciones , Enfermedades del Nervio Glosofaríngeo/terapia
16.
Adv Clin Exp Med ; 32(6): 707-718, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36881357

RESUMEN

Cardiac pacemaker implantation is an important treatment for symptomatic bradycardia. However, epidemiological data show that the incidence of atrial fibrillation (AF) is significantly higher in patients with implanted pacemakers than in the general population, which may be related to the preoperative presence of multiple risk factors for AF, improvement of diagnostic sensitivity and the pacemaker itself. The pathogenesis of AF after the implantation of pacemaker is related to cardiac electrical remodeling, structural remodeling, inflammation, and autonomic nervous disorder, which are induced by the pacemaker. Moreover, different pacing modes and pacing sites have various effects on the pathogenesis of postoperative AF. Recent studies have reported that reducing the proportion of ventricular pacing, improving the pacing site and setting up special pacing procedures might be highly useful in prevention of AF after pacemaker implantation. This article reviews the epidemiology, pathogenesis, influencing factors, and preventive measures regarding AF after pacemaker surgery.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial/efectos adversos , Bradicardia/complicaciones , Bradicardia/terapia , Ventrículos Cardíacos
17.
Kardiol Pol ; 81(5): 472-481, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36929298

RESUMEN

BACKGROUND: Right ventricular pacing (RVP) can result in pacing-induced cardiomyopathy (PICM). It is unknown whether specific biomarkers reflect differences between His bundle pacing (HBP) and RVP and predict a decrease in left ventricular function during RVP. AIMS: We aimed to compare the effect of HBP and RVP on the left ventricular ejection fraction (LVEF) and to study how they affect serum markers of collagen metabolism. METHODS: Ninety-two high-risk PICM patients were randomized to HBP or RVP groups. Their clinical characteristics, echocardiography, and serum levels of transforming growth factor ß1 (TGF-ß1), matrix metalloproteinase 9 (MMP-9), suppression of tumorigenicity 2 interleukin (ST2-IL), tissue inhibitor of metalloproteinase 1 (TIMP-1), and galectin 3 (Gal-3) were studied before pacemaker implantation and six months later. RESULTS: Fifty-three patients were randomized to the HBP group and 39 patients to the RVP group. HBP failed in 10 patients, who crossed over to the RVP group. Patients with RVP had significantly lower LVEF compared to HBP patients after six months of pacing (-5% and -4% in as-treated and intention-to-treat analysis, respectively). Levels of TGF-ß1 after 6 months were lower in HBP than RVP patients (mean difference -6 ng/ml; P = 0.009) and preimplant Gal-3 and ST2-IL levels were higher in RVP patients, with a decline in LVEF ≥5% compared to those with a decline of <5% (mean difference 3 ng/ml and 8 ng/ml; P = 0.02 for both groups). CONCLUSION: In high-risk PICM patients, HBP was superior to RVP in providing more physiological ventricular function, as reflected by higher LVEF and lower levels of TGF-ß1. In RVP patients, LVEF declined more in those with higher baseline Gal-3 and ST2-IL levels than in those with lower levels.


Asunto(s)
Cardiomiopatías , Función Ventricular Izquierda , Humanos , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Factor de Crecimiento Transformador beta1 , Proteína 1 Similar al Receptor de Interleucina-1 , Inhibidor Tisular de Metaloproteinasa-1 , Estimulación Cardíaca Artificial/efectos adversos , Biomarcadores , Colágeno , Fascículo Atrioventricular , Resultado del Tratamiento , Electrocardiografía
18.
Europace ; 25(3): 1041-1050, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36757859

RESUMEN

AIMS: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. METHODS AND RESULTS: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4-5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48-0.95); diabetes, HR 0.69 (0.53-0.89); TVD, HR 0.60 (0.44-0.82); COPD, HR 0.73 (0.55-0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37-0.89); TVD, HR 0.46 (0.28-0.76); COPD, HR 0.51 (0.29-0.90)) had fewer reinterventions, and in four subgroups (malignancy, HR 0.52 (0.32-0.83); diabetes, HR 0.52 (0.35-0.77); TVD, HR 0.44 (0.28-0.70); COPD, HR 0.55 (0.34-0.89)] had lower rates of the combined outcome. CONCLUSION: In a real-world study, leadless pacemaker patients had lower 2-year complications and reinterventions rates compared with transvenous-VVI pacing in several high-risk subgroups. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT03039712.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Fallo Renal Crónico , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 34(1): 225-228, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36511471

RESUMEN

Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that designs ATP sequences based on the analysis of prior failed ATP. Real-world data on the efficacy and safety of iATP are lacking. Among 124 ventricular tachycardia (VT) episodes in 130 consecutive patients (mean age at implantation: 63.8 ± 14.9 years; sex, 95 male and 35 female) for whom implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator equipped with iATP algorithm was implanted, we investigated the efficacy and safety of iATP for VT refractory to conventional burst pacing. Eight patients had a total of 17 episodes of iATP therapy after failed conventional burst pacing within 11.2 ± 6.6 months of follow-up. Eleven VT episodes (64.7%) in seven patients (87.5%) were successfully terminated by iATP, and only one patient (12.5%) experienced VT acceleration. iATP might be useful for VTs refractory to conventional burst pacing with a low risk of VT acceleration.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Cardioversión Eléctrica/efectos adversos , Adenosina Trifosfato
20.
Braz J Cardiovasc Surg ; 38(2): 278-288, 2023 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-36459472

RESUMEN

Coordinated and harmonic (synchronous) ventricular electrical activation is essential for better left ventricular systolic function. Intraventricular conduction abnormalities, such as left bundle branch block due to artificial cardiac pacing, lead to electromechanical "dyssynchronopathy" with deleterious structural and clinical consequences. The aim of this review was to describe and improve the understanding of all the processes connecting the several mechanisms involved in the development of artificially induced ventricular dyssynchrony by cardiac pacing, most known as pacing-induced cardiomyopathy (PiCM). The chronic effect of abnormal impulse conduction and nonphysiological ectopic activation by artificial cardiac pacing is suspected to affect metabolism and myocardial perfusion, triggering regional differences in the activation/contraction processes that cause electrical and structural remodeling due to damage, inflammation, and fibrosis of the cardiac tissue. The effect of artificial cardiac pacing on ventricular function and structure can be multifactorial, and biological factors underlying PiCM could affect the time and probability of developing the condition. PiCM has not been included in the traditional classification of cardiomyopathies, which can hinder detection. This article reviews the available evidence for pacing-induced cardiovascular disease, the current understanding of its pathophysiology, and reinforces the adverse effects of right ventricular pacing, especially right ventricular pacing burden (commonly measured in percentage) and its repercussion on ventricular contraction (reflected by the impact on left ventricular systolic function). These effects might be the main defining criteria and determining mechanisms of the pathophysiology and the clinical repercussion seen on patients.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Estimulación Cardíaca Artificial/efectos adversos , Función Ventricular Izquierda , Arritmias Cardíacas
SELECCIÓN DE REFERENCIAS