Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Biomed Opt ; 30(Suppl 1): S13703, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39034959

RESUMEN

Significance: Standardization of fluorescence molecular imaging (FMI) is critical for ensuring quality control in guiding surgical procedures. To accurately evaluate system performance, two metrics, the signal-to-noise ratio (SNR) and contrast, are widely employed. However, there is currently no consensus on how these metrics can be computed. Aim: We aim to examine the impact of SNR and contrast definitions on the performance assessment of FMI systems. Approach: We quantified the SNR and contrast of six near-infrared FMI systems by imaging a multi-parametric phantom. Based on approaches commonly used in the literature, we quantified seven SNRs and four contrast values considering different background regions and/or formulas. Then, we calculated benchmarking (BM) scores and respective rank values for each system. Results: We show that the performance assessment of an FMI system changes depending on the background locations and the applied quantification method. For a single system, the different metrics can vary up to ∼ 35 dB (SNR), ∼ 8.65 a . u . (contrast), and ∼ 0.67 a . u . (BM score). Conclusions: The definition of precise guidelines for FMI performance assessment is imperative to ensure successful clinical translation of the technology. Such guidelines can also enable quality control for the already clinically approved indocyanine green-based fluorescence image-guided surgery.


Asunto(s)
Benchmarking , Imagen Molecular , Imagen Óptica , Fantasmas de Imagen , Relación Señal-Ruido , Imagen Molecular/métodos , Imagen Molecular/normas , Imagen Óptica/métodos , Imagen Óptica/normas , Procesamiento de Imagen Asistido por Computador/métodos
2.
Prostate ; 84(8): 717-722, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38450787

RESUMEN

INTRODUCTION: The Society of Nuclear Medicine and Molecular Imaging (SNMMI) provides appropriate use criteria (AUC) for prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) which include guidance on imaging in newly diagnosed prostate cancer and in patients with biochemically recurrent (BCR) disease. This study aims to examine trends in PSMA implementation and the prevalence and outcomes of scans ordered in scenarios deemed rarely appropriate or not meeting SNMMI AUC. METHODS: We retrospectively identified patients who were diagnosed with presumptive National Comprehensive Cancer Network unfavorable intermediate, high, or very high risk prostate cancer, patients who underwent staging for BCR, and all patients staged with PSMA between July 2021 and March 2023. Positivity was validated by adherence to a predetermined reference standard. RESULTS: The frequency of PSMA use increased in initial staging from 24% to 80% and work-up of BCR from 91% to 99% over our study period. In addition, 5% (17/340) of PSMA scans ordered for initial staging did not meet AUC and 3% (15/557) of posttreatment scans were deemed rarely appropriate. Initial staging orders not meeting SNMMI AUC resulted in no positivity (0/17), while rarely appropriate posttreatment scans were falsely positive in 75% (3/4) of cases. Urologists (53%, 17/32) comprised the largest ordering specialty in rarely appropriate use. CONCLUSION: The frequency of PSMA use rose across the study period. A significant minority of patients received PSMA PET/CT in rarely appropriate scenarios yielding no positivity in initial staging and significant false positivity post-therapy. Further education of providers and electronic medical record-based interventions could help limit the rarely appropriate use of PET imaging.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Estadificación de Neoplasias , Medicina Nuclear/métodos , Antígenos de Superficie/análisis , Glutamato Carboxipeptidasa II/metabolismo , Imagen Molecular/métodos , Imagen Molecular/normas
3.
Sci Rep ; 11(1): 22198, 2021 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-34772991

RESUMEN

Magnetic particle imaging (MPI) and fluorine-19 (19F) MRI produce images which allow for quantification of labeled cells. MPI is an emerging instrument for cell tracking, which is expected to have superior sensitivity compared to 19F MRI. Our objective is to assess the cellular sensitivity of MPI and 19F MRI for detection of mesenchymal stem cells (MSC) and breast cancer cells. Cells were labeled with ferucarbotran or perfluoropolyether, for imaging on a preclinical MPI system or 3 Tesla clinical MRI, respectively. Using the same imaging time, as few as 4000 MSC (76 ng iron) and 8000 breast cancer cells (74 ng iron) were reliably detected with MPI, and 256,000 MSC (9.01 × 1016 19F atoms) were detected with 19F MRI, with SNR > 5. MPI has the potential to be more sensitive than 19F MRI for cell tracking. In vivo sensitivity with MPI and 19F MRI was evaluated by imaging MSC that were administered by different routes. In vivo imaging revealed reduced sensitivity compared to ex vivo cell pellets of the same cell number. We attribute reduced MPI and 19F MRI cell detection in vivo to the effect of cell dispersion among other factors, which are described.


Asunto(s)
Rastreo Celular/métodos , Imagen por Resonancia Magnética con Fluor-19/métodos , Animales , Línea Celular , Rastreo Celular/normas , Imagen por Resonancia Magnética con Fluor-19/normas , Procesamiento de Imagen Asistido por Computador , Ratones , Ratones Noqueados , Imagen Molecular/métodos , Imagen Molecular/normas , Sensibilidad y Especificidad
4.
Commun Biol ; 3(1): 458, 2020 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-32820217

RESUMEN

We present LIVE-PAINT, a new approach to super-resolution fluorescent imaging inside live cells. In LIVE-PAINT only a short peptide sequence is fused to the protein being studied, unlike conventional super-resolution methods, which rely on directly fusing the biomolecule of interest to a large fluorescent protein, organic fluorophore, or oligonucleotide. LIVE-PAINT works by observing the blinking of localized fluorescence as this peptide is reversibly bound by a protein that is fused to a fluorescent protein. We have demonstrated the effectiveness of LIVE-PAINT by imaging a number of different proteins inside live S. cerevisiae. Not only is LIVE-PAINT widely applicable, easily implemented, and the modifications minimally perturbing, but we also anticipate it will extend data acquisition times compared to those previously possible with methods that involve direct fusion to a fluorescent protein.


Asunto(s)
Microscopía Fluorescente/métodos , Imagen Molecular/métodos , Péptidos/metabolismo , Proteínas/metabolismo , Proteínas de Escherichia coli/metabolismo , Proteínas Fúngicas/metabolismo , Microscopía Fluorescente/normas , Imagen Molecular/normas , Unión Proteica , Relación Señal-Ruido
5.
Anticancer Res ; 40(6): 3571-3577, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32487660

RESUMEN

BACKGROUND/AIM: We evaluated urinary levels of porphyrin metabolites, such as uroporphyrin (UP) and coproporphyrin (CP), after 5-Aminolevulinic acid (ALA) administration in patients with or without pancreatic cancer (PaC). PATIENTS AND METHODS: Sixty-seven subjects with PaC, 11 with pancreatitis, and 9 with normal pancreas (NP) were enrolled. Urine samples from all subjects were collected prior to ALA administration and at more than 4 hours after ALA administration. We measured the urinary levels of UP and CP by high-performance liquid chromatography analysis. RESULTS: The PaC group showed significantly higher UP levels compared to NP groups (104.9 nmol/g Cre vs. 53.4 nmol/g Cre, p=0.014). Moreover, PaC patients with long-term survival had significantly lower urinary levels of UP at diagnosis (98.8 nmol/gCre) than the short-term survival group (125.2 nmol/gCre) (p=0.042). CONCLUSION: The urinary levels of UP after ALA administration might serve as a promising biomarker for diagnosis and prognosis prediction of PaC.


Asunto(s)
Ácidos Levulínicos , Luz , Imagen Molecular , Neoplasias Pancreáticas/diagnóstico , Fármacos Fotosensibilizantes , Anciano , Biomarcadores , Biomarcadores de Tumor , Detección Precoz del Cáncer , Femenino , Humanos , Ácidos Levulínicos/metabolismo , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Imagen Molecular/métodos , Imagen Molecular/normas , Neoplasias Pancreáticas/metabolismo , Fármacos Fotosensibilizantes/metabolismo , Porfirinas , Sensibilidad y Especificidad , Ácido Aminolevulínico
6.
Expert Rev Mol Diagn ; 20(10): 1027-1037, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32510287

RESUMEN

INTRODUCTION: Tissue-based imaging has emerged as a critical tool in translational cancer research and is rapidly gaining traction within a clinical context. Significant progress has been made in the digital pathology arena, particularly in respect of brightfield and fluorescent imaging. Critically, the cellular context of molecular alterations occurring at DNA, RNA, or protein level within tumor tissue is now being more fully appreciated. Moreover, the emergence of novel multi-marker imaging approaches can now provide unprecedented insights into the tumor microenvironment, including the potential interplay between various cell types. AREAS COVERED: This review summarizes the recent developments within the field of tissue-based imaging, centering on the application of these approaches in oncology research and clinical practice. EXPERT OPINION: Significant advances have been made in digital pathology during the last 10 years. These include the use of quantitative image analysis algorithms, predictive artificial intelligence (AI) on large datasets of H&E images, and quantification of fluorescence multiplexed tissue imaging data. We believe that new methodologies that can integrate AI-derived histologic data with omic data, together with other forms of imaging data (such as radiologic image data), will enhance our ability to deliver better diagnostics and treatment decisions to the cancer patient.


Asunto(s)
Biomarcadores de Tumor , Imagen Molecular/métodos , Neoplasias/patología , Inteligencia Artificial , Manejo de la Enfermedad , Técnica del Anticuerpo Fluorescente/métodos , Técnica del Anticuerpo Fluorescente/normas , Procesamiento de Imagen Asistido por Computador , Inmunohistoquímica/métodos , Inmunohistoquímica/normas , Oncología Médica/métodos , Oncología Médica/normas , Imagen Molecular/normas , Neoplasias/diagnóstico por imagen , Neoplasias/etiología , Pautas de la Práctica en Medicina , Investigación Biomédica Traslacional , Microambiente Tumoral
7.
Int J Mol Sci ; 21(9)2020 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-32349205

RESUMEN

The use of fluorescent imaging probes that monitor the activity of proteases that experience an increase in expression and activity in tumors is well established. These probes can be conjugated to nanoparticles of iron oxide, creating a multimodal probe serving as both a magnetic resonance imaging (MRI) agent and an indicator of local protease activity. Previous works describe probes for cathepsin D (CatD) and metalloproteinase-2 (MMP2) protease activity grafted to cross-linked iron oxide nanoparticles (CLIO). Herein, we have synthesized a triply labeled fluorescent iron oxide nanoparticle molecular imaging (MI) probe, including an AF750 substrate concentration reporter along with probes for cathepsin B (CatB) sand MMP2 protease activity. The reporter provides a baseline signal from which to compare the activity of the two proteases. The activity of the MI probe was verified through incubation with the proteases and tested in vitro using the human HT29 tumor cell line and in vivo using female nude mice injected with HT29 cells. We found the MI probe had the appropriate specificity to the activity of their respective proteases, and the reporter dye did not activate when incubated in the presence of only MMP2 and CatB. Probe fluorescent activity was confirmed in vitro, and reporter signal activation was also noted. The fluorescent activity was also visible in vivo, with injected HT29 cells exhibiting fluorescence, distinguishing them from the rest of the animal. The reporter signal was also observable in vivo, which allowed the signal intensities of the protease probes to be corrected; this is a unique feature of this MI probe design.


Asunto(s)
Colorantes Fluorescentes , Imagen Molecular/métodos , Neoplasias/sangre , Neoplasias/enzimología , Animales , Biomarcadores , Catepsina B , Línea Celular Tumoral , Modelos Animales de Enfermedad , Citometría de Flujo , Humanos , Metaloproteinasa 2 de la Matriz/metabolismo , Ratones , Imagen Molecular/normas , Sensibilidad y Especificidad , Análisis Espectral , Coloración y Etiquetado/métodos
8.
IEEE Trans Biomed Eng ; 67(1): 185-192, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30990172

RESUMEN

OBJECTIVE: Fluorescence molecular imaging (FMI) has emerged as a promising tool for surgical guidance in oncology, with one of the few remaining challenges being the ability to offer quality control and data referencing. This paper investigates the use of a novel composite phantom to correct and benchmark FMI systems. METHODS: This paper extends on previous work by describing a phantom design that can provide a more complete assessment of FMI systems through quantification of dynamic range and determination of spatial illumination patterns for both reflectance and fluorescence imaging. Various performance metrics are combined into a robust and descriptive "system benchmarking score," enabling not only the comprehensive comparison of different systems, but also for the first time, correction of the acquired data. RESULTS: We show that systems developed for targeted fluorescence imaging can achieve benchmarking scores of up to 70%, while clinically available systems optimized for indocyanine green are limited to 50%, mostly due to greater leakage of ambient and excitation illumination and lower resolution. The image uniformity can also be approximated and employed for image flat-fielding, an important milestone toward data referencing. In addition, we demonstrate composite phantom use in assessing the performance of a surgical microscope and of a raster-scan imaging system. CONCLUSION: Our results suggest that the new phantom has the potential to support high-fidelity FMI through benchmarking and image correction. SIGNIFICANCE: Standardization of the FMI is a necessary process for establishing good imaging practices in clinical environments and for enabling high-fidelity imaging across patients and multi-center imaging studies.


Asunto(s)
Imagen Óptica , Fantasmas de Imagen/normas , Imagen Molecular/instrumentación , Imagen Molecular/normas , Imagen Óptica/instrumentación , Imagen Óptica/normas , Estándares de Referencia
9.
J Card Fail ; 25(11): 854-865, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31473267

RESUMEN

Cardiac amyloidosis is emerging as an underdiagnosed cause of heart failure and mortality. Growing literature suggests that a noninvasive diagnosis of cardiac amyloidosis is now feasible. However, the diagnostic criteria and utilization of imaging in cardiac amyloidosis are not standardized. In this paper, Part 2 of a series, a panel of international experts from multiple societies define the diagnostic criteria for cardiac amyloidosis and appropriate utilization of echocardiography, cardiovascular magnetic resonance imaging, and radionuclide imaging in the evaluation of patients with known or suspected cardiac amyloidosis.


Asunto(s)
American Heart Association , Amiloidosis/diagnóstico por imagen , Cardiología/normas , Cardiomiopatías/diagnóstico por imagen , Imagen Multimodal/normas , Sociedades Médicas/normas , Amiloidosis/epidemiología , Amiloidosis/terapia , Cardiología/métodos , Cardiomiopatías/epidemiología , Cardiomiopatías/terapia , Consenso , Ecocardiografía/métodos , Ecocardiografía/normas , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/normas , Imagen Molecular/métodos , Imagen Molecular/normas , Imagen Multimodal/métodos , Medicina Nuclear/métodos , Medicina Nuclear/normas , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Estados Unidos/epidemiología
10.
J Card Fail ; 25(11): e1-e39, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31473268
12.
J Appl Clin Med Phys ; 20(6): 120-124, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31116478

RESUMEN

PURPOSE: To develop an Eclipse plug-in (MLC_MODIFIER) that automatically modifies control points to expose fiducials obscured by MLC during VMAT, thereby facilitating tracking using periodic MV/kV imaging. METHOD: Three-dimensional fiducial tracking was performed during VMAT by pairing short-arc (3°) MV digital tomosynthesis (DTS) images to triggered kV images. To evaluate MLC_MODIFIER efficacy, two cohorts of patients were considered. For first 12 patients, plans were manually edited to expose one fiducial marker. Next for 15 patients, plans were modified using MLC_MODIFIER script. MLC_MODIFIER evaluated MLC apertures at appropriate angles for marker visibility. Angles subtended by control points were compressed and low-dose "imaging" control points were inserted and exposed one marker with 1 cm margin. Patient's images were retrospectively reviewed to determine rate of MV registration failures. Failure categories were poor DTS image quality, MLC blockage of fiducials, or unknown reasons. Dosimetric differences in rectum, bladder, and urethra D1 cc, PTV maximum dose, and PTV dose homogeneity (PTV HI) were evaluated. Statistical significance was evaluated using Fisher's exact and Student's t test. RESULT: Overall MV registration failures, failures due to poor image quality, MLC blockage, and unknown reasons were 33% versus 8.9% (P < 0.0001), 8% versus 6.4% (P < 0.05), 13.6% versus 0.1% (P < 0.0001), and 7.6% versus 2.4% (P < 0.0001) for manually edited and MLC_MODIFIER plans, respectively. PTV maximum and HI increased on average from unmodified plans by 2.1% and 0.3% (P < 0.004) and 22.0% and 3.3% (P < 0.004) for manually edited and MLC_MODIFIED plans, respectively. Changes in bladder, rectum, and urethra D1CC were similar for each method and less than 0.7%. CONCLUSION: Increasing fiducial visibility via an automated process comprised of angular compression of control points and insertion of additional "imaging" control points is feasible. Degradation of plan quality is minimal. Fiducial detection and registration success rates are significantly improved compared to manually edited apertures.


Asunto(s)
Marcadores Fiduciales , Imagen Molecular/normas , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/instrumentación , Radioterapia de Intensidad Modulada/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Masculino , Movimiento , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Estudios Retrospectivos
13.
J Cell Biol ; 218(1): 350-379, 2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30523041

RESUMEN

Growth cones are complex, motile structures at the tip of an outgrowing neurite. They often exhibit a high density of filopodia (thin actin bundles), which complicates the unbiased quantification of their morphologies by software. Contemporary image processing methods require extensive tuning of segmentation parameters, require significant manual curation, and are often not sufficiently adaptable to capture morphology changes associated with switches in regulatory signals. To overcome these limitations, we developed Growth Cone Analyzer (GCA). GCA is designed to quantify growth cone morphodynamics from time-lapse sequences imaged both in vitro and in vivo, but is sufficiently generic that it may be applied to nonneuronal cellular structures. We demonstrate the adaptability of GCA through the analysis of growth cone morphological variation and its relation to motility in both an unperturbed system and in the context of modified Rho GTPase signaling. We find that perturbations inducing similar changes in neurite length exhibit underappreciated phenotypic nuance at the scale of the growth cone.


Asunto(s)
Conos de Crecimiento/ultraestructura , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Imagen Molecular/normas , Neuronas/ultraestructura , Programas Informáticos , Imagen de Lapso de Tiempo/normas , Proteínas de Unión al GTP rho/genética , Animales , Línea Celular Tumoral , Movimiento Celular , Forma de la Célula/genética , Regulación de la Expresión Génica , Heterogeneidad Genética , Conos de Crecimiento/metabolismo , Factores de Intercambio de Guanina Nucleótido/deficiencia , Factores de Intercambio de Guanina Nucleótido/genética , Ratones , Imagen Molecular/métodos , Neuronas/metabolismo , Neuropéptidos/deficiencia , Neuropéptidos/genética , Fosfoproteínas/deficiencia , Fosfoproteínas/genética , Proteínas Serina-Treonina Quinasas/deficiencia , Proteínas Serina-Treonina Quinasas/genética , Seudópodos/metabolismo , Seudópodos/ultraestructura , Factores de Intercambio de Guanina Nucleótido Rho/deficiencia , Factores de Intercambio de Guanina Nucleótido Rho/genética , Transducción de Señal , Imagen de Lapso de Tiempo/métodos , Proteína de Unión al GTP cdc42/deficiencia , Proteína de Unión al GTP cdc42/genética , Proteína de Unión al GTP rac1/deficiencia , Proteína de Unión al GTP rac1/genética , Proteínas de Unión al GTP rho/deficiencia , Proteína de Unión al GTP rhoA
14.
Lancet Oncol ; 19(12): e696-e708, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30507436

RESUMEN

Rapid developments in imaging and treatment with radiopharmaceuticals targeting prostate cancer pose issues for the development of guidelines for their appropriate use. To tackle this problem, international experts representing medical oncologists, urologists, radiation oncologists, radiologists, and nuclear medicine specialists convened at the European Association of Nuclear Medicine Focus 1 meeting to deliver a balanced perspective on available data and clinical experience of imaging in prostate cancer, which had been supported by a systematic review of the literature and a modified Delphi process. Relevant conclusions included the following: diphosphonate bone scanning and contrast-enhanced CT are mentioned but rarely recommended for most patients in clinical guidelines; MRI (whole-body or multiparametric) and prostate cancer-targeted PET are frequently suggested, but the specific contexts in which these methods affect practice are not established; sodium fluoride-18 for PET-CT bone scanning is not widely advocated, whereas gallium-68 or fluorine-18 prostate-specific membrane antigen gain acceptance; and, palliative treatment with bone targeting radiopharmaceuticals (rhenium-186, samarium-153, or strontium-89) have largely been replaced by radium-223 on the basis of the survival benefit that was reported in prospective trials, and by other systemic therapies with proven survival benefits. Although the advances in MRI and PET-CT have improved the accuracy of imaging, the effects of these new methods on clinical outcomes remains to be established. Improved communication between imagers and clinicians and more multidisciplinary input in clinical trial design are essential to encourage imaging insights into clinical decision making.


Asunto(s)
Biomarcadores de Tumor/genética , Imagen Molecular/normas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Nanomedicina Teranóstica/normas , Consenso , Técnica Delphi , Humanos , Masculino , Valor Predictivo de las Pruebas , Neoplasias de la Próstata/genética , Resultado del Tratamiento
15.
Theranostics ; 8(19): 5336-5347, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30555550

RESUMEN

Intraoperative fluorescence imaging is particularly well-suited for surgical applications due to its inherently high sensitivity, resolution, and ability to provide images in real-time. To date, the intraoperative observation of fluorescence has largely been subjective. With the need to show objective evidence in order to demonstrate the benefit of this technique, quantitative data needs to be provided to overseeing regulatory bodies. Standardization of fluorescence imaging protocols would improve reproducibility and minimize inter- and intra-institution variance. This would allow studies to be conducted using the same injection techniques, imaging times, reconstruction methods, and analyses. Here, we provide recommendations for standardized methodologies with the goal of setting a minimum requirement for reporting fluorescence-guided surgery results based on both qualitative and (semi-) quantitative data collection. Clinical trials using fluorescence-guided surgery should present results of three critical elements; 1) intra-operative imaging, 2) specimen mapping and pathology correlation, and 3) target validation. Qualitative analyses should consist of a bright field image, black-and-white fluorescence image, pseudo-colored fluorescence overlay image, and/or heat-map whereby fluorescence signal intensity differences are displayed on a color spectrum. Quantitative analyses should include 1) intraoperative data (consisting of images or video, raw numeric values and ratios); 2) specimen mapping, for correlation of fluorescence with the presence of disease (performed using fresh tissue); and 3) target validation (designed to determine fluorescence intensity relative to receptor density of a specific area). Including the aforementioned methods of both qualitative and quantitative analyses will ensure that trial results are comparable and could be collated in future studies to expedite FDA approval.


Asunto(s)
Aprobación de Drogas/métodos , Imagen Molecular/métodos , Imagen Molecular/normas , Imagen Óptica/métodos , Imagen Óptica/normas , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/normas , Ensayos Clínicos como Asunto , Humanos
16.
Contrast Media Mol Imaging ; 2018: 6930425, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29977173

RESUMEN

High expression of human epidermal growth factor receptor 2 (HER2) in breast and gastroesophageal carcinomas is a predictive biomarker for treatment using HER2-targeted therapeutics (antibodies trastuzumab and pertuzumab, antibody-drug conjugate trastuzumab DM1, and tyrosine kinase inhibitor lapatinib). Radionuclide molecular imaging of HER2 expression might permit stratification of patients for HER2-targeting therapies. In this study, we evaluated a new HER2-imaging probe based on the designed ankyrin repeat protein (DARPin) 9_29. DARPin 9_29 was labeled with iodine-125 by direct radioiodination and with [99mTc]Tc(CO)3 using the C-terminal hexahistidine tag. DARPin 9_29 preserved high specificity and affinity of binding to HER2-expressing cells after labeling. Uptake of [125I]I-DARPin 9_29 and [99mTc]Tc(CO)3-DARPin 9_29 in HER2-positive SKOV-3 xenografts in mice at 6 h after injection was 3.4 ± 0.7 %ID/g and 2.9 ± 0.7 %ID/g, respectively. This was significantly (p < 0.00005) higher than the uptake of the same probes in HER2-negative Ramos lymphoma xenografts, 0.22 ± 0.09 %ID/g and 0.30 ± 0.05 %ID/g, respectively. Retention of [125I]I-DARPin 9_29 in the lung, liver, spleen, and kidneys was appreciably lower compared with [99mTc]Tc(CO)3-DARPin 9_29, which resulted in significantly (p < 0.05) higher tumor-to-organ ratios. The biodistribution data were confirmed by SPECT/CT imaging. In conclusion, radioiodine is a preferable label for DARPin 9_29.


Asunto(s)
Radioisótopos de Yodo , Imagen Molecular/métodos , Radiofármacos/normas , Receptor ErbB-2/análisis , Tecnecio , Animales , Repetición de Anquirina , Neoplasias de la Mama/química , Neoplasias de la Mama/diagnóstico por imagen , Unión Esofagogástrica/patología , Xenoinjertos , Humanos , Radioisótopos de Yodo/farmacocinética , Ratones , Imagen Molecular/normas , Neoplasias/química , Neoplasias/diagnóstico por imagen , Radiofármacos/farmacocinética , Tecnecio/farmacocinética , Distribución Tisular
17.
Clin Cancer Res ; 24(24): 6288-6299, 2018 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-30054278

RESUMEN

PURPOSE: Radiomics is the extraction of multidimensional imaging features, which when correlated with genomics, is termed radiogenomics. However, radiogenomic biological validation is not sufficiently described in the literature. We seek to establish causality between differential gene expression status and MRI-extracted radiomic-features in glioblastoma. EXPERIMENTAL DESIGN: Radiogenomic predictions and validation were done using the Cancer Genome Atlas and Repository of Molecular Brain Neoplasia Data glioblastoma patients (n = 93) and orthotopic xenografts (OX; n = 40). Tumor phenotypes were segmented, and radiomic-features extracted using the developed radiome-sequencing pipeline. Patients and animals were dichotomized on the basis of Periostin (POSTN) expression levels. RNA and protein levels confirmed RNAi-mediated POSTN knockdown in OX. Total RNA of tumor cells isolated from mouse brains (knockdown and control) was used for microarray-based expression profiling. Radiomic-features were utilized to predict POSTN expression status in patient, mouse, and interspecies. RESULTS: Our robust pipeline consists of segmentation, radiomic-feature extraction, feature normalization/selection, and predictive modeling. The combination of skull stripping, brain-tissue focused normalization, and patient-specific normalization are unique to this study, providing comparable cross-platform, cross-institution radiomic features. POSTN expression status was not associated with qualitative or volumetric MRI parameters. Radiomic features significantly predicted POSTN expression status in patients (AUC: 76.56%; sensitivity/specificity: 73.91/78.26%) and OX (AUC: 92.26%; sensitivity/specificity: 92.86%/91.67%). Furthermore, radiomic features in OX were significantly associated with patients with similar POSTN expression levels (AUC: 93.36%; sensitivity/specificity: 82.61%/95.74%; P = 02.021E-15). CONCLUSIONS: We determined causality between radiomic texture features and POSTN expression levels in a preclinical model with clinical validation. Our biologically validated radiomic pipeline also showed the potential application for human-mouse matched coclinical trials.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/genética , Moléculas de Adhesión Celular/genética , Expresión Génica , Glioblastoma/diagnóstico por imagen , Glioblastoma/genética , Imagen por Resonancia Magnética , Imagen Molecular , Adulto , Anciano , Anciano de 80 o más Años , Animales , Biomarcadores de Tumor , Análisis de Datos , Modelos Animales de Enfermedad , Femenino , Genómica/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Masculino , Ratones , Persona de Mediana Edad , Imagen Molecular/métodos , Imagen Molecular/normas , Ensayos Antitumor por Modelo de Xenoinjerto
18.
Radiologia (Engl Ed) ; 60(4): 332-346, 2018.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29807678

RESUMEN

Imaging in oncology is an essential tool for patient management but its potential is being profoundly underutilized. Each of the techniques used in the diagnostic process also conveys functional information that can be relevant in treatment decision making. New imaging algorithms and techniques enhance our knowledge about the phenotype of the tumor and its potential response to different therapies. Functional imaging can be defined as the one that provides information beyond the purely morphological data, and include all the techniques that make it possible to measure specific physiological functions of the tumor, whereas molecular imaging would include techniques that allow us to measure metabolic changes. Functional and molecular techniques included in this document are based on multi-detector computed tomography (CT), 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET), magnetic resonance imaging (MRI), and hybrid equipments, integrating PET with CT (PET/CT) or MRI (PET-MRI). Lung cancer is one of the most frequent and deadly tumors although survival is increasing thanks to advances in diagnostic methods and new treatments. This increased survival poises challenges in terms of proper follow-up and definitions of response and progression, as exemplified by immune therapy-related pseudoprogression. In this consensus document, the use of functional and molecular imaging techniques will be addressed to exploit their current potential and explore future applications in the diagnosis, evaluation of response and detection of recurrence of advanced NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Imagen Molecular/normas , Carcinoma de Pulmón de Células no Pequeñas/patología , Humanos , Neoplasias Pulmonares/patología , Estadificación de Neoplasias
19.
J Endocrinol Invest ; 41(7): 849-876, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29729004

RESUMEN

BACKGROUND: Thyroid nodules are a common clinical problem, and differentiated thyroid cancer is becoming increasingly prevalent. METHODS: Six scientific Italian societies entitled to cure thyroid cancer patients (the Italian Thyroid Association, the Medical Endocrinology Association, the Italian Society of Endocrinology, the Italian Association of Nuclear Medicine and Molecular Imaging, the Italian Society of Unified Endocrine Surgery and the Italian Society of Anatomic Pathology and Diagnostic Cytology) felt the need to develop a consensus report based on significant scientific advances occurred in the field. OBJECTIVE: The document includes recommendations regarding initial evaluation of thyroid nodules, clinical and ultrasound criteria for fine-needle aspiration biopsy, initial management of thyroid cancer including staging and risk assessment, surgical management, radioiodine remnant ablation, and levothyroxine therapy, short-term and long-term follow-up strategies, and management of recurrent and metastatic disease. The objective of this consensus is to inform clinicians, patients, researchers, and health policy makers about the best strategies (and their limitations) relating to the diagnosis and treatment of differentiated thyroid cancer.


Asunto(s)
Adenocarcinoma/diagnóstico , Adenocarcinoma/terapia , Endocrinología/normas , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/terapia , Biopsia con Aguja Fina/métodos , Biopsia con Aguja Fina/normas , Consenso , Humanos , Italia , Imagen Molecular/métodos , Imagen Molecular/normas , Medicina Nuclear/organización & administración , Medicina Nuclear/normas , Cintigrafía/métodos , Cintigrafía/normas , Sociedades Médicas/organización & administración , Sociedades Médicas/normas , Ultrasonografía/métodos , Ultrasonografía/normas
20.
Prog Neurol Surg ; 30: 12-62, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29241169

RESUMEN

Combined use of contemporary radiological modalities, particularly integration of structural, metabolic, and functional imaging, provides optimal multifaceted information for detailed characterization of intracranial gliomas. It allows differentiation of the tumor from non-neoplastic pathology, its non-invasive histopathological typing and grading, prediction of patient prognosis and clinical course of the disease, detailed planning of surgical resection or biopsy, critical postoperative assessment of the residual lesion, effective surveillance during follow-up with evaluation of effectiveness of the adjuvant therapy and timely identification of recurrence, and even insights into molecular signatures of the neoplasms. Therefore, advanced neuroimaging is one of the most important cornerstones of the modern neuro-oncology.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Glioma/diagnóstico por imagen , Glioma/cirugía , Imagen Multimodal/métodos , Terapia Combinada/métodos , Terapia Combinada/normas , Humanos , Imagen por Resonancia Magnética/métodos , Imagen Molecular/métodos , Imagen Molecular/normas , Imagen Multimodal/normas , Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA