Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.410
Filtrar
Más filtros











Intervalo de año de publicación
1.
Anal Chim Acta ; 1312: 342765, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834279

RESUMEN

The sensitive, accurate and rapid detection of carbohydrate antigen 125 (CA125) is essential for the early diagnosis and clinical management of ovarian cancer, but there is still challenge. Herein, a photoelectrochemical (PEC) immunosensor based on CdS/Bi2S3/NiS ternary sulfide heterostructured photocatalyst was presented for the detection of CA125. The CdS/Bi2S3/NiS was synthesized by a one-step hydrothermal approach. The heterojunction comprising of CdS and Bi2S3 could separate photogenerated carriers, the introduced narrow bandgap NiS could act as electron-conducting bridge to facilitate the transfer of interfacial photogenerated electrons, thereby improving the photoelectric conversion efficiency. Due to their synergistic effect, the photocurrent response produced by the composite was up to 14.6 times of pure CdS. On the basis, a PEC immunosensor was constructed by introducing the CA125 antibody through thioglycolic acid linkage. It was found that the resulting immunosensor showed good performance. Under the optimized conditions, its linear detection range was as wide as 1 pg mL-1-50 ng mL-1, and the detection limit was low to 0.85 pg mL-1. Furthermore, we experimentally tested its anti-interference, stability and reproducibility, and satisfactory results were achieved. The practicable feasibility of the sensor was confirmed by testing serum sample. Thus this work provided a simple, fast and enough sensitive approach for CA125 monitoring.


Asunto(s)
Bismuto , Antígeno Ca-125 , Compuestos de Cadmio , Técnicas Electroquímicas , Sulfuros , Compuestos de Cadmio/química , Sulfuros/química , Humanos , Técnicas Electroquímicas/métodos , Antígeno Ca-125/sangre , Antígeno Ca-125/análisis , Bismuto/química , Límite de Detección , Inmunoensayo/métodos , Técnicas Biosensibles/métodos
2.
Mikrochim Acta ; 191(7): 370, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837084

RESUMEN

The development of an ultrasensitive and precise measurement of a breast cancer biomarker (cancer antigen 15-3; CA15-3) in complex human serum is essential for the early diagnosis of cancer in groups of healthy populations and the treatment of patients. However, currently available testing technologies suffer from insufficient sensitivity toward CA15-3, which severely limits early large-scale screening of breast cancer patients. We report a versatile electrochemical immunoassay method based on atomically cobalt-dispersed nitrogen-doped carbon (Co-NC)-modified disposable screen-printed carbon electrode (SPCE) with alkaline phosphatase (ALP) and its metabolite, ascorbic acid 2-phosphate (AAP), as the electrochemical labeling and redox signaling unit for sensitive detection of low-abundance CA15-3. During electrochemical detection by differential pulse voltammetry (DPV), it was found that the Co-NC-SPCE electrode did not have a current signal response to the AAP substrate; however, it had an extremely favorable response current to ascorbic acid (AA). Based on the above principle, the target CA15-3-triggered immunoassay enriched ALP-catalyzed AAP produces a large amount of AA, resulting in a significant change in the system current signal, thereby realizing the highly sensitive detection of CA15-3. Under the optimal AAP substrate concentration and ALP catalysis time, the Co-NC-SPCE-based electrochemical immunoassay demonstrated a good DPV current for CA15-3 in the assay interval of 1.0 mU/mL to 10,000 mU/mL, with a calculated limit of detection of 0.38 mU/mL. Since Co-NC-SPCE has an excellent DPV current response to AA and employs split-type scheme, the constructed electrochemical immunoassay has the merits of high preciseness and anti-interference, and its clinical diagnostic results are comparable to those of commercial kits.


Asunto(s)
Ácido Ascórbico , Biomarcadores de Tumor , Neoplasias de la Mama , Carbono , Cobalto , Técnicas Electroquímicas , Mucina-1 , Nitrógeno , Humanos , Inmunoensayo/métodos , Neoplasias de la Mama/sangre , Mucina-1/sangre , Biomarcadores de Tumor/sangre , Técnicas Electroquímicas/métodos , Carbono/química , Nitrógeno/química , Cobalto/química , Ácido Ascórbico/química , Ácido Ascórbico/sangre , Ácido Ascórbico/análogos & derivados , Femenino , Límite de Detección , Fosfatasa Alcalina/sangre , Fosfatasa Alcalina/química , Electrodos , Técnicas Biosensibles/métodos
3.
Commun Biol ; 7(1): 677, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38830977

RESUMEN

We present a quantitative sandwich immunoassay for CD63 Extracellular Vesicles (EVs) and a constituent surface cargo, EGFR and its activity state, that provides a sensitive, selective, fluorophore-free and rapid alternative to current EV-based diagnostic methods. Our sensing design utilizes a charge-gating strategy, with a hydrophilic anion exchange membrane functionalized with capture antibodies and a charged silica nanoparticle reporter functionalized with detection antibodies. With sensitivity and robustness enhancement by the ion-depletion action of the membrane, this hydrophilic design with charged reporters minimizes interference from dispersed proteins, thus enabling direct plasma analysis without the need for EV isolation or sensor blocking. With a LOD of 30 EVs/µL and a high relative sensitivity of 0.01% for targeted proteomic subfractions, our assay enables accurate quantification of the EV marker, CD63, with colocalized EGFR by an operator/sample insensitive universal normalized calibration. We analysed untreated clinical samples of Glioblastoma to demonstrate this new platform. Notably, we target both total and "active" EGFR on EVs; with a monoclonal antibody mAb806 that recognizes a normally hidden epitope on overexpressed or mutant variant III EGFR. Analysis of samples yielded an area-under-the-curve (AUC) value of 0.99 and a low p-value of 0.000033, surpassing the performance of existing assays and markers.


Asunto(s)
Receptores ErbB , Vesículas Extracelulares , Glioblastoma , Tetraspanina 30 , Humanos , Glioblastoma/sangre , Glioblastoma/diagnóstico , Glioblastoma/metabolismo , Tetraspanina 30/metabolismo , Receptores ErbB/metabolismo , Vesículas Extracelulares/metabolismo , Inmunoensayo/métodos , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/metabolismo , Neoplasias Encefálicas/sangre , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/diagnóstico
4.
Biosens Bioelectron ; 258: 116351, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38705074

RESUMEN

Multifunctional single-atom catalysts (SACs) have been extensively investigated as outstanding signal amplifiers in bioanalysis field. Herein, a type of Fe single-atom catalysts with Fe-nitrogen coordination sites in nitrogen-doped carbon (Fe-N/C SACs) was synthesized and demonstrated to possess both catalase and peroxidase-like activity. Utilizing Fe-N/C SACs as dual signal amplifier, an efficient bipolar electrode (BPE)-based electrochemiluminescence (ECL) immunoassay was presented for determination of prostate-specific antigen (PSA). The cathode pole of the BPE-ECL platform modified with Fe-N/C SACs is served as the sensing side and luminol at the anode as signal output side. Fe-N/C SACs could catalyze decomposition of H2O2 via their high catalase-like activity and then increase the Faraday current, which can boost the ECL of luminol due to the electroneutrality in a closed BPE system. Meanwhile, in the presence of the target, glucose oxidase (GOx)-Au NPs-Ab2 was introduced through specific immunoreaction, which catalyzes the formation of H2O2. Subsequently, Fe-N/C SACs with peroxidase-like activity catalyze the reaction of H2O2 and 4-chloro-1-naphthol (4-CN) to generate insoluble precipitates, which hinders electron transfer and then inhibits the ECL at the anode. Thus, dual signal amplification of Fe-N/C SACs was achieved by increasing the initial ECL and inhibiting the ECL in the presence of target. The assay exhibits sensitive detection of PSA linearly from 1.0 pg/mL to 100 ng/mL with a detection limit of 0.62 pg/mL. The work demonstrated a new ECL enhancement strategy of SACs via BPE system and expands the application of SACs in bioanalysis field.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Peróxido de Hidrógeno , Hierro , Límite de Detección , Mediciones Luminiscentes , Luminol , Antígeno Prostático Específico , Catálisis , Mediciones Luminiscentes/métodos , Técnicas Electroquímicas/métodos , Peróxido de Hidrógeno/química , Peróxido de Hidrógeno/análisis , Humanos , Luminol/química , Antígeno Prostático Específico/análisis , Antígeno Prostático Específico/sangre , Hierro/química , Glucosa Oxidasa/química , Inmunoensayo/métodos , Oro/química , Peroxidasa/química , Nanopartículas del Metal/química , Nitrógeno/química , Carbono/química , Naftoles
5.
Biosens Bioelectron ; 258: 116372, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38735081

RESUMEN

Epithelial-mesenchymal transition (EMT) promotes tumor cell infiltration and metastasis. Tracking the progression of EMT could potentially indicate early cancer metastasis. A key characteristic of EMT is the dynamic alteration in the molecular levels of E-cadherin and N-cadherin. Traditional assays have limited sensitivity and multiplexing capabilities, relying heavily on cell lysis. Here, we developed a multiplex electrochemical biosensor to concurrently track the upregulation of N-cadherin expression and reduction of E-cadherin in breast cancer cells undergoing EMT. Small-sized gold nanoparticles (Au NPs) tagged with redox probes (thionin or amino ferrocene) and bound to two types of antibodies were used as distinguishable signal tags. These tags specifically recognized E-cadherin and N-cadherin proteins on the tumor cell surface without cross-reactivity. The diphenylalanine dipeptide (FF)/chitosan (CS)/Au NPs (FF-CS@Au) composites with high surface area and good biocompatibility were used as the sensing platforms for efficiently fixing cells and recording the dynamic changes in electrochemical signals of surface proteins. The electrochemical immunosensor allowed for simultaneous monitoring of E- and N-cadherins on breast cancer cell surfaces in a single run, enabling tracking of the EMT dynamic process for up to 60 h. Furthermore, the electrochemical detection results are consistent with Western blot analysis, confirming the reliability of the methodology. This present work provides an effective, rapid, and low-cost approach for tracking the EMT process, as well as valuable insights into early tumor metastasis.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama , Técnicas Electroquímicas , Transición Epitelial-Mesenquimal , Oro , Nanopartículas del Metal , Humanos , Técnicas Biosensibles/métodos , Neoplasias de la Mama/patología , Oro/química , Femenino , Nanopartículas del Metal/química , Técnicas Electroquímicas/métodos , Cadherinas , Línea Celular Tumoral , Inmunoensayo/métodos , Quitosano/química
6.
ACS Appl Mater Interfaces ; 16(20): 25601-25609, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38727578

RESUMEN

We report an ultrasensitive sandwich-type electrochemical immunosensor to detect the breast cancer biomarker CA 15-3. Amine-functionalized composite of reduced graphene oxide and Fe3O4 nanoparticles (MRGO-NH2) was used as an electrochemical sensing platform material to modify the electrodes. The nanocomposite comprising Pt and Fe3O4 nanoparticles (NPs) anchored on multiwalled carbon nanotubes (Pt-Fe3O4-MWCNTs-NH2) was utilized as a pseudoenzymatic signal-amplifying label. Compared to reduced graphene oxide, the composite MRGO-NH2 platform material demonstrated a higher electrochemical signal. In the Pt-Fe3O4-MWCNTs-NH2 label, multiwalled carbon nanotubes provided the substratum to anchor abundant catalytic Pt and Fe3O4 NPs. The nanocomposites were thoroughly characterized using transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy. An electroanalytical study and prevalidation of the immunosensor was carried out. The immunosensor exhibited exceptional capabilities in detecting CA 15-3, offering a wider linear range of 0.0005-100 U mL-1 and a lower detection limit of 0.00008 U mL-1. Moreover, the designed immunosensor showed good specificity, reproducibility, and acceptable stability. The sensor was successfully applied to analyze samples from breast cancer patients, yielding reliable results.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama , Técnicas Electroquímicas , Nanocompuestos , Nanotubos de Carbono , Platino (Metal) , Humanos , Nanotubos de Carbono/química , Neoplasias de la Mama/diagnóstico , Nanocompuestos/química , Técnicas Electroquímicas/métodos , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/sangre , Femenino , Platino (Metal)/química , Técnicas Biosensibles/métodos , Grafito/química , Aminas/química , Mucina-1/análisis , Mucina-1/sangre , Inmunoensayo/métodos , Límite de Detección
7.
J Mycol Med ; 34(2): 101481, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38718721

RESUMEN

Several lateral flow assays (LFA) capable of detecting Aspergillus fumigatus in serum and broncho-alveolar lavage fluid (BALF) within the hour, thereby potentially accelerating the screening process, are now commercially available. We prospectively compared three LFA targeting A. fumigatus on BALF collected from non-surgical intensive care patients between June 2022 and February 2023. The three LFA tested were Sõna Aspergillus galactomannan LFA (Immy), Fungadia Aspergillus antigen (Gadia), and AspLFD (OLM Diagnostics). We compared the results of these LFA with those of the galactomannan (GM) Platelia Aspergillus enzyme immunoassay (Bio-Rad), culture on Sabouraud medium and Aspergillus qPCR. We tested 97 BALF samples from 92 patients. In total 84 BALF samples tested negative with all three LFA, and four BALF samples tested positive with the AspLFD assay only (OLM). Only one BALF sample tested positive with the three LFA. In addition, three BALF samples tested positive only with the GM Platelia immunoassay. Four diagnosis of probable invasive aspergillosis were retained for the 92 patients tested. This prospective series included very few positive samples. From a practical point of view, the LFA from OLM presented the simplest protocol for use.


Asunto(s)
Antígenos Fúngicos , Aspergillus fumigatus , Líquido del Lavado Bronquioalveolar , Galactosa , Aspergilosis Pulmonar Invasiva , Mananos , Humanos , Líquido del Lavado Bronquioalveolar/microbiología , Líquido del Lavado Bronquioalveolar/química , Estudios Prospectivos , Galactosa/análogos & derivados , Antígenos Fúngicos/análisis , Mananos/análisis , Masculino , Femenino , Aspergillus fumigatus/aislamiento & purificación , Persona de Mediana Edad , Aspergilosis Pulmonar Invasiva/diagnóstico , Aspergilosis Pulmonar Invasiva/microbiología , Anciano , Adulto , Tamizaje Masivo/métodos , Sensibilidad y Especificidad , Inmunoensayo/métodos , Anciano de 80 o más Años
8.
Biosens Bioelectron ; 259: 116355, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38754196

RESUMEN

Coronavirus disease 2019 (COVID-19) is a highly contagious illness caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), resulting in a global health crisis. The primary diagnostic method for COVID-19 is quantitative reverse transcription PCR, which is time-consuming and requires expensive instrumentation. Here, we developed an electrochemical biosensor for detecting SARS-CoV-2 biomarkers using a 3D porous polyacrylamide/polyaniline hydrogel (PPG) electrode prepared by UV photopolymerization and in situ polymerization. The electrochemical immunosensor for detecting SARS-CoV-2 N protein via the immune sandwich principle demonstrated a lower detection limit of 42 pg/mL and comparable specificity to a commercial enzyme-linked immunosorbent assay, which was additionally validated in pseudoviruses. The electrochemical sensor for hydrogen peroxide showed a low detection limit of 0.5 µM and excellent selectivity, which was further confirmed in cancer cells under oxidative stress. The biomarkers of SARS-CoV-2 were successfully detected due to the signal amplification capability provided by 3D porous electrodes and the high sensitivity of the antigen-antibody specific binding. This study introduces a novel three-dimensional electrode with great potential for the early detection of SARS-CoV-2.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Técnicas Electroquímicas , Electrodos , Hidrogeles , Peróxido de Hidrógeno , Límite de Detección , SARS-CoV-2 , Peróxido de Hidrógeno/química , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/inmunología , Humanos , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , COVID-19/diagnóstico , COVID-19/virología , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Hidrogeles/química , Proteínas de la Nucleocápside de Coronavirus/análisis , Proteínas de la Nucleocápside de Coronavirus/inmunología , Fosfoproteínas/análisis , Inmunoensayo/instrumentación , Inmunoensayo/métodos
9.
Biosens Bioelectron ; 259: 116388, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38761744

RESUMEN

Claudin18.2 (CLDN18.2) is a tight junction protein often overexpressed in various solid tumors, including gastrointestinal and esophageal cancers, serving as a promising target and potential biomarker for tumor diagnosis, treatment assessment, and prognosis. Despite its significance, no biosensor has been reported to date for the detection of CLDN18.2. Here, we present the inaugural immunosensor for CLDN18.2. In this study, an amine-rich conducting polymer of polymelamine (PM) was electrografted onto different carbon nanomaterial-based screen-printed electrodes (SPEs), including carbon (C), graphene (Gr), graphene oxide (GO), carbon nanotube (CNT), and carbon nanofiber (CNF) via cyclic voltammetry. A comparative study was performed to explore the best material for the preparation of the PM-modified electrodes to be used as in-situ redox substrate for the immunosensor fabrication. The surface chemistry and structural features of pristine and PM-deposited electrodes were analyzed using Raman and scanning electron microscopy (SEM) techniques. Our results showed that the PM deposited on Gr and CNT/SPEs exhibited the most significant and stable redox behavior in PBS buffer. The terminal amine moieties on the PM-modified electrode surfaces were utilized for immobilizing anti-CLDN18.2 monoclonal antibodies via N-ethyl-N'-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide chemistry to construct the electrochemical immunosensor platform. Differential pulse voltammetry-based immunosensing of CLDN18.2 protein on BSA/anti-CLDN18.2/PM-Gr/SPE and BSA/anti-CLDN18.2/PM-CNT/SPE exhibited excellent selectivity against other proteins such as CD1, PDCD1, and ErBb2. The limits of detection of these two immunosensor platforms were calculated to be 7.9 pg/mL and 0.104 ng/mL for the CNT and Gr immunosensors, respectively. This study demonstrated that the PM-modified Gr and CNT electrodes offer promising platforms not only for the reagentless signaling but also for covalent immobilization of biomolecules. Moreover, these platforms offer excellent sensitivity and selectivity for the detection of CLDN18.2 due to its enhanced stable redox activity. The immunosensor demonstrated promising results for the sensitive detection of CLDN18.2 in biological samples, addressing the critical need for early gastric cancer diagnosis.


Asunto(s)
Anticuerpos Inmovilizados , Técnicas Biosensibles , Claudinas , Técnicas Electroquímicas , Electrodos , Grafito , Nanotubos de Carbono , Técnicas Biosensibles/métodos , Humanos , Técnicas Electroquímicas/métodos , Nanotubos de Carbono/química , Inmunoensayo/métodos , Anticuerpos Inmovilizados/química , Grafito/química , Límite de Detección , Carbono/química , Nanoestructuras/química
10.
Anal Methods ; 16(21): 3337-3348, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38738371

RESUMEN

Despite the increasing efforts in improving bone health assessments, current diagnostics suffer from critical shortcomings. The present article therefore describes a multiplex label-free immunosensor designed and validated for the assessment of two bone turnover markers (BTMs), namely beta isomerized C-terminal telopeptide of type I collagen (CTx) and Procollagen I Intact N-Terminal (PINP), the combination of which is needed to illustrate an accurate overview of bone health. The immunosensor was then tested outside and inside of a microsystem, with the aim of becoming compatible with a point of care system fabricated for automated assessment of these biomarkers later-on at patient side. Custom-made monoclonal antibodies were specifically designed for this purpose in order to guarantee the selectivity of the immunosensor. In the final platform, a finger prick blood sample is introduced into the microfluidic manifolds without any need for sample preparation step, making the tool suitable for near patient and outside of the central laboratory applications. The platform was exploited in 30 real blood samples with the results validated using electrochemiluminescence immunoassay. The results revealed the platform was capable of measuring the target analyte with high sensitivity and beyond the recommended clinical reference range for each biomarker (CTx: 104-1028 ng L-1 and PINP: 16-96 µg L-1, correspondingly). They also showed the platform to have a limit of detection of 15 (ng L-1) and 0.66 (µg L-1), a limit of quantification of 49 (ng L-1) and 2.21 (µg L-1), and an inter- and intra-assay coefficient of variance of 5.39-6.97% and 6.81-5.37%, for CTx and PINP respectively, which is comparable with the gold standard. The main advantage of the platform over the state-of-the art was the capability of providing the results for two markers recommended for assessing bone health within 15 minutes and without the need for skilled personnel or costly infrastructure.


Asunto(s)
Biomarcadores , Remodelación Ósea , Colágeno Tipo I , Fragmentos de Péptidos , Procolágeno , Humanos , Biomarcadores/sangre , Biomarcadores/análisis , Procolágeno/sangre , Colágeno Tipo I/sangre , Remodelación Ósea/fisiología , Fragmentos de Péptidos/sangre , Inmunoensayo/métodos , Péptidos/sangre , Técnicas Biosensibles/métodos , Sistemas de Atención de Punto
11.
Anal Chem ; 96(21): 8365-8372, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38717986

RESUMEN

Simultaneous sensitive and precise determination of multibiomarkers is of great significance for improving detection efficiency, reducing diagnosis and treatment expenses, and elevating survival rates. However, the development of simple and portable biosensors for simultaneous determination of multiplexed targets in biological fluids still faces challenges. Herein, a unique and versatile immobilization-free dual-target electrochemical biosensing platform, which combines distinguishable magnetic signal reporters with buoyancy-magnetism separation, was designed and constructed for simultaneous detection of carcinoembryonic (CEA) and α-fetoprotein (AFP) in intricate biological fluids. To construct such distinguishable magnetic signal reporters with signal transduction, amplification, and output, secondary antibodies of CEA and AFP were respectively functionalized on methylene blue (MB) and 6-(ferrocenyl)hexanethiol (FeC) modified Fe3O4@Au magnetic nanocomposites. Meanwhile, a multifunctional flotation probe with dual target recognition, capture, and isolation capability was prepared by conjugating primary antibodies (Ab1-CEA, Ab1-AFP) to hollow buoyant microspheres. The target antigens of CEA and AFP can trigger a flotation-mediated sandwich-type immunoreaction and capture a certain amount of the distinguishable magnetic signal reporter, which enables the conversion of the target CEA and AFP quantities to the signal of the potential-resolved MB and FeC. Thus, the MB and FeC currents of magnetically adsorbed distinguishable magnetic reporters can be used to determine the CEA and AFP targets simultaneously and precisely. Accordingly, the proposed strategy exhibited a delightful linear response for CEA and AFP in the range of 100 fg·mL-1-100 ng·mL-1 with detection limits of 33.34 and 17.02 fg·mL-1 (S/N = 3), respectively. Meanwhile, no significant nonspecific adsorption and cross-talk were observed. The biosensing platform has shown satisfactory performance in the determination of real clinical samples. More importantly, the proposed approach can be conveniently extended to universal detection just by simply substituting biorecognition events. Thus, this work opens up a new promising perspective for dual and even multiple targets and offers promising potential applications in clinical diagnosis.


Asunto(s)
Técnicas Biosensibles , Antígeno Carcinoembrionario , Técnicas Electroquímicas , alfa-Fetoproteínas , alfa-Fetoproteínas/análisis , alfa-Fetoproteínas/inmunología , Antígeno Carcinoembrionario/análisis , Antígeno Carcinoembrionario/inmunología , Técnicas Biosensibles/métodos , Humanos , Inmunoensayo/métodos , Oro/química , Límite de Detección
12.
Anal Chem ; 96(21): 8740-8746, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38722256

RESUMEN

Pressure and temperature, as common physical parameters, are important for monitoring human health. In contrast, single-mode monitoring is prone to causing experimental errors. Herein, we innovatively designed a dual-mode flexible sensing platform based on a platinum/zinc-meso-tetrakis(4-carboxyphenyl)porphyrin (Pt/Zn-TCPP) nanozyme for the quantitative monitoring of carcinoembryonic antigen (CEA) in biological fluids with pressure and temperature readouts. The Pt/Zn-TCPP nanozyme with catalytic and photothermal efficiencies was synthesized by means of integrating photosensitizers into porous materials. The flexible sensing system after the antigen-antibody reaction recognized the pressure using a flexible skin-like pressure sensor with a digital multimeter readout, whereas the temperature was acquired via the photoheat conversion system of the Pt/Zn-TCPP nanozyme under 808 nm near-infrared (NIR) irradiation using a portable NIR imaging camera on a smartphone. Meanwhile, the dual-mode flexible sensing system was carried out on a homemade three-dimensional (3D)-printed device. Results revealed that the developed dual-mode immunosensing platform could exhibit good pressure and temperature responses within the dynamic range of 0.5-100 ng mL-1 CEA with the detection limits of 0.24 and 0.13 ng mL-1, respectively. In addition, the pressure and temperature were sensed simultaneously without crosstalk interference. Importantly, the dual-mode flexible immunosensing system can effectively avoid false alarms during the measurement, thus providing great potential for simple and low-cost development for point-of-care testing.


Asunto(s)
Antígeno Carcinoembrionario , Platino (Metal) , Presión , Temperatura , Zinc , Platino (Metal)/química , Inmunoensayo/métodos , Zinc/química , Antígeno Carcinoembrionario/análisis , Humanos , Porfirinas/química , Nanoestructuras/química , Límite de Detección
13.
Anal Chem ; 96(21): 8665-8673, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38722711

RESUMEN

Prostate-specific antigen (PSA) is a key marker for a prostate cancer diagnosis. The low sensitivity of traditional lateral flow immunoassay (LFIA) methods makes them unsuitable for point-of-care testing. Herein, we designed a nanozyme by in situ growth of Prussian blue (PB) within the pores of dendritic mesoporous silica (DMSN). The PB was forcibly dispersed into the pores of DMSN, leading to an increase in exposed active sites. Consequently, the atom utilization is enhanced, resulting in superior peroxidase (POD)-like activity compared to that of cubic PB. Antibody-modified DMSN@PB nanozymes serve as immunological probes in an enzymatic-enhanced colorimetric and photothermal dual-signal LFIA for PSA detection. After systematic optimization, the LFIA based on DMSN@PB successfully achieves a 4-fold amplification of the colorimetric signal within 7 min through catalytic oxidation of the chromogenic substrate by POD-like activity. Moreover, DMSN@PB exhibits an excellent photothermal conversion ability under 808 nm laser irradiation. Accordingly, photothermal signals are introduced to improve the anti-interference ability and sensitivity of LFIA, exhibiting a wide linear range (1-40 ng mL-1) and a low PSA detection limit (0.202 ng mL-1), which satisfies the early detection level of prostate cancer. This research provides a more accurate and reliable visualization analysis methodology for the early diagnosis of prostate cancer.


Asunto(s)
Colorimetría , Ferrocianuros , Nanocompuestos , Antígeno Prostático Específico , Antígeno Prostático Específico/análisis , Ferrocianuros/química , Inmunoensayo/métodos , Humanos , Nanocompuestos/química , Masculino , Límite de Detección , Neoplasias de la Próstata/diagnóstico , Dióxido de Silicio/química , Porosidad
14.
Biosens Bioelectron ; 258: 116347, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38723332

RESUMEN

Monitoring drug efficacy is significant in the current concept of companion diagnostics in metastatic breast cancer. Trastuzumab, a drug targeting human epidermal growth factor receptor 2 (HER2), is an effective treatment for metastatic breast cancer. However, some patients develop resistance to this therapy; therefore, monitoring its efficacy is essential. Here, we describe a deep learning-assisted monitoring of trastuzumab efficacy based on a surface-enhanced Raman spectroscopy (SERS) immunoassay against HER2-overexpressing mouse urinary exosomes. Individual Raman reporters bearing the desired SERS tag and exosome capture substrate were prepared for the SERS immunoassay; SERS tag signals were collected to prepare deep learning training data. Using this deep learning algorithm, various complicated mixtures of SERS tags were successfully quantified and classified. Exosomal antigen levels of five types of cell-derived exosomes were determined using SERS-deep learning analysis and compared with those obtained via quantitative reverse transcription polymerase chain reaction and western blot analysis. Finally, drug efficacy was monitored via SERS-deep learning analysis using urinary exosomes from trastuzumab-treated mice. Use of this monitoring system should allow proactive responses to any treatment-resistant issues.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Neoplasias de la Mama , Aprendizaje Profundo , Exosomas , Receptor ErbB-2 , Espectrometría Raman , Trastuzumab , Trastuzumab/uso terapéutico , Animales , Exosomas/química , Femenino , Ratones , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/orina , Espectrometría Raman/métodos , Humanos , Biomarcadores de Tumor/orina , Inmunoensayo/métodos , Antineoplásicos Inmunológicos/uso terapéutico
15.
Anal Chem ; 96(21): 8814-8821, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38751335

RESUMEN

Highly responsive interface of semiconductor nanophotoelectrochemical materials provides a broad development prospect for the identification of low-abundance cancer marker molecules. This work innovatively proposes an efficient blank WO3/SnIn4S8 heterojunction interface formed by self-assembly on the working electrode for interface regulation and photoregulation. Different from the traditional biomolecular layered interface, a hydrogel layer containing manganese dioxide with a wide light absorption range is formed at the interface after an accurate response to external immune recognition. The formation of the hydrogel layer hinders the effective contact between the heterojunction interface and the electrolyte solution, and manganese dioxide in the hydrogel layer forms a strong competition between the light source and the substrate photoelectric material. The process effectively improves the carrier recombination efficiency at the interface, reduces the interface reaction kinetics and photoelectric conversion efficiency, and thus provides strong support for target identification. Taking advantage of the process, the resulting biosensors are being explored for sensitive detection of human epidermal growth factor receptor 2, with a limit of detection as low as 0.037 pg/mL. Also, this study contributes to the advancement of photoelectrochemical biosensing technology and opens up new avenues for the development of sensitive and accurate analytical tools in the field of bioanalysis.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Compuestos de Manganeso , Óxidos , Receptor ErbB-2 , Humanos , Técnicas Electroquímicas/métodos , Óxidos/química , Compuestos de Manganeso/química , Receptor ErbB-2/inmunología , Receptor ErbB-2/metabolismo , Hidrogeles/química , Procesos Fotoquímicos , Límite de Detección , Electrodos , Inmunoensayo/métodos , Tungsteno/química
16.
Anal Chem ; 96(21): 8837-8843, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38757510

RESUMEN

Breast cancer poses the significance of early diagnosis and treatment. Here, we developed an innovative photoelectrochemical (PEC) immunosensor characterized by high-level dual photocurrent signals and exceptional sensitivity. The PEC sensor, denoted as MIL&Ag2S, was constructed by incorporating Ag2S into a metal-organic framework of MIL-101(Cr). This composite not only enhanced electron-hole separation and conductivity but also yielded robust and stable dual photocurrent signals. Through the implementation of signal switching, we achieved the combined detection of cancer antigen 15-3 (CA15-3) and carcinoembryonic antigen (CEA) with outstanding stability, reproducibility, and specificity. The results revealed a linear range for CEA detection spanning 0.01-32 ng/mL, with a remarkably low detection limit of 0.0023 ng/mL. Similarly, for CA15-3 detection, the linear range extended from 0.1 to 320 U/mL, with a low detection limit of 0.014 U/mL. The proposed strategy introduces new avenues for the development of highly efficient, cost-effective, and user-friendly PEC sensors. Furthermore, it holds promising prospects for early clinical diagnosis, contributing to potential breakthroughs in medical detection and ultimately improving patient outcomes.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama , Antígeno Carcinoembrionario , Técnicas Electroquímicas , Estructuras Metalorgánicas , Mucina-1 , Compuestos de Plata , Estructuras Metalorgánicas/química , Humanos , Neoplasias de la Mama/diagnóstico , Antígeno Carcinoembrionario/sangre , Antígeno Carcinoembrionario/análisis , Mucina-1/análisis , Mucina-1/sangre , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/análisis , Compuestos de Plata/química , Inmunoensayo/métodos , Técnicas Biosensibles , Femenino , Límite de Detección , Procesos Fotoquímicos , Anticuerpos Inmovilizados/inmunología , Anticuerpos Inmovilizados/química
17.
Talanta ; 275: 126186, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38703482

RESUMEN

Detection of procalcitonin (PCT) is crucial for the early identification of sepsis. PCT is primarily utilized in the multiple diagnosis of bacterial and viral illnesses along with to guide the application of antibiotics. Considering their advantages of high specificity and straightforward usage, electrochemical immunosensors offer significant application prospects in the detection of disease indicators. A dual-mode electrochemical immunosensor was constructed in this study to reliably identify PCT. In light of the synergistic effect of the dual-MOF derived heterostructure, the immunosensor demonstrating excellent square wave voltammetry (SWV) signals as well as significant catalytic activity for the H2O2 redox process. In addition to maintaining a low detection limit (SWV: 0.31 fg/mL and i-t: 0.098 fg/mL), the immunosensor offers an extensive linear response range (0.000001-100 ng/mL). The excellent performance is on account of the introduction of the local on-site sulfurized dual-MOF heterostructure with abundant metal chalcogenides/MOF interfaces, which boosts the specific surface area, offers an abundance of active sites, enhances conductivity, and raises catalytic activity. Furthermore, the immunosensor exhibits outstanding specificity, stability and reproducibility for the determination of PCT in serum, which is of great crucial for the clinical screening and diagnosis of sepsis.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Límite de Detección , Estructuras Metalorgánicas , Polipéptido alfa Relacionado con Calcitonina , Polipéptido alfa Relacionado con Calcitonina/sangre , Estructuras Metalorgánicas/química , Humanos , Inmunoensayo/métodos , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/química
18.
Sci Rep ; 14(1): 10450, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714678

RESUMEN

We present an advanced electrochemical immunosensor designed to detect the vascular endothelial growth factor (VEGF) precisely. The sensor is constructed on a modified porous gold electrode through a fabrication process involving the deposition of silver and gold on an FTO substrate. Employing thermal annealing and a de-alloying process, the silver is eliminated from the electrode, producing a reproducible porous gold substrate. Utilizing a well-defined protocol, we immobilize the heavy-chain (VHH) antibody against VEGF on the gold substrate, facilitating VEGF detection through various electrochemical methods. Remarkably, this immunosensor performs well, featuring an impressive detection limit of 0.05 pg/mL and an extensive linear range from 0.1 pg/mL to 0.1 µg/mL. This emphasizes it's to measure biomarkers across a wide concentration spectrum precisely. The robust fabrication methodology in this research underscores its potential for widespread application, offering enhanced precision, reproducibility, and remarkable detection capabilities for the developed immunosensor.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Oro , Factor A de Crecimiento Endotelial Vascular , Oro/química , Humanos , Biomarcadores de Tumor/análisis , Factor A de Crecimiento Endotelial Vascular/análisis , Técnicas Biosensibles/métodos , Inmunoensayo/métodos , Nanopartículas del Metal/química , Nanoestructuras/química , Técnicas Electroquímicas/métodos , Límite de Detección , Detección Precoz del Cáncer/métodos , Reproducibilidad de los Resultados , Neoplasias/diagnóstico
19.
Colloids Surf B Biointerfaces ; 239: 113963, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759294

RESUMEN

Among various biomimetic polymer materials, polydimethylsiloxane (PDMS) stands out as an ideal matrix for surface-enhanced Raman scattering (SERS) due to its unique intrinsic Raman signal and tenacity. In order to realize the precise detection of prostate-specific antigen (PSA), we proposed a sandwich-type SERS-active immunostructure composed of PDMS@silver nanoparticles (Ag NPs)@ZIF-67 biomimetic film as the immunosubstrate and gold nanorods (Au NRs) as immunoprobes. Due to the synergistic effect of electromagnetic enhancement facilitated by biomimetic surfaces and chemical enhancement achieved by ZIF-67, this structure enabled an ultrasensitive and selective detection of PSA across a broad range from 10-3 to 10-9 mg/mL. The achieved limit of detection was as low as 3.0 × 10-10 mg/mL. Particularly, the intrinsic Raman signal of PDMS matrix at 2905 cm-1 was employed as a potential internal standard (IS) in the detection, achieving a high coefficient of determination (R2) value of 0.996. This multifunctional SERS substrate-mediated immunoassay holds vast potential for early diagnosis of prostate cancer, offering promising prospects for clinical applications.


Asunto(s)
Dimetilpolisiloxanos , Nanopartículas del Metal , Antígeno Prostático Específico , Plata , Espectrometría Raman , Plata/química , Espectrometría Raman/métodos , Inmunoensayo/métodos , Antígeno Prostático Específico/análisis , Nanopartículas del Metal/química , Dimetilpolisiloxanos/química , Humanos , Oro/química , Materiales Biomiméticos/química , Propiedades de Superficie , Límite de Detección , Nanotubos/química , Masculino , Tamaño de la Partícula , Imidazoles , Zeolitas
20.
J Proteome Res ; 23(6): 2013-2027, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38739617

RESUMEN

The human relaxins belong to the Insulin/IGF/Relaxin superfamily of peptide hormones, and their physiological function is primarily associated with reproduction. In this study, we focused on a prostate tissue-specific relaxin RLN1 (REL1_HUMAN protein) and a broader tissue specificity RLN2 (REL2_HUMAN protein). Due to their structural similarity, REL1 and REL2 proteins were collectively named a 'human relaxin protein' in previous studies and were exclusively measured by immunoassays. We hypothesized that the highly selective and sensitive immunoaffinity-selected reaction monitoring (IA-SRM) assays would reveal the identity and abundance of the endogenous REL1 and REL2 in biological samples and facilitate the evaluation of these proteins for diagnostic applications. High levels of RLN1 and RLN2 transcripts were found in prostate and breast cancer cell lines by RT-PCR. However, no endogenous prorelaxin-1 or mature REL1 were detected by IA-SRM in cell lines, seminal plasma, or blood serum. The IA-SRM assay of REL2 demonstrated its undetectable levels (<9.4 pg/mL) in healthy control female and male sera and relatively high levels of REL2 in maternal sera across different gestational weeks (median 331 pg/mL; N = 120). IA-SRM assays uncovered potential cross-reactivity and nonspecific binding for relaxin immunoassays. The developed IA-SRM assays will facilitate the investigation of the physiological and pathological roles of REL1 and REL2 proteins.


Asunto(s)
Relaxina , Humanos , Relaxina/metabolismo , Relaxina/genética , Masculino , Femenino , Línea Celular Tumoral , Inmunoensayo/métodos , Espectrometría de Masas/métodos , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/genética , Neoplasias de la Próstata/diagnóstico , Semen/química , Semen/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA