Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.187
Filtrar
Más filtros











Intervalo de año de publicación
1.
AIDS Behav ; 28(7): 2314-2320, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38814407

RESUMEN

Globally, men are less likely to access HIV services, and addressing HIV service challenges among men is crucial to the global HIV/AIDS response. HIV self-testing (HIVST) has been shown to be a potentially effective strategy in improving HIV testing coverage among men. This study assessed and identified factors influencing willingness to receive HIVST kits from sexual partners among men in Tanzania. Data are from the baseline survey of the Self-Testing Education and Promotion (STEP) project, a five-year study comprising male participants aged 18 or older who self-reported as HIV-negative. Logistic regression models were used to assess factors associated with men's willingness to receive HIVST kits from their sexual partners. There were 505 heterosexual male participants enrolled in the study with an average age of 29 years, of whom 69% reported being willing to receive HIVST kits from their sexual partner. Logistic regression models demonstrated that willingness to receive HIVST kits from sexual partners was significantly associated with number of sexual partners within 12 months (aOR = 1.2, 95% CI [1.1-1.3]), awareness of HIVST (aOR = 5.6, 95% CI [3.2-9.5]), previous discussion of HIVST with sexual partners aOR = 14.0, 95% CI [8.0-24.6]), and previous testing for HIV with sexual partners not (aOR = 2.5, 95% CI [1.3-4.7]). These findings suggest additional promotional strategies to improve men's awareness of HIVST and support open conversations about HIVST and HIV testing with sexual partners could improve men's willingness to receive HIVST kits when distributed through their sexual partners.


Asunto(s)
Infecciones por VIH , Prueba de VIH , Aceptación de la Atención de Salud , Autoevaluación , Parejas Sexuales , Humanos , Masculino , Tanzanía/epidemiología , Parejas Sexuales/psicología , Adulto , Infecciones por VIH/diagnóstico , Infecciones por VIH/psicología , Aceptación de la Atención de Salud/psicología , Aceptación de la Atención de Salud/estadística & datos numéricos , Prueba de VIH/estadística & datos numéricos , Adulto Joven , Conocimientos, Actitudes y Práctica en Salud , Modelos Logísticos , Adolescente , Encuestas y Cuestionarios , Persona de Mediana Edad , Juego de Reactivos para Diagnóstico , Tamizaje Masivo/métodos , Conducta Sexual , Factores Socioeconómicos
2.
Ann Clin Lab Sci ; 54(2): 239-245, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38802145

RESUMEN

OBJECTIVE: Human papillomavirus (HPV) is a double-stranded DNA virus that belongs to the papillomavirus family. High-risk (HR) genotypes of HPV are associated with cervical cancer. The combination of molecular HPV testing and cytology results in an increased detection of high-grade cervical lesions. This study compares the performance of a newly developed MolecuTech Real HPV 16/18/HR assay to that of the cobas HPV assay and Onclarity HPV Assay in Korea. METHODS: A SurePath liquid-based cytology device (BD diagnostics, NC, USA) was used to prospectively collect cervical swab specimens. Onclarity HPV Assay (Onclarity; BD diagnostics), Cobas 4800 HPV Test (Cobas; Roche, Rotkreuz, Switzerland), and MolecuTech Real HPV 16/18/HR (MolecuTech; YD, Yongin, Korea) were performed to detect HPV genotypes. RESULTS: Of the 438 cervical specimens, 13.7% showed the HR-HPV genotype. The concordance rates between Onclarity and MolecuTech, cobas and MolecuTech, and Onclarity and Cobas were 94.9% (kappa=0.754), 95.7% (kappa=0.768), and 95.5% (kappa=0.791), respectively. Moreover, no statistically significant differences in HPV genotyping results were observed in the cytology-positive specimens. CONCLUSIONS: The MolecuTech Real HPV 16/18/HR assay showed good agreement in the detection of HR HPV genotypes, and similar analytical performance for the detection of HR HPV genotypes in samples with abnormal cytological findings.


Asunto(s)
ADN Viral , Infecciones por Papillomavirus , Humanos , Femenino , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , ADN Viral/genética , ADN Viral/análisis , Genotipo , Adulto , Persona de Mediana Edad , Neoplasias del Cuello Uterino/virología , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/patología , Papillomaviridae/genética , Papillomaviridae/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Anciano
3.
Rev Soc Bras Med Trop ; 57: e007052024, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38808801

RESUMEN

BACKGROUND: Accurate diagnosis of paracoccidioidomycosis is crucial for improving patient outcomes. Paracoccidioides antibody detection by double immunodiffusion (DID) is a convenient diagnostic tool, but testing performance can vary based on certain factors. METHODS: We assessed DID performance using a commercially prepared Paracoccidioides reagents (IMMY, USA), involving 40 serum specimens, including 20 from patients with proven paracoccidioidomycosis and 20 from patients without the disease. The DID test demonstrated a sensitivity of 90% (95% CI=68%-99%) and a specificity of 100% (95% CI=83%-100%). CONCLUSIONS: Our findings suggest that DID using commercial reagents may provide a feasible tool with satisfactory testing performance for anti-Paracoccidioides antibody detection.


Asunto(s)
Anticuerpos Antifúngicos , Inmunodifusión , Paracoccidioides , Paracoccidioidomicosis , Sensibilidad y Especificidad , Humanos , Anticuerpos Antifúngicos/sangre , Paracoccidioidomicosis/diagnóstico , Paracoccidioidomicosis/inmunología , Paracoccidioides/inmunología , Juego de Reactivos para Diagnóstico , Femenino , Masculino
4.
J Clin Virol ; 173: 105680, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38728796

RESUMEN

BACKGROUND: Epstein-Barr Virus (EBV) viral loads in hematopoietic stem cell transplant (HSCT) recipients are typically monitored using quantitative molecular assays. The Cobas EBV test (Roche Molecular, Pleasanton, CA) has recently been FDA-cleared for the monitoring of EBV viral loads in plasma samples of transplant patients. In this study, we compared the viral loads obtained by a laboratory-developed test (EBV LDT) using Altona Analyte specific reagents (ASR) to those obtained on the Cobas EBV test. METHODS: The analytical performance of the assay was established using the EBV verification panel from Exact Diagnostics and the EBV ATCC strain B95-8. The clinical evaluation was performed using 343 plasma samples initially tested on the EBV LDT. RESULTS: The analytical sensitivity (<18.8 IU/mL), precision (SD < 0.17 log) and linear range (35.0 IU/mL to 1E + 08 IU/mL) of the Cobas EBV assay established by the manufacturers were confirmed. The strength of the qualitative agreement was substantial between the cobas EBV and the EBV LDT (85.6 %; κ = 0.71) and almost perfect when discordant results were resolved (96.4 %; κ = 0.93). The quantitative agreement was moderate (82.9 %; κ = 0.53) with the viral load obtained on the Cobas EBV test being lower across the linear range of the two tests (mean log difference of 1.0). While the absolute values of the viral loads were markedly different, the overall trends observed in patients with multiple consecutive results were similar between the two tests. CONCLUSIONS: The Cobas EBV test provides an accurate and valid, in vitro diagnostic (IVD) option for monitoring of EBV viral loads in transplant patients and should provide an opportunity for increased standardization and commutability of tests results across laboratories.


Asunto(s)
Infecciones por Virus de Epstein-Barr , Herpesvirus Humano 4 , Sensibilidad y Especificidad , Centros de Atención Terciaria , Carga Viral , Humanos , Carga Viral/métodos , Infecciones por Virus de Epstein-Barr/diagnóstico , Infecciones por Virus de Epstein-Barr/virología , Herpesvirus Humano 4/aislamiento & purificación , Herpesvirus Humano 4/genética , Persona de Mediana Edad , Femenino , Adulto , Masculino , Anciano , Adulto Joven , Adolescente , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Trasplante de Células Madre Hematopoyéticas , Niño , Preescolar , ADN Viral/sangre , Juego de Reactivos para Diagnóstico/normas
5.
Genes (Basel) ; 15(4)2024 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-38674432

RESUMEN

Fecal specimens have long been regarded as promising sources for gastrointestinal cancer screening and have, thus, been extensively investigated in biomarker research. MicroRNAs (miRNAs) are small, non-coding RNA molecules involved in regulating various biological processes. They are commonly dysregulated during tumor development and exhibit differential expression in feces. To assess the preanalytical feasibility of fecal miRNA analysis, we systematically compared the performance of commonly used total RNA extraction methods. Fecal samples from healthy subjects were utilized for this evaluation. Various methods, including miRNeasy, Universal, Trizol, RNeasy, and mirVana kits, were employed to isolate total RNA. MiRNA expression analyses were conducted using TaqMan or SYBR Green qRT-PCR for a subset of miRNAs, with externally spiked-in cel-miR-39 used for normalization. Most methods demonstrated similar performance in terms of the total RNA concentration and purity. Externally spiked cel-miR-39 and endogenous miRNAs (RNU6b, miR-16, and miR-21) exhibited comparable concentrations across the different RNA isolation methods, whereas the RNeasy mini kit consistently yielded lower values. Our findings suggest that various isolation methods produce reproducible and comparable miRNA expression results, supporting the potential comparability and translational applicability of miRNA-based biomarker research in the future.


Asunto(s)
Heces , MicroARNs , Humanos , Heces/química , MicroARNs/genética , MicroARNs/aislamiento & purificación , Juego de Reactivos para Diagnóstico/normas
6.
Lett Appl Microbiol ; 77(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38688871

RESUMEN

The efficiency of PCR-based diagnostic assays can be impacted by the quality of DNA template, and anal samples can be particularly problematic due to the presence of faecal contaminants. Here, we compared the Quick-DNA Viral Kit (Zymo, Zymo Research, CA) and MagNA Pure 96 DNA and Viral NA Small Volume Kit (MP96, Roche) for use of the Seegene Anyplex II HPV28 assay (Anyplex28, Seegene) with anal samples. A total of 94 anal samples extracted using the MP96 and Zymo kits were tested via the Anyplex28, which detects high-risk human papillomavirus (HR-HPV, Panel A) and low-risk (LR-HPV, Panel B) HPV types. Testing the HR-HPV types (Panel A), 86 (91.5%) MP96 and 84 (89.4%) Zymo samples were deemed assessable. Overall agreement between the two methods was 87/94 (92.6%, 95% CI: 85.3-97.0) with the Kappa value of 0.678 (0.5-0.9). Of the 87 assessable samples, 50 (57.5%) were concordant, 34 (39.1%) partially concordant, and 10 (11.5%)discordant. In conclusion, the Anyplex28 produces comparable HPV genotyping results when using DNA extracts from either of these two methods.


Asunto(s)
ADN Viral , Papillomaviridae , Infecciones por Papillomavirus , Humanos , ADN Viral/genética , ADN Viral/aislamiento & purificación , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Papillomaviridae/genética , Papillomaviridae/aislamiento & purificación , Papillomaviridae/clasificación , Reacción en Cadena de la Polimerasa/métodos , Canal Anal/virología , Juego de Reactivos para Diagnóstico
7.
Clin Lab ; 70(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38623659

RESUMEN

BACKGROUND: The purpose of this study is to evaluate the performance of recently developed tumor marker clinical kits in China, with the aim of encouraging local medical technology innovation and thus narrowing the research and development gap with foreign kits. METHODS: The newly established reagent kits were analyzed on the TESMI F3999-Luminex200 flow lattice instrument to verify precision, sensitivity (blank limit), linearity, anti-interference ability, carry-over contamination rate, hook effect, and reference interval verification. Additionally, the newly established reagent kits were compared to other commercially available detection kits (reference reagent kits) to analyze the correlation between the two types of kits. RESULTS: The intra-assay and inter-assay precision had coefficients of variations (CVs) less than 3.50% and 6.91%, respectively. The tumor marker blank limits were lower than the manufacturer's statement. The newly established reagent kits demonstrated excellent linearity (r > 0.99). Rheumatoid factor, triglycerides, bilirubin, and hemoglobin did not have significant interference with the determination of tumor markers. The carry-over contamination rates were all much lower than 3%. At extremely high concentrations of AFP (277,335 ng/mL and 1,031,424 ng/mL), the measured tumor marker values were higher than the upper limit of the linear range and no hook effect occurred. The reference interval was suitable for use in clinical laboratory settings. Correlation analysis indicated a satisfactory relevance and consistency between the newly developed reagent kits and reference reagent kits, with correlation coefficients of r > 0.967 among 654 patients and healthy individuals. CONCLUSIONS: The newly developed reagent kits for tumor markers performed well in all evaluated parameters, having the potential for clinical promotion and application.


Asunto(s)
Biomarcadores de Tumor , Juego de Reactivos para Diagnóstico , Humanos , Fluorescencia , China
8.
J Clin Virol ; 172: 105671, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38518504

RESUMEN

To suit the needs of the human papillomaviruses (HPV) community comprehensively, a range of commercial HPV tests with different performance characteristics are required. Four periodic inventories of commercial HPV molecular tests present in the global market were published previously in 2010, 2012, 2015 and 2020. For the fifth inventory, data were retrieved from internal files and a detailed search using the main bibliographic databases as well as general internet search without period or language restrictions was performed in December 2023. At least 264 distinct HPV tests (and 511 test variants) were available globally in December 2023. A small 2020-2023 net increase in total numbers was observed, but with a strong introduction/withdrawal dynamic: 86 new distinct HPV tests (and 141 variants) were introduced and 76 tests (and 55 variants) were withdrawn from the market in the last four years. Although quality improvement of some tests was recorded, half of all HPV tests are still without a single peer-reviewed publication, and 79 % of tests are without published evidence that demonstrate performance characteristics are in line with requirements agreed in the HPV community. Only a relatively small pool of tests fulfill the operational/performance characteristics required to meet the global cervical cancer screening challenge. Although clinical and analytical performance characteristics of many commercial HPV tests are largely unknown, such tests are used worldwide in daily clinical practice and research, with potentially deleterious consequences. Due to this long-lasting unfavorable situation, significant scope for improvement persists for both manufacturers of HPV tests and the HPV community.


Asunto(s)
Virus del Papiloma Humano , Técnicas de Diagnóstico Molecular , Infecciones por Papillomavirus , Femenino , Humanos , Salud Global , Virus del Papiloma Humano/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Juego de Reactivos para Diagnóstico/normas , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología
9.
Gynecol Oncol ; 184: 67-73, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38290412

RESUMEN

OBJECTIVE: Authors evaluated the performance of a commercially available next-generation sequencing assay kit; this was based on genomic content from Illumina's TruSight™ Oncology 500 research assay that identifies BRCA variants and proprietary algorithms licensed from Myriad and, with additional genomic content, measures the homologous recombination deficiency (HRD) genomic instability score (GIS) in tumor tissue (TSO 500 HRD assay). METHODS: Data from the TSO 500 HRD assay were compared with data from the Myriad MyChoice®CDx PLUS assay (Myriad assay). Prevalence rates for overall HRD status and BRCA mutations (a deleterious or suspected deleterious BRCA1 or BRCA2 mutation or both) and assay agreement rates for HRD GIS and BRCA analysis were assessed in ovarian tumor samples. Pearson correlations of the continuous HRD GIS and analytic sensitivity and specificity were evaluated. RESULTS: The prevalence of overall HRD positivity was 51.2% (TSO 500 HRD assay) versus 49.2% (Myriad assay) and the prevalence of BRCA mutations was 27.6% (TSO 500 HRD assay) versus 25.5% (Myriad assay). After post-processing optimization, concordance of the HRD GIS was 0.980 in all samples and 0.976 in the non-BRCA mutation cohort; the area under the receiver operating characteristic curve was 0.995 and 0.992, respectively. CONCLUSIONS: Comparison between the Illumina and Myriad assays showed that overall HRD status, the individual components of BRCA analysis, and HRD GIS detection results were highly concordant (>93%), suggesting the TSO 500 HRD assay will approach the analytical accuracy of the FDA-approved Myriad assay.


Asunto(s)
Neoplasias Ováricas , Humanos , Femenino , Neoplasias Ováricas/genética , Neoplasias Ováricas/diagnóstico , Recombinación Homóloga , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Estados Unidos/epidemiología , Mutación , Proteína BRCA1/genética , Inestabilidad Genómica , Proteína BRCA2/genética , Juego de Reactivos para Diagnóstico/normas , United States Food and Drug Administration , Persona de Mediana Edad , Genes BRCA1
10.
Anal Biochem ; 672: 115159, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37072098

RESUMEN

Objective To develop a kit for detecting human epidermal growth factor receptor 2 (HER-2) in the human body. Methods The HER-2 kit was evaluated based on an automated magnetic particle chemiluminescence platform. The kit was developed using the double antibody sandwich-complexation method. Results The kit showed a linear range of 0.01-800 ng/mL, with a linear R2 of >0.999. The limit of the blank was 0.0039 ng/mL, and the precision at 1.00 ng/mL was 9.4%. The recovery rate at 10.00 ng/mL was 97.81-101.81%. The negative serum reference range was 0-8.23 ng/mL. Conclusions The kit had a wide linear range, high accuracy, good precision, and high sensitivity, indicating that it has good application prospects.


Asunto(s)
Juego de Reactivos para Diagnóstico , Receptor ErbB-2 , Humanos , Anticuerpos , Inmunoensayo/métodos , Magnetismo , Receptor ErbB-2/sangre
11.
Expert Rev Mol Diagn ; 23(3): 191-198, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36891583

RESUMEN

INTRODUCTION: HIV self-testing (HIVST), whereby an individual performs and interprets their own rapid screening test at home, is another tool to increase the proportion of at-risk individuals who know their status. Globally, HIVST has rapidly been adopted through global partnerships to ensure equitable access to tests in low- and middle-income countries (LMIC). AREA COVERED: This review discusses the regulatory burdens of HIV self-testing within the United States while examining the use of HIV self-tests on a global scale. While the United States only has one approved HIV self-test, numerous tests have been prequalified by the WHO. EXPERT OPINION: Despite the US Food and Drug Administration (FDA) clearance of the first and only self-test in 2012, there have been no other tests that have undergone FDA consideration due to regulatory barriers. This, in turn, has stifled market competition. Despite existing evidence that such programs are an innovative approach to testing hesitant or hard-to-reach populations, high individual test cost and bulky packaging make large-scale, mail-out, and HIV self-testing programs expensive. COVID-19 pandemic has accelerated the public demand for self-testing - HIV self-test programs should capitalize on this to increase the proportion of at-risk people who know their status and are linked to care to contribute to ending the HIV epidemic.


Asunto(s)
COVID-19 , Infecciones por VIH , Humanos , Estados Unidos/epidemiología , VIH , Autoevaluación , Pandemias , Tamizaje Masivo , Juego de Reactivos para Diagnóstico , COVID-19/epidemiología , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología
12.
Clin Chem Lab Med ; 61(4): 608-626, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36716120

RESUMEN

The EU In-Vitro Diagnostic Device Regulation (IVDR) aims for transparent risk-and purpose-based validation of diagnostic devices, traceability of results to uniquely identified devices, and post-market surveillance. The IVDR regulates design, manufacture and putting into use of devices, but not medical services using these devices. In the absence of suitable commercial devices, the laboratory can resort to laboratory-developed tests (LDT) for in-house use. Documentary obligations (IVDR Art 5.5), the performance and safety specifications of ANNEX I, and development and manufacture under an ISO 15189-equivalent quality system apply. LDTs serve specific clinical needs, often for low volume niche applications, or correspond to the translational phase of new tests and treatments, often extremely relevant for patient care. As some commercial tests may disappear with the IVDR roll-out, many will require urgent LDT replacement. The workload will also depend on which modifications to commercial tests turns them into an LDT, and on how national legislators and competent authorities (CA) will handle new competences and responsibilities. We discuss appropriate interpretation of ISO 15189 to cover IVDR requirements. Selected cases illustrate LDT implementation covering medical needs with commensurate management of risk emanating from intended use and/or design of devices. Unintended collateral damage of the IVDR comprises loss of non-profitable niche applications, increases of costs and wasted resources, and migration of innovative research to more cost-efficient environments. Taking into account local specifics, the legislative framework should reduce the burden on and associated opportunity costs for the health care system, by making diligent use of existing frameworks.


Asunto(s)
Servicios de Laboratorio Clínico , Juego de Reactivos para Diagnóstico , Humanos , Juego de Reactivos para Diagnóstico/normas , Unión Europea , Servicios de Laboratorio Clínico/legislación & jurisprudencia
13.
J Acquir Immune Defic Syndr ; 90(S1): S105-S113, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35703762

RESUMEN

OBJECTIVE: To determine the feasibility, acceptability, and implementation of a HIV self-test (HIVST) program through PrEP clients' social and sexual networks. BACKGROUND: HIV testing is critical for treatment and prevention engagement. HIVST kits can overcome barriers to testing. A negative result is an opportunity to provide PrEP information. We describe implementation factors associated with engaging current Mobile PrEP (MP) clients to distribute HIVST kits and PrEP information through their networks. SETTING: Community venues in Miami-Dade County, Florida. METHODS: A baseline survey collected network information and explored distribution plans for offering HIVST kits. A follow-up survey evaluated use and distribution. A logic model describes the process of implementation and evaluation. Up to 4 Ora-Quick HIV ST kits were offered to 81 MP clients. A brief training included resources for posttest engagement. RESULTS: Forty-four percent of the kits were reported as distributed. Of 81 MP clients offered kits, 50 (62%) accepted. In a follow-up survey, 77% of MP clients distributed at least 1 kit. Fifty-six (86%) social network members were Latino, and 9 (14%) were Black. Three of 4 MP clients engaged in PrEP discussions (77%) with SN members. Reported reasons for HIVST kit use included convenience, confidentiality, privacy concerns, and discomfort with going to a testing site. MP clients reported that kit distribution was affected by the COVID-19 pandemic. CONCLUSION: HIV ST kits allowed PrEP users to engage others in their social and sexual networks for HIV testing and information regarding PrEP. Work to scale-up this intervention is underway.


Asunto(s)
COVID-19 , Infecciones por VIH , Estudios de Factibilidad , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología , Infecciones por VIH/prevención & control , Prueba de VIH , Humanos , Tamizaje Masivo , Pandemias , Juego de Reactivos para Diagnóstico , Autoevaluación
14.
PLoS Med ; 19(3): e1003930, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35235573

RESUMEN

BACKGROUND: Low syphilis testing uptake is a major public health issue among men who have sex with men (MSM) in many low- and middle-income countries. Syphilis self-testing (SST) may complement and extend facility-based testing. We aimed to evaluate the effectiveness and costs of providing SST on increasing syphilis testing uptake among MSM in China. METHODS AND FINDINGS: An open-label, parallel 3-arm randomized controlled trial (RCT) was conducted between January 7, 2020 and July 17, 2020. Men who were at least 18 years of age, had condomless anal sex with men in the past year, reported not testing for syphilis in the last 6 months, and had a stable residence with mailing addresses were recruited from 124 cities in 26 Chinese provinces. Using block randomization with blocks of size 12, enrolled participants were randomly assigned (1:1:1) into 3 arms: standard of care arm, standard SST arm, and lottery incentivized SST arm (1 in 10 chance to win US$15 if they had a syphilis test). The primary outcome was the proportion of participants who tested for syphilis during the trial period and confirmed with photo verification and between arm comparisons were estimated with risk differences (RDs). Analyses were performed on a modified intention-to-treat basis: Participants were included in the complete case analysis if they had initiated at least 1 follow-up survey. The Syphilis/HIV Duo rapid test kit was used. A total of 451 men were enrolled. In total, 136 (90·7%, 136/150) in the standard of care arm, 142 (94·0%, 142/151) in the standard of SST arm, and 137 (91·3%, 137/150) in the lottery incentivized SST arm were included in the final analysis. The proportion of men who had at least 1 syphilis test during the trial period was 63.4% (95% confidence interval [CI]: 55.5% to 71.3%, p = 0.001) in the standard SST arm, 65.7% (95% CI: 57.7% to 73.6%, p = 0.0002) in the lottery incentivized SST arm, and 14.7% (95% CI: 8.8% to 20.7%, p < 0.001) in the standard of care arm. The estimated RD between the standard SST and standard of care arm was 48.7% (95% CI: 37.8% to 58.4%, p < 0.001). The majority (78.5%, 95% CI: 72.7% to 84.4%, p < 0.001) of syphilis self-testers reported never testing for syphilis. The cost per person tested was US$26.55 for standard SST, US$28.09 for the lottery incentivized SST, and US$66.19 for the standard of care. No study-related adverse events were reported during the study duration. Limitation was that the impact of the Coronavirus Disease 2019 (COVID-19) restrictions may have accentuated demand for decentralized testing. CONCLUSIONS: Compared to standard of care, providing SST significantly increased the proportion of MSM testing for syphilis in China and was cheaper (per person tested). TRIAL REGISTRATION: Chinese Clinical Trial Registry: ChiCTR1900022409.


Asunto(s)
Infecciones por VIH/diagnóstico , Homosexualidad Masculina , Participación del Paciente/métodos , Autoevaluación , Sífilis/diagnóstico , Adolescente , Adulto , COVID-19/epidemiología , China/epidemiología , Estudios de Seguimiento , Infecciones por VIH/prevención & control , Accesibilidad a los Servicios de Salud/organización & administración , Homosexualidad Masculina/estadística & datos numéricos , Humanos , Inmunoensayo/métodos , Masculino , Tamizaje Masivo/economía , Tamizaje Masivo/métodos , Tamizaje Masivo/organización & administración , Persona de Mediana Edad , Motivación , Pandemias , Juego de Reactivos para Diagnóstico/economía , Juego de Reactivos para Diagnóstico/provisión & distribución , SARS-CoV-2 , Minorías Sexuales y de Género/estadística & datos numéricos , Sífilis/epidemiología , Sífilis/prevención & control , Adulto Joven
15.
Am J Clin Pathol ; 158(2): 206-211, 2022 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-35285877

RESUMEN

OBJECTIVES: Various preanalytical factors, including the collection tube, storage conditions, and centrifugation, affect the detection results of plasma cell-free DNA (cfDNA). We compared the effect of different centrifugation protocols on the detection of EGFR mutations in cfDNA. METHODS: We analyzed 117 plasma specimens from 110 patients with non-small cell lung cancer using the cobas EGFR Mutation Test v2 (Roche Diagnostics). We compared the identified EGFR mutations and semiquantitative index values from the 1- and 2-step centrifugation groups and confirmed the clinical impact of differences in the results after further high-speed centrifugation. RESULTS: We detected EGFR mutations in 44 (37.6%) and 47 (40.2%) samples that were centrifuged once and twice, respectively; the 2 groups showed an 89.7% (105/117) concordance and a strong correlation in their semiquantitative index values (r = 0.929). Among the 12 inconsistent result pairs, 9 samples of 2-step centrifugation (75%) were consistent with the results of a recent tissue biopsy. CONCLUSIONS: Additional high-speed centrifugation has been shown to increase the sensitivity of EGFR mutation detection in a commercial in vitro diagnostic real-time polymerase chain reaction device and is an optimal preanalytical factor for detecting low-allele frequency gene mutations using low concentrations of cfDNA.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Ácidos Nucleicos Libres de Células , Neoplasias Pulmonares , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Ácidos Nucleicos Libres de Células/genética , Centrifugación , Receptores ErbB/genética , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Mutación , Juego de Reactivos para Diagnóstico
16.
Artículo en Chino | MEDLINE | ID: mdl-35266355

RESUMEN

OBJECTIVE: To evaluate the diagnostic efficiency of four anti-cysticercus IgG, IgG4 or IgM antibody test kits (enzyme-linked immunosorbent assay, ELISA) by different manufacturers, so as to provide insights into the epidemiological investigation and clinical detection of cysticercosis. METHODS: Forty serum samples from cerebral cysticercosis patients, 100 serum samples from healthy volunteers, 30 serum samples from paragonimiasis skrjabini patients, 17 serum samples from cystic echinococcosis and 19 serum samples from subcutaneous or cerebral sparganosis patients were collected and detected using anti-cysticercus IgG, IgG4 or IgM antibody test kits (brand A) and the anti-cysticercus IgG antibody test kit (brand B). The sensitivity, specificity and false negative rate of the four kits for detection of cysticercosis were estimated. RESULTS: The anti-cysticercus IgG, IgG4 or IgM antibody test kits (brand A) showed 95.00% (38/40), 87.50% (35/40), 7.50% (3/40) sensitivities and 98.00% (98/100), 100.00% (100/100) and 100.00% (100/100) for detection of cysticercosis, while the anti-cysticercus IgG antibody test kit (brand B) presented a 75.00% (30/40) sensitivity and 100.00% (100/100) specificity for detection of cysticercosis. The sensitivity for detection of cysticercosis was significantly higher by the anti-cysticercus IgG antibody test kit (brand A) than by the anti-cysticercus IgG antibody test kit (brand B) (χ2 = 6.28, P < 0.05); however, no significant difference was seen in the specificity by two kits (χ2 = 2.01, P > 0.05). The four ELISA kits showed overall false positive rates of 37.88% (25/66), 22.73% (15/66), 62.12% (41/66) and 15.15% (10/66) for detection of paragonimiasis, echinococcosis and sparganosis (χ2 = 37.61, P < 0.05), and the anti-cysticercus IgG antibody test kit (brand A) presented the highest overall false positive rate for detection of paragonimiasis, echinococcosis and sparganosis (χ2 = 7.56, P' < 0.008), while a higher overall false positive rate was seen for detection of paragonimiasis, echinococcosis and sparganosis by the anti-cysticercus IgG antibody test kit (brand A) than by the anti-cysticercus IgG antibody test kit (brand B) (χ2 = 8.75, P' < 0.008). The four ELISA kits showed false positive rates of 40.00% (12/30), 16.67% (5/30), 76.67% (23/30) and 13.33% (4/30) for detection of paragonimiasis (χ2 = 32.88, P < 0.05) and 21.05% (4/19), 26.32% (5/19), 73.68% (14/19) and 15.79% (3/19) for detection of sparganosis (χ2 = 19.97, P < 0.05), and the highest false positive rates were found by the anti-cysticercus IgM antibody test kit (brand A) for detection of paragonimiasis and sparganosis (all P' < 0.008). However, the four ELISA kits showed comparable false positive rates of 52.94% (9/17), 29.41% (5/17), 23.53% (4/17) and 17.65% (3/17) for detection of echinococcosis (χ2 = 8.24, P > 0.05). In addition, the anti-cysticercus IgM anti-body test kit (brand A) showed false positive rates of 76.67% (23/30), 23.53% (4/17) and 73.68% (14/19) for detection of paragonimiasis, echinococcosis and sparganosis (χ2 = 14.537, P < 0.05), with the lowest false positive rate seen for detection of echinococcosis (χ2 = 14.537, P' < 0.014), while no significant differences were seen in the false positive rate for detection of paragonimiasis, echinococcosis and sparganosis by other three ELISA kits (all P > 0.05). CONCLUSIONS: The four anti-cysticercus IgG, IgG4 or IgM antibody test kits exhibit various efficiencies for serodiagnosis of cysticercosis. The anti-cysticercus IgG antibody test kit (brand A) has a high sensitivity for serodiagnosis of cysticercosis; however, it still needs to solve the problems of cross-reaction with other parasitic diseases and stability.


Asunto(s)
Cisticercosis , Cysticercus , Animales , Anticuerpos Antihelmínticos , Cisticercosis/diagnóstico , Ensayo de Inmunoadsorción Enzimática , Humanos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Pruebas Serológicas
17.
Sci Rep ; 12(1): 1643, 2022 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-35102224

RESUMEN

The aim of the study was to compare 3 blood sampling methods, including capillary blood sampling, for determining Tamoxifen (TAM), Z-endoxifen (END), and 4-hydroxytamoxifen (4HT) concentrations. High performance liquid chromatography-mass spectrometry was used to quantify concentrations of TAM, END, and 4HT in plasma, venous blood, and capillary blood samples of 16 participants on TAM therapy for breast cancer. The rhelise kit was used for capillary sampling. Calibration curves using 13C-labeled analogs of TAM, END, and 4HT as internal standards were used for quantifications. A capillary sampling kit was used successfully for all participants. Mean TAM concentrations did not differ significantly in the 3 types of samples. Mean END and 4HT concentrations did differ significantly between capillary and venous blood samples, possibly related to photodegradation in the internal standards prior to use or degradation products with chromatographic retention times similar to the metabolites. TAM, END, and 4HT concentrations were relatively stable when stored for 14 days at 8 °C and 20 °C. Therapeutic drug monitoring of TAM using an innovative kit and capillary blood sampling is feasible. Preliminary data from this study will aid in developing a multicenter, randomized clinical trial of personalized TAM dose monitoring and adjustments, with the goal of enhancing the quality-of-life and outcomes of patients with breast cancer.Clinical Trial Identification: EudraCT No 2017-000641-44.


Asunto(s)
Neoplasias de la Mama/sangre , Monitoreo de Drogas/instrumentación , Antagonistas de Estrógenos/sangre , Juego de Reactivos para Diagnóstico , Tamoxifeno/análogos & derivados , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/tratamiento farmacológico , Capilares , Cromatografía Líquida de Alta Presión , Antagonistas de Estrógenos/uso terapéutico , Estudios de Factibilidad , Femenino , Humanos , Espectrometría de Masas , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Suecia , Tamoxifeno/sangre , Tamoxifeno/uso terapéutico
18.
Front Immunol ; 13: 793882, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35154111

RESUMEN

In a world with an increasing population at risk of exposure to arthropod-borne flaviviruses, access to timely and accurate diagnostic tests would impact profoundly on the management of cases. Twenty peptides previously identified using a flavivirus proteome-wide microarray were evaluated to determine their discriminatory potential to detect dengue virus (DENV) infection. This included nine peptides recognized by IgM antibodies (PM peptides) and 11 peptides recognized by IgG antibodies (PG peptides). A bead-based multiplex peptide immunoassay (MPIA) using the Luminex technology was set-up to determine Ab binding levels to each of these peptides in a panel of 323 carefully selected human serum samples. Sera are derived from individuals either infected with different viruses, namely, the four DENV serotypes, Zika virus (ZIKV), yellow fever virus (YFV), chikungunya virus (CHIKV), West Nile virus (WNV) and Human immunodeficiency virus (HIV), or receiving vaccination against YFV, tick-borne encephalitis (TBEV), and Japanese encephalitis virus (JEV). Additionally, a set of healthy controls were included. We targeted a minimum specificity of 80% for all the analysis. The PG-9 peptide had the best sensitivity (73%) when testing DENV sera from acute patients (A-DENV; <8 days since symptom onset). With sera from convalescent DENV patients (C-DENV; >10 days since symptom onset) the FPG-1 peptide was the best seromarker with a sensitivity of 86%. When combining all A-DENV and C-DENV samples, peptides PM-22 and FPG-1 had the best-diagnostic performance with a sensitivity of 60 and 61.1%, and areas under the curve (AUC) of 0.7865 and 0.8131, respectively. A Random forest (RF) algorithm was used to select the best combination of peptides to classify DENV infection at a targeted specificity >80%. The best RF model for PM peptides that included A-DENV and C-DENV samples, reached a sensitivity of 72.3%, while for PG peptides, the best RF models for A-DENV only, C-DENV only and A-DENV + C-DENV reached a sensitivity of 88.9%, 89.1%, and 88.3%, respectively. In conclusion, the combination of multiple peptides constitutes a founding set of seromarkers for the discrimination of DENV infected individuals from other flavivirus infections.


Asunto(s)
Biomarcadores , Virus del Dengue/fisiología , Dengue/diagnóstico , Dengue/microbiología , Péptidos , Proteínas Virales , Adolescente , Adulto , Anciano , Anticuerpos Antivirales , Biomarcadores/sangre , Niño , Preescolar , Dengue/sangre , Dengue/epidemiología , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Péptidos/sangre , Perú/epidemiología , Pronóstico , Proteoma , Proteómica/métodos , Curva ROC , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Proteínas Virales/sangre , Adulto Joven
19.
JAMA Otolaryngol Head Neck Surg ; 148(3): 252-258, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35024772

RESUMEN

IMPORTANCE: Current tools for diagnosis of olfactory dysfunction (OD) are costly, time-consuming, and often require clinician administration. OBJECTIVE: To develop and validate a simple screening assessment for OD using common household items. DESIGN, SETTING, AND PARTICIPANTS: This fully virtual diagnostic study included adults with self-reported OD from any cause throughout the US. Data were collected from December 2020 to April 2021 and analyzed from May 2021 to July 2021. MAIN OUTCOMES AND MEASURES: Participants with self-reported olfactory dysfunction took a survey assessing smell perception of 45 household items and completed the Clinical Global Impression-Severity (CGI-S) smell questionnaire, the University of Pennsylvania Smell Identification Test (UPSIT), and the 36-item Short Form Survey (SF-36). Psychometric and clinimetric analyses were used to consolidate 45 household items into 2 short Novel Anosmia Screening at Leisure (NASAL) assessments, NASAL-7 (range, 0-14; lower score indicating greater anosmia) and NASAL-3 (range, 0-6; lower score indicating greater anosmia). RESULTS: A total of 115 participants were included in the study, with a median (range) age of 42 (19-70) years, 92 (80%) women, and 97 (84%) White individuals. There was a moderate correlation between the UPSIT and NASAL-7 scores and NASAL-3 scores (NASAL-7: ρ = 0.484; NASAL-3: ρ = 0.404). Both NASAL-7 and NASAL-3 had moderate accuracy in identifying participants with anosmia as defined by UPSIT (NASAL-7 area under the receiver operating curve [AUC], 0.706; 95% CI, 0.551-0.862; NASAL-3 AUC, 0.658; 95% CI, 0.503-0.814). Scoring 7 or less on the NASAL-7 had 70% (95% CI, 48%-86%) sensitivity and 53% (95% CI, 43%-63%) specificity in discriminating participants with anosmia from participants without. Scoring 2 or less on the NASAL-3 had 57% (95% CI, 36%-76%) sensitivity and 78% (95% CI, 69%-85%) specificity in discriminating participants with anosmia from participants without. There was moderate agreement between UPSIT-defined OD categories and those defined by NASAL-7 (weighted κ = 0.496; 95% CI, 0.343-0.649) and those defined by NASAL-3 (weighted κ = 0.365; 95% CI, 0.187-0.543). The agreement with self-reported severity of olfactory dysfunction as measured by CGI-S and the NASAL-7 and NASAL-3 was moderate, with a weighted κ of 0.590 (95% CI, 0.474-0.707) for the NASAL-7 and 0.597 (95% CI, 0.481-0.712) for the NASAL-3. CONCLUSION AND RELEVANCE: The findings of this diagnostic study suggest that NASAL-7 and NASAL-3, inexpensive and brief patient-reported assessments, can be used to identify individuals with OD. As the burden of COVID-19-associated OD increases, these assessments may prove beneficial as screening and diagnostic tools. Future work will explore whether the NASAL assessments are sensitive to change and how much of a change is clinically important.


Asunto(s)
COVID-19/complicaciones , Trastornos del Olfato/diagnóstico , Trastornos del Olfato/virología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Juego de Reactivos para Diagnóstico , SARS-CoV-2 , Encuestas y Cuestionarios , Adulto Joven
20.
Int Urol Nephrol ; 54(3): 493-498, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35080680

RESUMEN

The COVID-19 pandemic and subsequent lockdown had a substantial impact on normal research operations. Researchers needed to adapt their methods to engage at-home participants. One method is crowdsourcing, in which researchers use social media to recruit participants, gather data, and collect samples. We utilized this method to develop a diagnostic test for Interstitial Cystitis/Bladder Pain Syndrome (IC/BPS). Participants were recruited via posts on popular social-media platforms, and enrolled via a website. Participants received and returned a mail kit containing bladder symptom surveys and a urine sample cup containing room-temperature preservative. Using this method, we collected 1254 IC/BPS and control samples in 3 months from all 50 United States. Our data demonstrate that crowdsourcing is a viable alternative to traditional research, with the ability to reach a broad patient population rapidly. Crowdsourcing is a powerful tool for at-home participation in research, particularly during the lockdown caused by the COVID-19 pandemic.


Asunto(s)
Investigación Biomédica , COVID-19 , Colaboración de las Masas/métodos , Cistitis Intersticial , Participación del Paciente , Urinálisis , Investigación Biomédica/organización & administración , Investigación Biomédica/tendencias , COVID-19/epidemiología , COVID-19/prevención & control , Control de Enfermedades Transmisibles , Cistitis Intersticial/diagnóstico , Cistitis Intersticial/epidemiología , Técnicas y Procedimientos Diagnósticos/tendencias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Participación del Paciente/métodos , Participación del Paciente/estadística & datos numéricos , Selección de Paciente , Juego de Reactivos para Diagnóstico/provisión & distribución , Proyectos de Investigación , SARS-CoV-2 , Medios de Comunicación Sociales , Manejo de Especímenes/métodos , Estados Unidos/epidemiología , Urinálisis/instrumentación , Urinálisis/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA