Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.237
Filtrar
1.
Klin Onkol ; 38(2): 102-109, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38697818

RESUMEN

BACKGROUND: Endometrial carcinoma (EC) is the most common cancer of the female reproductive tract in developed countries. The prognosis and 5-year survival rates are closely tied to the stage diagnosis. Current routine diagnostic methods of EC are either lacking specificity or are uncomfortable, invasive and painful for the patient. As of now, the gold diagnostic standard is endometrial biopsy. Early and non-invasive diagnosis of EC requires the identification of new biomarkers of disease and a screening test applicable to routine laboratory diagnostics. The application of untargeted metabolomics combined with artificial intelligence and biostatistics tools has the potential to qualitatively and quantitatively represent the metabolome, but its introduction into routine diagnostics is currently unrealistic due to the financial, time and interpretation challenges. Fluorescence spectral analysis of body fluids utilizes autofluorescence of certain metabolites to define the composition of the metabolome under physiological conditions. PURPOSE: This review highlights the potential of fluorescence spectroscopy in the early detection of EC. Data obtained by three-dimensional fluorescence spectroscopy define the quantitative and qualitative composition of the complex fluorescent metabolome and are useful for identifying biochemical metabolic changes associated with endometrial carcinogenesis. Autofluorescence of biological fluids has the prospect of providing new molecular markers of EC. By integrating machine learning and artificial intelligence algorithms in the data analysis of the fluorescent metabolome, this technique has great potential to be implemented in routine laboratory diagnostics.


Asunto(s)
Líquidos Corporales , Neoplasias Endometriales , Humanos , Neoplasias Endometriales/diagnóstico , Femenino , Líquidos Corporales/química , Biomarcadores de Tumor/análisis , Espectrometría de Fluorescencia/métodos , Detección Precoz del Cáncer/métodos , Metabolómica/métodos , Imagen Óptica , Inteligencia Artificial
2.
Clin Chim Acta ; 558: 119678, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38641194

RESUMEN

Recurrent implantation failure (RIF) is a significant obstacle in assisted reproductive procedures, primarily because of compromised receptivity. As such, there is a need for a dependable and accurate clinical test to evaluate endometrial receptiveness, particularly during embryo transfer. MicroRNAs (miRNAs) have diverse functions in the processes of implantation and pregnancy. Dysregulation of miRNAs results in reproductive diseases such as recurrent implantation failure (RIF). The endometrium secretes several microRNAs (miRNAs) during the implantation period, which could potentially indicate whether the endometrium is suitable for in vitro fertilization (IVF). The goal of this review is to examine endometrial miRNAs as noninvasive biomarkers that successfully predict endometrium receptivity in RIF.


Asunto(s)
Implantación del Embrión , MicroARNs , Humanos , Femenino , MicroARNs/genética , Implantación del Embrión/genética , Útero/metabolismo , Líquidos Corporales/metabolismo , Líquidos Corporales/química , Endometrio/metabolismo , Embarazo , Fertilización In Vitro , Biomarcadores/metabolismo
3.
Int J Mol Sci ; 25(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38542494

RESUMEN

Body fluid identification plays a crucial role in criminal investigations. Because of their presence in many cases, blood and semen are the most relevant body fluids in forensic sciences. Based on antigen-antibody reactions binding unique proteins for each body fluid, serological assays represent one of the most rapid and highly specific tests for blood and semen. Currently, few studies have assessed the factors affecting body fluid identification by applying these assays. This work aimed to study the effect of different fabrics from clothes and time since deposition on identification through immunochromatographic tests for blood and semen, DNA isolation, and STR profiling from these samples. Body fluids were deposited on black- and white-dyed denim and cotton fabrics, and on leather. Afterward, blood and semen were sampled at 1 day, 30 days, and 90 days after deposition and identified by using the SERATEC® HemDirect Hemoglobin Test and the PSA Semiquant and SERATEC® BLOOD CS and SEMEN CS tests, respectively. Laboratory and crime scene tests presented similar performances for the detection of blood and semen stains on every tested fabric. No differences were found on band intensities between timepoints for all fabrics. It was possible to recover and identify blood and semen samples up to three months after deposition and to obtain full STR profiles from all the tested fabrics. Both body fluid STR profiles showed differences in their quality between 1 and 90 days after deposition for all fabrics except for black cotton for semen samples. Future research will expand the results, assessing body fluid identification on other substrates and under different environmental conditions.


Asunto(s)
Líquidos Corporales , Semillas , Humanos , Semillas/química , Líquidos Corporales/química , Secreciones Corporales/química , Análisis de Semen , ADN/análisis , Saliva/química , Dermatoglifia del ADN
4.
Analyst ; 149(7): 2170-2179, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38445310

RESUMEN

Due to the eutrophication of water bodies around the world, there is a drastic increase in harmful cyanobacterial blooms leading to contamination of water bodies with cyanotoxins. Chronic exposure to cyanotoxins such as microcystin leads to oxidative stress, inflammation, and liver damage, and potentially to liver cancer. We developed a novel and easy-to-use electrochemical impedance spectroscopy-based immunosensor by fabricating stencil-printed conductive carbon-based interdigitated microelectrodes and immobilising them with cysteamine-capped gold nanoparticles embedded in polyaniline. It has been also coupled with a custom handheld device enabling regular on-site assessment, especially in resource-constrained situations encountered in developing countries. The sensor is able to detect microcystin-LR up to 0.1 µg L-1, having a linear response between 0.1 and 100 µg L-1 in lake and river water and in serum and urine samples. In addition to being inexpensive, easy to fabricate, and sensitive, it also has very good selectivity.


Asunto(s)
Técnicas Biosensibles , Líquidos Corporales , Toxinas Marinas , Nanopartículas del Metal , Microcistinas , Oro/química , Inmunoensayo , Lagos , Agua/química , Líquidos Corporales/química
5.
J Breath Res ; 18(2)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38290132

RESUMEN

Exhaustive exercise can induce unique physiological responses in the lungs and other parts of the human body. The volatile organic compounds (VOCs) in exhaled breath are ideal for studying the effects of exhaustive exercise on the lungs due to the proximity of the breath matrix to the respiratory tract. As breath VOCs can originate from the bloodstream, changes in abundance should also indicate broader physiological effects of exhaustive exercise on the body. Currently, there is limited published data on the effects of exhaustive exercise on breath VOCs. Breath has great potential for biomarker analysis as it can be collected non-invasively, and capture real-time metabolic changes to better understand the effects of exhaustive exercise. In this study, we collected breath samples from a small group of elite runners participating in the 2019 Ultra-Trail du Mont Blanc ultra-marathon. The final analysis included matched paired samples collected before and after the race from 24 subjects. All 48 samples were analyzed using the Breath Biopsy Platform with GC-Orbitrap™ via thermal desorption gas chromatography-mass spectrometry. The Wilcoxon signed-rank test was used to determine whether VOC abundances differed between pre- and post-race breath samples (adjustedP-value < .05). We identified a total of 793 VOCs in the breath samples of elite runners. Of these, 63 showed significant differences between pre- and post-race samples after correction for multiple testing (12 decreased, 51 increased). The specific VOCs identified suggest the involvement of fatty acid oxidation, inflammation, and possible altered gut microbiome activity in response to exhaustive exercise. This study demonstrates significant changes in VOC abundance resulting from exhaustive exercise. Further investigation of VOC changes along with other physiological measurements can help improve our understanding of the effect of exhaustive exercise on the body and subsequent differences in VOCs in exhaled breath.


Asunto(s)
Líquidos Corporales , Compuestos Orgánicos Volátiles , Humanos , Pruebas Respiratorias/métodos , Compuestos Orgánicos Volátiles/análisis , Espiración , Cromatografía de Gases y Espectrometría de Masas/métodos , Líquidos Corporales/química
6.
Anal Chim Acta ; 1289: 342204, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38245205

RESUMEN

BACKGROUND: Gas chromatography-ion mobility spectrometry (GC-IMS) is a powerful analytical technique which has gained widespread use in a variety of fields. Detecting peaks in GC-IMS data is essential for chemical identification. Topological data analysis (TDA) has the ability to record alterations in topology throughout the entire spectrum of GC-IMS data and retain this data in diagrams known as persistence diagrams. To put it differently, TDA naturally identifies characteristics such as mountains, volcanoes, and their higher-dimensional equivalents within the original data and measures their significance. RESULTS: In the present contribution, a novel approach based on persistent homology (a flagship technique of TDA) is suggested for automatic 2D peak detection in GC-IMS. For this purpose, two different GC-IMS data examples (urine and olive oil) are used to show the performance of the proposed method. The outputs of the algorithm are GC-IMS chromatogram with detected peaks, persistence plot showing the importance (intensity) of the detected peaks and a table with retention times (RT), drift times (DT), and persistence scores of detected peaks. The RT and DT can be used for identification of the peaks and persistence scores for quantitation. Additionally, watershed segmentation is applied to the GC-IMS images to index individual peaks and segment overlapping compounds allowing for a more accurate identification and quantification of individual peaks. SIGNIFICANCE: Inspection of the results for GC-IMS datasets showed the accurate and reliable performance of the proposed strategy based on persistent homology for automatic 2D GC-IMS peak detection for qualitative and quantitative analysis. In addition, this approach can be easily extended to other types of hyphenated chromatographic and/or spectroscopic data.


Asunto(s)
Líquidos Corporales , Compuestos Orgánicos Volátiles , Cromatografía de Gases y Espectrometría de Masas/métodos , Espectrometría de Movilidad Iónica/métodos , Aceite de Oliva/análisis , Líquidos Corporales/química , Algoritmos , Compuestos Orgánicos Volátiles/análisis
7.
Forensic Sci Int ; 354: 111914, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38154427

RESUMEN

A comprehensive investigation into the impact of the physical and chemical variables of a substrate on the deposition was conducted to aid in the estimation of the subsequent transfer probabilities of blood and semen. The study focussed on surface roughness, topography, surface free energy (SFE), wettability, and the capacity for protein adsorption. Conjointly, evaluations of the physical and chemical characteristics of blood and seminal deposits were conducted, to assess the fluid dynamics of these non-Newtonian fluids and their adhesion potential to aluminium and polypropylene. A linear range of surface roughness parameters (0.5 - 3.5 µm) were assessed for their impact on the deposit deposition spread and adhesion height, to gather insight into the change in fluid dynamics of non-Newtonian fluids. Blood has shown to produce a uniform adhesion coverage on aluminium across all roughness categories while blood deposited on polypropylene exhibited a strong hydrophobic response from a surface roughness of 2.0 µm and beyond. Interestingly, the deposition height of blood resulted in near identical values, whether deposited onto the hydrophobic polypropylene or the hydrophilic aluminium substrate, illustrating the potential influence of a heightened fibrinogen adsorption effect. Semen deposited on aluminium resulted in concentrated localised deposition regions after reaching a surface roughness of 2.0 µm, highlighting the development of crystal formations afforded by the sodium ion concentration in the seminal fluid. The semen deposited on polypropylene conformed to the substrate contours producing a deposition film that was smoother than the substrate itself, underlining the effects of thixotropic fluid dynamics. Variables identified here establish the complexity observed for non-Newtonian fluids, and the effect protein adsorption may have on the deposition behaviour of blood and seminal deposits and inform questions in relation to the adhesion strength of said deposits and their ability to dislodge (becoming detached upon the application of an external force) from the substrate surface during a potential transfer event.


Asunto(s)
Líquidos Corporales , Polipropilenos , Propiedades de Superficie , Polipropilenos/análisis , Aluminio/análisis , Humectabilidad , Líquidos Corporales/química
8.
ACS Sens ; 8(9): 3307-3319, 2023 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-37540230

RESUMEN

With the expansion of the Internet-of-Things (IoT), the use of gas sensors in the field of wearable technology, smart devices, and smart homes has increased manifold. These gas sensors have two key applications─one is the detection of gases present in the environment and the other is the detection of Volatile Organic Compounds (VOCs) that are found in the breath. In this review, we focus systematically on the advancements in the field of various spectroscopic methods such as mass spectrometry-based analysis and point-of-care approach to detect VOCs and gases for environmental monitoring and disease diagnosis. Additionally, we highlight the development of smart sensors that work on the principle of electrochemical detection and provide examples of the same through an extensive literature review. At the end of this review, we highlight various challenges and future perspectives.


Asunto(s)
Líquidos Corporales , Compuestos Orgánicos Volátiles , Dispositivos Electrónicos Vestibles , Gases/análisis , Líquidos Corporales/química , Compuestos Orgánicos Volátiles/análisis , Espectrometría de Masas
9.
J Forensic Leg Med ; 97: 102551, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37339573

RESUMEN

PURPOSE: In cases of drowning, the presence of sphenoid sinus fluid is a non-specific autopsy finding. However, studies have reported that fluid accumulation in the paranasal sinuses is more commonly observed in drowning victims. Furthermore, some laboratory tests, such as diatom and electrolyte analysis, can serve as supplementary diagnostic tools for diagnosing drowning. Therefore, accurate sphenoid sinus fluid sampling is an important aspect of an autopsy in suspected drowning cases. The aim of this study was to identify the significance of evaluating sphenoid sinus fluid by PMCT images in cases of drowning. METHODS: We retrospectively reviewed 54 drowning victims who underwent PMCT and forensic autopsy. Fluid volume in the sphenoid sinus was measured using a graduated syringe during autopsy and a three-dimensional (3D) workstation based on PMCT images was used for the purpose of comparison. The Mann-Whitney U test and Spearman's rank correlation coefficient was used to evaluate statistically significant differences and correlations. Additionally, a Bland-Altman plot was employed to assess the agreement between PMCT and autopsy. RESULTS: The median volume was 1.65 (range 0.00-12.4) ml and 1.55 (range 0.00-7.00) ml in the PMCT and autopsy, respectively, showing a statistically insignificant difference (p = 0.294) and a significant correlation (Rs = 0.896). In 35 cases, the PMCT overestimated the fluid volume more than the autopsy, whereas in 14 cases, the PMCT underestimated the fluid volume. No fluid was identified in seven cases during the autopsy, whereas in five patients, no fluid was found in both PMCT and autopsy. By analyzing the Bland-Altman plot, a bias of 0.73 ± 1.4 ml and limits of agreement ranging from -2.04 to 3.51 ml were observed for sphenoid sinus fluid volume measurements. CONCLUSIONS: Based on the limitations of traditional fluid volume measurement in the sphenoid sinus during autopsy, we propose the utilization of PMCT volumetric analysis prior to autopsy as a means to enhance the detection of sphenoid sinus fluid in cases of drowning.


Asunto(s)
Líquidos Corporales , Ahogamiento , Cambios Post Mortem , Seno Esfenoidal , Seno Esfenoidal/diagnóstico por imagen , Seno Esfenoidal/patología , Ahogamiento/diagnóstico por imagen , Ahogamiento/patología , Tomografía Computarizada por Rayos X , Humanos , Líquidos Corporales/química , Líquidos Corporales/diagnóstico por imagen , Persona de Mediana Edad
11.
ACS Biomater Sci Eng ; 9(5): 2376-2391, 2023 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-37071118

RESUMEN

Currently, permanent vascular stents are fabricated using titanium and stainless steel implants that are nondegradable and offer high stability, but they have certain disadvantages. For example, the prolonged exposition of aggressive ions in the physiological media and the existence of defects in the oxide film create conditions for corrosion to occur, thus triggering unwanted biological events and compromising the mechanical integrity of the implants. Moreover, when the implant does not need to be permanent, there is the need to submit the patient for a second surgery for implant removal. As a solution for nonpermanent implants, biodegradable magnesium alloys have been deemed a promising substitute, for example, for cardiovascular-related applications and the construction of orthopedic devices. A biodegradable magnesium alloy (Mg-2.5Zn) reinforced by zinc and eggshell was employed in this study as an environment-conscious magnesium (eco) composite (Mg-2.5Zn-xES). Disintegrated melt deposition (DMD) was used to fabricate the composite. Experimental studies were conducted to investigate the biodegradation performance of Mg-Zn alloys containing 3 and 7 wt % eggshell (ES) in simulated body fluid (SBF) at 37 °C. Different corrosion techniques were used to study the corrosion behavior of the Mg-2.5Zn-xES composites, including weight loss measurements, hydrogen evolution, potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and scanning vibrating electrode technique (SVET). Scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) were employed to scrutinize the corroded surfaces' morphology and composition. The outcomes indicated that Mg-2.5Zn-3ES possesses the lowest degradation activity.


Asunto(s)
Aleaciones , Líquidos Corporales , Animales , Humanos , Aleaciones/química , Magnesio/análisis , Magnesio/química , Cáscara de Huevo , Prótesis e Implantes , Líquidos Corporales/química
12.
ACS Sens ; 8(4): 1450-1461, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36926819

RESUMEN

Liquid biopsy is seen as a prospective tool for cancer screening and tracking. However, the difficulty lies in effectively sieving, isolating, and overseeing cancer biomarkers from the backdrop of multiple disrupting cells and substances. The current study reports on the ability to perform liquid biopsy without the need to physically filter and/or isolate the cancer cells per se. This has been achieved through the detection and classification of volatile organic compounds (VOCs) emitted from the cancer cells found in the headspace of blood or urine samples or a combined data set of both. Spectrometric analysis shows that blood and urine contain complementary or overlapping VOC information on kidney cancer, gastric cancer, lung cancer, and fibrogastroscopy subjects. Based on this information, a nanomaterial-based chemical sensor array in conjugation with machine learning as well as data fusion of the signals achieved was carried out on various body fluids to assess the VOC profiles of cancer. The detection of VOC patterns by either Gas Chromatography-Mass Spectrometry (GC-MS) analysis or our sensor array achieved >90% accuracy, >80% sensitivity, and >80% specificity in different binary classification tasks. The hybrid approach, namely, analyzing the VOC datasets of blood and urine together, contributes an additional discrimination ability to the improvement (>3%) of the model's accuracy. The contribution of the hybrid approach for an additional discrimination ability to the improvement of the model's accuracy is examined and reported.


Asunto(s)
Líquidos Corporales , Neoplasias Pulmonares , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Biomarcadores de Tumor/análisis , Neoplasias Pulmonares/diagnóstico , Líquidos Corporales/química , Biopsia Líquida
13.
Clin Sci (Lond) ; 137(3): 239-250, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36648486

RESUMEN

Increasing evidence suggests excess skin Na+ accumulation in hypertension; however, the role of skin-specific mechanisms of local Na+/water regulation remains unclear. We investigated the association between measures of sweat and trans-epidermal water loss (TEWL) with Na+ content in the skin ([Na+]skin) and clinical characteristics in consecutive hypertensive patients. We obtained an iontophoretic pilocarpine-induced sweat sample, a skin punch biopsy for chemical analysis, and measures of TEWL from the upper limbs. Serum vascular endothelial growth factor-c (VEGF-c) and a reflectance measure of haemoglobin skin content served as surrogates of skin microvasculature. In our cohort (n = 90; age 21-86 years; females = 49%), sweat composition was independent of sex and BMI. Sweat Na+ concentration ([Na+]sweat) inversely correlated with [K+]sweat and was higher in patients on ACEIs/ARBs (P < 0.05). A positive association was found between [Na+]sweat and [Na+]skin, independent of sex, BMI, estimated Na+ intake and use of ACEi/ARBs (Padjusted = 0.025); both closely correlated with age (P < 0.01). Office DBP, but not SBP, inversely correlated with [Na+]sweat independent of other confounders (Padjusted = 0.03). Total sweat volume and Na+ loss were lower in patients with uncontrolled office BP (Padjusted < 0.005 for both); sweat volume also positively correlated with serum VEGF-c and TEWL. Lower TEWL was paralleled by lower skin haemoglobin content, which increased less after vasodilatory pilocarpine stimulation when BMI was higher (P = 0.010). In conclusion, measures of Na+ and water handling/regulation in the skin were associated with relevant clinical characteristics, systemic Na+ status and blood pressure values, suggesting a potential role of the skin in body-fluid homeostasis and therapeutic targeting of hypertension.


Asunto(s)
Líquidos Corporales , Hipertensión , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Factor C de Crecimiento Endotelial Vascular , Antagonistas de Receptores de Angiotensina , Pilocarpina , Inhibidores de la Enzima Convertidora de Angiotensina , Sodio , Líquidos Corporales/química , Agua
14.
PeerJ ; 11: e14737, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36718454

RESUMEN

Objective: This study aimed to address on the most important concern of surgeons-whether to completely resect tumor. Urine can indicate early changes associated with physiological or pathophysiological processes. Based on these ideas, we conducted experiments to explore changes in the urine proteome between tumor-bearing mice and tumor-resected mice. Method: The tumor-bearing mouse model was established with MC38 mouse colon cancer cells, and the mice were divided into the control group, tumor-resected group, and tumor-bearing group. Urine was collected 7 and 30 days after tumor resection. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was used to identify the urine proteome, which was analyzed for differentially expressed proteins and functional annotation. Results: (1) Seven days after tumor resection, 20 differentially expressed proteins distinguished the tumor-resected group and the tumor-bearing group. The identified biological processes included circadian rhythm, Notch signaling pathway, leukocyte cell-cell adhesion, and heterophilic cell-cell adhesion via plasma membrane cell adhesion molecules. (2) Thirty days after tumor resection, 33 differentially expressed proteins distinguished the tumor-resected group and the tumor-bearing group. The identified biological processes included cell adhesion; complement activation, the alternative pathway; the immune system process; and angiogenesis. (3) The difference in the urine proteome between the tumor-resected group and the healthy control group was smaller 30 days after tumor resection. Conclusion: Changes in the urinary proteome can reflect the complete resection of MC38 tumors.


Asunto(s)
Líquidos Corporales , Neoplasias , Ratones , Animales , Cromatografía Liquida/métodos , Proteoma/análisis , Espectrometría de Masas en Tándem , Líquidos Corporales/química
15.
Am J Forensic Med Pathol ; 44(2): 97-99, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36716410

RESUMEN

ABSTRACT: Volatile chemicals can be relevant in the determination of the cause and manner of death by forensic pathologists. Isopropanol is a secondary alcohol that is occasionally seen on postmortem toxicology testing. A series of 11 forensic autopsy cases was previously reported in which the presence of isopropanol in the vitreous humor was suspected to be due to postmortem contamination from the body preparation process for tissue procurement.In collaboration with a tissue procurement agency, donor vitreous humor was collected from one eye before body preparation for procurement and from the other eye postpreparation. The specimens underwent testing for volatile substances by headspace gas chromatography.Of the 50 cases, 8 (16%) showed statistically significant changes in the prepreparation and postpreparation isopropanol concentrations. Postpreparation isopropanol concentrations ranged from 5 to 104 mg/dL (median, 18 mg/dL). Seven of the 8 cases had undetectable prepreparation isopropanol, whereas the remaining case had a detectable prepreparation isopropanol.In conclusion, surface contamination of the decedent's body with chemicals used in body preparation can lead to the passive absorption into the body, resulting in the presence of isopropanol in postmortem toxicology samples. Forensic pathologists need to be aware of this when interpreting postmortem samples after tissue procurement.


Asunto(s)
Líquidos Corporales , Obtención de Tejidos y Órganos , Humanos , Autopsia , 2-Propanol/análisis , Etanol/análisis , Líquidos Corporales/química , Cambios Post Mortem
16.
J Biomed Mater Res B Appl Biomater ; 111(5): 987-995, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36444900

RESUMEN

Integration of native bone into orthopedic devices is a key factor in long-term implant success. The material-tissue interface is generally accepted to consist of a hydroxyapatite layer so bioactive materials that can spontaneously generate this hydroxyapatite layer after implantation may improve patient outcomes. Per the ISO 22317:2014 standard, "Implants for surgery - In vitro evaluation for apatite-forming ability of implant materials," bioactivity performance statements can be assessed by soaking the material in simulated body fluid (SBF) and evaluating the surface for the formation of a hydroxyapatite layer; however, variations in test methods may alter hydroxyapatite formation and result in false-positive assessments. The goal of this study was to identify the effect of SBF formulation on bioactivity assessment. Bioglass® (45S5 and S53P4) and non-bioactive Ti-6Al-4V were exposed to SBF formulations varying in calcium ion and phosphate concentrations as well as supporting ion concentrations. Scanning electron microscopy and X-ray powder diffraction evaluation of the resulting hydroxyapatite layers revealed that SBF enriched with double or quadruple the calcium and phosphate ion concentrations increased hydroxyapatite crystal size and quantity compared to the standard formulation and can induce hydroxyapatite crystallization on surfaces traditionally considered non-bioactive. Altering concentrations of other ions, for example, bicarbonate, changed hydroxyapatite induction time, quantity, and morphology. For studies evaluating the apatite-forming ability of a material to support bioactivity performance statements, test method parameters must be adequately described and controlled. It is unclear if apatite formation after exposure to any of the SBF formulations is representative of an in vivo biological response. The ISO 23317 standard test method should be further developed to provide additional guidance on apatite characterization and interpretation of the results.


Asunto(s)
Apatitas , Líquidos Corporales , Humanos , Apatitas/química , Calcio/química , Propiedades de Superficie , Durapatita/química , Líquidos Corporales/química , Microscopía Electrónica de Rastreo , Difracción de Rayos X
17.
Crit Rev Anal Chem ; 53(7): 1561-1590, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35157535

RESUMEN

This review surveys Infrared, Raman/SERS and Brillouin spectroscopies for medical diagnostics and detection of biomarkers in biofluids, that include urine, blood, saliva and other biofluids. These optical sensing techniques are non-contact, noninvasive and relatively rapid, accurate, label-free and affordable. However, those techniques still have to overcome some challenges to be widely adopted in routine clinical diagnostics. This review summarizes and provides insights on recent advancements in research within the field of vibrational spectroscopy for medical diagnostics and its use in detection of many health conditions such as kidney injury, cancers, cardiovascular and infectious diseases. The six comprehensive tables in the review and four tables in supplementary information summarize a few dozen experimental papers in terms of such analytical parameters as limit of detection, range, diagnostic sensitivity and specificity, and other figures of merits. Critical comparison between SERS and FTIR methods of analysis reveals that on average the reported sensitivity for biomarkers in biofluids for SERS vs FTIR is about 103 to 105 times higher, since LOD SERS are lower than LOD FTIR by about this factor. High sensitivity gives SERS an edge in detection of many biomarkers present in biofluids at low concentration (nM and sub nM), which can be particularly advantageous for example in early diagnostics of cancer or viral infections.HighlightsRaman, Infrared spectroscopies use low volume of biofluidic samples, little sample preparation, fast time of analysis and relatively inexpensive instrumentation.Applications of SERS may be a bit more complicated than applications of FTIR (e.g., limited shelf life for nanoparticles and substrates, etc.), but this can be generously compensated by much higher (by several order of magnitude) sensitivity in comparison to FTIR.High sensitivity makes SERS a noninvasive analytical method of choice for detection, quantification and diagnostics of many health conditions, metabolites, and drugs, particularly in diagnostics of cancer, including diagnostics of its early stages.FTIR, particularly ATR-FTIR can be a method of choice for efficient sensing of many biomarkers, present in urine, blood and other biofluids at sufficiently high concentrations (mM and even a few µM)Brillouin scattering spectroscopy detecting visco-elastic properties of probed liquid medium, may also find application in clinical analysis of some biofluids, such as cerebrospinal fluid and urine.


Asunto(s)
Líquidos Corporales , Nanopartículas del Metal , Neoplasias , Humanos , Espectrometría Raman/métodos , Líquidos Corporales/química , Neoplasias/diagnóstico , Nanopartículas del Metal/química , Biomarcadores/análisis
18.
Genes (Basel) ; 15(1)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38275599

RESUMEN

Due to the scarcity of literature data on the DNA content of different human tissues, this study aimed to isolate DNA from different tissues and fluids of the human body together with the determination of its content in the samples studied. Material was collected and tests were performed between 1990 and 2010, during autopsies performed for prosecutor's offices in the Department of Forensic Medicine. Goiter and thyroid cancer tissues were obtained from the Department of General Surgery, Gastroenterology and Endocrinology of Wroclaw Medical University. Isolated samples were measured spectrophotometrically, yielding an R 260/280 nm between 1.5 and 1.6. In some cases (when a sufficiently pure preparation could not be obtained), isolation was continued using the silica-based commercial QIAquick PCR Purification Kit (Qiagen). If the sampling tissues showed signs of decomposition such as bad odour or colour, the results were calibrated by Real-Time PCR, using the Quantifiler DNA assay (Thermo Fisher Scientific, Applied Biosystems). The results have shown that the maximum amount of genetic material was obtained from hair roots, adrenal glands, gonads and lymph nodes. The lowest DNA content per gram or milliliter of tissue or body fluid was found in adipose tissue, blood, saliva, bile, sweat, tears and the vitreous body of the eye. The presented findings indicate the best sources of high-quality DNA from the human body: gonads, kidneys, muscle (including heart), blood and bones (after decalcification).


Asunto(s)
Líquidos Corporales , Cuerpo Humano , Humanos , Líquidos Corporales/química , ADN/genética , ADN/análisis , Saliva/química , Reacción en Cadena en Tiempo Real de la Polimerasa
19.
Environ Toxicol Pharmacol ; 95: 103978, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36155229

RESUMEN

Exposure to metals and trace elements (TE) is universal and can cause toxicity in case of excessive exposure. We evaluated the concentrations and tissue distribution of 39 TE using high-resolution ICP-MS after total mineralization by microwave in twenty autopsied French subjects. We found a globally homogeneous distribution of TE in the body, with some accumulations in agents, involved in respiratory pathologies and classified as carcinogens, in the lungs. The liver, an organ of metabolism, appeared to concentrate Co, Fe, La, Mn, Mo, Pb and Zn. Fe seemed to accumulate in the spleen, the organ of hematopoiesis. The kidney showed high concentrations of some TE, which can cause nephrotoxicity. The use of microwave mineralization and high-resolution ICP-MS allowed accurate quantification and a very high sensitivity, without spectral interferences. The results obtained in this study could be used to support the interpretation of post-mortem metal concentrations in tissues.


Asunto(s)
Líquidos Corporales , Oligoelementos , Líquidos Corporales/química , Líquidos Corporales/metabolismo , Carcinógenos , Cabello/química , Humanos , Plomo , Oligoelementos/análisis
20.
Forensic Sci Med Pathol ; 18(4): 393-402, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35699867

RESUMEN

Synthetic cannabinoids (SCs) remain one of the largest groups of new psychoactive substances. Recently, new synthetic cannabinoids 5F-MDMB-PICA and 4F-MDMB-BINACA are increasing in popularity. A 33-year-old man lost consciousness after smoking an unknown substance. A glass pipe and two lumps of substance that turned out to contain 5F-MDMB-PICA and 4F-MDMB-BINACA were found at the scene. Blood, urine and cerebrospinal fluid were collected during the examination of the body. The synthetic cannabinoids were isolated from autopsy materials by precipitation with acetonitrile and extraction with ethyl acetate. The screening and quantitative analyses were performed by liquid chromatography with tandem mass spectrometry (LC-MS/MS). The liquid chromatography-quadrupole/time of flight mass spectrometry (LC-Q/TOF) technique was used for metabolite identification. 5F-MDMB-PICA was detected and quantified in all analysed materials, whereas 4F-MDMB-BINACA was found only in cerebrospinal fluid. The determined concentrations of 5F-MDMB-PICA were 0.9 (blood), 0.1 (urine) and 3.2 ng/mL (cerebrospinal fluid). The concentration of 4F-MDMB-BINACA in cerebrospinal fluid was 0.1 ng/mL. The main metabolites of both compounds (hydrolysis and oxidative defluorination) were found in all analysed body fluids. Cerebrospinal fluid may be important alternative material in autopsy cases. Rapid elimination of 5F-MDMB-PICA and 4F-MDMB-BINACA compounds also means that the metabolite analysis can be crucial for the investigation. Laboratories must be made aware of their presence and incorporate these SCs and their metabolites into workflows for detection and confirmation. Ester hydrolysis and oxidative defluorination products can be found in blood, urine and cerebrospinal fluid making them useful biomarkers of intake.


Asunto(s)
Líquidos Corporales , Cannabinoides , Drogas Ilícitas , Masculino , Humanos , Adulto , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Líquidos Corporales/química , Líquidos Corporales/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA