RESUMEN

PURPOSE: Patients who wear an ocular prosthesis frequently suffer with dry eye symptoms and socket discharge, often on a daily basis. The aim of the study was to determine whether a smoother, optical quality polish of the prosthesis' surface could improve symptoms and wear tolerance. The study was designed as single-center, single-masked, prospective randomized controlled trial. Eighty-eight consecutive patients undergoing annual ocular prosthesis maintenance review were approached from the prosthesis clinic. Forty-one out of 49 eligible patients were recruited. METHODS: Participants were randomized to either a standard or a higher "optical quality" polish of their prosthesis. At entry to the trial, at 1 month, and 12 months they completed a questionnaire covering cleaning, lubricant use, inflammation, discomfort, and discharge. Lower scores indicated better tolerance of the prosthesis. At each visit, the prosthesis was stained and photographed against a standard background to assess deposit build up. Primary outcome measures were 1) a subjective questionnaire score and 2) an objective assessment of surface deposit build-up on prosthetic eyes by standardized photographic grading. RESULTS: Forty-one patients participated in the study. The median age of their prosthesis was 36 months (range 9 months-40 years). There was no statistically significant difference in questionnaire scores or deposit build up between the 2 groups at baseline. By 12-months, the higher optical quality polish showed a statistically significant reduction in symptoms and frequency of discharge (2.19 vs. 3.85; p = 0.05-lower scores better). Scoring of the prosthesis' deposit build-up showed a significant difference at 1 month, but this was not sustained at 12 months. CONCLUSIONS: Creating an optical quality finish to an ocular prosthesis reduces deposit build up on artificial eyes. The authors found this modification improved patient tolerance at 12 months.


Asunto(s)
Enfermedades de la Conjuntiva/prevención & control , Síndromes de Ojo Seco/prevención & control , Ojo Artificial/normas , Diseño de Prótesis , Propiedades de Superficie , Adulto , Anciano , Femenino , Humanos , Masculino , Microscopía Electroquímica de Rastreo , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos
2.
Vestn Oftalmol ; 133(5): 64-68, 2017.
Artículo en Ruso | MEDLINE | ID: mdl-29165415

RESUMEN

AIM: rectification of indications and contraindications for ectoprosthetics and exploration of its potential as a modern rehabilitation modality. MATERIAL AND METHODS: Here are summarized the results of 89 cases of facial reconstruction with prosthetic means in trauma patients and those who had had congenital or oncological pathology and in whom other methods of rehabilitation were unable to remedy the defect within the orbital region. RESULTS: The indications and contraindications for facial prosthetics as well as the conditions, under which this type of medical and social rehabilitation can be carried out, were clarified. The authors also explained the process of creating an epiprosthesis and how it should be attached to the orbit to have the maximum effect on the existing defects of both the bone and auxiliary apparatus (including eyelid soft tissues, eyelashes, etc.). Because modern ectoprostheses are made of silicone and held in place with magnets, they provide an optimal cosmetic result, so that, regardless of patient's age, no rough defects can be detected on the affected side at a 2-m distance. CONCLUSION: As the production technology develops, the cosmetic appearance of epiprostheses improves and their use broadens.


Asunto(s)
Ojo Artificial , Implantes Orbitales , Procedimientos de Cirugía Plástica , Adolescente , Adulto , Anoftalmos/complicaciones , Anoftalmos/rehabilitación , Niño , Ajuste Emocional , Ojo Artificial/psicología , Ojo Artificial/normas , Traumatismos Faciales/complicaciones , Traumatismos Faciales/rehabilitación , Neoplasias Faciales/complicaciones , Neoplasias Faciales/rehabilitación , Femenino , Humanos , Masculino , Enfermedades Orbitales/etiología , Enfermedades Orbitales/cirugía , Procedimientos de Cirugía Plástica/instrumentación , Procedimientos de Cirugía Plástica/métodos
3.
Appl Opt ; 56(15): 4338-4346, 2017 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-29047858

RESUMEN

We present an opto-mechanical artificial eye that can be used for examining multi-wavelength ophthalmic instruments. Standard off-the-shelf lenses and a refractive-index-matching fluid were used in the creation of the artificial eye. In addition to dispersive properties, the artificial eye can be used to simulate refractive error. To analyze the artificial eye, a multi-wavelength Hartmann-Shack aberrometer was used to measure the longitudinal chromatic aberration and the possibility of inducing refractive error. Off-axis chromatic aberrations were also analyzed by imaging through the artificial eye at two discrete wavelengths. Possible extensions to the dispersive artificial eye are also discussed.


Asunto(s)
Aberrometría/instrumentación , Ojo Artificial , Oftalmología/instrumentación , Diseño de Prótesis , Ojo Artificial/normas , Diseño de Prótesis/normas
4.
Optom Vis Sci ; 93(11): 1426-1430, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27525534

RESUMEN

PURPOSE: To develop a standardized and universally reproducible grading scale for artistic outcome of a custom ocular prosthesis. METHODS: A retrospective review of photographs of patients with custom ocular prosthesis. From the ocularistry database of a tertiary eye care hospital, photographs of patients with custom ocular prosthesis (30 random photos with additional 18 repetitions, total n = 50) were selected. Two independent oculoplastic surgeons, on the basis of characteristics of limbus, vascularity, and pigmentation, graded these photos. The photos were adjusted for confounders like magnification and illumination, and both graders used the same display system. The surgeons were blinded to each other. The characteristics were graded on a scale of 0 to 2 and total score was calculated for each photo. Inter-observer and intra-observer agreement was calculated using the kappa statistic. RESULTS: The inter-observer kappa coefficient for the three characteristics (95% confidence interval) were as follows: limbus 0.7 (0.55-0.85), vascularity 0.76 (0.58-0.94), and pigmentation 0.6 (0.34-0.85). The intra-observer kappa coefficient for the first surgeon was as follows: limbus 0.88 (0.7-0.95), vascularity 0.88 (0.73-0.95), and pigmentation 0.82 (0.54-0.93). The intra-observer kappa coefficient for the second surgeon was as follows: limbus 0.8 (0.44-0.93), vascularity 0.55 (0.13-0.8), and pigmentation 0.76 (0.6-0.84). CONCLUSIONS: A good intra- and inter-observer agreement was demonstrated. In view of no existing grading for prosthesis, this is a unique system to objectively grade the outcome of custom ocular prosthesis and can be incorporated in ocularistry teaching modules for standardization of outcomes.


Asunto(s)
Ojo Artificial/clasificación , Ojo Artificial/normas , Oftalmopatías/cirugía , Enucleación del Ojo , Evisceración del Ojo , Humanos , Variaciones Dependientes del Observador , Implantes Orbitales , Fotograbar , Ajuste de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
Rev. Assoc. Paul. Cir. Dent ; 70(2): 122-125, abr.-jun. 2016. ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-797061

RESUMEN

Objetivos: Este artigo visa exemplificar uma parceria internacional técnico cientifica por meio da utilização de técnica idealizada e patenteada por pesquisadores brasileiros. Materiais e Métodos: Um grupo de pesquisadores brasileiros idealizou, pesquisou e patenteou uma técnica de obtenção e utilização de íris digitalizada na reabilitação protética ocular. A internacionalização do método foi decorrente do intercâmbio estabelecido entre professores do Brasil e do México.A permanência do pesquisador mexicano, por um período em que especializou e concluiu o curso de mestrado, junto aos colegas brasileiros, pôde oferecer conhecimento e treinamento na aplicação da técnica proposta. Resultados: São apresentados casos clínicos em que a reabilitação protética ocular foi realizada usando a técnica brasileira de íris digitalizada. Conclusão:Pesquisas brasileiras, principalmente na área da saúde, vêm tendo destaque internacional. A preocupação com a melhora da qualidade de vida torna relevantes nossos estudos e técnica sem âmbito mundial.


Objectives: This article aims to illustrate a scientific technical international relation ship through the use of technique created and patented by Brazilian researchers. Materials and Methods: A group of Brazilian researchers devised, researched and patented a technique of obtaining and using scanned iris in ocular prosthetic rehabilitation. The internationalization of the technique was due to technical and scientific partner ship between Brazilian and Mexican researchers. A Mexican researcher remained for a period in which he specialized and completed his master’s course with the Brazilian team that was able to transfer knowledge and offer atraining in the application of the technique. Results: Three cases are shown, two Brazilian an done Mexican. Ocular Prosthetic rehabilitation of these cases was performed using the Brazilian technique of scanned iris. Conclusion: Brazilian research, especially in health, comes with international relevance. The concern with improving life quality makes our technical studies relevant world wide.


Asunto(s)
Humanos , Masculino , Femenino , Iris/metabolismo , Ojo Artificial/efectos adversos , Ojo Artificial/normas , Ojo Artificial , Rehabilitación/ética , Rehabilitación/instrumentación , Rehabilitación/métodos , Rehabilitación , Rehabilitación/tendencias
6.
Clin Exp Optom ; 96(1): 32-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22672062

RESUMEN

BACKGROUND: The aim was to develop tools to measure the condition of ocular prostheses and the socket's response to prosthetic eyewear. METHODS: A novel staining technique for displaying deposits on prosthetic eyes was developed. Equal interval perceptual grading scales for measuring inferior palpebral conjunctival inflammation, and anterior and posterior stained surface deposits on prosthetic eyes were developed from 800 photographs of 43 volunteers. The photographs for each scale were chosen by the authors. A group of four ophthalmologists, three optometrists and three senior students was consulted about selection criteria and asked to position the photographs along a 1.5 m rule to determine equal intervals. Photographs judged not to represent exactly equal perceptual intervals were exchanged with others from the original pool. The final scales (a five-photograph scale for inflammation and two 11 photograph scales for deposits) were assessed for inter-rater reliability and test-retest reliability by groups of senior optometry students. RESULTS: Standard deviations for inter-rater reliability tests were 0.52 scale units for the inflammation scale, 0.99 for the anterior surface deposits scale and 1.03 for the posterior surface deposits scale. The standard deviation of the test-retest differences for inflammation was 0.6 scale units and for both anterior and posterior surface deposits it was 0.71. CONCLUSIONS: A novel technique for displaying and measuring the intensity and extent of deposit formation on prosthetic eye surfaces has been described. The two equal interval perceptual grading scales that have been developed to quantify the extent of deposit formation together with the equal interval perceptual scale for grading severity of palpebral conjunctival inflammation will for the first time allow the effects of prosthetic eye wear to be evaluated. Further research to validate the scale for palpebral conjunctival inflammation in a clinical setting is recommended. The technique for staining deposits on prosthetic eyes is recommended for clinical practice.


Asunto(s)
Investigación Biomédica/métodos , Ojo Artificial/normas , Oftalmología/métodos , Optometría/métodos , Anoftalmos/cirugía , Humanos , Diseño de Prótesis , Reproducibilidad de los Resultados
7.
Ophthalmic Plast Reconstr Surg ; 13(1): 1-7, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9076776

RESUMEN

The Universal implant is a quasi-integrated buried orbital implant designed to provide the same motility advantages as does an Iowa implant, but is simpler to implant and associated with fewer complications. The protruding mounds on the implant are keyed to corresponding indentations on the posterior prosthetic surface, allowing more life-like motility. We describe a straight-forward technique for its use as an evisceration implant and report the results in 24 patients. The Universal implant is simple to use and the lock-and-key mechanism obtained between implant and prosthesis provides the patient with a high degree of life-like motility. Its cost is significantly lower than the more popular hydroxyapatite implant and it does not require a drilling procedure for coupling.


Asunto(s)
Evisceración del Ojo/métodos , Prótesis e Implantes/normas , Adulto , Ojo Artificial/normas , Estudios de Seguimiento , Humanos , Masculino , Satisfacción del Paciente , Prótesis e Implantes/economía , Diseño de Prótesis , Estudios Retrospectivos
8.
Ophthalmic Surg Lasers ; 28(2): 171-3, 1997 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9054494

RESUMEN

The loss of an eye is an emotionally traumatic event. A prosthetic eye is usually not fitted until the socket has healed (about 6 weeks after surgery). This period, during which a clear conformer is fitted, can be particularly traumatic, especially for the newly anophthalmic patient. The authors have designed interim acrylic prosthetic conformers to help patients overcome some of these problems while preserving the necessary characteristics of ideal postoperative conformers.


Asunto(s)
Color del Ojo , Ojo Artificial/normas , Adulto , Femenino , Estudios de Seguimiento , Humanos , Satisfacción del Paciente
9.
Arch Otolaryngol Head Neck Surg ; 122(1): 46-50, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8554746

RESUMEN

OBJECTIVE: To evaluate the use of endosseous transcutaneous implants to retain removable facial prostheses for the rehabilitation of orbital defects. SETTING: Tertiary referral center. PATIENTS: Six patients with a history of facial defects secondary to orbital exenteration for cancer ablation. OUTCOME MEASURES: Clinically noted functional and cosmetic results, patient reports of satisfaction, and complications encountered. RESULTS: Twenty-three of 25 implants were integrated (postoperative period, 13 to 65 months; mean, 44.2 months), representing an integration success rate of 92%. All patients were successfully wearing implant-retained prostheses after 48.3 months (post-prosthesis delivery period, 1 to 48.3 months; mean, 24.5 months). Overall patient satisfaction was very high. CONCLUSIONS: Implant-retained prosthetics represent a safe and effective treatment option. It is anticipated that this treatment will become the standard of rehabilitative care for patients with orbital defects.


Asunto(s)
Ojo Artificial/normas , Evisceración Orbitaria/rehabilitación , Neoplasias Orbitales/cirugía , Oseointegración , Adulto , Anciano , Ojo Artificial/efectos adversos , Ojo Artificial/psicología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Evisceración Orbitaria/efectos adversos , Satisfacción del Paciente
10.
Eye (Lond) ; 10 ( Pt 1): 29-37, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8763300

RESUMEN

The hydroxyapatite orbital implant was first released for use as an orbital implant in humans in August 1989. It has been shown to be well tolerated, providing good motility of the artificial eye with a low complication rate when used as a primary implant. This prospective study evaluated the hydroxyapatite orbital implant used as both a primary and a secondary implant. Sixty patients were implanted between October 1992 and November 1994, 28 being implanted as a primary procedure at the time of enucleation or evisceration, and 32 as a secondary procedure. Seven patients underwent second-stage drilling and pegging of the implant. The mean follow-up time was 13 months (range 2-26 months). A standardised operative and post-operative protocol was followed. The patients were evaluated post-operatively for the amount of enophthalmos, degree of upper lid sulcus deformity, motility of the prosthesis, location of the implant in the socket, socket status and the presence or absence of discharge, position of the drill hole and coverage of the implant. Complications and their management were documented. Both patient and surgeon made a subjective assessment of cosmesis and the patient's satisfaction with the overall result was noted. The results of this study show the hydroxyapatite orbital implant to provide excellent motility of the artificial eye and good cosmesis with a low rate of complications when used both as a primary and as a secondary implant.


Asunto(s)
Materiales Biocompatibles , Enucleación del Ojo , Evisceración del Ojo , Ojo Artificial/normas , Adolescente , Adulto , Anciano , Niño , Preescolar , Estética , Enucleación del Ojo/rehabilitación , Evisceración del Ojo/rehabilitación , Párpados/cirugía , Femenino , Humanos , Hidroxiapatitas , Masculino , Persona de Mediana Edad , Estudios Prospectivos
11.
Insight ; 17(1): 25-8, 1992 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-1564367

RESUMEN

As treatment modalities evolve in ophthalmology one must assess and re-evaluate current methods of therapy in the care and treatment of the patient facing the loss of an eye. With the advent of Hydroxyapatite Orbital Implants, new challenges face the ophthalmic nurse in caring for the patient undergoing enucleation and reconstructive surgery. Integrated orbital implants are used to replace the volume of the orbit when the eye is removed due to enucleation, evisceration, or as secondary orbital implants. Various materials have been used in the past to replace orbital volume, with the most common being silicone or polymethylmethacrylate. Hydroxyapatite is a new orbital implant material which has unique interconnected porous matrix derived from marine corals with a mineral composition similar to bone. This orbital implant undergoes fibrovascular ingrowth by the patient's own tissue, becoming truly integrated and less likely to reject, migrate or extrude. The hydroxyapatite implant may be inserted with a variety of surgical techniques, all of which are more complex than standard enucleation implant techniques and have special considerations for the ophthalmic registered nurse.


Asunto(s)
Enucleación del Ojo/métodos , Ojo Artificial/normas , Hidroxiapatitas/normas , Enucleación del Ojo/enfermería , Humanos , Cuidados Posoperatorios
12.
Ann Plast Surg ; 26(6): 561-3, 1991 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-1883164

RESUMEN

Two methylmethacrylate orbital implants used for 34 and 5 years, respectively, were examined with a scanning electron microscope. One of the implants was a combination of a prosthesis and an implant containing a magnet. The magnetic force had decreased markedly, and rust crystals were apparent. The methylmethacrylate surface was irregular and rough.


Asunto(s)
Oftalmopatías/cirugía , Enucleación del Ojo/rehabilitación , Cuerpos Extraños en el Ojo/complicaciones , Ojo Artificial/normas , Magnetismo , Metilmetacrilatos , Siderosis/cirugía , Oftalmopatías/etiología , Humanos , Masculino , Metilmetacrilato , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Siderosis/etiología , Propiedades de Superficie
13.
Arch. chil. oftalmol ; 46(2): 121-3, dic. 1989. tab, ilus
Artículo en Español | LILACS | ID: lil-111377

RESUMEN

Se presentan diez casos de pacientes portadores de un síndrome de la órbita anoftálmica caracterizado por: depresión del surco supratarsal, enoftalmos y descenso variable de uno o ambos párpados. Se describe la técnica quirúrgica y los materiales empleados para corregir el defecto estético, sus resultados y complicaciones


Asunto(s)
Adulto , Persona de Mediana Edad , Humanos , Masculino , Femenino , Anoftalmos/cirugía , Ojo Artificial/normas
14.
In. Brandäo, Lenine Garcia; Ferraz, Alberto R. Cirurgia de cabeça e pescoço: princípios básicos. Säo Paulo, Roca, 1989. p.701-23, ilus.
Monografía en Portugués | LILACS, BBO - Odontología | ID: lil-255859
16.
In. Fonseca, Edmundo Pinto da. Prótese ocular. Säo Paulo, Panamed, 1987. p.15-6.
Monografía en Portugués | LILACS, BBO - Odontología | ID: lil-255994
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA