Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.716
Filtrar
1.
J Orthop Trauma ; 38(7): 345-350, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38837208

RESUMEN

OBJECTIVES: Evaluate if nonoperative or operative treatment of displaced clavicle fractures delivers reduced rates of nonunion and improved Disability of the Arm, Shoulder, and Hand (DASH) scores. DESIGN: Multicenter, prospective, observational. SETTING: Seven Level 1 Trauma Centers in the United States. PATIENT SELECTION CRITERIA: Adults with closed, displaced (100% displacement/shortened >1.5 cm) midshaft clavicle fractures (Orthopaedic Trauma Association 15.2) were treated nonoperatively, with plates and screw fixation, or with intramedullary fixation from 2003 to 2018. OUTCOME MEASURES AND COMPARISONS: DASH scores (2, 6 weeks, 3, 6, 12, and 24 months), reoperation, and nonunion were compared between the nonoperative, plate fixation, and intramedullary fixation groups. RESULTS: Four hundred twelve patients were enrolled, with 203 undergoing plate fixation, 26 receiving intramedullary fixation, and 183 treated nonoperatively. The average age of the nonoperative group was 40.1 (range 18-79) years versus 35.8 (range 18-74) in the plate group and 39.3 (range 19-56) in the intramedullary fixation group (P = 0.06). One hundred forty (76.5%) patients in the nonoperative group were male compared with 154 (75.9%) in the plate group and 18 (69.2%) in the intramedullary fixation group (P = 0.69). All groups showed similar DASH scores at 2 weeks, 12 months, and 24 months (P > 0.05). Plate fixation demonstrated better DASH scores (median = 20.8) than nonoperative (median = 28.3) at 6 weeks (P = 0.04). Intramedullary fixation had poorer DASH scores at 6 weeks, 3 months, and 6 months than plate fixation and worse DASH scores than nonoperative at 6 months (P < 0.05). The nonunion rate for nonoperative treatment (14.6%) was significantly higher than the plate group (0%) (P < 0.001). CONCLUSIONS: Operative treatment of displaced clavicle fractures provided lower rates of nonunion than nonoperative treatment. Except at 6 weeks, no difference was observed in DASH scores between plate fixation and nonoperative treatment. Intramedullary fixation resulted in worse DASH scores than plate fixation at 6 weeks, 3 months, and 6 months and worse DASH scores than nonoperative at 6 months. Implant removal was the leading reason for reoperation in the plate and intramedullary fixation groups, whereas surgery for nonunion was the primary reason for surgery in the nonoperative group. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Placas Óseas , Clavícula , Fijación Intramedular de Fracturas , Fracturas Óseas , Humanos , Clavícula/lesiones , Clavícula/cirugía , Adulto , Estudios Prospectivos , Persona de Mediana Edad , Masculino , Femenino , Fracturas Óseas/cirugía , Anciano , Fijación Intramedular de Fracturas/métodos , Adulto Joven , Adolescente , Resultado del Tratamiento , Tornillos Óseos , Fijación Interna de Fracturas/métodos
2.
BMJ Case Rep ; 17(6)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839412

RESUMEN

Fractures of the proximal humerus with medial column instability are challenging and present an unacceptable rate of complications and reoperations. Despite good results reported with the use of locking plates and augmentation techniques using bone graft or a second plate, varus subsidence and fixation failure have been frequently reported. We describe the case of a patient presenting with a complex, multifragmentary proximal humerus fractures successfully treated with open anatomic reduction and internal fixation using a locking plate augmented with lateral traction using three bone anchors in the humerus head. After 18 months, the patient reported fully recovering the mobility and functionality of the operated shoulder. The use of bone anchors pulling the humeral in three different directions like three vectors applied from medial to lateral, posterior to anterior and lateral to anterior help to reduce the most important deformities (varus and retroversion) by applying the tension band principle. This is an interesting approach to avoid primary and secondary reduction loss of the proximal fractures of the humerus with postero-medial cortical defect. The procedure is a good alternative to be used in patients with failure or insufficiency of the medial wall and marked varus.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Fijación Interna de Fracturas/métodos , Placas Óseas , Técnicas de Sutura , Masculino , Inestabilidad de la Articulación/cirugía , Anclas para Sutura , Persona de Mediana Edad , Resultado del Tratamiento
3.
Clin Orthop Surg ; 16(3): 493-505, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38827752

RESUMEN

Background: Distal metaphyseal-diaphyseal junction fractures of the humerus are a subset of injuries between humeral shaft fractures and distal intra-articular humerus fractures. A lack of space for distal fixation and the unique anatomy of concave curvature create difficulties during operative treatment. The closely lying radial nerve is another major concern. The aim of this study was to determine whether anterolateral dual plate fixation could be effective for a distal junctional fracture of the humerus both biomechanically and clinically. Methods: A right humerus 3-dimensional (3D) model was obtained based on plain radiographs and computed tomography data of patients. Two fractures, a spiral type and a spiral wedge type, were constructed. Three-dimensional models of locking compression plates and screws were constructed using materials provided by the manufacturer. The experiment was conducted by using COMSOL Multiphysics, a finite element analysis, solver, and simulation software package. For the clinical study, from July 2008 to March 2021, a total of 72 patients were included. Their medical records were retrospectively reviewed to obtain patient demographics, elbow range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) scores, Mayo Elbow Performance Scores (MEPS), and hand grip strength. Results: No fracture fixation construct completely restored stiffness comparable to the intact model in torsion or compression. Combinations of the 7-hole and 5-hole plates and the 8-hole and 6-hole plates showed superior structural stiffness and stress than those with single lateral plates. At least 3 screws (6 cortices) should be inserted into the lateral plate to reduce the load effectively. For the anterior plate, it was sufficient to purchase only the near cortex. Regarding clinical results of the surgery, the range of motion showed satisfactory results in elbow flexion, elbow extension, and forearm rotation. The average DASH score was 4.3 and the average MEPS was 88.2. Conclusions: Anterolateral dual plate fixation was biomechanically superior to the single-plate method in the finite element analysis of a distal junctional fracture of the humerus model. Anterolateral dual plate fixation was also clinically effective in a large cohort of patients with distal junctional fractures of the humerus.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Fracturas del Húmero , Humanos , Fracturas del Húmero/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Masculino , Persona de Mediana Edad , Femenino , Adulto , Estudios Retrospectivos , Fenómenos Biomecánicos , Anciano , Rango del Movimiento Articular , Húmero/cirugía
4.
J Feline Med Surg ; 26(5): 1098612X241243134, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717791

RESUMEN

CASE SERIES SUMMARY: A total of 13 cases of cats with a caudal mandibular fracture treated with a novel surgical technique using the Ramus Anatomical Plate system were reviewed. Preoperative, immediate postoperative and a minimum of 8 weeks postoperative CT images were required as inclusion criteria. The outcome and complications were determined from clinical data and radiographic follow-up examinations. All cases achieved adequate anatomical reduction, resulting in a functional and atraumatic occlusion postoperatively. No intraoperative complications were reported. Time to voluntary food intake was in the range of 1-25 days. No evidence of disruptions to the implants or screw loosening was observed in the 8-week postoperative CT imaging, with radiographic evidence of complete osseous union in all fractures. The most common postoperative complication was swelling at the surgical site. Two cats had postoperative exophthalmos due to retrobulbar haemorrhage, and one cat exhibited partial wound dehiscence 5 days postoperatively, which resolved with medical management. Longer-term complications included intraoral plate exposure in one cat, which required plate removal 10 months postoperatively. RELEVANCE AND NOVEL INFORMATION: In this case series, rigid internal fixation of caudal mandibular fractures using the Ramus Anatomical Plate osteosynthesis system was associated with a minimal complication rate, and satisfactory radiographic and clinical outcomes. The reported outcomes of this novel technique are favourable when compared with previous techniques described for the management of these fracture types.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Mandibulares , Gatos/lesiones , Animales , Placas Óseas/veterinaria , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Fracturas Mandibulares/veterinaria , Fracturas Mandibulares/cirugía , Masculino , Femenino , Resultado del Tratamiento , Complicaciones Posoperatorias/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Enfermedades de los Gatos/cirugía
5.
Dan Med J ; 71(5)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38704836

RESUMEN

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Humanos , Rótula/lesiones , Rótula/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Estudios Prospectivos , Femenino , Masculino , Resultado del Tratamiento , Hilos Ortopédicos , Adulto , Ensayos Clínicos Controlados Aleatorios como Asunto , Persona de Mediana Edad , Dinamarca , Calidad de Vida , Fractura de Rótula
6.
J Med Life ; 17(2): 188-194, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38813362

RESUMEN

This study aimed to share our experience of a self-developed plate for acetabular fracture fixation through the presentation of clinical cases. Eight patients with complex acetabular fractures (Letournel classification) underwent surgery using a modified Stoppa approach and the novel plate design between 2021 and 2023 at the National Scientific Center for Traumatology and Orthopedics. Criteria such as the mechanism of injury, type of fracture, surgical approach, intraoperative and postoperative complications, quality of reduction, and functional and radiological results were evaluated. All patients included in the study presented complex types of acetabular fractures according to the Letournel classification. In all cases, surgical interventions were performed using a modified Stoppa approach. The assessment of reduction quality was conducted based on the radiological standards established by Matta. The reduction in quality was excellent in two patients, good in four, and satisfactory in two. One patient developed a post-traumatic false joint requiring additional surgery. The remaining patients achieved fracture healing with satisfactory Harris Hip Score (HHS) scores, indicating good overall function. The results of the self-developed plate for acetabular fracture fixation in our series were satisfactory.


Asunto(s)
Acetábulo , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Acetábulo/cirugía , Acetábulo/lesiones , Masculino , Adulto , Femenino , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Persona de Mediana Edad , Adulto Joven
7.
J Orthop Surg Res ; 19(1): 313, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38802866

RESUMEN

BACKGROUND: The use of continuous passive motion therapy (CPM) has led to promising results in the early phase of rehabilitation after surgical treatment of rotator cuff tears and arthrolysis of the elbow. However, its use has not been proven in other pathologies of the upper extremity. Therefore, the aim of the underlying study was to evaluate the use of CPM therapy after plate osteosynthesis of proximal humeral fractures. METHODS: 95 patients with isolated proximal humerus fractures were enrolled in a prospective, randomized study. Patients were assigned to a treatment group with (n = 48, CPM) or without CPM therapy (n = 47, CG). Four patients (2 of each cohort) violated the study protocol and were excluded. CPM therapy was used for 6 weeks after surgery 2-3 times daily. Functional (range of motion) and patient reported outcomes (PROM, Constant Score [CSS], QuickDASH, subjective shoulder value [SSV], pain on visual analogue scale [VAS]) were evaluated at 6 weeks, 3 and 12months. 60 patients completed the 1-year follow-up. RESULTS: The average patient age was 65.3 years (min: 27, max: 88, SD: ± 14.7). Seventy-two patients were female (79%). There was no difference regarding injury severity (2/3/4 part-fracture: 6/32/7 vs. 9/26/11, p = 0.867) and sex (p = 0.08). However, patients in the CPM group were significantly younger (CPM: 67 [min: 34, max: 82], CG: 74 [min: 27, max: 88], p = 0.032). After 6 weeks we observed a better range of motion for forward flexion (CPM: 90° [min: 50°, max: 180°] vs. CG: 80° [min: 20°, max: 170°] p = 0.035) and abduction (CPM: 80° [min: 40°, max: 180°] vs. CG: 70° [min: 20°, max: 180°], p = 0.048) in the CPM group. There was no difference regarding the further planes of motion or the assessed PROMs at 6 weeks. At 3 and 12 months the results between the treatment groups equalized with no further significant differences. CONCLUSION: The treatment with CPM increases the range of motion after plate osteosynthesis of proximal humerus fractures in the first 6 weeks after surgery. This effect is not sustained after 3 and 12months. The evaluated PROMs are not being influenced by CPM therapy. Hence the results of this prospective randomized study suggest that CPM can be a beneficial asset in the early period of rehabilitation after proximal humerus plate osteosynthesis. TRIAL REGISTRATION: The study protocol was registered in the US National Institutes of Health's database ( http://www. CLINICALTRIALS: gov ) registry under NCT05952622.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Terapia Pasiva Continua de Movimiento , Rango del Movimiento Articular , Fracturas del Hombro , Humanos , Persona de Mediana Edad , Anciano , Femenino , Masculino , Estudios Prospectivos , Fracturas del Hombro/cirugía , Fracturas del Hombro/rehabilitación , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/rehabilitación , Terapia Pasiva Continua de Movimiento/métodos , Adulto , Anciano de 80 o más Años , Resultado del Tratamiento , Recuperación de la Función , Factores de Tiempo , Estudios de Seguimiento
8.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747532

RESUMEN

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Mal Unidas , Osteotomía , Fracturas del Radio , Humanos , Femenino , Osteotomía/métodos , Osteotomía/instrumentación , Persona de Mediana Edad , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Anciano , Fracturas Mal Unidas/cirugía , Fracturas Mal Unidas/diagnóstico por imagen , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Impresión Tridimensional , Cirugía Asistida por Computador , Imagenología Tridimensional , Tornillos Óseos , Tomografía Computarizada por Rayos X
9.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 529-534, 2024 May 15.
Artículo en Chino | MEDLINE | ID: mdl-38752237

RESUMEN

Objective: To evaluate the safety and effectiveness of applying self-stabilizing zero-profile three-dimensional (3D) printed artificial vertebral bodies in anterior cervical corpectomy and fusion (ACCF) for cervical spondylotic myelopathy. Methods: A retrospective analysis was conducted on 37 patients diagnosed with cervical spondylotic myelopathy who underwent single-level ACCF using either self-stabilizing zero-profile 3D-printed artificial vertebral bodies ( n=15, treatment group) or conventional 3D-printed artificial vertebral bodies with titanium plates ( n=22, control group) between January 2022 and February 2023. There was no significant difference in age, gender, lesion segment, disease duration, and preoperative Japanese Orthopedic Association (JOA) score between the two groups ( P>0.05). Operation time, intraoperative bleeding volume, hospitalization costs, JOA score and improvement rate, incidence of postoperative prosthesis subsidence, and interbody fusion were recorded and compared between the two groups. Results: Compared with the control group, the treatment group had significantly shorter operation time and lower hospitalization costs ( P<0.05); there was no significant difference in intraoperative bleeding volume between the two groups ( P>0.05). All patients were followed up, with a follow-up period of 6-21 months in the treatment group (mean, 13.7 months) and 6-19 months in the control group (mean, 12.7 months). No dysphagia occurred in the treatment group, while 5 cases occurred in the control group, with a significant difference in the incidence of dysphagia between the two groups ( P<0.05). At 12 months after operation, both groups showed improvement in JOA scores compared to preoperative scores, with significant differences ( P<0.05); however, there was no significant difference in the JOA scores and improvement rate between the two groups ( P>0.05). Radiographic examinations showed the interbody fusion in both groups, and the difference in the time of interbody fusion was not significant ( P>0.05). At last follow-up, 2 cases in the treatment group and 3 cases in the control group experienced prosthesis subsidence, with no significant difference in the incidence of prosthesis subsidence ( P>0.05). There was no implant displacement or plate-screw fracture during follow-up. Conclusion: The use of self-stabilizing zero-profile 3D-printed artificial vertebral bodies in the treatment of cervical spondylotic myelopathy not only achieves similar effectiveness to 3D-printed artificial vertebral bodies, but also reduces operation time and the incidence of postoperative dysphagia.


Asunto(s)
Vértebras Cervicales , Descompresión Quirúrgica , Impresión Tridimensional , Fusión Vertebral , Espondilosis , Humanos , Espondilosis/cirugía , Vértebras Cervicales/cirugía , Estudios Retrospectivos , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Masculino , Descompresión Quirúrgica/métodos , Femenino , Resultado del Tratamiento , Placas Óseas , Cuerpo Vertebral/cirugía , Enfermedades de la Médula Espinal/cirugía , Persona de Mediana Edad
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 535-541, 2024 May 15.
Artículo en Chino | MEDLINE | ID: mdl-38752238

RESUMEN

Objective: To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods: A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C 2-7Cobb angle ( P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C 2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results: The operation time and incidence of complications were significantly lower in the study group than in the control group ( P<0.05), while the difference in intraoperative blood loss between the two groups was not significant ( P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference ( t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences ( P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group ( P<0.05); but there was no significantly difference in VAS score and NDI between the two groups ( P>0.05). Imaging re-examination showed that the vertebral height and C 2-7Cobb angle of the two groups significantly increased at 3 and 12 months after operation ( P<0.05), and there was no significant difference between 3 and 12 months after operation ( P>0.05). At each time point, the vertebral height and C 2-7Cobb angle of the study group were significantly higher than those of the control group ( P<0.05), and the implant subsidence rate was significantly lower than that of the control group ( P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups ( P>0.05). Conclusion: Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.


Asunto(s)
Aleaciones , Vértebras Cervicales , Osificación del Ligamento Longitudinal Posterior , Impresión Tridimensional , Fusión Vertebral , Titanio , Humanos , Osificación del Ligamento Longitudinal Posterior/cirugía , Vértebras Cervicales/cirugía , Estudios Retrospectivos , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Descompresión Quirúrgica/métodos , Hueso Esponjoso , Resultado del Tratamiento , Cuerpo Vertebral/cirugía , Femenino , Masculino , Placas Óseas , Persona de Mediana Edad
11.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 613-617, 2024 May 15.
Artículo en Chino | MEDLINE | ID: mdl-38752250

RESUMEN

Objective: To summarize the research progress in the treatment of distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children and to provide reference for clinical practice. Methods: The characteristics and treatment methods of transverse and comminuted DHMDJ fractures in children were summarized and analyzed by referring to relevant literature at home and abroad. Results: DHMDJ fractures in children are not uncommon clinically, with high fracture line position, multi-directional instability, difficult closed reduction in treatment, and easy to cause complications such as coronal and sagittal deformity of the elbow. The Kirschner wire technique was effective for DHMDJ fractures with the fracture line at the middle and low levels, but was prone to iatrogenic ulnar nerve injury. Elastic stable intramedullary nail is suitable for higher-position transverse DHMDJ fractures. However, this technique requires a second operation to remove the internal fixator, and may cause iatrogenic epiphysis plate injury in children. External fixator is a new way to treat DHMDJ fractures, and it can show satisfactory results for transverse and comminuted DHMDJ fractures. However, at present, there are few relevant studies, and most of them focus on biomechanical studies, and the efficacy lacks high-quality clinical research support. Conclusion: The ultimate goal of DHMDJ fracture treatment in children is to restore the anatomical alignment of the fracture and prevent the loss of reduction. The choice of internal fixator depends on the location of the fracture line and the shape of the fracture to provide personalized treatment.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Húmero , Humanos , Niño , Fracturas del Húmero/cirugía , Fijación Interna de Fracturas/métodos , Hilos Ortopédicos , Fijadores Externos , Diáfisis/lesiones , Fracturas Conminutas/cirugía , Fijación Intramedular de Fracturas/métodos , Resultado del Tratamiento , Placas Óseas , Clavos Ortopédicos , Fijadores Internos , Preescolar , Articulación del Codo/cirugía , Curación de Fractura
12.
Medicine (Baltimore) ; 103(20): e38252, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758854

RESUMEN

The management of comminuted quadrilateral fractures remains challenging, and treatment options are constantly evolving. The purpose of the present study was to examine the outcomes of 2 different fixation techniques in the management of comminuted quadrilateral fractures. Twenty-two patients with comminuted quadrilateral acetabular fractures were surgically treated with interfragmentary lag screw (group 1) and square bracket-shaped tubular (SBST) plate technique (group 2), in addition to suprapectineal and infrapectineal pelvic reconstruction plate fixation between January 2016 and July 2019 at our clinic. 2 years follow-up control data of each group were compared in terms of radiological and functional results, and complications. According to the functional score comparison, the mean Merle d'Aubigne Postel scoring system (MAP) score was 15.2/15.6 (P = .632), and the mean Harris hip scoring (HHS) system score was 74.65/77.3 (P = .664) in groups 1 and 2, respectively. Radiological comparison was performed according to matta radiological criteria (MRC), and 2 excellent, 6 good, 2 poor, 4 excellent, 4 good, and 4 poor radiological results were observed in groups 1 and 2, respectively. intraarticular screw penetration was detected in 3 patients in group 1, while there was no articular implant penetration in group 2 (P = .001). We believe that satisfactory results can be obtained with the SBST plate technique, offering functional and clinical outcomes that are similar to those of the interfragmentary screw technique. The SBST plate technique is superior in terms of avoiding intraarticular screw penetration and related revision surgery.


Asunto(s)
Acetábulo , Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas Conminutas , Humanos , Acetábulo/cirugía , Acetábulo/lesiones , Acetábulo/diagnóstico por imagen , Femenino , Masculino , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Persona de Mediana Edad , Adulto , Fracturas Conminutas/cirugía , Fracturas Conminutas/diagnóstico por imagen , Resultado del Tratamiento , Estudios Retrospectivos , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen
13.
Cir Cir ; 92(2): 211-218, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38782385

RESUMEN

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Asunto(s)
Placas Óseas , Hilos Ortopédicos , Fijación Interna de Fracturas , Cóndilo Mandibular , Fracturas Mandibulares , Acero Inoxidable , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas Mandibulares/cirugía , Cóndilo Mandibular/lesiones , Cóndilo Mandibular/cirugía , Masculino , Femenino , Adulto , Persona de Mediana Edad , Titanio , Rango del Movimiento Articular , Clavos Ortopédicos , Adulto Joven , Estudios Retrospectivos
14.
Zhongguo Gu Shang ; 37(5): 451-7, 2024 May 25.
Artículo en Chino | MEDLINE | ID: mdl-38778527

RESUMEN

OBJECTIVE: To explore the clinical efficacy of antibiotic bone cement covered reconstruction steel plate in the treatment of infected anterior pelvic ring fracture. METHODS: From January 2017 to March 2022, 11 patients with infected anterior pelvic ring fracture were treated with antibiotic bone cement covered reconstruction steel plate including 7 males and 4 females and the age ranged from 27 to 49 years old. The pelvic fractures were classified according to the Tile typology: 4 cases of C1 type, 4 cases of C2 type, and 3 cases of C3 type. Among them, 2 cases of infected anterior ring were infected after internal fixation of anterior ring, and 9 patients were infected with infected anterior ring due to incomplete early debridement, which was classified as infected according to the injury severity score(ISS) for 24 to 38 scores. The anterior ring was internally fixed by extended debridement, irrigation, and antibiotic bone cement covered reconstruction plate, and the posterior ring fractures were all closed reduction and internally fixed with sacroiliac screws. RESULTS: All 11 cases obtained follow-up from 13 to 20 months. Among them, 2 patients had recurrence of postoperative infection, 1 case was re-dissected and replaced with antibiotic bone cement-coated internal fixation, and 1 case had a milder infection without accumulation of the medullary cavity, and the infection was controlled by retaining the plate and replacing the antibiotic bone cement only after dissecting. Two cases developed incisional oozing, which healed after removal of the internal fixation three months postoperatively. All patients did not show pelvic fracture redisplacement or reinfection during the follow-up period. All 11 cases eventually healed bony. At the final follow-up, according to the Matta score, the fracture reduction was excellent in 6 cases, good in 4, and possible in 1. According to the Majeed functional score, it was excellent in 6, good in 3, and possible in 2. CONCLUSION: Antibiotic bone cement covered reconstruction plate is effective in the treatment of infected anterior pelvic ring fracture, with high intraoperative safety and low recurrence rate of infection, which is conducive to the early postoperative rehabilitation and significantly shortens the course of the disease.


Asunto(s)
Antibacterianos , Cementos para Huesos , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Huesos Pélvicos , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Fracturas Óseas/cirugía , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Fijación Interna de Fracturas/métodos , Procedimientos de Cirugía Plástica/métodos
15.
Clin Podiatr Med Surg ; 41(3): 407-423, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38789161

RESUMEN

Lisfranc injuries were thought to primarily occur during high-energy events, leading to a preference for fusion treatment; however, recent data have shifted this perspective by highlighting a greater occurrence of low-energy injuries and reshaping the focus on open reduction internal fixation. This multifaceted process is guided by various factors, including the nature of the injury, specific anatomic considerations, and the involved joints. Our overarching goal remains to achieve anatomic reduction, with flexibility in hardware fixation methods. In cases of comminution, bridge plating may be warranted, potentially followed by arthrodesis in the future.


Asunto(s)
Fijación Interna de Fracturas , Humanos , Fijación Interna de Fracturas/métodos , Artrodesis/métodos , Traumatismos de los Pies/cirugía , Traumatismos de los Pies/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Reducción Abierta/métodos , Huesos Metatarsianos/lesiones , Huesos Metatarsianos/cirugía , Masculino , Placas Óseas
16.
BMC Surg ; 24(1): 157, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755649

RESUMEN

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Asunto(s)
Acetábulo , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Impresión Tridimensional , Humanos , Estudios Retrospectivos , Acetábulo/cirugía , Acetábulo/lesiones , Masculino , Femenino , Adulto , Persona de Mediana Edad , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Resultado del Tratamiento , Fracturas Óseas/cirugía , Tempo Operativo , Adulto Joven , Diseño de Prótesis , Anciano
17.
Prog Orthod ; 25(1): 19, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38797777

RESUMEN

BACKGROUND: Skeletal anterior open bite (SAOB) represents one of the most complex and challenging malocclusions in orthodontics. Orthodontic treatment supported by miniplates enable to reduce the need for orthognathic surgery. Transverse dimension may be affected by intrusion biomechanics. This study aims to assess transverse bone alterations in patients with SAOB who underwent orthodontic treatment with absolute anchorage using four miniplates. METHODS: A total of 32 patients of both sexes, with an average age of 33.8 years, diagnosed with SAOB and treated orthodontically with four miniplates (one in each hemiarch), were selected for this study. Tomographic examinations were performed before (T1) and after (T2) orthodontic treatment. Linear measurements (width of the maxillary base, maxillary alveolar, maxillary root, maxillary dental cusp, mandibular alveolar) and angular measurements (maxillary intermolar angle) were assessed in these images. The Shapiro-Wilks normality tests were applied to verify data distribution, and the paired t-test was used to compare the initial and final measures obtained. RESULTS: Among the evaluated parameters, the maxillary alveolar width, maxillary dental cusp width, mandibular alveolar cusp width, and intermolar angle showed statistically significant differences between T1 and T2 (p < 0.05). However, maxillary base and maxillary root widths showed no significant difference (p > 0.05). CONCLUSIONS: Intrusion and distalization with miniplates in SAOB therapy may lead to significant expansive changes, due to molars cusps width and buccal inclination increase restricted at the alveolar level.


Asunto(s)
Placas Óseas , Mandíbula , Mordida Abierta , Métodos de Anclaje en Ortodoncia , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Masculino , Femenino , Mordida Abierta/terapia , Mordida Abierta/diagnóstico por imagen , Adulto , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Cefalometría , Proceso Alveolar/diagnóstico por imagen , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven , Diseño de Aparato Ortodóncico
18.
Musculoskelet Surg ; 108(2): 231-238, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38702586

RESUMEN

PURPOSE: There are still controversies on the effect of grafting during open reduction and internal fixation of calcaneal fractures. The aim of this study was to compare the radiological and functional outcomes in patients with or without intraoperative grafting. METHODS: In a comparative retrospective study, among 442 operatively-treated calcaneal fractures, 60 patients with unilateral closed sanders type II intraarticular calcaneal fracture who underwent ORIF via lateral extensile approach using locking anatomical plates with at least 1 year follow-up without any postoperative wound complication were enrolled. The patients were separated into 2 groups: with bone allograft and without bone allograft. The functional outcome of the patients was assessed using visual analog scale (VAS) for pain, the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, foot function index (FFI), and short-form (SF-36) health survey. Radiographic variables included Böhler angle, Gissane angle, calcaneal width, calcaneal height, and talar declination angle. Also, the differences (delta) of these values in comparison to the uninjured foot were calculated. RESULTS: The mean age was 39.1 ± 12.7 (range, 13-67) years with 54 males, 90.0%. No statistically significant differences were detected in age, gender, affected side, and subtypes of calcaneal fractures between the two groups (p > 0.05). The average follow-up was 25.1 (range, 12-48) months. The differences for all radiographic measurements and also, the delta values between the groups were not statistically significant, except talar declination angle which was more in cases without grafting (p = 0.007). Although the differences between the two groups regarding AOFAS ankle-hindfoot scale (p = 0.257), VAS for pain (p = 0.645), and FFI (p = 0.261) were not statistically significant; the group with bone graft experienced less pain (19.7 ± 22.0) than the other group (26.7 ± 22.8). The difference between the groups was not statistically significant (p = 0.87) according to the SF-36 questionnaire. CONCLUSIONS: Incorporating allografts into the void defects during ORIF of displaced intraarticular calcaneal fractures may not improve functional outcomes and recover postoperative radiological parameters. Therefore, routine use of allograft to fill the defects during ORIF of calcaneus may not be recommended. Of note, that these findings solely relate to the treatment of Sanders type II fractures. LEVEL OF EVIDENCE III: Comparative retrospective study.


Asunto(s)
Trasplante Óseo , Calcáneo , Fijación Interna de Fracturas , Fracturas Óseas , Reducción Abierta , Humanos , Calcáneo/lesiones , Calcáneo/diagnóstico por imagen , Masculino , Fijación Interna de Fracturas/métodos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Adulto , Trasplante Óseo/métodos , Anciano , Reducción Abierta/métodos , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Adolescente , Adulto Joven , Resultado del Tratamiento , Estudios de Seguimiento , Placas Óseas , Fracturas Intraarticulares/cirugía , Fracturas Intraarticulares/diagnóstico por imagen
19.
Sci Rep ; 14(1): 11795, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38782942

RESUMEN

The clinical finite element analysis (FEA) application in maxillofacial surgery for mandibular fracture is limited due to the lack of a validated FEA model. Therefore, this study aims to develop a validated FEA model for mandibular fracture treatment, by assessing non-comminuted mandibular fracture fixation. FEA models were created for mandibles with single simple symphysis, parasymphysis, and angle fractures; fixated with 2.0 mm 4-hole titanium miniplates located at three different configurations with clinically known differences in stability, namely: superior border, inferior border, and two plate combinations. The FEA models were validated with series of Synbone polymeric mandible mechanical testing (PMMT) using a mechanical test bench with an identical test set-up. The first outcome was that the current understanding of stable simple mandibular fracture fixation was reproducible in both the FEA and PMMT. Optimal fracture stability was achieved with the two plate combination, followed by superior border, and then inferior border plating. Second, the FEA and the PMMT findings were consistent and comparable (a total displacement difference of 1.13 mm). In conclusion, the FEA and the PMMT outcomes were similar, and hence suitable for simple mandibular fracture treatment analyses. The FEA model can possibly be applied for non-routine complex mandibular fracture management.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación Interna de Fracturas , Mandíbula , Fracturas Mandibulares , Fracturas Mandibulares/cirugía , Humanos , Mandíbula/cirugía , Mandíbula/fisiología , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Pruebas Mecánicas , Titanio , Estrés Mecánico , Polímeros/química
20.
Jt Dis Relat Surg ; 35(2): 276-284, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727105

RESUMEN

OBJECTIVES: This study aimed to compare the efficacy and safety of the intramedullary nail and conventional plate for the treatment of displaced intra-articular calcaneal fractures from clinical comparative trials. MATERIALS AND METHODS: A comprehensive search of English databases was carried out in the Springer, PubMed, ScienceDirect, Web of Science, and Cochrane Library databases until September 2023. Studies on calcaneal fractures treated by an intramedullary nail or a plate were considered for inclusion. Endpoints included duration of operation, length of hospital stay, the Visual Analog Scale (VAS) score, postoperative functional score, radiological parameters, and complications. The mean difference (MD) and risk difference (RD) as the combined variables, as well as the 95% confidence intervals, (CIs) were calculated. RESULTS: Five retrospective controlled studies covering 473 feet at the one-year follow-up met the inclusion criteria. The meta-analysis demonstrated that there were significant differences in the duration of operation (MD: -10.81; 95% CI: -16.32, -5.31; p=0.0001), length of hospital stay (MD: -3.65; 95% CI: -4.35, -2.95; p<0.00001). No significant differences were found regarding postoperative American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale (MD: 0.36; 95% CI: -3.89, 4.61; p=0.87), VAS (MD: 1.95; 95% CI: -0.30, 4.21; p=0.09), or postoperative Böhler angle (MD: 0.94; 95% CI: -0.04, 1.92; p=0.06) between the two groups. The incidence of total complications (RD: -0.31; 95% CI: -0.46, -0.17; p<0.0001) and wound-healing complications (RD: -0.16; 95% CI: -0.30, -0.03; p=0.02) were lower in the intramedullary nail group. There were no significant differences in the incidences of revision surgery, implant removal, superficial wound infection, deep infection, and nonunion. CONCLUSION: Compared to conventional plates, the intramedullary nail showed a shorter duration of operation, reduced length of hospital stay, and fewer postoperative total complications and wound-healing complications in treating displaced intra-articular calcaneal fractures.


Asunto(s)
Clavos Ortopédicos , Placas Óseas , Calcáneo , Fijación Intramedular de Fracturas , Humanos , Calcáneo/lesiones , Calcáneo/cirugía , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Fracturas Intraarticulares/cirugía , Tiempo de Internación , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA