Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.141
Filtrar
1.
Acta Ortop Mex ; 38(2): 95-100, 2024.
Artículo en Español | MEDLINE | ID: mdl-38782474

RESUMEN

INTRODUCTION: one- or two-stage total revision is considered the gold standard for the treatment of hip arthroplasty with chronic infection. However, during the removal of a fixed prosthetic component, the host bone may be damaged, making definitive prosthetic reimplantation difficult. OBJECTIVE: we present a series of patients treated for chronic periprosthetic hip infection with preservation of one fixed component. MATERIAL AND METHODS: this study included 12 patients with hip arthroplasty and chronic periprosthetic infection scheduled for one or two-stage partial replacement with retention of a fixed component between June 2015 and January 2021. The minimum follow-up period was 2 years (mean, 4.08 years). None of the 12 patients in this series was lost to follow-up. We evaluated the evolution through clinical examination, Harris Hip Score, laboratory and radiological studies. RESULTS: at a mean follow-up of 4.08 years after prosthetic reimplantation, two of the 12 patients had recurrence of infection (16.6%), and the mean Harris hip score reached 63.6 points at the last follow-up assessment. CONCLUSIONS: fixed implant preservation may be an acceptable option for patients with chronic periprosthetic hip infection when removal of the fixed component results in significant bone loss compromising future reimplantation. However, more studies are required on this treatment method.


INTRODUCCIÓN: la revisión total en una o dos etapas se considera el estándar de oro para el tratamiento de la artroplastía de cadera con infección crónica. Sin embargo, durante la extracción de un componente protésico fijo, el hueso del huésped puede dañarse, lo que dificulta la reimplantación definitiva de la prótesis. OBJETIVO: presentamos una serie de pacientes tratados por infección crónica periprotésica de cadera con la preservación de un componente fijo. MATERIAL Y MÉTODOS: este estudio retrospectivo incluyó a 12 pacientes con artroplastía de cadera e infección periprotésica crónica programadas para revisión parcial en una o dos etapas con retención de un componente fijo entre Junio de 2015 y Enero de 2021. El período mínimo de seguimiento fue de dos años (media, 4.08 años). Ninguno de los 12 pacientes de esta serie se perdió en el seguimiento. Evaluamos la evolución a través del examen clínico, puntuación de cadera de Harris, estudios de laboratorio y radiológicos. RESULTADOS: con un seguimiento promedio de 4.08 años después de la reimplantación protésica, dos de los 12 pacientes presentaron recurrencia de la infección (16.6%) y la puntuación media de Harris en la cadera alcanzó 63.6 puntos en la última evaluación de seguimiento. CONCLUSIONES: la preservación del implante fijo puede ser una opción aceptable para pacientes estrictamente seleccionados con infección periprotésica crónica de cadera cuando la extracción del componente fijo produce una pérdida ósea significativa que compromete la reconstrucción futura. Se necesitan más estudios sobre este método de tratamiento.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Infecciones Relacionadas con Prótesis/etiología , Masculino , Femenino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/métodos , Anciano , Enfermedad Crónica , Prótesis de Cadera/efectos adversos , Estudios de Seguimiento , Estudios Retrospectivos , Adulto , Recurrencia
2.
Bone Joint J ; 106-B(6): 555-564, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38821507

RESUMEN

Aims: This study aims to assess the relationship between history of pseudotumour formation secondary to metal-on-metal (MoM) implants and periprosthetic joint infection (PJI) rate, as well as establish ESR and CRP thresholds that are suggestive of infection in these patients. We hypothesized that patients with a pseudotumour were at increased risk of infection. Methods: A total of 1,171 total hip arthroplasty (THA) patients with MoM articulations from August 2000 to March 2014 were retrospectively identified. Of those, 328 patients underwent metal artefact reduction sequence MRI and had minimum two years' clinical follow-up, and met our inclusion criteria. Data collected included demographic details, surgical indication, laterality, implants used, history of pseudotumour, and their corresponding preoperative ESR (mm/hr) and CRP (mg/dl) levels. Multivariate logistic regression modelling was used to evaluate PJI and history of pseudotumour, and receiver operating characteristic curves were created to assess the diagnostic capabilities of ESR and CRP to determine the presence of infection in patients undergoing revision surgery. Results: The rate of PJI for all identified MoM THAs was 3.5% (41/1,171), with a mean follow-up of 10.9 years (2.0 to 20.4). Of the patients included in the final cohort, 8.2% (27/328) had PJI, with a mean follow-up of 12.2 years (2.3 to 20.4). Among this cohort, 31.1% (102/328) had a history of pseudotumour. The rate of PJI in these patients was 14.7% (15/102), which was greater than those without pseudotumour, 5.3% (12/226) (p = 0.008). Additionally, logistic regression analysis showed an association between history of pseudotumour and PJI (odds ratio 4.36 (95% confidence interval 1.77 to 11.3); p = 0.002). Optimal diagnostic cutoffs for PJI in patients with history of pseudotumour versus those without were 33.1 mm/hr and 24.5 mm/hr for ESR and 7.37 mg/dl and 1.88 mg/dl for CRP, respectively. Conclusion: Patients with history of pseudotumour secondary to MoM THA had a higher likelihood of infection than those without. While suspicion of infection should be high for these patients, ESR and CRP cutoffs published by the European Bone and Joint Infection Society may not be appropriate for patients with a history of pseudotumour, as ESR and CRP levels suggestive of PJI are likely to be higher than for those without a pseudotumour. Additional investigation, such as aspiration, is highly recommended for these patients unless clinical suspicion and laboratory markers are low.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Granuloma de Células Plasmáticas , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Masculino , Femenino , Granuloma de Células Plasmáticas/etiología , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Anciano , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Reoperación , Sedimentación Sanguínea , Anciano de 80 o más Años , Proteína C-Reactiva/análisis , Imagen por Resonancia Magnética , Estudios de Seguimiento , Factores de Riesgo
3.
Bone Joint J ; 106-B(6): 565-572, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38821509

RESUMEN

Aims: This study compares the re-revision rate and mortality following septic and aseptic revision hip arthroplasty (rTHA) in registry data, and compares the outcomes to previously reported data. Methods: This is an observational cohort study using data from the German Arthroplasty Registry (EPRD). A total of 17,842 rTHAs were included, and the rates and cumulative incidence of hip re-revision and mortality following septic and aseptic rTHA were analyzed with seven-year follow-up. The Kaplan-Meier estimates were used to determine the re-revision rate and cumulative probability of mortality following rTHA. Results: The re-revision rate within one year after septic rTHA was 30%, and after seven years was 34%. The cumulative mortality within the first year after septic rTHA was 14%, and within seven years was 40%. After multiple previous hip revisions, the re-revision rate rose to over 40% in septic rTHA. The first six months were identified as the most critical period for the re-revision for septic rTHA. Conclusion: The risk re-revision and reinfection after septic rTHA was almost four times higher, as recorded in the ERPD, when compared to previous meta-analysis. We conclude that it is currently not possible to assume the data from single studies and meta-analysis reflects the outcomes in the 'real world'. Data presented in meta-analyses and from specialist single-centre studies do not reflect the generality of outcomes as recorded in the ERPD. The highest re-revision rates and mortality are seen in the first six months postoperatively. The optimization of perioperative care through the development of a network of high-volume specialist hospitals is likely to lead to improved outcomes for patients undergoing rTHA, especially if associated with infection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/mortalidad , Reoperación/estadística & datos numéricos , Infecciones Relacionadas con Prótesis/mortalidad , Masculino , Femenino , Anciano , Persona de Mediana Edad , Alemania/epidemiología , Prótesis de Cadera/efectos adversos , Anciano de 80 o más Años
4.
Jt Dis Relat Surg ; 35(2): 299-304, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38727108

RESUMEN

OBJECTIVES: This study aimed to investigate whether adding tissue samples directly into thioglycolate (TG) broth yielded a greater number of anaerobic organisms than freshly sampled tissue in suspected hip and knee prosthetic joint infections (PJIs). PATIENTS AND METHODS: Between January 2017 and December 2020, a total of 90 patients (46 males, 44 females; median age: 71.7 years; range, 50.8 and 87.8 years) who underwent revision hip or knee arthroplasty were included. Intraoperative samples were taken, with five placed in TG broth and five in standard containers (PC) with subsequent aerobic and anaerobic culturing conducted. Demographic and baseline data of the patients were recorded. The primary outcome was positive bacterial growth from a PJI specimen inoculated directly into TG broth at the time of collection or standard PJI specimen processing. Secondary outcomes investigated were the presence of Cutibacterium acnes (C. acnes) and the curative success of revision procedure. RESULTS: A total of 900 samples (450 PC and 450 TG) were taken from 90 revision arthroplasty patients (47 knees and 43 hips). There was no statistically significant difference in the number of positive bacterial growth samples between TG broth and standard processing (p=0.742). This was consistent with subgroup analysis analyzing C. acnes (p=0.666). CONCLUSION: In hip and knee arthroplasty, there is no benefit in substituting or adding TG broth as a culture medium to better identify both general bacterial species and C. acnes infections specifically. However, the use of TG may be useful in confirming a true positive result for infection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Tioglicolatos , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Femenino , Masculino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Tioglicolatos/farmacología , Prótesis de la Rodilla/efectos adversos , Prótesis de la Rodilla/microbiología , Medios de Cultivo/química , Medios de Cultivo/farmacología , Reoperación , Prótesis de Cadera/efectos adversos , Prótesis de Cadera/microbiología , Manejo de Especímenes/métodos , Estudios Retrospectivos
5.
Acta Orthop ; 95: 174-179, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38629902

RESUMEN

BACKGROUND AND PURPOSE: Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors. METHODS: 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry. RESULTS: A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections. CONCLUSION: We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Cobalto , Estudios Prospectivos , Polietileno , Estudios de Cohortes , Prótesis de Cadera/efectos adversos , Metales , Cromo , Artroplastia de Reemplazo de Cadera/métodos , Diseño de Prótesis
6.
PLoS One ; 19(4): e0300956, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38630711

RESUMEN

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/epidemiología , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Oseointegración , Fémur/cirugía , Reoperación/efectos adversos , Estudios Retrospectivos
7.
Acta Orthop Belg ; 90(1): 135-138, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669663

RESUMEN

This case report describes a single patient with recurrent implant fractures of his left total hip replacement. According to our knowledge this is the first patient in literature with recurrent implant fractures. This is a rare phenomenon as reason for revision. Risk factors for implant failure of total hip replacement include a lack of proximal support, a distally well fixed stem with proximal debonding, malalignment of the stem and raised BMI.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Falla de Prótesis , Recurrencia , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Masculino , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Anciano
8.
Acta Orthop Belg ; 90(1): 139-141, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669664

RESUMEN

Liner dissociations are rare but catastrophic complications after THA, requiring revision surgery. Although this complication has been well documented in THA with modular components, it has been rarely described in preassembled designs. In this report we present a rare case of liner dissociation in a ceramic-on-ceramic pre-assembled cup design. A 41-year-old man who received THA seven years ago, presented with sudden pain in the hip. Radiographic examination confirmed a small dissociation of the liner component in the acetabular shell, as well as radiolucency between the acetabular shell and the ceramic liner, and pneumarthrosis. Revision surgery was carried out six weeks following the liner dissociation. To make an accurate diagnosis, orthopaedic surgeons must be aware of the symptoms of liner dissociation.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Cerámica , Prótesis de Cadera , Falla de Prótesis , Reoperación , Humanos , Masculino , Adulto , Prótesis de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Diseño de Prótesis
9.
Bone Joint J ; 106-B(5 Supple B): 125-132, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688510

RESUMEN

Aims: Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants - modular fluted tapered (MFT) femoral components - in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components. Methods: We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used. Results: The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n = 25) and infection (n = 16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only two FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence ≥ 5 mm occurred in 2% of unrevised cases. All stems were radiologically stable at most recent follow-up. Mean Harris Hip Score was 69 (SD 20) at most recent follow-up. Conclusion: This series demonstrated that MFT components were durable and reliable in the setting of two-stage reimplantation THA for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily due to dislocation and recurrent PJI.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Diseño de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/etiología , Masculino , Prótesis de Cadera/efectos adversos , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Falla de Prótesis
10.
Bone Joint J ; 106-B(5 Supple B): 118-124, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688513

RESUMEN

Aims: Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods: The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results: Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion: Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Biomarcadores , Toma de Decisiones Clínicas , Complejo de Antígeno L1 de Leucocito , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Masculino , Complejo de Antígeno L1 de Leucocito/análisis , Anciano , Persona de Mediana Edad , Inmunoensayo/métodos , Líquido Sinovial/metabolismo , Prótesis de Cadera/efectos adversos , Anciano de 80 o más Años , Cuidados Intraoperatorios/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
12.
Arch Orthop Trauma Surg ; 144(5): 2421-2428, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38609679

RESUMEN

BACKGROUND: Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients. METHODS: A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs). RESULTS: A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5-118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59-4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88-4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01-1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83-8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56-2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70-4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified. CONCLUSIONS: This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Femenino , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/cirugía , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Prótesis de Cadera/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Falla de Prótesis , Factores de Riesgo
13.
Eur J Orthop Surg Traumatol ; 34(4): 2155-2162, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38565783

RESUMEN

INTRODUCTION: Increasing interest in the use of anatomical stems has developed as the prevalence of periprosthetic fractures (PPFs) continues to increase. The primary aim of this study was to determine the long-term survivorship and PPF rate of an anatomical femoral stem in a single UK centre. PATIENTS AND METHODS: Between 2000 and 2002, 94 consecutive THAs were performed using the 170 mm Lubinus SP II anatomical femoral stem in our institution. Patient demographics, operative details and clinical outcomes were collected prospectively in an arthroplasty database. Patient records and national radiographic archives were reviewed finally at a mean of 21.5 years (SD 0.7) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. RESULTS: Mean patient age at surgery was 65.8 years (SD 12.5, 34-88 years). There were 48 women (51%). Osteoarthritis was the operative indication in 88 patients (94%). Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (95% confidence interval [CI], 98.0-99.3%) at 10 years and 96.7% (94.5-98.9%) at 21 years. The 20-year stem survival for aseptic loosening was 100% with no cases of significant lysis found (lucent line > 2 mm) and no stems required revision. Patient demographics did not appear to influence risk of revision (p > 0.05). There were 2 revisions in total (2 for acetabular loosening with original stems retained). There were no PPFs identified at mean 21.5 year follow-up and 5 dislocations (5%). CONCLUSIONS: The Lubinus SP II 170 mm stem demonstrated excellent survivorship and negligible PPF rates over 20 years following primary THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Falla de Prótesis , Reoperación , Humanos , Anciano , Femenino , Masculino , Persona de Mediana Edad , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación/estadística & datos numéricos , Adulto , Estudios de Seguimiento , Reino Unido , Diseño de Prótesis , Fémur/cirugía , Fémur/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía
14.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38674229

RESUMEN

Periprosthetic joint infection is a feared complication after the megaprosthetic reconstruction of oncologic and non-oncologic bone defects of including the knee or hip joint. Due to the relative rarity of these procedures, however, optimal management is debatable. Considering the expanding use of megaprostheses in revision arthroplasty and the high revision burden in orthopedic oncology, the risk of PJI is likely to increase over the coming years. In this non-systematic review article, we present and discuss current management options and the associated results focusing on studies from the last 15 years and studies from dedicated centers or study groups. The indication, surgical details and results in controlling infection are presented for debridement, antibiotics, irrigation and retention (DAIR) procedure with an exchange of the modular components, single-stage implant exchange, two-stage exchanges and ablative procedures.


Asunto(s)
Desbridamiento , Infecciones Relacionadas con Prótesis , Humanos , Infecciones Relacionadas con Prótesis/cirugía , Desbridamiento/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Antibacterianos/uso terapéutico , Antibacterianos/administración & dosificación , Reoperación/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Prótesis de Cadera/efectos adversos , Irrigación Terapéutica/métodos
15.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38541184

RESUMEN

Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck's surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas Óseas , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Microscopía Electrónica de Rastreo , Falla de Prótesis , Diseño de Prótesis
16.
Artículo en Inglés | MEDLINE | ID: mdl-38513193

RESUMEN

Pseudotumors have been well documented to occur most frequently in metal-metal bearing total hip arthroplasties and less frequently in metal-polyethylene bearings. There are few cases in the literature of pseudotumors occurring in ceramic-ceramic articulations. We report a case of a large pelvic pseudotumor in a patient with a ceramic-ceramic bearing articulation in a 67-year-old man. In addition to the usual investigations, we did a detailed wear analysis of the ceramic implants and an examination of the soft tissues for particulate debris. The detailed wear analysis did show evidence of stripe wear; however, the volumetric wear was within the expected range. Synchrotron imaging identified strontium and zirconium debris arising from the ceramic surfaces. Although association does not mean causation, no other cause for the large pseudotumor could be identified and presumably represents an idiosyncratic reaction to ceramic debris.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Masculino , Humanos , Anciano , Prótesis de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Polietileno , Cerámica
17.
Bone Joint J ; 106-B(4): 372-379, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555938

RESUMEN

Aims: Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods: We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated. Results: Overall, the reinfection rate was 18%. A total of 14 out of 82 patients (17%) with positive permanent sections at reimplantation experienced reinfection, compared to 26 of 144 patients (18%) with negative results (p = 0.996). Neither permanent sections nor fresh frozen sections were significantly associated with reinfection, with a sensitivity of 0.35, specificity of 0.63, PPV of 0.17, NPV of 0.81, and accuracy of 58%. Histology was not significantly associated with reinfection or survival time for any of the analyzed sub-groups. Permanent and frozen section results were in agreement for 91% of cases. Conclusion: Permanent and fresh frozen sections at reimplantation in two-stage revision do not serve as a reliable predictor for reinfection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Prótesis de Cadera , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Reinfección , Articulación de la Rodilla/cirugía , Reoperación/métodos
18.
Bone Joint J ; 106-B(4): 344-351, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555949

RESUMEN

Aims: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/etiología , Prótesis de Cadera/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Reoperación/métodos , Fracturas del Fémur/cirugía , Estudios Retrospectivos
19.
Bone Joint J ; 106-B(4): 312-318, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555951

RESUMEN

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Enfermedades Óseas Metabólicas , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Porosidad , Acetábulo/cirugía , Reoperación , Metales , Falla de Prótesis , Estudios Retrospectivos , Estudios de Seguimiento
20.
Int Orthop ; 48(5): 1165-1170, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38438578

RESUMEN

PURPOSE: Conversion of a fused hip to a total hip arthroplasty (THA) is technically challenging due to the loss of anatomical references. Here, a reproducible technique using the direct anterior approach (DAA) with a regular surgical table under fluoroscopic guidance is described, which has several advantages over traditional such as lateral or posterior approaches. METHODS: There were reported 11 cases of ankylosis hip that were converted to THA using the same surgical technique protocol. Clinical and radiographic outcomes were recorded at 3.2 years of follow-up. A detailed preoperative evaluation was performed, including a pelvis radiological evaluation and magnetic resonance image (MRI) to assess the integrity of the periarticular soft tissue and flexor muscles. RESULTS: The DAA has considerable advantages, such as allowing more precise targeting during surgery, avoiding the risk of pseudoarthrosis due to the absence of a trochanteric osteotomy, preserving the abductors, and allowing an easier-to-use of intraoperative fluoroscopy due to the supine position. Besides, the use of a standard table reduces surgical time and allows assessment of limb length, hip stability, and impingement in all planes in an intraoperative dynamic range, which decreases postoperative complications. CONCLUSION: Conversion from hip fusion to THA is a rare and complex procedure. The use of DAA with a standard table and fluoroscopy helps to avoid high complications since it allows a dynamic intra-operative examination of the range of motion to rule out impingements, reduces the risk of dislocation, and allows leg lengthening verification.


Asunto(s)
Anquilosis , Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Fluoroscopía/métodos , Radiografía , Anquilosis/etiología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA